9/30/2020 VER 1.0 S-16 Introduction
S-16 Route Setting type Relay Interlocking
SURESH HELCHEL Instructor (Signal),IRISET/SC
![Page 2: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/2.jpg)
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 2
Siemens PI
Siemens RRI
Usually preferred for smaller yards. Used for major yards or busy sections.
Points in the route, overlap and isolation are operated individually prior to Signal clearance.
Points in the route overlap and isolation are operated automatically with the setting of route.
Minor Point group is used. Major Point group is used.
NWKR/RWKR are normally pickup. NWKR/RWKR are normally dropped, pick-up only when Sub Route and Overlap are set.
Difference between P.I & RRI
![Page 3: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/3.jpg)
3
Siemens PI
Siemens RRI
Before setting any point individually,
it shall be ensured that all relevant
U(R)S and OVZ2U(R)R are normal.
Point setting is done by concerned U(R)S,
OVZ2U(R)R. Locking provided at various
stages takes care of the same
Points in the route, overlap and isolation are operated individually before signal operation.
Setting of points in route, overlap, isolation and also clearing the signal is achieved by single operation of pressing the GN & UN buttons together.
Point chain group not used. Point chain group is used for auto operation of
point.
Difference between P.I & RRI
![Page 4: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/4.jpg)
4
Siemens PI
Siemens RRI
After individual setting of points,
locking of points for the route is
achieved through U(R)S and
OVZ2U(R)R
U(R)S and OVZ2U(R)R are meant for
operation of points; W(R)LR locks the point.
NWKR/RWKR required for AU(R)S
& BU(R)S Route section setting. Route Section A U(R)S and B U(R)S are used for operation of point, NWKR and RWKR proved in DUCR of Sub Route.
Difference between P.I & RRI
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 5: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/5.jpg)
5
Point Major Group
Z1WR1 Z1NWR Z1RWR Z1WR WLR WKR1
W(R)R
W(N)R
(R)WLR1
(N)WLR1
(R)WLR2
(N)WLR2
(R)WLR3
(N)WLR3
W(R)LR
W(N)LR
WKR2
WR WJR Z2WR1 Z2WR2
TP1R TP2R WKR3
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 6: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/6.jpg)
6
Point Major Group
Relay Purpose
Z1WR Point Group control Initiation Relay with Route setting.
Z1WR1 Point Group Control Initiation relay.
WLR Checks track locking and helps in sequential operation of point.
Z1RWR Normal to Reverse Control
Z1NWR Reverse to Normal Control
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 7: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/7.jpg)
7
Relay Purpose
W(R/N)R
Used for point operation and detection mode circuit.
WR Point Contactor Relay (Heavy duty contact)
WJR Point Timer(10 Seconds)
WKR3 Checks the complete operation of point.
WKR2 Point Out of Correspondence Checking Relay.
Point Major Group
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 8: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/8.jpg)
8
Relay Purpose
WKR1
Point Detection Relay
(R/N)WLR 1,2,3 Closes point operation circuit (locks point for operation)
Z2WR1 Panel indication control relay for Pt. track on running portion of line (Pt. track in route or OV set to main line)
Z2WR2 Panel indication control relay for Pt. track on OV set to sand hump
W(R/N)LR Point group locking relay
Point Major Group
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 9: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/9.jpg)
9
Control Table S 1 to ML
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
1 S1 to ML 1GN ML
UN
4A,
1/9
4B OV10/2 OV2 5B OV3/2 4N 5N -
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
1T,9T,
10/11T,
4AT,
MLT
5AT,
2/3T
CH in S-2
RG,HG,DG
- A1T 1T 1T, 9T,
10/11T, 4AT
LC Closed
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 10: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/10.jpg)
10
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
2 CO1 to
ML
1GN,
COG
GN
ML
UN
4A,
1/9
4B OV10/2 OV2 5B OV3/2 4N 5N -
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
- - CH in - - A1T - 1T, 9T,
10/11T, 4AT
120 sec. after 1AT
occupied;
LC Closed
Control Table S 1 C-ON to ML
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 11: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/11.jpg)
11
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
3 S1 to LL
With
OV3/1
1GN LL
UN
4B,
1/9
4A OV11,
OV10/1
OV3/1 6A,
5B
OV3/2 4R 5N 6N
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
1T,9T,
10/11T,
4AT,
4BT,
LLT
5BT
CH in S-3
RG
Left A1T 1T 1T, 9T,
10/11T, 4AT,
4BT
LC Closed
Control Table S 1 C-ON to LL
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 12: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/12.jpg)
12
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
4 Co1 to
LL
With
OV3/1
1GN,
COG
GN
LL
UN
4B,
1/9
4A OV11,
OV10/1
OV3/1 6A,
5B
OV3/2 4R 5N 6N
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
- - CH in - - A1T - 1T, 9T,
10/11T, 4AT,
4BT
120 sec. after 1AT
occupied;
LC Closed
Control Table S 1 C-ON to LL
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 13: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/13.jpg)
13
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
5 S1 to LL
With
OV3/2
1GN LL
UN
4B,
1/9
4A OV11,
OV10/1
OV3/2 6A,
5A
OV3/1
,
OV2
4R 5R 6N
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
1T,9T,
10/11T,
4AT,
4BT,
LLT
5BT,5
AT,2/
3T
CH in S-3
RG,HG
Left A1T 1T 1T, 9T,
10/11T, 4AT,
4BT
LC Closed
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Control Table S 1 C-ON to LL
![Page 14: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/14.jpg)
14
S.
