safety and protection installations
TRANSCRIPT
Our products for your projectTowards the future with OBO
Reliable, safe and of the highest quality: Product features such asinstallation speed, load capacity, functionality and availability areat the forefront of each of our innovations. Discover the wholerange of OBO products – in a new structure, allowing us to deal ina more targeted manner with the needs of you, our customers.
It is our aim to be the first port of call for the best and most innova-tive connections for electrical and data technology infrastructure.Thus, when looking towards the future, we have asked ourselveswhat we can do to be the best possible partner you could everimagine, also in the long term. Against this backdrop, we haveoptimised our structure once again, sharpened our profile anddefined our services more clearly. The result: Three new areas ofapplication, which replace our previous seven product units, inorder to provide you with a contemporary and user-orientatedvisual identity and structure, for both products and communica-tion. This helps you to find exactly the products you are looking forin an even faster and simpler manner.
In this catalogue, we will present to you the variety of the entireproduct range of the safety and protection installations applicationarea. Here, one thing – above all else – is in the spotlight: Safety.Besides our expert knowledge in this field, we place particularemphasis on innovations in product development and comprehen-sive quality testing, in order to offer you maximum protection at alltimes.
Our products for surge and lightning protection provide reliableprotection against the impacts of thunderstorms and remote swit-ching operations. These can cause not only significant damage toproperty, but also endanger human lives. The unique, wide pro-duct range in the field of fire protection makes OBO one of the fewproviders who cover all three protection aims and help you to pro-tect people and property as best as possible in case of fire.
OBO ‒ simply better.
2
OBO Product Worlds
Safety and protection installationsSurge protectionExplosion protectionLightning protectionEarthingEquipotential bondingInsulationCable bandages – prevention of the spread of fireEscape route installations – false ceiling mountingFire protection ductsSystems for the maintenance of electrical functionality – cable-specific routing variantsSystems for the maintenance of electrical functionality – standard support structures and routing systemsSystems for the maintenance of electrical functionality – FireBox T series junction boxesAnchorings
You can find additional products in our newIndustrial installations and Building installati-ons catalogues
Industrial installationsCable support systems and connection andfastening systems for industry and construction project infrastructureCable traysMesh cable traysCable laddersIndustrial ductsSupport structuresElectrical installation pipesWiring ductsPower supply unitsDistributorsJunction boxesConcealed and cavity wall installationsTerminalsCable glandsInstallation and fastening clipsAnchors and fastening systems
Building installationsCable routing and underfloor systems foradministrative and functional buildings including architectural solutionsElectrical installation ducts and trunkingDevice installation ducts and trunkingSkirting trunkingService polesUnderfloor applications, in screedUnderfloor applications, in concreteUnderfloor applications, on-floorService outlets for underfloor applicationsFloor sockets and floor boxesInstallation housing and supportTabletop socketsSockets, switches, data and multimedia technology
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
3
6955640
Directories Page 104
Cable bandages – prevention of the spread offire
Page 94
Insulation – maintenance of the fire sections Page 10
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Welcome world.Welcome to OBO.New solutions to improve functionality and the ease of instal-lation – OBO employees all around the world use their abili-ties and creativity to make this happen. Because we knowthat each individual market has its special characteristics andthat the requirements for our products change within eachmarket, we have paid particular attention to the compatibilityof products in their place of use. We always offer our custo-mers intelligent, well-thought-out solutions. Our brands alwayskeep this promise. The OBO global team wishes to make thework of electrical planners and operatives around the worldas easy as possible.
6
Production location
Subsidiary
Representative office
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
7
OBO Support& contact
You have aproblem?
We have thesolution!
OBO Bettermann is more than the sum of itsproducts. In any situation, we are the relia-ble partner right buy your side. You have aproblem? We have the solution!
It doesn’t matter in which area of industryour support is needed - from industrial andplant engineering to private, public andadministrative buildings, as well as in theareas of mobility and renewable energies -we have all that you need.
OBO can not only provide the entire electro-technical infrastructure with the best possi-ble products. We can also support you withsound expert knowledge and more than 100years of experience, right from the planningphase through to the realisation of your pro-jects. OBO - solutions you can rely on.
8
You can contact our Customer Service depart-ment on:
+49 2373 89 1700Monday–Thursday07.30–17.00
Friday07.30–15.00
Service Training Handling Certification
Service – OBO can helpEverywhere and in every projectphase:• Competent hotline• Product and system information,
digitally or printed• Selection and planning aids on the
web, as an app, as a CAD applica-tion or in printed form
• 2D and 3D product data for plan-ning
• Field service, branch offices andsubsidiaries in 60 countries
• Engineering services for major pro-jects
Training courses from OBO• Seminars and workshops• Local consultation and training
courses• Planner days
Handling – OBO delivers reliablyWith optimised delivery processes:• Reliable logistics• Practical transport systems and
packaging• Loading gear handling and dispo-
sal concepts
Certification and guaranteeOBO offers safety. Our products fulfilthe most important country-specificregulations:• Conformity (e.g. IEC, VDE, CE,
KEMA, KEUR, UL)• Certification (e.g. DIN EN, DGNB)• 5-year guarantee for surge protec-
tion products• Guarantee management
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
9
Insulation - maintenance of thefire sections
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
10
Insulation - maintenance of thefire sections
PYROPLUG® Mini small insulation 88
PYROCOMB® Intube pipe shell 80
PYROCOMB® pipe sleeve 68
PYROPLUG® foam series 44
PYROSIT® NG fire protection foam 36
PYROBAG® bag insulation 30
PYROPLATE® Fibre soft insulation 22
PYROMIX® mortar insulation 12
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
11
PYROMIX® - Mortar insulation System description
The PYROMIX® system from OBO is used to createcable and combination insulation made of a mine-ral fibre-free special mortar. Depending on theamount of water added, the finished compoundcan be applied to openings by hand, with pumpsor with presses. The high level of substrate adhe-
sion makes lining unnecessary for small insulationareas. The porous consistency of the mortarmeans that retroinstallation is easy. If there is a fire,the fire protection mortar reliably prevents thespread of fire and smoke.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
12
PYROMIX® - Mortar insulation Installation principle
Stir the mortar with water until thedesired consistency is reached.
Apply mortar to the opening, uselining as necessary.
Use approved section insulationfor metal pipes.
Section insulation should also beapplied to steel electrical installa-tion pipes.
Mount pipe sleeves for combusti-ble pipes on both sides of thewall.
Apply labelling to combinationinsulation for various structures.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
13
PYROMIX® - Mortar insulation Registration data
Combination insulation in walls/ceilingsFire resistance class EI 180, EI 240
Proof of application European Technical Assessment of DIBt, Berlin
Approval number ETA-17/0472
Testing standard EN 1366-3
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
15 cm(EI 60 / EI 90 / EI 120) ‒
15 cm(S30 / S60 / S90)
Min. insulation thickness
15 cm(EI 60 / EI 90 / EI 120)24 cm (EI 120)
‒15 cm(EI 60 / EI 90 / EI 120)24 cm (EI 120)
Opening size
≤ 120 cm (for EI 120)≤ 200 cm
‒
120 cm (for EI 120)≤ 60 cm x ≤ 60 cm
120 cm (for EI 120)≤ 60 cm x ≤ 60 cm
‒
≤ 100 cmUnlimited
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
14
PYROMIX® - Mortar insulation Installations
Cable
Ø 80 mm
Pipe bundle of electrical installation pipes
Only with PYROCOMB Intube
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Ø 16 mm,cable Ø 16 mm
Individual lines for control purposes
Cable support systems
Steel profiles
Electrical installation pipe made of plastic, rigid
Ø 16 mm,cable Ø 21 mm
Metal pipes with path insulation
Steel, stainless steel andcast steel Ø 323.9 mm,copper Ø 108.0 mm
Electrical installation pipe made of plastic, flexible
Only with PYROCOMB Intube
Plastic pipes
Ø 160 mm
Special installations
Double solar pipes
Stainless steel with insulation+ accompanying cable Ø40 mm(Ceiling 30 min.)
Speed pipe
24 pipes Ø 7 mm x 1.5 m,7 pipes Ø 10 mm x 2.0 m,5 pipes Ø 12 mm x 2.0 mm,Ø 50 mm total
Klimasplit
Tubolit Duo SplitØ 6.0‒18.0 mm
Hydraulic hoses
HANSA-FLEX HD 200-2 SNØ 55.9 mm (150 mm compo-nent)
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
15
Mortar insulation PYROMIX®
PYROMIX® dry mortar in paper sack
20TypeMSX-S1
Contentskg
Weightkg/100 pc.2,000.000
Item no.7206104
PackPiece1
Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pres-sing and for manual installation. Adding approx. 6 litres of water to 20 kg of dry mortar produces about 20litres of workable compound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.
PYROMIX® dry mortar in bucket
10TypeMSX-E1
Contentskg
Weightkg/100 pc.1,000.000
Item no.7206058
PackPiece1
Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pres-sing and for manual installation. Adding approx. 3 litres of water to 10 kg of dry mortar produces about 10litres of workable compound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.
Insulation layer creator in a cartridge
Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for the closing of core drill holes when feeding through single cables and for closing the annular gap whenexiting cables from the PYROLINE® Con PLC fire protection duct. Material class DIN 4102 - B2, normally flam-mable. In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.
300TypeDSX-K
Contentsml
Weightkg/100 pc.50.000
Item no.7202300
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
16
Mortar insulation PYROMIX®
Insulation layer creator in a bucket
Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for closing core drill holes for individual cable glands.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.
5TypeDSX-E
Contentskg
Weightkg/100 pc.500.000
Item no.7202302
PackPiece1
Pipe sleeve with 2 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M6 threaded rods.
32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54
TypeTCX-032TCX-040TCX-050
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.6.5007.0008.000
Item no.720220072022017202203
PackPiece111
Pipe sleeve with 4 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.
63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129
TypeTCX-063TCX-075TCX-090TCX-110TCX-125
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.15.50019.00037.00046.00070.000
Item no.72022047202205720220672022077202208
PackPiece11111
Pipe sleeve with 6 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
140 - 142 40 200 144160 - 162 40 220 164
TypeTCX-140TCX-160
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.106.000107.000
Item no.72022097202210
PackPiece11
Threaded rod
Threaded rod to DIN 976.
M6 6 1000M8 8 1000
TypeTR M6 1M GTR M8 1M G
Thread
Dim.dmm
Dim.Lmm
Weightkg/100 pc.18.30030.000
Item no.31410473141128
PackPiece1010
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
17
Mortar insulation PYROMIX®
Hexagonal nut DIN 934
Hexagonal nut to DIN 934 with metric thread.
M6 10 5.2 6M8 13 6.8 8
TypeHN M6 GHN M8 G
ThreadSWmm
Dim. hmm
Dim.dmm
Weightkg/100 pc.0.2210.500
Item no.34000693400085
PackPiece100100
Washer ISO 7093
Washer of large outer diameter for universal use.
M6 6.5 28 2.5M8 8.5 28 2.5
TypeWS M6 D28 GWS M8 D28 G
Thread
Dim.dmm
Dim. Dmm
Dim. hmm
Weightkg/100 pc.1.1041.100
Item no.34022073402215
PackPiece100100
MMS-plus P round head tie, with panhead
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With roundhead for universal fastenings. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
6 x 50 5 11.2 Torx 50TypeMMS+ P 6x50
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Dim.Lmm
Weightkg/100 pc.1.000
Item no.3498108
PackPiece100
MMS-plus MS mounting rail tie, with flat pan-head
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx
TypeMMS+ MS 7.5x50MMS+ MS 7.5x60
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Weightkg/100 pc.1.5001.800
Item no.34982613498262
PackPiece10050
Section insulation for metal pipes
Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.
Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks
Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C
6100 500 30TypeMIW-MA
Lengthmm
Widthmm
Thicknessmm
Weightkg/100 pc.1,010.000
Item no.7202308
PackPiece2
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
18
Mortar insulation PYROMIX®
Aluminium adhesive tape for path insulation
Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.
100 100TypeMIW-AT
Lengthm
Widthmm
Weightkg/100 pc.136.900
Item no.7202305
PackPiece1
Winding wire for path insulation
The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.
50TypeMIW-TD
Lengthm
Weightkg/100 pc.10.000
Item no.7202309
PackPiece1
Bandage for insulation
Coated fire protection coil with material that foams up in the event of fire for wrapping installations in thePYROMIX® mortar insulation and PYROPLATE® Fibre plate insulation.
The coil can be used as an addition, according to the appropriate proof of suitability.
10 125TypeFSB-WB 1.5
Lengthm
Widthmm
Weightkg/100 pc.220.000
Item no.7203163
PackPiece1
Mineral wool
Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.
25 LiterTypeMIW-S
Dimension Weightkg/100 pc.250.000
Item no.7202306
PackPiece1
Calcium silicate plate
Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.
500 150 20500 250 301000 250 30
TypeKSI-P1KSI-P2KSI-P3
Dim.Lmm
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.42.000111.000222.000
Item no.720228372029047202912
PackPiece111
L
BD
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
19
Mortar insulation PYROMIX®
PYROCOMB® Intube pipe shell, Ø 120 mm
Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.
150 116.4 107 125300 116.4 107 125
TypeCTS 12150CTS 12300
Dim.Lmm
Dim. Bmm
Dim. Dmm
ForopeningØ mm
Weightkg/100 pc.35.20070.000
Item no.72043007204304
PackPiece11
Identification plate
100
70
25
Ø 7
85
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
Support construction for insulations, withbracket
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.
70 217 50TypeSKA 05 VZ
Dim.Hmm
Dim. Bmm
Dim.Amm
Weightkg/100 pc.190.740
Item no.7202436
PackPiece1
Support construction for insulations, with pen-dulum suspension
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.
1000TypeSKP 05 VZ
Dim.Lmm
Weightkg/100 pc.235.240
Item no.7202446
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
rese
ctio
ns
20
Soft insulation, PYROPLATE® Fibre System description
The PYROPLATE® Fibre system from OBO is usedto create cable and combination insulation. Thecore of the system is the mineral fibre plate coatedwith a moisture-resistant ablation coating. Whenthere is a fire, the fire protection coating creates aninsulating carbon foam and, in combination withthe mineral fibre plate, prevents the spread of fireand smoke. According to the European Technical
Assessment, in addition to the cables, pipes madeof steel, copper or various plastics may also be runthrough the same insulation. For pipelines, additio-nal fire protection measures, such as section insu-lation and pipe sleeves, are required. The mortar orsoft insulation made of PYROPLATE® Fibre is thuscombination insulation which is appropriate fordiverse structures.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
22
Soft insulation, PYROPLATE® Fibre Installation principle
The installation is possible in light-duty partition walls or in solidwalls.
Moisten the component layer andapply the coating to the cutedges for adhesion.
The plates can be inserted care-fully with a hammer and board.
Use approved section insulationfor metal pipes.
Apply the final coating to the sur-face and the installations.
Secure soft insulation in ceilingsagainst footfall.
Cut the plates for mounting.
Finished installation in a light-dutypartition wall.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
23
Soft insulation, PYROPLATE® Fibre Registration data
Combination insulation in walls and ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120, EI, 180, EI 240
Proof of application European Technical Assessment of DIBt, Berlin
Approval number ETA-17/0364
Testing standard DIN EN 1366 Part 3
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm (EI 15 / EI 30 / EI 60/ EI 90) 10 cm (EI 15 / EI 30/ EI 60 / EI 90/ EI 120)20 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 /EI240)
10 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)
12.5 cm (EI 15 / EI 30 / EI60 / EI 90)15 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)20 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 /EI240)
Min. insulation thickness
6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)24 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 / EI240)
6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)
6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)24 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 / EI240)
Opening sizefor 6 cm insulation thick-ness
≤ 117.5 cm≤ 120 cm
≤ 117.5 cm≤ 120 cm
≤ 120 cm x ≤ 240 cm≤ 80 cm x ≤ unlimited
Opening sizefor 12 cm insulation thick-ness
≤ 140 cm≤ 200 cm
≤ 140 cm≤ 200 cm
≤ 140 cm≤ 200 cm
Opening sizefor 24 cm insulation thick-ness
≤ 60 cm≤ 60 cm
‒
≤ 60 cm≤ Unlimited
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
24
Soft insulation, PYROPLATE® Fibre Installations
Cable
Cable Ø 80 mm
Pipe bundle of electrical installation pipes
Ø 100 mm, IR Ø 32 mm,cable Ø 21 mm
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Steel profiles
Electrical installation pipe made of plastic, rigid
Ø 16 mm
Metal pipes with path insulation
Steel, stainless steel andcast steel Ø 332.9 mm,copper Ø 108.0 mm
Electrical installation pipe made of plastic, flexible
Ø 32 mm,cable Ø 21 mm
Plastic pipes
Ø 160 mm
Special installations
Speed pipe
24 pipes Ø 7 mm x 1.5 m,7 pipes Ø 10 mm x 2.0 m,5 pipes Ø 12 mm x 2.0 mm,Ø 50 mm total
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Double solar pipes
"NanoSUN" DN 16 to DN 40
Klimasplit
"Tubolit DuoSplit", "TubolitSplit" or comparable6.0 mm–22.0 mm
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
25
Soft insulation, PYROPLATE® Fibre
Mineral fibre plate, pre-coated
H
Mineral fibre plate, pre-coated with the ablation coating ASX, as the basis for the soft insulation. 50 mm plate forinsulation according to German approval, 60 mm plate for insulation according to European approval.
1000 600 50TypePSX-P
Lengthmm
Widthmm
Heightmm
Weightkg/100 pc.625.000
Item no.7202295
PackPiece4
Ablation coating PYROCOAT® in a cartridge
310TypeASX-K
Contentsml
Weightkg/100 pc.50.000
Item no.7202310
PackPiece1
Combined, endothermic and weatherproof coating for internal and external areas. Universal protectioncoating for cable and cable support structures. Use as direct filler, and as paint when stirred.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.
Ablation coating PYROCOAT® in a bucket
5TypeASX-E
Contentskg
Weightkg/100 pc.500.000
Item no.7202312
PackPiece1
Combined, endothermic and weatherproof coating for internal and external areas. Universal protectioncoating for cable and cable support structures. Use as direct filler, and as paint when stirred. Sufficient foran area of 4 m².Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
26
Soft insulation, PYROPLATE® Fibre
Pipe sleeve with 2 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M6 threaded rods.
32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54
TypeTCX-032TCX-040TCX-050
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.6.5007.0008.000
Item no.720220072022017202203
PackPiece111
Pipe sleeve with 4 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.
63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129
TypeTCX-063TCX-075TCX-090TCX-110TCX-125
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.15.50019.00037.00046.00070.000
Item no.72022047202205720220672022077202208
PackPiece11111
Pipe sleeve with 6 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
140 - 142 40 200 144160 - 162 40 220 164
TypeTCX-140TCX-160
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.106.000107.000
Item no.72022097202210
PackPiece11
Threaded rod
Threaded rod to DIN 976.
M6 6 1000M8 8 1000
TypeTR M6 1M GTR M8 1M G
Thread
Dim.dmm
Dim.Lmm
Weightkg/100 pc.18.30030.000
Item no.31410473141128
PackPiece1010
Hexagonal nut DIN 934
Hexagonal nut to DIN 934 with metric thread.
M6 10 5.2 6M8 13 6.8 8
TypeHN M6 GHN M8 G
ThreadSWmm
Dim. hmm
Dim.dmm
Weightkg/100 pc.0.2210.500
Item no.34000693400085
PackPiece100100
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
27
Soft insulation, PYROPLATE® Fibre
Washer ISO 7093
Washer of large outer diameter for universal use.
M6 6.5 28 2.5M8 8.5 28 2.5
TypeWS M6 D28 GWS M8 D28 G
Thread
Dim.dmm
Dim. Dmm
Dim. hmm
Weightkg/100 pc.1.1041.100
Item no.34022073402215
PackPiece100100
Bandage for insulation
Coated fire protection coil with material that foams up in the event of fire for wrapping installations in thePYROMIX® mortar insulation and PYROPLATE® Fibre plate insulation.
The coil can be used as an addition, according to the appropriate proof of suitability.
10 125TypeFSB-WB 1.5
Lengthm
Widthmm
Weightkg/100 pc.220.000
Item no.7203163
PackPiece1
Section insulation for metal pipes
Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.
Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks
Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C
6100 500 30TypeMIW-MA
Lengthmm
Widthmm
Thicknessmm
Weightkg/100 pc.1,010.000
Item no.7202308
PackPiece2
Aluminium adhesive tape for path insulation
Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.
100 100TypeMIW-AT
Lengthm
Widthmm
Weightkg/100 pc.136.900
Item no.7202305
PackPiece1
Winding wire for path insulation
The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.
50TypeMIW-TD
Lengthm
Weightkg/100 pc.10.000
Item no.7202309
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
28
Soft insulation, PYROPLATE® Fibre
Mineral wool
Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.
25 LiterTypeMIW-S
Dimension Weightkg/100 pc.250.000
Item no.7202306
PackPiece1
Calcium silicate plate
Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.
500 150 20500 250 301000 250 30
TypeKSI-P1KSI-P2KSI-P3
Dim.Lmm
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.42.000111.000222.000
Item no.720228372029047202912
PackPiece111
L
BD
PYROCOMB® Intube pipe shell, Ø 120 mm
Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.
150 116.4 107 125300 116.4 107 125
TypeCTS 12150CTS 12300
Dim.Lmm
Dim. Bmm
Dim. Dmm
ForopeningØ mm
Weightkg/100 pc.35.20070.000
Item no.72043007204304
PackPiece11
Identification plate
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
100
70
25
Ø 7
85
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
29
PYROBAG® Bag insulation System description
The PYROBAG® system from OBO is used tocreate cable insulation from fire protection cus-hions. The fire protection cushions, which can beshaped in any way, are stacked simply and quicklyon top of each other, allowing absolutely tidy anddust-free mounting. The cushions can be used forpermanent or temporary insulation in walls and cei-lings, e.g. during renovations. The fire protectioncushions are an ideal solution for frequent retroin-
stallations. Additional cables can be installedquickly, neatly and economically at a later datebecause the cushions can be used several timesover. The cushions consist of a close-knit, denseand mechanically solid glass fabric with a specialfilling. The shell and the filling are free of mineralfibres and are also weatherproof and waterproof.Neither painting nor the use of filler are required.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
30
PYROBAG® Bag insulation Installation principle
Closing of the opening with cushi-ons – without filler or coating.
Panels as mounting aid for thelast cushion layer.
Lock against falling out duringceiling mounting.
Lock against slippage above thefloor.
Cushions arranged in the duct.
Retaining profile to prevent slip-page in vertical arrangements.
Discreet attachment of the identifi-cation plate.
