  • Introduction, Table of Contents

    System Overview 1Procedure - From Planning toInitial Operation 2

    IM 308-C and Memory Card 3S5-95U with DP Master Interface:Design and Method of Operation 4Routing Cables and BusConnectors 5

    RS 485 Repeaters 6

    Starting COM PROFIBUS 7Parameterizing, Saving andStarting the Configuration withCOM PROFIBUS

    8

    IM 308-C Addressing, Accessto the Distributed I/Os andDiagnostics

    9

    IM 308-C Using the FB IM308C 10S5-95U Addressing,Diagnostics, FB 230 11

    IM 308-C Starting ET 200 12

    S5-95U Starting ET 200 13Upgrading to COM PROFIBUSor to IM 308-C 14

    AppendicesA to

    G

    Glossary, Index

    28061610002

    ET 200 Distributed I/O System

    Manual

    SIMATIC S5/505

    http://www.efesotomasyon.com/html/siemens/siemens.html

  • iiET 200 Distributed I/O System

    2806161 0002

    This manual contains notices which you should observe to ensure your own personal safety, aswell as to protect the product and connected equipment. These notices are highlighted in themanual by a warning triangle and are marked as follows according to the level of danger:

    !Danger

    indicates that death, severe personal injury or substantial property damage will result if properprecautions are not taken.

    !Warning

    indicates that death, severe personal injury or substantial property damage can result if properprecautions are not taken.

    !Caution

    indicates that minor personal injury or property damage can result if proper precautions are not taken.

    Note

    draws your attention to particularly important information on the product, handling the product, orto a particular part of the documentation.

    The device/system may only be set up and operated in conjunction with this manual.

    Only qualified personnel should be allowed to install and work on this equipment. Qualifiedpersons are defined as persons who are authorized to commission, to ground, and to tag circuits,equipment, and systems in accordance with established safety practices and standards.

    Note the following:

    !Warning

    This device and its components may only be used for the applications described in the catalog or thetechnical description, and only in connection with devices or components from other manufacturerswhich have been approved or recommended by Siemens.

    This product can only function correctly and safely if it is transported, stored, set up, and installedcorrectly, and operated and maintained as recommended.

    SIMATIC and SINEC are registered trademarks of SIEMENS AG.

    Some of the other designations used in these documents are also registered trademarks; the own-ers rights may be violated if they are used be third parties for their own purposes.

    We have checked the contents of this manual for agreement with thehardware and software described. Since deviations cannot be pre-cluded entirely, we cannot guarantee full agreement. However, thedata in this manual are reviewed regularly and any necessary cor-rections included in subsequent editions. Suggestions for improve-ment are welcomed.

    Technical data subject to change. Siemens AG 1995

    Disclaimer of LiabilityCopyright Siemens AG 1995 All rights reserved

    The reproduction, transmission or use of this document or itscontents is not permitted without express written authority.Offenders will be liable for damages. All rights, including rightscreated by patent grant or registration of a utility model or design, arereserved.

    Siemens AGAutomation GroupIndustrial Automation SystemsP.O. Box 4848, D-90327 Nuremberg

    Siemens Aktiengesellschaft Order No. PPX;50582062

    Safety Guidelines

    Qualified Personnel

    Correct Usage

    Trademarks

  • iiiET 200 Distributed I/O System28061610002

    Introduction

    The information in this manual will enable you to:

    set up the PROFIBUS bus

    parameterize the configuration of the ET 200 distributed I/O system withthe COM ET 200 Windows software

    operate the IM 308-C as DP master and/or DP slave

    parameterize the standard function block FB IM308C for the IM 308-C

    operate the S5-95U with DP master interface on the PROFIBUS-DP

    parameterize and operate the configuration of a DP system and/or an FMSsystem with SIMATIC NET PC modules, e.g. the CP 5412 (A2) commu-nications processor, as master

    start up the PROFIBUS, and

    using COM PROFIBUS, interpret the status of the inputs/outputs anddiagnostics messages while the PROFIBUS is operating

    This manual deals with the S5-95U programmable controller andsupplements the system manual S5-90U/S5-95U Programmable Controller. Itdescribes all the functions and features of the DP master interface of theS5-95U.

