Sept 03,2013 JRP Architects Page 1 Building 1215 Acacia Avenue,Suite 1004 Madrigal Bussiness Park Ayala Alabang, Muntinlupa City Attention : Arch. Jimmy R. Powers Principal Architect Subject : Structural Design Proposal Structural Assessment and Design for Existing 2-Storey Residence Location : Malinta Valenzuela Sir: I am pleased to submit my proposal for the Structural Assessment & Design of the Existing Two Storey Residence with deck with proposed additional floor . Please find in the following the scope of work covered by this proposal: I. Scope of Work: 1. Preparation of As Built Plans for Structural Plans -----------------P 15,000.00 Determination Column Lay-out , Beam Lay-out , Slab Lay- out Beam and Column Sizes ( WE CAN DELETE THIS) 2. Preparation of Material Testing--------------------------------------P 15,000.00 Rebar Mapping – Determination quantities of rebars in beams and columns Rebound Hammer Test—A non destructive test for the determination of concrete strength Coring Test – Destructive test for the determination of concrete streng for slabs ( NEGOTIATE UP TO 10, 000)

Upload: aris-r-alcantara

Post on 26-Nov-2015

24 views

Category:

Documents


3 download

DESCRIPTION

Sample Proposal ( Canopy)

TRANSCRIPT

February 8,2005

Sept 03,2013

JRP ArchitectsPage 1 Building 1215 Acacia Avenue,Suite 1004Madrigal Bussiness ParkAyala Alabang, Muntinlupa City

Attention: Arch. Jimmy R. Powers Principal Architect Subject: Structural Design Proposal Structural Assessment and Design for Existing 2-Storey Residence Location: Malinta Valenzuela

Sir:

I am pleased to submit my proposal for the Structural Assessment & Design of the Existing Two Storey Residence with deck with proposed additional floor . Please find in the following the scope of work covered by this proposal: I. Scope of Work:

1. Preparation of As Built Plans for Structural Plans -----------------P 15,000.00 Determination Column Lay-out , Beam Lay-out , Slab Lay-outBeam and Column Sizes ( WE CAN DELETE THIS)

2. Preparation of Material Testing--------------------------------------P 15,000.00Rebar Mapping Determination quantities of rebars in beams and columnsRebound Hammer TestA non destructive test for the determination of concrete strengthCoring Test Destructive test for the determination of concrete streng for slabs( NEGOTIATE UP TO 10, 000)3. Structural Assessment and Analysis of Existing Structure -------P 30,000.00 ( NEGOTIATE UP TO PHP20,000)Investigate and calculates the structural Soundness of existing structure base to the As built plans and results of material testing.Determines whether the structure is safe or need to be retrofitted

4. Preparation of Structural Design -------------------------------------P 30,000.00 (NEGOTIATE UP TO 20,000)Prepares the structural design for the additional StructureDesign of Retrofitting ( If Applicable )

5. Preparation of Structural Plans ( Cad Drawings )------------------P 10,000.00Prepares the structural drawing & For construction Plans ( WE CAN DELETE THIS)6. Preparation of Structural Calculation and Assessment report ---included

7. Sign and Seal of Plans for building Permit--------------------------included

8. Frequent Site Visit-------------------------------------------------------P 2,000/VisitII. Submittals:

1. Cad files of Structural Plans 2. Assessment Report / Structural Analysis and Calculation

In view of the above-mentioned professional services, I am proposing an amount of One Hundred Thousand Pesos Only (P100,000.00)

III) TERMS OF PAYMENT

1. Down Payment - 30%= PhP 30,0002. Balance Through Progress Billing

Above Payment Scheme could be NegotiatedHoping that this proposal will merit your utmost consideration. Thank you

Very Truly Yours,

Engr. Alan Russel C.CaracenaCivil-Structural Engineer09422737207

TARGET COST : 1. PHP 0 2. PHP 10,000 3. PHP 20,000 4. PHP 20,000 5. PHP 0TOTAL PHP 50,000 NOTE : NEGOTIATE FURTHER TO INCLUDE TWO(2) SITE VISIT IN THE NEGOTIATED CONTRACT OF PHP 50,000