Classification to DIN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
31
PYROBAG® Bag insulation Registration data
Insulation in walls/ceilingsFire resistance class S30, S60, S90
Proof of application General construction approval of DIBt, Berlin
Approval number Z- 19. 15-1115
Testing standard DIN 4102 Part 9
Insulation in cable routing ductsFire resistance class S90
Proof of application General construction approval of DIBt, Berlin
Approval number Z-19.15-1119
Testing standard DIN 4102 Part 9
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm(S30/S60/S90)
10 cm(S30/S60/S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
35 cm(S30 / S60 / S90)
35 cm(S30 / S60 / S90)
35 cm(S30 / S60 / S90)
Opening size
≤ 100 cm,≤ 150 cm
≤ 100 cm,≤ 100 cm
≤ 60 cm,unlimited
Insulation in cable ducts
Component Rigid walls Flexible walls Rigid floors
Min. insulation thickness10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Duct size35 cm(S30 / S60 / S90)
35 cm(S30 / S60 / S90)
35 cm(S30 / S60 / S90)
Plastic ducts 21 cm x 10 cm 21 cm x 10 cm 21 cm x 10 cm
Metal ducts 21 cm x 8 cm 21 cm x 8 cm 21 cm x 8 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
32
PYROBAG® Bag insulation Installations
Cable
All Ø
Pipe bundle of electrical installation pipes
Cable bundle
Ø 150 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Profiles made of steel, alumi-nium or plastic
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Plastic pipes
Special installations
Plastic ducts
210 × 100 mm, wall thickness≤ 3.5 mm
Insulation in the lining pipe
Ø 200 mm,wall thickness 3.5 mm, PVC
Metal ducts
210 × 80 mm, wall thickness≤ 2.0 mm
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
33
PYROBAG® bag insulation
PYROBAG® fire protection cushion
Cable fire protection cushions made of dense, closely knit and mechanically solid glass mesh with a special filling.Free from mineral fibres, weatherproof and water-resistant.Can be stored for an unlimited period of time in dry, frost-free rooms.
120 10170 23170 40
TypeKBK-1KBK-2KBK-3
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.18.00033.00063.000
Item no.720270972027257202741
PackPiece555
Steel wire grid
Steel wire grid as support and protection grid, wire diameter 4 mm.
600 5001000 600
TypeSDG-1SDG-2
Dim.Lmm
Dim. Bmm
Weightkg/100 pc.135.000270.000
Item no.72029637202971
PackPiece11
MMS-plus MS mounting rail tie, with flat pan-head
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx
TypeMMS+ MS 7.5x50MMS+ MS 7.5x60
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Weightkg/100 pc.1.5001.800
Item no.34982613498262
PackPiece10050
Calcium silicate plate
L
BD
Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.
500 150 20500 250 301000 250 30
TypeKSI-P1KSI-P2KSI-P3
Dim.Lmm
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.42.000111.000222.000
Item no.720228372029047202912
PackPiece111
Identification plate
100
70
25
Ø 7
85
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
34
Fire protection foam PYROSIT® NG System description
The PYROPLATE® NG system from OBO is used tocreate cable and combination insulation made offire protection foam. The special recipe of the 2-component foam allows simple, "pinpointed" pro-cessing. The good substrate adhesion prevents thefoam from running out of the opening. Work caneasily be interrupted to carry out checks. The sys-tem can be installed without dust and fibres. Sur-face coating is not necessary. According to the
construction approval, in addition to the cables,pipes made of steel, copper or various plasticsmay also be run through the same insulation. ThePYROSIT® NG insulation is suitable as combinationinsulation for different units. Due to the soft consis-tency, the insulation made of PYROSIT® NG can bereassigned simply. The insulation system can becombined with the PYROPLUG® Block foam block.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
36
Fire protection foam PYROSIT® NG Installation principle
Clean the layer and attach thelining aids, e.g. adhesive tape.
Apply the foam from the rear tothe front, and remove residues asnecessary.
Use approved section insulationfor metal pipes.
Electrical installation pipes up toM40, filled with cables or empty.
Combustible pipes up to Ø50 mm can be run throughwithout additional measures.
Combination insulation for variousstructures with labelling.
Application of the fire protectionfoam directly under the wall.
Labelled underfloor insulation withreserve empty pipe.
Empty pipes with tension wirescan be foamed in for assignmentat a later date.
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
37
Fire protection foam PYROSIT® NG Registration data
Combination insulation in walls/ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120
Proof of application European Technical Assessment of OIB, Vienna
Approval number ETA-11/0527
Testing standard EN 1366-3
Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-002/2012
Air permeation/pressure resistance ift Rosenheim, 11-003694-PR03
Noise insulation HfT Stuttgart, 122-007-04P-186a
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm(EI30 / EI60 / EI90 / EI120)
10 cm(EI30 / EI60 / EI90 / EI120)
15 cm(EI30 / EI60 / EI90 / EI120)
Min. insulation thickness
14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)
14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)
14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)
Opening size for 14.4 cminsulation thickness
≤ 45 cm≤ 50 cm
≤ 45 cm≤ 50 cm
≤ 45 cm≤ 45 cm
Opening size for 20cminsulation thickness
≤ 45 cm≤ 50 cm
≤ 45 cm≤ 50 cm
≤ 45 cm≤ 45 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
38
Fire protection foam PYROSIT® NG Installations
Cable
Ø 80 mm
Pipe bundle of electrical installation pipes
Ø 80 mm
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Ø 16 mm
Individual lines for control purposes
Cable support systems
Steel profiles
Electrical installation pipe made of plastic, rigid
Ø 40 mm
Metal pipes with path insulation
Steel, stainless steel andcast steel Ø 88.9 mm,copper Ø 88.9 mm
Electrical installation pipe made of plastic, flexible
Ø 40 mm
Plastic pipes
Ø 50 mm
Special installations
Cables
Ø 24 mm
Open underfloor ducts
Width max. 60 cm,height max. 16 cm
Screed-covered underfloor ducts
Width max. 35 cm,height max. 18 cm
Klimasplit
"Tubolit DuoSplit" & "TubolitSplit" or comparable6.0 mm–22.0 mm
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
39
Fire protection foam PYROSIT® NG
2-component fire protection foam PYROSIT®NG
380TypeFBS-S
Contentsml
Weightkg/100 pc.64.600
Item no.7203800
PackPiece1
PYROSIT® NG 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5°C to +30 °C for up to 12 months.
PYROSIT® Foam
380TypeFSU-F
Contentsml
Weightkg/100 pc.63.700
Item no.7203900
PackPiece1
PYROSIT® Foam 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5°C to +30 °C for up to 12 months.
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
40
Fire protection foam PYROSIT® NG
Mixer pipe set
10 mixing tubes and 5 extension tubes in the set for PYROSIT® NG fire protection foam.
TypeFBS-M
Weightkg/100 PUs10.000
Item no.7203803
PackPU1
Professional cartridge pistol
High-quality 2-component cartridge pistol for use with the PYROSIT® NG fire protection foam. The parallel move-ment of the outlet to the holding grip ensures easy working.
TypeFBS-PH
Weightkg/100 pc.120.000
Item no.7203806
PackPiece1
Battery-operated cartridge pistol
High-quality, motor-operated 2-component cartridge pistol for use with the PYROSIT® NG fire protection foam.The hard-shell case contains a FBS-PA pistol, a charging device and a rechargeable battery.
TypeFBS-PA2
Weightkg/100 pc.560.000
Item no.7203813
PackPiece1
Battery
Battery for motor-operated cartridge pistol FBS-PA2.
3 14.4TypeEA 3-14
CapacityAh
Nom.voltageV
Weightkg/100 pc.56.000
Item no.7203816
PackPiece1
Fire protection case
The PYROSIT® NG fire protection case contains all the required products to create foam insulations. The completeset consists of: 3 x FBS-S, 1 x FBS-PH, 6 mixing and 5 extension pipes.
TypeFBS-K
Weightkg/100 pc.420.000
Item no.7203809
PackPiece1
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
41
Fire protection foam PYROSIT® NG
Tempering box
When squeezing out cartridges, the right temperature is essential. In order to achieve this, a temperature controlbox is recommended.
TypeFBS-TB
Weightkg/100 pc.610.100
Item no.7203818
PackPiece1
PYROPLUG® Block foam block
Soft, permanently elastic foam block for cable and combination insulation. Vertical and transverse installation toachieve different fire resistance classes. Can be combined with the two-component fire protection foam PYROSIT®NG. Can be used in solid ceilings and walls and in light-duty partitions and is approved for many installations. CE-labelled construction product according to ETA-15/0803 for applications with fire resistance periods of up to 120minutes.Details on the applications can be found in the approval documents.Protect the surface of the foam insulation against water in order to guarantee safe expansion in the case of fire.Coating with standard silicone is approved.
200x144x60TypeFBA-B200-14
Dimen-sionmm
Weightkg/100 pc.44.800
Item no.7202505
PackPiece4
Section insulation for metal pipes
Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.
Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks
Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C
6100 500 30TypeMIW-MA
Lengthmm
Widthmm
Thicknessmm
Weightkg/100 pc.1,010.000
Item no.7202308
PackPiece2
Winding wire for path insulation
The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.
50TypeMIW-TD
Lengthm
Weightkg/100 pc.10.000
Item no.7202309
PackPiece1
Cable coil
Self-adhesive, intumescent cable protector, 5 mm thick, for the use with large cable diameters and penetratedcable support systems, applicable in PYROPLUG® systems and PYROSIT® NG.
5 150TypeFBA-WI
Lengthm
Widthmm
Weightkg/100 pc.384.000
Item no.7202510
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
42
Fire protection foam PYROSIT® NG
Adhesive tape
Fibre-reinforced, transparent adhesive tape as lining aid for applications with PYROSIT® NG fire protection foamand for universal fix. One roll contains 25 m².
25 50TypeSHT
Lengthm
Widthmm
Weightkg/100 pc.12.000
Item no.7202521
PackPiece5
Calcium silicate plate
Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.
500 150 20500 250 301000 250 30
TypeKSI-P1KSI-P2KSI-P3
Dim.Lmm
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.42.000111.000222.000
Item no.720228372029047202912
PackPiece111
L
BD
Identification plate
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
100
70
25
Ø 7
85
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
43
PYROPLUG® Block System description
The OBO PYROPLUG® Block combination insula-tion is created from foam blocks, which, if there isa fire, expand without any noticeable pressurecreation. In so doing, they form an insulating car-bon foam. This reliably prevents the penetration offire and smoke through the cable insulation. Com-bustible pipes can be run in this insulation without
an additional sleeve. Copper and steel pipes canbe insulated either with or without section insula-tion. All the PYROPLUG® Block insulation is com-pletely dust and fibre-free. This also applies to anyinstallations at a later date. This is an aspect whichis particularly important for installation in IT andlaboratory rooms.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
44
PYROPLUG® Block Installation principle
Mounting of the cut blocks.
Vacuum blocks for simple resi-dual gap closing.
Simple retroinstallation throughremoval of individual blocks.
Running of combustible pipeswithout additional measures.
Run-through, non-combustiblepipes with section insulation.
Tight-fitting installation of theblocks in the ceiling penetration.
Cut thin strips for the duct com-partments.
Close the joints and spandrelsbetween the installed cables andthe blocks with a layer of theFBA-SP fire protection compoundof at least 2 cm deep.