No.
Sig.
Route
Push
Buttons
In the route In the OV Points set
GN UN RS
Set
Eliminated OV
Set
Eliminated RT OV Iso
RS OV RS OV
6 Co11 to
LL
With
OV3/2
1GN,
COG
GN
LL
UN
4B,
1/9
4A OV11,
OV10/1
OV3/2 6A,
5A
OV3/1
,
OV2
4R 5R 6N
TC Clear Y/
LC/
CH
Signal
ahead
proved
RI
App.
Lock
TC
Sig.
ON
TC
Back lock
TC
Remarks
RT OV
- - CH in - - A1T - 1T, 9T,
10/11T, 4AT,
4BT
120 sec. after 1AT
occupied;
LC Closed
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Control Table S 1 C-ON to LL
![Page 15: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/15.jpg)
15
Signal Clearance Route initiation to signal clearance
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 16: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/16.jpg)
16
Signal Clearance Route initiation to signal clearance
GNR Signal Button Relay
UNR Route Button Relay
Sh G(R/N)R Shunt Signal /Main Signal selection relay.
ZU(R/N)R Direction determining relay
Z1UR Sub Route Initiating Relay
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 17: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/17.jpg)
17
Z1UR1 Diversion Selection relay, Normally drop for main line movement and picks up for diversion movement.
Sh GZR Shunt Signal Route Initiating Relay.
Mn GZR Main Signal Route Initiating Relay.
ZDUCR Zonal Route permissibility Checking Relay, depends upon number of zones.
Signal Clearance Route initiation to signal clearance
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 18: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/18.jpg)
18
Z1UR1: Diversion Selection Relay
In case of RRI, NWKR and RWKR relays are normally drop. Hence to know the movement is initiated for Main line or For a diversion line Z1UR1 relay is used. o Z1UR1 is a Normally drop Relay.
o Front contact of this relay is for diversion line. o Back contact of this relay is used for straight line.
o Z1UR1 is named after the point number.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 19: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/19.jpg)
19
S1
S10
S11 S12
S3
S2
4
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Z1UR1: Diversion Selection Relay
GNPR Loop Line
UNR
Loop Line
GNPR UNR
Z1UR1
OR
217
Mn Line
Loop Line
5
![Page 20: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/20.jpg)
20
Mn GZR and Sh GZR
Purpose: o Differentiate the path for initiation circuit of main and shunt signal. o Main signal and Shunt signal is initiated in two different path to
pick up ZDUCR relay
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Mn Signal Initiation (Selection) Relay. Sh Signal Initiation (Selection )Relay.
![Page 21: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/21.jpg)
Sh
GNPR
Mn
GNPR
UNCR
GNCR
Mn
GZR
Sh
GZR
Mn
GZR
Sh
GZR
Sh
GZR ZDUCR
CO
GGNR
Mn
GZR Mn
GZR
Sh
GZR
1 2 3 4 5
Mn GZR: Main Signal Initiation Relay.
Sh GZR : Shunt Signal Initiation relay.
In the Route In the Overlap
1 Main Signal Initiation
2.Shunt Signal Initiation
3.Mn GZR
4.Sh GZR.