    Purpose of themanual

  • ivET 200 Distributed I/O System

    28061610002

    This manual is applicable to:

    Module / software Order number As of release/version

    IM 308-C 6ES5 308-3UC11 6

    S5-95U 6ES5 095-8ME01 3

    CP 5412 (A2) 6GK1 541-2BA00 1

    SOFTNET for PROFIBUS See Catalog IK 10

    COM PROFIBUS 6ES5 895-6SE.2 3

    RS 485 repeater 6ES7 972-0AA00-0XA0 1

    PROFIBUS bus connectors 6ES7 972-0B.10-0XA06ES7 972-0B.20-0XA06ES7 972-0BA30-0XA0

    111

    FB IM308C (FB 192) withdemo program

    Shipped together withCOM PROFIBUS

    3

    This manual describes all the modules approved at the time of issue. We re-serve the right to enclose a Product Information Sheet containing up-to-dateinformation with each new or revised module.

    This manual is intended for users wishing to plan, set up or operate theET 200 distributed I/O system with COM PROFIBUS. Readers should havepractical experience of or be familiar with the use of the S5-95U, S5-115U,S5-135U or S5-155U programmable controllers or the SIMATIC NET PCmodules, depending on the master which is to be used.

    If you parameterize PROFIBUS-FMS with COM PROFIBUS, you must al-ready be familiar with PROFIBUS-FMS.

    Applicability of themanual

    Target group

    Introduction

  • vET 200 Distributed I/O System28061610002

    What has changed since the predecessor version of this manual:

    Using COM PROFIBUS V 3.0 you can parameterize:

    other masters, such as SIMATIC NET PC modules (e.g. CP 5412 (A2),CP 5411, CP 5511, CP 5611) for PROFIBUS-DP and/orPROFIBUS-FMS

    other DP masters (with the aid of the type file for DP masters)

    other slaves, such as ET 200X or slaves belonging to the low-voltageswitchgear, control and monitoring, valve, controller, MOBY identifi-cation system and encoder families, etc.

    Service functions of COM PROFIBUS, such as overview and slave diag-nostics, status of the slave inputs and outputs while the PROFIBUS is op-erating, allocating and changing a PROFIBUS address

    A master system can be exported to/from the IM 308-C directly via thePROFIBUS, i.e. the memory card no longer needs to be read/written di-rectly on the PC

    Extended description of the bus connectors

    Enhanced functions of the standard function block FB IM308C

    The components described in this manual comply with the requirements ofthe CE mark of conformity. CSA, UL and FM certifications have been ob-tained.

    Please refer to section A.1 for further details of certifications and standards.

    The master interface IM 308-C, the DP master interface of the S5-95U andthe SIMATIC NET PC modules are based on EN 50 170, Volume 2,PROFIBUS.

    You will find information on the S5-95U with DP-master interface and allother versions of the S5-95U in the system manual S5-90U/S5-95U Program-mable Controller. At various points in this manual, you will find referencesto the system manual S5-90U/S5-95U Programmable Controller.

    Separate installation instructions are available for the SIMATIC NET PCmodules and enclosed with them.

    The description of the slaves does not form part of this manual. You can findthe order numbers for the slave manuals in Catalog ST PI, PROFIBUS &AS-Interface, Components on the Field Bus.

    How this manualdiffers from thepredecessors

    Standards andcertifications

    Other requisitemanuals

    Introduction

  • viET 200 Distributed I/O System

    28061610002

    A number of features in this manual will help you to obtain quick access tothe information you require:

    At the start of the manual, you will find a general table of contents, plus alist of all the illustrations and a list of all the tables in the manual.

    On each page throughout the manual, the bold-face headings on the leftsummarize the contents of the individual passages.

    The Appendices are followed by a Glossary containing definitions of theimportant terms used in the manual.

    The manual closes with an index. The index is in alphabetical order andyou can use it to find information on the topic of your choice.

    The KO-ET 200 workshop is an ideal introductory course for users wantingto familiarize themselves with the ET 200 distributed I/O system.

    If you would like more information, contact your regional Training Center orus at the following address:

    Product Marketing for SIMATIC, SIMATIC NET and COROSAUT 951Postfach 4848D-90327 Nrnberg

    Tel: +49 911 895-3154Fax: +49 911 895-5021

    If you have any questions on the ET 200 distributed I/O system, contact:

    Hotline SIMATIC, SIMATIC NET, COROS,Nrnberg-MoorenbrunnTel.: +49 911 895-7000Fax: +49 911 895-7001/-7002

    If you have any questions or suggestions relating to this manual, please com-plete the suggestions sheet and return it to us. You will find the suggestionssheet inside the rear cover of the manual.

    Quick access

    Training courses

    Queries

    Introduction

  • viiET 200 Distributed I/O System2806161000

Recommended

View more >