Close the residual joints betweencables and blocks with the FBA-SP filler.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
45
PYROPLUG® Block Registration data
Combination insulation in walls/ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120
Proof of application European Technical Assessment of OIB, Vienna
Approval number ETA-15/0803
Testing standard EN 1366-3
Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-001/2012
Air permeation/pressure resistance ift Rosenheim, 11-003694-PR02
Noise insulation HfT Stuttgart, 122-007-04P-186a
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm (EI 30 / EI 60 / EI 90/ EI 120)
10 cm (EI 30 / EI 60 / EI 90/ EI 120)
15 cm (EI 30 / EI 60 / EI 90/ EI 120)
Min. insulation thickness
14.4 cm (EI 30 / EI 60)20 cm (EI 90 / EI 120)
14.4 cm (EI 30 / EI 60)20 cm (EI 90 / EI 120)
14.4 cm (EI 30 / EI 60)20 cm (EI 90 / EI 120)
Opening size for 14.4 cminsulation thickness
≤ 100 cm≤ 60 cm
≤ 100 cm≤ 60 cm
≤ 37.5 cmUnlimited
≤ 40 cm≤ 60 cm
≤ 60 cm≤ 100 cm
≤ 60 cm≤ 100 cm
≤ 100 cm≤ 60 cm
≤ 45 cm≤ 225 cm
Opening size for 20cminsulation thickness
≤ 100 cm≤ 60 cm
≤ 100 cm≤ 60 cm
≤ 37.5 cmUnlimited
≤ 40 cmUnlimited
≤ 60 cm≤ 100 cm
≤ 60 cm≤ 100 cm
≤ 60 cm≤ 130 cm
≤ 70 cm≤ 100 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
46
PYROPLUG® Block Installations
Cable
Ø 80 mm
Pipe bundle of electrical installation pipes
Ø 80 mm cable,pipes max. Ø 40 mm
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Ø 16 mm
Individual lines for control purposes
Cable support systems
Steel profiles
Electrical installation pipe made of plastic, rigid
Ø 40 mm
Metal pipes with path insulation
Steel, stainless steel andcast steel Ø 88.9 mm,copper Ø 88.9 mm
Electrical installation pipe made of plastic, flexible
Ø 40 mm
Plastic pipes
Ø 50 mm
Special installations
Cables
Ø 24 mm
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
47
PYROPLUG® Peg foam series System description
The PYROPLUG® Peg system from OBO is used tocreate cable insulation with fire protection foamplugs. The foam plugs are ideal for closing coredrill holes in solid walls and concrete ceilings. Thefoam plugs are made of permanently elastic, clo-sed-pore foam, which expands in the event of firewithout any significant pressure build-up, thus crea-ting an insulating plastic foam. This reliably pre-
vents the penetration of fire and smoke through thecable insulation. The PYROPLUG® Peg insulationsystem can be used without difficulty in areas ofdata processing and in laboratories, as mounting iscompletely clean and is free or dust and fibres.This also applies to any necessary cable installati-ons at a later date. Special tools are not requiredfor processing, a knife is sufficient.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
48
PYROPLUG® Peg foam series Installation principle
Ideal for core drill holes of55 mm to 240 mm.
Cutting of the plugs for cableassignment on the edge of thecore hole.
Push cut plugs into the core hole.
Due to the elastically material aquick mounting is possible.
Cutting and mounting of the plugsin ceilings.
Residual joints are closed off withthe filler FBA-SP.
Small distance to next core drillhole possible.
With retroinstallations, carefullycut or drill the plugs.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
49
PYROPLUG® Peg foam series Registration data
Combination insulation in walls/ceilingsFire resistance class EI 30, EI 45, EI 60, EI 90, EI 120
Proof of application European Technical Assessment of OIB, Vienna
Approval number ETA-15/0701
Testing standard EN 1366-3
Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-001/2012
Air permeation/pressure resistance ift Rosenheim, 11-003694-PR01
Noise insulation HfT Stuttgart, 122-007-04P-186a
Installation locationsInsulation in walls and ceilings
Component F30 Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)
10 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)
15 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)
Min. insulation thickness
>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)
>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)
>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)
Opening size
Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm
Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm
Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
50
PYROPLUG® Peg foam series Installations
Cable
Ø 80 mm
Pipe bundle of electrical installation pipes
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Ø 16 mm
Individual lines for control purposes
Cable support systems
Steel profiles
Electrical installation pipe made of plastic, rigid
Ø 16 mm
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Ø 16 mm
Plastic pipes
Special installations
Cables
Ø 24 mm
Insulation in the lining pipe
PE-HD pipe(ceiling)
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
51
PYROPLUG® Box box insulationSystem description
The PYROPLUG® Box system from OBO is used tocreate cable insulation with boxes made of foam.The system is particularly suitable for simple moun-ting of cable insulation in light-duty partitions. Nolayering is required. Installation in solid walls andsolid ceilings is also possible and approved. Theinsulation system consists of a two-part frame andtwo matching internal pieces. The permanently ela-
stic, closed-pore foam material expands in theevent of fire without any significant pressure build-up, thus creating an insulating plastic foam. Thisreliably prevents the penetration of fire and smokethrough the cable insulation. The usable area of theboxes corresponds to the maximum approval cableassignment area of 60%. It is thus impossible toover assign it with cables.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
52
PYROPLUG® Box box insulationInstallation principle
Insertion of the split frame in light-duty partitions, without additionallayering.
Mounting of the frame with pre-viously installed cables.
Exact cutting of the internal pie-ces and then insertion in theframe.
Closing joint component on fullassignment with FBA-SP filler.
Grouped arrangement of theboxes.
Classification to DIN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
53
PYROPLUG® Box box insulationRegistration data
Insulation in wall/ceilingFire resistance class S30, S60, S90
Proof of application General construction approval of DIBt, Berlin
Approval number Z-19. 15-1557
Testing standard DIN 4102 Part 9
Installation locationsInsulation in walls and ceilings
Component F30 Rigid walls Flexible walls Rigid floors
Min. component strength
5 cm(S30 / S60 / S90)
7.5 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
20 cm(S30 / S60 / S90)
20 cm(S30 / S60 / S90)
20 cm(S30 / S60 / S90)
Opening size
≤ 50 cm≤ 50 cm
≤ 50 cm≤ 50 cm
≤ 50 cm≤ 50 cm
Component F90 Screed-covered
Rigid walls
Flexible walls Rigid floors
Min. component strength
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
20 cm(S30 / S60 / S90)
20 cm(S30 / S60 / S90)
20 cm(S30 / S60 / S90)
Opening size
≤ 50 cm≤ 50 cm
≤ 50 cm≤ 50 cm
≤ 50 cm≤ 50 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
54
PYROPLUG® Box box insulationInstallations
Cable
All Ø
Pipe bundle of electrical installation pipes
Cable bundle
Ø 100 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Individual lines for control purposes
Ø 15 mm
Cable support systems
Profiles made of steel, alumi-nium or plastic
Electrical installation pipe made of plastic, rigid
Ø 20 mm
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Ø 20 mm
Plastic pipes
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
55
PYROPLUG® Shell pipe shellsSystem description
The OBO PYROPLUG® Shell system is speciallydesigned for cable insulation in box drill holes inlight-duty partitions. The insulation system consistsof a pipe shell and two matching plugs. The mate-rial is made of permanently elastic, closed-porefoam, which expands in the event of fire withoutany significant pressure build-up, thus creating an
insulating plastic foam. This reliably prevents thepenetration of fire and smoke through the cableinsulation. The ratio of the external diameter to theinternal diameter of the pipe shell ensures that overassignment with cables is not possible, even at fullassignment.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
56
PYROPLUG® Shell pipe shellsInstallation principle
Drilling of a hole with a drillcrown.
Grouped arrangement of the drillholes.
Insertion of the pipe shell in thelight-duty partition.
For previously installed cables,cutting of the pipe shell.
Cutting and insertion of the plugsin the pipe shell.
Full assignment of the pipe shell.
Classification to DIN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
57
PYROPLUG® Shell pipe shellsRegistration data
Insulation in wall / ceilingFire resistance class S30, S60, S90
Proof of application General construction approval of DIBt, Berlin
Approval number Z-19. 15-1559
Testing standard DIN 4102 Part 9
Installation locationsInsulation in walls and ceilings
Component F30 Rigid walls Flexible walls Rigid floors
Min. component strength
5 cm(S30 / S60 / S90)
7.5 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
Opening size
≤ Ø 10 cm ≤ Ø 10 cm ≤ Ø 10 cm
Component F90 Screed-covered
Rigid walls
Flexible walls Rigid floors
Min. component strength
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
Opening size
≤ Ø 10 cm ≤ Ø 10 cm ≤ Ø 10 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
58
PYROPLUG® Shell pipe shellsInstallations
Cable
All Ø
Pipe bundle of electrical installation pipes
Cable bundle
Electrical installation pipe made of steel
Individual lines for control purposes
Ø 15 mm
Cable support systems
Profiles made of steel, alumi-nium or plastic
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Plastic pipes
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
59
PYROPLUG® Mini filler System description
The OBO PYROPLUG® Mini system is ideal forsmall, round cable insulations up to a diameter of8 cm. It only consists of the one-component fillerPYROPLUG® Screed. In light-duty partitions, the
empty mini pipe shell of the PYROPLUG® Shell sys-tem is used as layering. The interior of these pipeshells may be completely assigned. Only the resi-dual joints must be filled with the filler.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
60
PYROPLUG® Mini filler Installation principle
Closing of the opening with the fil-ler FBA-SP.
In light-duty partitions, use of themini pipe shell FBA-DR.
Complete assignment of the minipipe shell.
Classification to DIN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
61
PYROPLUG® Mini filler Registration data
Insulation in wall/ceilingFire resistance class S30, S60, S90
Proof of application General construction approval of DIBt, Berlin
Approval number Z-19. 15-1851
Testing standard DIN 4102 Part 9
Installation locationsInsulation in walls and ceilings
Component F90 Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
10 cm(S30 / S60 / S90)
10 cm(S30 / S60 / S90)
15 cm(S30 / S60 / S90)
Opening size
≤ Ø 8 cm ≤ Ø 8 cm ≤ Ø 8 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
62
PYROPLUG® Mini filler Installations
Cable
Ø 18 mm
Pipe bundle of electrical installation pipes
Cable bundle
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Plastic pipes
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
63
PYROPLUG® foam series
PYROPLUG® Block foam block
Soft, permanently elastic foam block for cable and combination insulation. Vertical and transverse installation toachieve different fire resistance classes. Can be combined with the two-component fire protection foam PYROSIT®NG. Can be used in solid ceilings and walls and in light-duty partitions and is approved for many installations. CE-labelled construction product according to ETA-15/0803 for applications with fire resistance periods of up to 120minutes.Details on the applications can be found in the approval documents.Protect the surface of the foam insulation against water in order to guarantee safe expansion in the case of fire.Coating with standard silicone is approved.
200x144x60TypeFBA-B200-14
Dimen-sionmm
Weightkg/100 pc.44.800
Item no.7202505
PackPiece4
PYROSIT® Blocks
Foam block for cable and combination insulation in accordance with UL listings. Also approved in combination withthe fire protection foam PYROSIT® foam.The block contains a glass fabric for stabilisation in the event of fire, meaning that no additional measures are requi-red on the insulation surface, e.g. protective mesh.
200x130x60TypeFSU-B7.9
Dimen-sionmm
Weightkg/100 pc.55.000
Item no.7203903
PackPiece4
PYROPLUG® Block vacuum block
Vacuum-packed version of the FBA-B200-14 foam block for the simple closure of the residual gap in thePYROPLUG® Block combination insulation. After mounting has been completed, the film is cut and the blockexpands to its original size again. The film can remain in the insulation.
200x144x25TypeFBA-BV200-14
Dimen-sionmm
Weightkg/100 pc.40.000
Item no.7202515
PackPiece1
2-component fire protection foam PYROSIT®NG
PYROSIT® NG 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5 °C to +30°C for up to 12 months.