5.C-ON
S 15 Panel Interlocking (Siemens) IRISET Ver 1.0
![Page 22: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/22.jpg)
ZDUCR
Zonal Route Permissibility Check
S1
S5
Mn
GNPR
UNCR
GNCR
1 2
Z1UR1
Z1UR1
4B
U(R)PS
4A
U(R)PS
ZU(N)R
ZU(N)R
ML
UNR LL
UNR
4
Z1UR
S1
GNR
4
1.Main Signal Initiation Path
2.Shunt Signal Initiation Path Sh
GNPR
4
Z1UR
ML
LL
ZU(N)R
ZU(R)R
![Page 23: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/23.jpg)
23
o First relay to pick up in Signal Clearances. Checks the
permissibility for route initiation, it checks ……
o SH G(R/N)R Conflicting Signal.
o ZU(R/N)R Conflicting Movement.
o ZDUCPR After operation are dropped.
o EUYR & EUUYR DROPS no cancellation is in progress.
Checks that relays involved in stage ii is dropped
Conditions:
Signal button and Route button to be kept in pressed condition.
ZDUCR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 24: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/24.jpg)
GZR & ZDUCR CIRCUIT
EUUYNCR
ZDUCPR
MN
GZR
SH
GZR COGGNR
ZDUCR
ZDUCR
2
MN GZR
3
SH GZR
SH GNPR
EUYR
EUUYR
4
SH GZR
MN GNPR
MN GZR
COGGNR
SH GZR
EUUYNR
EUYNR
EUUYNR
OUT IN
Between OUT and IN checks GN & UN button are pressed and the overlap s are not set
OV
![Page 25: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/25.jpg)
Sequence : Route Permissibility to Sub-route lock
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
ZDUCR
U(R)PS U(R)PS RS With Point RS Without Point
OVZ2U(R)R
U(R)S
Point Group Control
Initiates,Z1WR
If point is not in
required position
Point Group Control
Initiates,Z1WR
If point is not in
required position
NWKR/RWKR
DUCR
U(R)LR
TPR
UDKR
U(R)S
NWKR/RWKR
GLSR
GN & UN Buttons are Released
![Page 26: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/26.jpg)
26
U(R)S and U(R)PS
Conditions to pick up U(R)S: oRoute is initiated i.e. Z1UR & ZDUCR are up. o Sub route is unlocked i.e. U(N)LR is up. o Conflicting Overlap is normal. o Conflicting Route section is normal.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 27: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/27.jpg)
27
4 Z1UR
ZDUCR
4 B Z1UR1
OV 10/2 Z2U(R)R
4 A U(R)S 4 A U(R)PS
4 A U(N)PS
Sub Route initiation Relay
Checks Route is initiated.
Diversion selection Relay.
Conflicting Overlap is Normal.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 28: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/28.jpg)
28
Point Group Control Initiation Z1WR
U(R)S OVZ2U(R)R
Z1WR
WLR
WWR
TPR ZDUCR Z1UR
Point Operation with Route Setting o U(R)S or OVZ2U(R) is pickup. o Z1WR Pikes up . o WLR Checks Route Initiation o WLR Checks Track Locking.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 29: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/29.jpg)
29
Z1WR (Major Group only) o First relay to pick up in the point group under route initiation to operate the point in the route, overlap and in isolation. CONDITION o Route sections are set U(R)S o Overlap are set OVZ2U(R)R o Point is detected….. WKR1 Purpose: o To by pass the individual point operation button contact for auto operation of point.
Point Group Control Initiation Z1WR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 30: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/30.jpg)
30
Point Group Control Initiation Z1WR
S1
S10
S11 S12
S3
S2
4
W(N)R
WR
WKR1
4 A
U(R)S 4 B
U(R)S OV-10
Z2U(R)R
OV-10/2
Z2U(R)R OV-11
Z2U(R)R
1 Z1WR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 31: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/31.jpg)
31
Point Group Control Initiation WLR
WLR (Double Coil Relay) Point Locking Relay o It checks the conditions for Z1WR Point Group is initiated due to route setting Z1UR & ZDUCR is UP. o Point track locking condition (TP1P2R) o Helps in sequential operation of points (Z3WR)
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 32: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/32.jpg)
32 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Point Group Control Initiation WLR
![Page 33: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/33.jpg)
33 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Point Chain Group Initating Relay Z3WR
Z3WR: Point Chain group Initiating Relay. o Normally dropped Relay. o Slow to release for smooth chain operation. Conditions: I. Z1WR up II. WLR up.
