FIRE RATED GLAZING SOLUTIONS
FACADES + Performance Symposium
April 16, 2015 | New York, NY
Midtown Community Court in New York, NY Architect: DMJM Harris/AECOM Glazier: Egan Architectural Metal & Glass
FIRE RATED GLASS IN EXTERIOR APPLICATIONS PROVIDE:
1-Hour GPX Curtain Wall Project: The Kensington in Boston, MA Architect: TAT Building Envelope Consultant: CDC Glazing Contractor: Cheviot
• Fire Rating
• Clear Views
• Air + Water Control
• Thermal Performance
• Structural Performance
• Seamless Design Additional Performance Options: • Sunshade System
• Blast/Ballistic
• Decorative
FIRE RATED GLASS TESTING
Test includes:
(except for 20 min. doors)
Test includes:
FIRE ENDURANCE TEST
HOSE STREAM TEST
FIRE RESISTIVE GLASS BLOCKS RADIANT HEAT
• Glass exposed to fire
• Fire retardant forms into heat absorbing char
• Glass temperature remains low, radiant heat is blocked
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
AIR / WATER CONTROL
Air Infiltration: ASTM E 283-04 at 6.24 psf. Result: No Leakage. Static Pressure: ASTM E 331-00 at 20.0 psf. Result: No Leakage. Dynamic Pressure Water Resistance: AAMA 501-1.05 at 12.0 psf. Result: No Leakage.
GPX Curtain Wall Framing Mock-up for Dynamic Testing
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
Midtown Community Court in New York, NY Architect: DMJM Harris/AECOM Glazier: Egan Architectural Metal & Glass
THERMAL PERFORMANCE
U-Value for Glass & Framing Assembly: 0.39 SHGC for Glass and Framing Assembly: 0.31
Thermal Cycling and Condensation Evaluation: Exterior 170 degrees F: -10 degrees F / Interior: 68 degrees F. Result: No Damage, No Condensation. Condensation Resistance Factor of Frame: 68 Condensation Resistance Factor of Glass: 71
2-Hour GPX Curtain Wall Project: CMC Kravis Center in Claremont, CA Architect: Rafael Vinoly Architects Glazing Contractor: Benson Industries
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
Midtown Community Court in New York, NY Architect: DMJM Harris/AECOM Glazier: Egan Architectural Metal & Glass
STRUCTURAL PERFORMANCE
Structural Performance: ASTM E-330 between -75.0 psf to 60.0 psf. Result: Passed with No Damage. Interstory Vertical Displacement Test: 1” Parallel, 1” Perpendicular. Result: No Damage. Seismic Movement Test: ¾” cycled movement horizontally. Result: No Damage.
2-Hour GPX Curtain Wall / Elevator Enclosure Project: Aspen Art Museum in Aspen, CO Architects: Shigeru Ban / CCY Glazing Contractor: Harmon Inc.
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
STRUCTURAL GLAZING: VERTICAL BUTT-JOINT
Fire Resistive Multilaminte: SuperLite III-XL No Vertical Intermediate Framing: SuperLite III-XL glass provides the structural integrity to make the span without the need for a vertical intermediate. Fire Rating: Up to 2 hours meeting ASTM E-119/NFPA 251/UL 263 with hose stream.
1-Hour GPX Wall with SuperLite III-XL 60 Project: Bucks County Community College Rollins Advising Center Architect: Schrader Group Architecture
SUNSHADE INTEGRATION
1-Hour GPX Wall Openings with Sunshade Integration Project: Oakland Airport Connector – Doolittle BART Station in Oakland, CA Architect: ED2 International Glazing Contractor: Bagatelos Glass
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
Midtown Community Court in New York, NY Architect: DMJM Harris/AECOM Glazier: Egan Architectural Metal & Glass
ADDITIONAL SECURITY: BALLISTIC AND BLAST
Ballistic Performance: Up to UL 752 Level 8 Ballistic Blast Performance: ASTM F2248 (3-Second Duration Design Loading). Can be engineered to meet all levels of blast protection.
1-Hour GPX Blast / Ballistic Wall Openings Project: VA Primary Care Annex in Tampa, FL Architect: HGA Glazing Contractor: ACME Glass
Weill Cornell Medical College in New York, NY Architect: Ennead Architects Glazier: W&W Glass, LLC
FORT IRWIN REPLACEMENT HOSPITAL
Fire Rating: 2-hours Blast Rating: + 50.00 psf. Anchors designed to resist 2.0 x the blast reaction. Wind Load: +21.50/-23 psf (typical); + 21/50/-28.70 psf (corner). Basic wind speed of 85 mph. Glass Make-up: SuperLite II-XL 120 with 9/16” Heat Strengthened Clear Laminated Inboard Lite Framing: GPX Blast Curtain Wall Overall Height: 584” (approx. 49 ft.)
2-Hour GPX Blast Curtain Wall Architect: RLF / Ellerbe Becket (A Joint Venture) Glazing Contractor: Sashco Inc.