380TypeFBS-S
Contentsml
Weightkg/100 pc.64.600
Item no.7203800
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
64
PYROPLUG® foam series
PYROPLUG® Peg plugs
Plug for cable insulationProtect the FBA plugs against water in order to guarantee safe foaming in case of fire.
55 - 65 75 6568 - 78 87 7897 - 107 117 107112 - 122 132 122124 - 134 144 134155 - 165 175 165190 - 200 210 200240 - 250 260 250
TypeFBA-SN65FBA-SN78FBA-SN107FBA-SN122FBA-SN134FBA-SN165FBA-SN200FBA-SN250
ForopeningØ mm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.8.20012.60021.60028.60032.90049.70074.400101.400
Item no.72025537202557720256172025657202569720257372025777202581
PackPiece44444222
PYROSIT® Plugs
Plug for cable insulationProtect the FBA plugs against water in order to guarantee safe foaming in case of fire.
63 6576 78101 107114 122127 134
TypeFSU-P2.5FSU-P3FSU-P4FSU-P4.5FSU-P5
ForopeningØ mm
Dim. Dmm
Weightkg/100 pc.14.50018.70033.00043.00049.500
Item no.72039097203912720391572039197203921
PackPiece44444
PYROPLUG® Box box insulation
Box for cable insulation.Consisting of a two-part, hard frame and two soft internal pieces. Protect the frame and internal pieces againstwater in order to guarantee safe foaming in case of fire.
200x200x100TypeFBA-F
Dimen-sionmm
Weightkg/100 pc.122.000
Item no.7202660
PackPiece1
200200170
200
10040
PYROPLUG® Shell drill crown insulation
Pipe shell for cable insulationConsisting of a one-part, hard pipe sleeve and two soft plugs of 50 mm diameter. Protect the pipe sleeves andplugs against water in order to guarantee safe foaming in case of fire.
100150
TypeFBA-D100FBA-D150
Dim.Lmm
Weightkg/100 pc.15.50019.200
Item no.72026247202628
PackPiece11
Empty mini pipe shell
Empty pipe sleeve for use in FBA-SP small insulation in lightweight partitions.Protect the pipe sleeves against water in order to guarantee safe foaming in case of fire.
100150
TypeFBA-DR100FBA-DR150
Dim.Lmm
Weightkg/100 pc.6.50010.200
Item no.72026137202617
PackPiece11
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
65
PYROPLUG® foam series
PYROPLUG® screed filler
Fire protection filler in a cartridge.Usable as small insulation and as joint closing compound in all insulation of the PYROPLUG® series.In dry, frost-free rooms, the fire protection filler can be stored for up to 12 months at a temperature of +5 °C to +30°C.
310TypeFBA-SP
Contentsml
Weightkg/100 pc.46.000
Item no.7202322
PackPiece1
PYROSIT® Sealant
Fire protection filler in a cartridge.Fire protection filler in a cartridge as joint closing compound in accordance with UL listings.In dry, frost-free rooms, the fire protection filler can be stored for up to 12 months at a temperature of +5 °C to +30°C.
310TypeFSU-M
Contentsml
Weightkg/100 pc.50.000
Item no.7203906
PackPiece1
Steel wire grid
Steel wire grid as support and protection grid, wire diameter 4 mm.
600 5001000 600
TypeSDG-1SDG-2
Dim.Lmm
Dim. Bmm
Weightkg/100 pc.135.000270.000
Item no.72029637202971
PackPiece11
MMS-plus MS mounting rail tie, with flat pan-head
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx
TypeMMS+ MS 7.5x50MMS+ MS 7.5x60
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Weightkg/100 pc.1.5001.800
Item no.34982613498262
PackPiece10050
Section insulation for metal pipes
Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.
Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks
Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C
6100 500 30TypeMIW-MA
Lengthmm
Widthmm
Thicknessmm
Weightkg/100 pc.1,010.000
Item no.7202308
PackPiece2
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
66
PYROPLUG® foam series
Aluminium adhesive tape for path insulation
Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.
100 100TypeMIW-AT
Lengthm
Widthmm
Weightkg/100 pc.136.900
Item no.7202305
PackPiece1
Winding wire for path insulation
The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.
50TypeMIW-TD
Lengthm
Weightkg/100 pc.10.000
Item no.7202309
PackPiece1
Cable coil
Self-adhesive, intumescent cable protector, 5 mm thick, for the use with large cable diameters and penetratedcable support systems, applicable in PYROPLUG® systems and PYROSIT® NG.
5 150TypeFBA-WI
Lengthm
Widthmm
Weightkg/100 pc.384.000
Item no.7202510
PackPiece1
Calcium silicate plate
Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.
500 150 20500 250 301000 250 30
TypeKSI-P1KSI-P2KSI-P3
Dim.Lmm
Dim. Bmm
Dim. Dmm
Weightkg/100 pc.42.000111.000222.000
Item no.720228372029047202912
PackPiece111
L
BD
Identification plate
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanEnglishSwedishSpanishEnglishCroatian
TypeKS-S DEFSU-IPKS-S SEKS-S ESKS-S ENKS-S HR
Language Weightkg/100 pc.2.4002.0002.4002.4002.4002.400
Item no.720542572039247205426720542772054297205438
PackPiece1101111
100
70
25
Ø 7
85
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
67
PYROCOMB® pipe sleeveSystem description
The PYROCOMB® system can be used as indepen-dent pipe sealing for combustible pipes (e.g. sani-tary wastewater pipes). It is primarily made up ofthe pipe sleeves, type TCX. In the event of fire, thefire protection material inserted within the sealfoams up after a few minutes under high pressure,closing the soft plastic pipes. This safely prevents
the spread of fire and smoke, should a fire occur.With wall mounting, the pipe sleeves are mountedon both sides of the wall with metal anchors. Cei-ling penetrations only have a tube seal from theunderside. In light-duty partitions, the pipe sleevesare fastened on passed-through threaded rods andconnected together.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
68
PYROCOMB® pipe sleeveInstallation principle
Two-sided arrangement of thepipe sleeves for wall mounting.
Mounting on the underside of theceiling with metal anchors.
Sloping pipe penetration up to anangle of 39°.
Pipe sleeves in the area of thepenetration.
Eccentric arrangement with max.3 levels of larger pipe sleeves.
Pipe post systems with 2 accom-panying cables.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
69
PYROCOMB® pipe sleeveRegistration data
Pipe insulation in underfloor ductsFire resistance class El 15, El 30, El 45, El 60, El 90, El 120, El 180, El 240
Proof of application General construction approval of OIB, Vienna
Approval number ETA-12/0182
Testing standard EN 1366-3
Installation locationsPipe insulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm (EI 30 / EI 60 / EI 90/ EI 120 / EI 240)
10 cm (EI 30 / EI 60 / EI 90/ EI 120)
15 cm (EI 30 / EI 60 / EI 90/ EI 120)30 cm (EI 180 / EI 240)
Min. insulation thickness
10 cm (EI 30 / EI 60 / EI 90/ EI 120 / EI 240)
10 cm (EI 60 / EI 90 / EI120)
15 cm (EI 30 / EI 60 / EI 90/ EI 120)30 cm (EI 180 / EI 240)
Opening size
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
70
PYROCOMB® pipe sleeveInstallations
Cable
Pipe bundle of electrical installation pipes
Cable bundle
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Plastic pipes
Ø 400 mm
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
71
PYROCOMB® Tubes pipe sleeve System description
The PYROCOMB® Tubes system is used to createcable insulation with pipe sleeves. The systemcomprises multiple sizes of the pipe sleeve, typeTCX. This allows simple insulation of bundles ofplastic electrical installation pipes, rigid or flexible,up to a size of M63. It is irrelevant whether the
pipes are filled with cables or are empty. In theevent of fire, the fire protection material insertedwithin the seal foams up after a few minutes underhigh pressure, closing the softened bundles at ahigh pressure. This safely prevents the spread offire and smoke, should a fire occur.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
72
PYROCOMB® Tubes pipe sleeve Installation principle
Two-sided arrangement of thepipe sleeves for wall mounting.
Mounting on the underside of theceiling with metal anchors.
Closing of the ring gap with theinsulation layer creator DSX.
Combination of the sleeve halvesand fastening on the wall.
Closing of the pipe ends with theinsulation layer creator DSX.
Labelled insulation of installationpipe bundles.
Classification to DIN
Classification to EN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
73
PYROCOMB® Tubes pipe sleeve Registration data
Combination insulation in walls and ceilingsFire resistance class El 15, El 30, El 45, El 60, El 90, El 120
Proof of application General construction approval of OIB, Vienna
Approval number ETA-12/0207
Testing standard EN 1366-3
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm (EI 30 / EI 60 / EI 90/ EI 120)
10 cm (EI 30 / EI 60 / EI 90/ EI 120)
15 cm (EI 30 / EI 60 / EI 90/ EI 120)
Min. insulation thickness
10 cm (EI 60 / EI 90 / EI120)
10 cm (EI 60 / EI 90 / EI120)
15 cm (EI 60 / EI 90 / EI120)
Opening size
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm
Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
74
PYROCOMB® Tubes pipe sleeve Installations
Cable
Pipe bundle of electrical installation pipes
Ø 125 mm
Cable bundle
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Ø 63 mm,cable Ø 21 mm
Plastic pipes
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
75
PYROCOMB® pipe sleeve
Pipe sleeve with 2 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M6 threaded rods.
32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54
TypeTCX-032TCX-040TCX-050
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.6.5007.0008.000
Item no.720220072022017202203
PackPiece111
Pipe sleeve with 4 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.
63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129
TypeTCX-063TCX-075TCX-090TCX-110TCX-125
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.15.50019.00037.00046.00070.000
Item no.72022047202205720220672022077202208
PackPiece11111
Pipe sleeve with 6 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
140 - 142 40 200 144160 - 162 40 220 164
TypeTCX-140TCX-160
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.106.000107.000
Item no.72022097202210
PackPiece11
Pipe sleeve with 8 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
180 - 182 40 264 184200 - 202 40 284 204
TypeTCX-180TCX-200
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.175.000242.000
Item no.72022127202214
PackPiece11
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
76
PYROCOMB® pipe sleeve
Pipe sleeve with 10 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
225 - 227 51.5 328 239250 - 252 51.5 353 264
TypeTCX-225TCX-250
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.306.000346.000
Item no.72022137202215
PackPiece11
Pipe sleeve with 12 fastening straps
Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.
280 - 282 51.5 378 289300 - 302 51.5 403 314315 - 317 51.5 417 328355 - 357 51.5 459 370400 - 402 51.5 504 415
TypeTCX-280TCX-300TCX-315TCX-355TCX-400
PipeØmm
Dim. hmm
Dim. Dmm
Dim.dmm
Weightkg/100 pc.398.000405.000425.000460.000520.000
Item no.72022167202217720221872022197202220
PackPiece11111
Insulation layer creator in a cartridge
Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for the closing of core drill holes when feeding through single cables and for closing the annular gap whenexiting cables from the PYROLINE® Con PLC fire protection duct. Material class DIN 4102 - B2, normally flam-mable. In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.
300TypeDSX-K
Contentsml
Weightkg/100 pc.50.000
Item no.7202300
PackPiece1
Threaded rod
Threaded rod to DIN 976.
M6 6 1000M8 8 1000
TypeTR M6 1M GTR M8 1M G
Thread
Dim.dmm
Dim.Lmm
Weightkg/100 pc.18.30030.000
Item no.31410473141128
PackPiece1010
Hexagonal nut DIN 934
Hexagonal nut to DIN 934 with metric thread.