![Page 34: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/34.jpg)
34
Point Chain Group Initiating Relay Z3WR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 35: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/35.jpg)
35 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Point Chain Group Relay WWR
WWR:Point Chain Group Relay I. Consist of 8 Neutral Relay. II. 8 Major groups can be arranged in one Rack. III. Each WWR correspond to one Major Group.
![Page 36: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/36.jpg)
36 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Point Group Control Initiation Z1WR1
![Page 37: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/37.jpg)
37 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Signal Clearance
![Page 38: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/38.jpg)
38 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Signal Lock Stick Relay GLSR
o This relay creates the condition for Signal Clearance. o Drops before signal clearance, to ensure One train One
Signal. o Slow to release to pickup G(R)LR.
![Page 39: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/39.jpg)
39
GR2
GLSR GLSR GLSR
G(R)LR GR1
1 2 3
Purpose of GLSR: 1. Creates condition for signal clearance GR1
up. 2. Slow to release to pickup G(R)LR. 3.GLSR drop use in signal clearance i.e.GR2. 4.After picking up of G(R)LR ,GLSR drops.
Signal Lock Stick Relay GLSR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 40: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/40.jpg)
40
Conditions required to pickup GLSR: I. Route is initiated
o GZR o ZDUCR.
2. GN & UN buttons are in pressed condition. 3. Concerned Route Sections & Overlaps are set. 4. Holds through first Route Section.
Signal Lock Stick Relay GLSR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 41: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/41.jpg)
11.8
S-2
GNR
EGNR
S-2
GLSR
GLSR
GPR1
GLSR
COULR2
S 2
U(R)S
S
OV1-4
Z2U(R)R
Mn
GZR
ZDUCR
OV-3
Z2U(R)R
OV2-4
Z2U(R)R
DM
UNPR
102 A
U(R)S
DL
UNPR
102 B
U(R)S
101 A
U(R)S
S-2
U(R)PS
Signal Lock Stick Relay GLSR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 42: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/42.jpg)
42 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Signal Controlling Relay
GR1
Signal Controlling Relay No 1 o Made slow to release to prevents signal going
to danger, in case of track circuit flickering.
Conditions to pickup : o GLSR is pickup. o Signal Buttons are released. o Signal in advance is not blank. o OV is set and point is detected. o Track Circuits are free. o Points in the Route is checked by DUCR.
![Page 43: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/43.jpg)
S 20
S 18
S 19
OV- 18
OV- 19, OV2-18
UL
UP Main S 20 U(R)S 113 A
113 B
S 19
HECR
S 19
RECR
S 19
HECR
OV Tracks
OVZ2U(R)R
OV Point
N/RWKR
Berthing Track
113 A DUCR
113 U(R)LR
Track Circuits
in the run
S 20
UDKR
11.9
S-20
GNR
GLSR
GR1
EGNR
100 Ohms
5 Watt
500 Mfd
27
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
GR1
![Page 44: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/44.jpg)
44 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Signal locking Relay G(R)LR
Circuit Source of supply
GLSR Separate fuse.
GR1 Signal in advance
G(R)LR Same Group Supply
o Picks up through slow to release timing of GLSR(500-700 mile seconds
G(R)LR: o Provided for every main signal. o Locks the action done by the GLSR.
![Page 45: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/45.jpg)
45
Signal locking Relay G(R)LR
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 46: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/46.jpg)
46 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Point Major Group
![Page 47: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/47.jpg)
Super Imposed Operation and Detection. o Series mode of Operation. Criteria: o Left hand and Right hand cross over. o Right Hand Machine1 operates then Machine 2. o Left Hand Machine2 operates then Machine 1. Length of Operation: o 400Volts ACI up to 1.2 KM. o More Than 1.2 KM Point Switching Group is used. Groups Used: o RRI Installation Major RRI Group. o Chain Group for Route Setting type only.