M6 10 5.2 6M8 13 6.8 8
TypeHN M6 GHN M8 G
ThreadSWmm
Dim. hmm
Dim.dmm
Weightkg/100 pc.0.2210.500
Item no.34000693400085
PackPiece100100
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
77
PYROCOMB® pipe sleeve
Washer ISO 7093
Washer of large outer diameter for universal use.
M6 6.5 28 2.5M8 8.5 28 2.5
TypeWS M6 D28 GWS M8 D28 G
Thread
Dim.dmm
Dim. Dmm
Dim. hmm
Weightkg/100 pc.1.1041.100
Item no.34022073402215
PackPiece100100
MMS-plus P round head tie, with panhead
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With roundhead for universal fastenings. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
6 x 50 5 11.2 Torx 50TypeMMS+ P 6x50
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Dim.Lmm
Weightkg/100 pc.1.000
Item no.3498108
PackPiece100
MMS-plus MS mounting rail tie, with flat pan-head
Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.
7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx
TypeMMS+ MS 7.5x50MMS+ MS 7.5x60
Dimen-sionmm
DrillholeØmm
Head Ømm
Screw system
Weightkg/100 pc.1.5001.800
Item no.34982613498262
PackPiece10050
Nail anchor N with thread
L
The nail anchor N can be used for multiple fastenings of non-load-bearing systems and in cracked and non-cracked concrete, thereby combining the benefits of a bolt tie with even easier mounting.The nail tie only needs to be hammered into the drill hole. It is not necessary to apply torque subsequently. Whenthe load occurs, the nail tie spreads itself and bolts itself in the drill hole.
M6 6 5 - 10 49TypeN 6-5-10/49
Thread
DrillholeØmm
Clampingrangemm
Dim.Lmm
Weightkg/100 pc.1.160
Item no.3498396
PackPiece100
Bolt tie BZ-U
Bolt tie BZ for the anchoring of medium-duty to heavy-duty loads, both in cracked and non-cracked concrete. Itcombines high approved loads with small edge distances and axial spacings.
M8 75TypeBZ-U 8-10-21/75
Thread
Dim.Lmm
Weightkg/100 pc.3.460
Item no.3498320
PackPiece50
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
78
PYROCOMB® pipe sleeve
Mineral wool
Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.
25 LiterTypeMIW-S
Dimension Weightkg/100 pc.250.000
Item no.7202306
PackPiece1
Identification plate
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
100
70
25
Ø 7
85
Support construction for insulations, withbracket
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.
70 217 50TypeSKA 05 VZ
Dim.Hmm
Dim. Bmm
Dim.Amm
Weightkg/100 pc.190.740
Item no.7202436
PackPiece1
Support construction for insulations, with pen-dulum suspension
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.
1000TypeSKP 05 VZ
Dim.Lmm
Weightkg/100 pc.235.240
Item no.7202446
PackPiece1
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
79
PYROCOMB® Intube pipe shellSystem description
The PYROCOMB® Intube system is used to createcable insulation with pipe shells or half shells. Thepipe shell is particularly suitable for core drill holesand can very easily be installed in solid ceilings orwalls and also light-duty partitions. For this, two halfpipe sleeves are clicked together and bedded inmortar in the core hole. Then the pipe sleeves areclosed with seals and the surface is sealed withASX ablation coating. The cables don't require any
coating. The half shell can be used particularly wellin the underfloor area. It is sealed on one side withfire protection plugs and sealed with ASX ablationcoating. In case of a fire, the inner coating of thepipe shell or the half shell expands and, in sodoing, closes the opening cross-section comple-tely. The transfer of fire and smoke is thus safelyprevented. With the PYROCOMB® Intube system,100% assignment of the interior is possible.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
80
PYROCOMB® Intube pipe shellInstallation principle
Mounting of the pipe shell byclicking the half shells togetheraround the existing installation.
Closing of the opening withPYROMIX® mortar.
Adjust the foam plugs to installati-ons using a knife and createsmoke gas-tight sealing of thesealings using the ASX coatingcompound.
With ceiling mounting, use a linedbody to prevent the pipe shellfrom falling out.
In certain applications, securitywith metal tensioning straps inlight-duty partitions is necessary.
Pipe shells with full assignmentwith cable bundles and electricalinstallation pipes.
Mounting of the half shell.
Adjusting the foam plug to thecables.
Fully installed half shell inPYROPLATE® Fibre soft insula-tion.
Classification to DIN
Erectors of combination insulation require training.Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
81
PYROCOMB® Intube pipe shellRegistration data
Insulation in wall/ceilingFire resistance class El 60, El 90, El 120
Proof of application General construction approval of OIB, Vienna
Approval number ETA - 13/0904
Testing standard EN 1366-3
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150
10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150
12.5 cm(EI 30 / EI 45 / EI 60)CTS-150
15 cm - 30 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
10 cm - 15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
Min. insulation thickness
10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150
10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150
12.5 cm(EI 30 / EI 45 / EI 60)CTS-150
15 cm - 30 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
10 cm - 15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300
Opening size
Ø 125 mm Ø 125 mm Ø 125 mm
55 mm x 116 mm 55 mm x 116 mm 55 mm x 116 mm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
82
PYROCOMB® Intube pipe shellInstallations
Cable
Ø 80 mm
Pipe bundle of electrical installation pipes
Ø 107 mm
Cable bundle
Ø 107 mm,cable Ø 21 mm
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
Ø 32 mm,cable Ø 21 mm
Plastic pipes
2 × Ø 32 mm
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
83
Pipe shell PYROCOMB® Intube
PYROCOMB® Intube pipe shell, Ø 60 mm
Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.
150 60 50.6 65TypeCTS 06150
Dim.Lmm
Dim. Bmm
Dim. Dmm
ForopeningØ mm
Weightkg/100 pc.17.500
Item no.7204290
PackPiece1
PYROCOMB® Intube pipe shell, Ø 90 mm
Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.
150 90 80.6 100300 90 80.6 100
TypeCTS 09150CTS 09300
Dim.Lmm
Dim. Bmm
Dim. Dmm
ForopeningØ mm
Weightkg/100 pc.27.50054.000
Item no.72042927204296
PackPiece11
PYROCOMB® Intube pipe shell, Ø 120 mm
Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.
150 116.4 107 125300 116.4 107 125
TypeCTS 12150CTS 12300
Dim.Lmm
Dim. Bmm
Dim. Dmm
ForopeningØ mm
Weightkg/100 pc.35.20070.000
Item no.72043007204304
PackPiece11
PYROCOMB® Intube half shell
Internally coated half shell, the inner space of which can be fully assigned with cables and electrical installationpipes. CE-labelled, European approved construction product according to ETA-13/0904 and German general typeapproval. Fire resistance up to 120 minutes.Closing with foam plug included in the delivery. The surface seal is created with PYROCOAT® ASX coating. Thesystem is particularly suitable for underfloor areas.Details can be found in the mounting instructions/approval.
106 200 118TypeCTS-HP200
Dim. Dmm
Dim.Lmm
Dim. Bmm
Weightkg/100 pc.20.000
Item no.7204306
PackPiece1
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
84
Pipe shell PYROCOMB® Intube
Ablation coating PYROCOAT® in a cartridge
Combined, endothermic and weatherproof coating for internal and external areas. Universal protection coating forcable and cable support structures. Use as direct filler, and as paint when stirred.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.
310TypeASX-K
Contentsml
Weightkg/100 pc.50.000
Item no.7202310
PackPiece1
Ablation coating PYROCOAT® in a bucket
Combined, endothermic and weatherproof coating for internal and external areas. Universal protection coating forcable and cable support structures. Use as direct filler, and as paint when stirred. Sufficient for an area of 4 m².Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.
5TypeASX-E
Contentskg
Weightkg/100 pc.500.000
Item no.7202312
PackPiece1
PYROMIX® dry mortar in bucket
Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pressing and formanual installation. Adding approx. 3 litres of water to 10 kg of dry mortar produces about 10 litres of workablecompound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.
10TypeMSX-E1
Contentskg
Weightkg/100 pc.1,000.000
Item no.7206058
PackPiece1
PYROMIX® dry mortar in paper sack
Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pressing and formanual installation. Adding approx. 6 litres of water to 20 kg of dry mortar produces about 20 litres of workablecompound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.
20TypeMSX-S1
Contentskg
Weightkg/100 pc.2,000.000
Item no.7206104
PackPiece1
Metal strip clips, narrow
Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing.
450 7TypeMBS 045
Lengthmm
Widthmm
Weightkg/100 pc.0.602
Item no.7203104
PackPiece50
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
85
Pipe shell PYROCOMB® Intube
Identification plate
100
70
25
Ø 7
85
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
86
PYROMIX Screed® small insulation System description
Small insulation for cables is created using thePYROMIX® Screed system. It consists of OBO'sinsulation forming material, type DSX, and the MIWmineral wool. As the insulation basis, the openingis first filled using the non-combustible mineralwool (melting point ≥ 1,000 °C). Then, both sides
of the opening are sealed with the DSX insulationcreator. If there is a fire, the filler foams up, preven-ting penetration by fire and smoke. When the mate-rial foams up, heat is also drawn from the cables,thus considerably reducing the transfer of heat viathe copper cores.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
88
PYROMIX Screed® small insulation Installation principle
Mineral wool with melting point ≥1,000 °C to plug the opening.
Closure of the surfaces on bothsides with the DSX insulationlayer creator.(Minimum thickness 1 cm oneach side.)
Labelling of the small insulation.
Classification to DIN
Erectors of combination insulation require training.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
89
PYROMIX Screed® small insulation Registration data
Insulation in walls/ceilingsFire resistance class S30, S60, S90
Proof of application General type approval of the DIBt, Berlin
Approval number Z-19.53-2314
Testing standard DIN 4102 Part 9
Installation locationsInsulation in walls and ceilings
Component Rigid walls Flexible walls Rigid floors
Min. component strength
10 cm(S30/S60/S90)
10 cm(S30/S60/S90)
15 cm(S30 / S60 / S90)
Min. insulation thickness
10/15 cm(S30/S60/S90)
10/15 cm(S30/S60/S90)
15 cm(S30 / S60 / S90)
Opening size
≤ 35 cm≤ 15 cm
≤ Ø 15 cm
≤ 35 cm≤ 15 cm
≤ Ø 15 cm
≤ 15 cm≤ 15 cm
≤ Ø 15 cm
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
90
PYROMIX Screed® small insulation Installations
Cable
All Ø
Pipe bundle of electrical installation pipes
≤ 100 mm ØElR ≤ 32 mm Ø
Cable bundle
≤ 100 mm ØCable ≤ 21 mm Ø
Electrical installation pipe made of steel
Individual lines for control purposes
Cable support systems
Electrical installation pipe made of plastic, rigid
Metal pipes with path insulation
Electrical installation pipe made of plastic, flexible
≤ 32 mm Ø
Plastic pipes
Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
91
Small insulation, bandage and individual cables acc. to MLAR
Insulation layer creator in a cartridge
Dispersion-based fire protection compound for interior areas, to fill residual joints and closeopenings. Approved material for the closing of core drill holes when feeding through singlecables and for closing the annular gap when exiting cables from the PYROLINE® Con PLCfire protection duct. Material class DIN 4102 - B2, normally flammable. In dry, frost-freerooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.
300TypeDSX-K
Contentsml
Weightkg/100 pc.50.000
Item no.7202300
PackPiece1
Mineral wool
Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.
25 LiterTypeMIW-S
Dimension Weightkg/100 pc.250.000
Item no.7202306
PackPiece1
Bandage for insulation
Fire protection bandage coated with a substance on one side that foams up in the event of fire. It can be used to wrapinstallations in PYROMIX® dry mortar or PYROPLATE® Fibre plate insulations.
10 125TypeFSB-WB 1.5
Lengthm
Widthmm
Weightkg/100 pc.220.000
Item no.7203163
PackPiece1
Identification plate
100
70
25
Ø 7
85
Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.
GermanSwedishSpanishEnglishCroatianEnglish
TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP
Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000
Item no.720542572054267205427720542972054387203924
PackPiece1111110
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
92
Small insulation, bandage and individual cables acc. to MLAR
Support construction for insulations, withbracket
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.
70 217 50TypeSKA 05 VZ
Dim.Hmm
Dim. Bmm
Dim.Amm
Weightkg/100 pc.190.740
Item no.7202436
PackPiece1
Support construction for insulations, with pen-dulum suspension
Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.
1000TypeSKP 05 VZ
Dim.Lmm
Weightkg/100 pc.235.240
Item no.7202446
PackPiece1
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Insu
latio
n –
mai
nten
ance
of t
he fi
re s
ectio
ns
93
Cable bandages – prevention ofthe spread of fire
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
94
Cable bandages – prevention ofthe spread of fire
Cable bandages 100
PYROLINE® Wet FSB-WB industry/exterior areas 98
PYROWRAP® Wet FSB-WLS wet rooms/interior areas 96
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
95
PYROWRAP® Wet FSB-WLSApplication in interior areas and wet roomsSystem description
The PYROWRAP® Wet FSB-WLS system can beused to wrap large cable bundles or cable supportsystems within the fire sections, in order to preventthe spread of a fire. The mesh possesses a fireprotection coating, which stops a fire in its tracks atan early stage, e.g. in the case of a short circuit. Ifthere is fire coming in from the outside, the mate-rial is not involved in the course of the fire, effec-tively preventing the spread of the fire, both in verti-cal and horizontal directions.
In the escape and rescue routes of small buildings,the mounting of a cable bandage is permitted, asonly low smoke development is to be expectedand only a small number of people must be eva-cuated. In larger buildings, the residual risk ofsmoke development is accepted, even if considera-bly more people must be evacuated. Here, the fireprotection bandage frequently presents the onlyeconomic solution compared to fire protection cei-lings or panelling with plate materials.
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
96
PYROWRAP® Wet FSB-WLSApplication in interior areas and wet roomsInstallation principle
Complete encasement of the sus-pended cable run.
Complete encasement of thecables in a cable run as wallmounting.
Bandage fastening with metallicrails in a single-clip installation.
Bandage fastening with metallictightening straps in a rail installa-tion.
Cable exit with bandaging.
Bandaging of the cable bundleson support systems.
Cable jacketing to prevent fire spread
Proof of application Application approval of DIBt BerlinMaterial approval of DIBt Berlin
Documents Z-56.217-3600Z-19.11-2183
Prevention of fire spread min. 90 minutes
Material properties Exterior grey glass fibre mesh, interior light greymaterials class C-s2, d0 according to EN 13501-1 – hardly flammable
Max. fastening spacing 0.5 m
Cable types and cross-sections No restriction
Caution!Use in emergency and escape routes of building classes 4 and 5 may require the approval of the con-struction supervision, e.g. through a fire protection concept.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
97
PYROWRAP® Wet FSB-WBApplication in industrial areas/outdoorsSystem description
The PYROWRAP® Wet FSB-WB system comprisesa fire protection bandage, which is used in areaswith special environmental conditions. The fire pro-tection bandage can be used to wrap large cablebundles or cable support systems, in order to pre-vent the spread of fire. The bandage is made of aweatherproof material, which is insensitive to
various chemicals and oils. It has constructionapproval from the DIBt as a highly flame-resistantmaterial according to DIN EN 13501-1. When thefire protection coating foams up in the event of fire,this safely prevents the spread of fire via thecables.
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
98
PYROWRAP® Wet FSB-WBApplication in industrial areas/outdoorsInstallation principle
Use of the bandage in aggressiveenvironments, e.g. offshore.
Bandaged rising section in thetower of a wind power plant.
Use on support systems in supplyrooms or production halls.
Cable tunnel with bandages inpower stations.
Bandaged cable support systemsin areas with many combustiblematerials.
Use for photovoltaic cables runover a fire wall.
Cable jacketing to prevent fire spread
Proof of application IEC test report of the iBMB MPA materials testing institute, BraunschweigNational and European material approval of DIBt Berlin
Document no.IEC-3630/081/10-ARZ-19.11-1971ETA-13/0158
Prevention of fire spread min. 120 minutes
Material propertiesExterior grey glass fibre mesh, interior redMaterials class EN 13501-1: B1, d0,s1 – hardly flammableWeather-resistant, resistant to various chemicals and oils
Max. fastening spacing 0.5 m
Cable types and cross-sections No restriction
Caution!The use of photovoltaic cables over fire walls may require the approval of the local construction authori-ties. A positive special report is available.
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
99
Cable bandages
Cable bandage for dry areas
10 1100TypeFSB-WLS
Lengthm
Widthmm
Weightkg/100 pc.1,000.000
Item no.7203170
PackPiece1
Fire protection jacketing made of flexible mesh with fire protection coating to prevent fire spreading viacables and cable support systems. If there is a fire, the bandage only creates very little smoke, and isthus approved by the MBO building regulations as a measure for improved behaviour in case of fire inbuilding classes 1 to 3. Hardly-flammable substance, according to EN 13501-1 - Class C-s2, d0). Exter-nal side grey, internal side light grey. Can be moist wiped, use in interiors and wet rooms. One roll con-tains 11 m², nominal thickness 0.7 mm.
Cable bandage for wet areas
20 1100TypeFSB-WB
Lengthm
Widthmm
Weightkg/100 pc.2,200.000
Item no.7203160
PackPiece1
Waterproof fire protection jacketing made of flexible mesh with fire protection coating to prevent firespreading via cables and cable support systems. External side grey, internal side red. One roll contains22 m².
Complete set
550 380550 880
TypeFSB-K32FSB-K82
Lengthmm
Widthmm
Weightkg/100 pc.96.000213.000
Item no.72031507203154
PackPiece11
Complete set for covering cable bundles or cable support systems without lid to prevent fire spreading.Application in outdoor areas. Each of the sets contains 4 sections of the weather-resistant cable bandageFSB-WB, 8 metal strip clips and an identification plate. Sufficient for approx. 2 m length.Dimension data: sections of the bandage FSB-WB
Scope of the surrounding cable support systems:FSB-K32 maximum 320 mmFSB-K82 maximum 820 mm(including min. 5 cm bandage overlap)
Always indicate the item number when ordering.
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
100
Metal strip clips
Metal strip clips, wide
Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing.
750 121000 121200 121500 12
TypeMBS 075MBS 100MBS 120MBS 150
Lengthmm
Widthmm
Weightkg/100 pc.2.3003.0003.6004.400
Item no.7203108720311072031127203114
PackPiece25252525
Metal strip clips, narrow
Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing.
150 7300 7450 7610 7
TypeMBS 015MBS 030MBS 045MBS 061
Lengthmm
Widthmm
Weightkg/100 pc.0.2300.3990.6020.806
Item no.7203100720310272031047203106
PackPiece1001005050
Tightening straps
Tightening strap for fastening of cable banda-ges
100 m roll of lightweight, galvanised tightening strap, for universal fastening.
15 100TypeFSB-SB 100
Widthmm
per rollm
Weightkg/100 pc.220.000
Item no.7203131
PackPiece1
B1
B
t1 t
Tightening strap locks
Tightening strap lock
Tightening strap lock with buckle, for simple fixing of the tightening straps FSB-SB.
26 24TypeFSB-SV
Lengthmm
Widthmm
Weightkg/100 pc.0.340
Item no.7203132
PackPiece50
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
101
Fuse clip
Securing clip
Stainless steel clip to secure the bend tightening strap. Provides prevention of removal from the lock.
14 29TypeFSB-SC
Widthmm
Heightmm
Weightkg/100 pc.0.180
Item no.7203134
PackPiece50
Pliers
Pliers for metal strip clips
High-quality spring chuck with cutting tool for metal strip clips, type MBS.
TypeMBS-Z
Weightkg/100 pc.55.500
Item no.7203120
PackPiece1
Identification plates
Identification plate
100
70
25
Ø 7
85
Universal identification plate to be written on with waterproof and light-resistant felt-tip pen for cable bandages,including two push-fit anchors.
GermanTypeKS-FSB DE
Language Weightkg/100 pc.2.400
Item no.7203140
PackPiece1
Always indicate the item number when ordering.
Cab
le b
anda
ges –
prev
entio
n of
the
spre
ad o
f fire
102
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
DirectoriesD
irect
orie
s
104
Directories
Numeric directory 112
Pictogram explanation 108
Test marks 106
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Dire
ctor
ies
105
D E S I G N
A S S E S S E D
American Bureau of Shipping, USA
AENOR, Producto Certificado, Spain
STOWARZYSZENIE ELEKTRYKÓWPOLSKICH, Poland
Lightning current-tested
Lightning current-tested, Class H (100 kA)
CEBEC, Belgium
Canadian Standards Association, Canada
DEMKO, Danmarks Elektriske Materielkontrol,Denmark
Deutsches Institut für Bautechnik Berlin,Germany
Det Norske Veritas
ENEC Austria
ATEX certificate for explosive areas
ELEKTROTECHNICKÝ ZKUŠEBNÌ ÚSTAV,Czech Republic
FIMKO, Finland
Forschungs- und Materialprüfungsanstalt,Germany
Russia, GOST The State Committee forStandards
Test marks for technical resources, VDE Prüf-und Zertifizierungsinstitut Offenbach,Germany
Halogen-free; without chlorine, fluorine andbromine
INMETRO, Brazil
KEMA-KEUR, Netherlands
MIndication of metric products
MAGYAR ELEKTROTECHNIKAI ELLENŐRZŐINTÉZET Budapest, Hungary
NEMKO, Norway
AFNOR Quality symbol of the Frenchstandardisation institute
Test marks
Underwriters Laboratories Inc., USA + CSA,Canada
Österreichischer Verband für Elektrotechnik,Austria
INSTITUTO ITALIANO DEL MARCHO DIQUALITÁ, Italy
RINA 1861, Ship Classification, Certificationand Services
Underwriters Laboratories Inc., USA
SEMKO An Inchcape Testing ServicesCompany, Sweden
Eidgenössisches Starkstrominspektorat,Switzerland
South African Bureau of Standards
Shock-tested, Bundesamt für Zivilschutz,Germany
Sähkötarkastuskeskus ElinspektionscentralenElectrical Inspectorate, Finland
Underwriters Laboratories Inc., USA
Underwriters Laboratories Inc., USA
Verband der Elektrotechnik, Elektronik,Informationstechnik e.V., Germany
German Association of Electricians, testedsafety
5-year warranty
Always indicate the item number when ordering.
Dire
ctor
ies
106
Surfaces
Strip galvanised
Strip galvanised/plastic-coated
Strip galvanised zinc/aluminium, double dip
Bright
Anodised
Hot-dip galvanised
Electrogalvanised
El Electrogalvanised/plastic-coated
Electrogalvanised, yellow-chromated
Electrogalvanised, yellow passivated
Electrogalvanised, transparently passivated
Primed
L Painted
Welding primed
Hot-dip galvanised
S OSOHot-dip galvanised 85 µm
Copper-plated
Nickel-plated
Galvanised, Deltatone 500
ZDM Galvanised, MAGNI 565
Zinc-aluminium coated, Galfan
Zinc scale
Conformity symbol
Communautés Européennes, EC declaration ofconformity according to EC directivesCommunautés Européennes, EC declaration ofconformity according to EC directives
RoHS-conformantRoHS-conformant
Quality marks
Halogen-free; without chlorine, fluorine and bromineHalogen-free; without chlorine, fluorine and bromine
Flame resistant 650 °CFlame resistant 650 °C
Flame resistant 750 °CFlame resistant 750 °C
Flame resistant 960 °CFlame resistant 960 °C
UV-resistantUV-resistant
Pictogram explanation
Specific product symbols
Diameter 60 mmDiameter 60 mm
Diameter 68 mmDiameter 68 mm
Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11
Transition from LPZ 2 to LPZ 3Transition from LPZ 2 to LPZ 3
Acoustic signallingAcoustic signalling
Applications
Remote signallingRemote signalling
Acoustic signallingAcoustic signalling
Integrated Service Digital Network, ISDN applicationsIntegrated Service Digital Network, ISDN applications
Digital Subscriber Line, DSL applicationsDigital Subscriber Line, DSL applications
Analogue telecommunicationAnalogue telecommunication
Category 5 TwisterPairCategory 5 TwisterPair
Channel Performance to American EIA/TIA standardChannel Performance to American EIA/TIA standard
Measuring, controlling and regulating systemsMeasuring, controlling and regulating systems
TV applicationsTV applications
SAT-TV applicationsSAT-TV applications
MultiBase baseMultiBase base
LifeControlLifeControl
Intrinsically safe protection device for potentiallyexplosive areasIntrinsically safe protection device for potentiallyexplosive areas
Channel Performance to ISO / IEC 11801Channel Performance to ISO / IEC 11801
Power over EthernetPower over Ethernet
230/400 V system230/400 V system
Protection rating IP 54Protection rating IP 54
Protection rating IP 65Protection rating IP 65
Lightning protection classes
Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11
Combination protection device made of type 1and type 2Combination protection device made of type 1and type 2
Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11
Always indicate the item number when ordering.
Dire
ctor
ies
108
Lightning protection classes
Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11
Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11
Lightning protection zone
Transition from LPZ 0 to LPZ 1Transition from LPZ 0 to LPZ 1
Transition from LPZ 0 to LPZ 2Transition from LPZ 0 to LPZ 2
Transition from LPZ 0 to LPZ 3Transition from LPZ 0 to LPZ 3
Transition from LPZ 1 to LPZ 2Transition from LPZ 1 to LPZ 2
Transition from LPZ 1 to LPZ 3Transition from LPZ 1 to LPZ 3
Transition from LPZ 2 to LPZ 3Transition from LPZ 2 to LPZ 3
BSS maintenance of electrical function installation
Fire-tested systemsFire-tested systems
Escape route ceiling mounting with pressure clipEscape route ceiling mounting with pressure clip
OBO Grip, wall routing typeOBO Grip, wall routing type
OBO Grip, ceiling routing typeOBO Grip, ceiling routing type
Pressure clip for maintenance of electrical function,ceiling mountingPressure clip for maintenance of electrical function,ceiling mounting
BSS anchor
Fire protection anchorFire protection anchor
Fire protection bolt tieFire protection bolt tie
BSS test marks/material class
Maintenance of electrical function class E30Maintenance of electrical function class E30
Maintenance of electrical function class E90Maintenance of electrical function class E90
Clamp clip base shapes
Clamp clip for C profile rail, slot width 11–12 mmClamp clip for C profile rail, slot width 11–12 mm
Clamp clip for C profile rail, slot width 16–17 mmClamp clip for C profile rail, slot width 16–17 mm
Clamp clip for C profile rail, slot width 18–22 mmClamp clip for C profile rail, slot width 18–22 mm
Diameter
Diameter 60 mmDiameter 60 mm
Diameter 68 mmDiameter 68 mm
Diameter 70 mmDiameter 70 mm
Diameter 74 mmDiameter 74 mm
Entries
4 cable entries4 cable entries
6 cable entries6 cable entries
7 cable entries7 cable entries
8 cable entries8 cable entries
9 cable entries9 cable entries
10 cable entries10 cable entries
12 cable entries12 cable entries
10 cable entries ECO10 cable entries ECO
12 cable entries ECO12 cable entries ECO
14 cable entries ECO14 cable entries ECO
16 cable entries16 cable entries
18 cable entries ECO18 cable entries ECO
24 cable entries24 cable entries
Gland thread
Thread metricThread metric
Thread PgThread Pg
Entry size
M20 entryM20 entry
M25 entryM25 entry
M32 entryM32 entry
M40 entryM40 entry
KTS side heights
Cable tray, side height 35 mmCable tray, side height 35 mm
Cable tray, side height 60 mmCable tray, side height 60 mm
Cable tray, side height 85 mmCable tray, side height 85 mm
Mesh cable tray, slant height 35 mmMesh cable tray, slant height 35 mm
Mesh cable tray, slant height 55 mmMesh cable tray, slant height 55 mm
Materials
Flat steelFlat steel
Angular steelAngular steel
U steelU steel
Round materialRound material
Pictogram explanation
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Dire
ctor
ies
109
Nominal cross-section
Nominal cross-section 1.5 mm²Nominal cross-section 1.5 mm²
Nominal cross-section 1.5–2.5 mm²Nominal cross-section 1.5–2.5 mm²
Nominal cross-section 2.5 mm²Nominal cross-section 2.5 mm²
Nominal cross-section 2.5–4 mm²Nominal cross-section 2.5–4 mm²
Nominal cross-section 4 mm²Nominal cross-section 4 mm²
Nominal cross-section 4–6 mm²Nominal cross-section 4–6 mm²
Nominal cross-section 6 mm²Nominal cross-section 6 mm²
Nominal cross-section 10 mm²Nominal cross-section 10 mm²
Nominal cross-section 16 mm²Nominal cross-section 16 mm²
Nominal voltage
Nominal voltage 400 VNominal voltage 400 V
Nominal voltage 500 VNominal voltage 500 V
Nominal voltage 660 VNominal voltage 660 V
Polarity
3-pole3-pole
5-pole5-pole
7-pole7-pole
8-pole8-pole
10-pole10-pole
12-pole12-pole
Slot widths
Slot width 7.5 mmSlot width 7.5 mm
Slot width 11 mmSlot width 11 mm
Slot width 11–12 mmSlot width 11–12 mm
Slot width 12 mmSlot width 12 mm
Slot width 15 mmSlot width 15 mm
Slot width 16 mmSlot width 16 mm
Slot width 16.5 mmSlot width 16.5 mm
Slot width 16–17 mmSlot width 16–17 mm
Slot width 17 mmSlot width 17 mm
Slot width 18 mmSlot width 18 mm
Slot width 22 mmSlot width 22 mm
Slot width 35 mmSlot width 35 mm
Pictogram explanation
Screw heads
Philips screwPhilips screw
Torx screwTorx screw
Phillips screwPhillips screw
PozidrivePozidrive
Firing devices
Bolt-firing toolBolt-firing tool
Nail deviceNail device
Protection rating
Protection rating IP 20Protection rating IP 20
Protection rating IP 30Protection rating IP 30
Protection rating IP 31Protection rating IP 31
Protection rating IP 44Protection rating IP 44
Protection rating IP 54Protection rating IP 54
Protection rating IP 55Protection rating IP 55
Protection rating IP 65Protection rating IP 65
Protection rating IP 66Protection rating IP 66
Protection rating IP 67Protection rating IP 67
Protection rating IP 68Protection rating IP 68
Metals
Aluminium
Aluminium/steel
Stainless steel, rustproof
Stainless steel, rustproof
Stainless steel, rustproof
Copper
Brass
Steel
Malleable iron
Die-cast zinc
Plastics
Acrylonitrile butadiene styrene
Duroplast, Aminoplast, type 131.5
Duroplast, melamine resin, type 150
Ethylene vinyl acetate
Always indicate the item number when ordering.
Dire
ctor
ies
110
Plastics
Fibre-proof material DIN 28091
Fibre-glass-reinforced plastic
Rubber mixture
Nitrile rubber
Petrolatum
Polyamide
Polyamide, fibre-glass reinforced
Polybutylene terephthalate
Polycarbonate
Polyethylene
Polypropylene
Polypropylene, fibre-glass reinforced
Polystyrene
Polyvinylchloride
Cellular polyethylene
Schu
tzin
stal
latio
n Ab
scho
ttung
en u
nd K
abel
band
agen
/ en
/ 20
21/0
6/22
09:
35:2
9 09
:35:
29 (L
LExp
ort_
0292
8) /
2021
/06/
22 0
9:35
:54
Always indicate the item number when ordering.
Dire
ctor
ies
111
Numeric directory
/100 pc.
3141047 1752532113141128 175253334
3400069 1852980903400085 185298151
3402207 1853003113402215 185300373
3498108 1865596573498261 1865596643498262 186842568/100 pc.
3498320 7864118183498396 786411948
/pc.7202200 1758565597202201 1758565667202203 1758565977202204 1758566037202205 1758566107202206 1758566277202207 1758566657202208 1758566727202209 1758566897202210 1758567197202212 7660869177202213 7760869247202214 7660536747202215 7760869317202216 7760869487202217 7760869797202218 7760869867202219 7760869937202220 7760870067202283 1958478547202295 2658501207202300 1658501377202302 1758501447202305 1964471387202306 1959189297202308 1864231257202309 1964471527202310 2658501827202312 2658501997202322 6654281907202436 2068395207202446 206839551
/pc.7202505 4264344597202510 4254282757202515 6464344667202521 4358479157202553 6564345037202557 6564345107202561 6564345277202565 6564345657202569 6564345727202573 6564345897202577 6564346267202581 6564346337202613 6554283367202617 6554283437202624 6561428117202628 6561429347202660 6561440137202709 3464609917202725 3464608787202741 3464607557202904 1958478617202912 1958478787202963 3458478857202971 345847892
/100 pc.7203100 10156933457203102 10156933527203104 8556933697203106 10156933767203108 10156933837203110 10156933907203112 1015693406
Item no. PageGTIN /100 pc.
7203114 1015693413/pc.
7203120 10256934207203131 1015993056/100 pc.
7203132 10156934447203134 1025726425
/pc.7203140 10258116717203150 10059218517203154 10059218687203160 10057064347203163 1966087377203170 10064755137203800 405817499price/pac7203803 415817505
/pc.7203806 4158175367203809 4158175437203813 4166428927203816 416820900
/pc.7203818 4264363547203900 4066195047203903 6466195117203906 6666195287203909 6566195357203912 6566195427203915 6566195597203919 6566195667203921 6566195737203924 206619580
7204290 8468101617204292 8468101787204296 846810185
/pc.7204300 2061357527204304 2061357697204306 846448081
7205425 2054482597205426 2064619747205427 2057038087205429 2057256957205438 206446872
7206058 1658500837206104 165850076
Item no. PageGTIN
Always indicate the item number when ordering.
Dire
ctor
ies
112
OBO Bettermann Holding GmbH Co. KGP.O. Box 112058694 Menden, Germany
Customer ServiceTel.:+49 23 73 89 - 17 00Fax: +49 23 73 89 - 12 [email protected]
www.obo-bettermann.com
Building Connections
© O
BO
BETT
ER
MA
NN
Ord
er n
o. 9
196339 0
6/2
021 E
N