Point Operation
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 48: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/48.jpg)
Position Of Point
Left Hand Cross Over
Right Hand Cross Over
NORMAL 1-1 A & 4-4A 2-2A & 3-3A
REVERSE 2-2A & 3-3A
1-1 A & 4-4A
Relays Normally pickup in the group:
Point at Normal W(N)R,WKR1,(N)WLR1,2,3,W(N)LR
Point at Reverse W(N)R,WKR1,(R)WLR1,2,3,W(N)LR
1-1a NC,3-3a ND,2-2a RC,4-4a RD
Field and group details
![Page 49: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/49.jpg)
Points Control Initiation, Operation, Locking & Detection Sequence
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 50: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/50.jpg)
Point Control Initiation Sequence
TPR WWNR WNR EWNR
U(R)S OVZ2U(R)R
Z1WR1(1)
WKR3
WKR1
Z1WR
WJR
WKR1
Z1WR
W(R)R W(R)R
TPR
‘R’ Operation intended ‘N’ Operation intended
Z1RWR WKR3 Z1WR1(1) Z1WR1(2) Z1NWR Z1WR1(1) Z1WR1(2)
Control initiated Control initiated
Z1WR TPR
WLR
WWR
ZDUCR Z1UR
W(N)R
![Page 51: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/51.jpg)
Point Operation Sequence
(R )WLR3
Z1RWR Z1NWR
WR
Z1WR1 Motor.
WJR
‘R’ Operation ‘N’ Operation
(R )WLR2
(R )WLR1
Z1RWR
WKR2 WKR2
WLR
Z1NWR
(N )WLR3
(N )WLR2
(N )WLR1
WJR WJR
Drops after 10 sec Drops after 10 sec
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 52: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/52.jpg)
Point Lock & Detection Sequence WR
Z1WR1
WKR3
WJR WKR2
WR
W(N)R
WKR3
WKR1
WKR3
WKR3(1)
W(R)LR
NWKR or RWKR Z2WR1 or Z2WR2
Motor
![Page 53: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/53.jpg)
53 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Z1WR1
Point Group Control Initiation
Z1WR1: First Relay to pick up, in major point group to initiate controls for point group during individual point operation. Z1WR1 picks up through Z1WR
pick up during route setting Z1WR1 1
WNR
EWNR
TP1P2R
WWNR
Z1WR
WLR
WWR
W(N)R
2 Z1WR1
W(R)R
Z1WR1
(N TO R )
TP1P2R
![Page 54: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/54.jpg)
54 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
WKR3 (N TO R ) Point Controlling Relay No 3
Normal to Reverse Operation:
WKR3 picks up twice
o With 60 Volts DC for breaking detection.
o With 110 Volts DC after complete operation.
(N)WLR3
W(N)R
Z1WR1
1 WKR3
W(N)R
B End
ND
A End
ND
N 110/60
B110 B 60
![Page 55: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/55.jpg)
55 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
WKR1 (N TO R ) Point Controlling Relay No 1
W(N)R
WKR2
WKR3
WJR ND
ND
WKR1
o Field controlling relay. o Detect the correct setting of point. o Coil of WKR2 ensures correspondence of
point. o WKR3 contact is proved to break detection for
Normal to Reverse operation. o WJR contact is proved to break detection for
Reverse to Normal operation.
B 60 N 60
![Page 56: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/56.jpg)
56 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
W(R)R (N TO R )
WNR
EWNR
TP1P2R
WWNR
W(N)R
WKR1
Z1WR1
Z1WR1 1 2
Z1WR1
W(R)R
Z1WR1
W(R)R
TP1P2R
Z1WR
WLR
WWR
o Dropping of WKR1 Causes
W(R)R to pickup.
o Z1WR1(2) to pickup as
Z1WR1(1) was up due to
W(N)R pickup contact.
![Page 57: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/57.jpg)
57 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
(N)WLR3
W(N)R
Z1WR1
1 WKR3
W(N)R
B End
ND
A End
ND
N 110/60
B110
B 60
WKR3 Drop as W(R)R pickup (N TO R )
![Page 58: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/58.jpg)
58 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Z1RWR (N TO R ) Reverse Control initiation
WNR
Z1NWR
WWNR
W(R)R
W(R)LR
W(N)R
(N)WLR Z1RWR
Z1RWR
Z1RWR 1
2
o First Coil of Z1WR1 is pickup
with the press contacts of
buttons.
oHence Second coil of Z1WR1
is pickup.
![Page 59: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/59.jpg)
59
WKR2 picks up.
•Z1RWR UP.
•WR DOWN.
•WKR2 PICKS UP THROUGH 270 Ohms Resistance and then sticks through its own contacts. Because feed to Z1RWR Second Coil will cut off ,When (R)WLR 3 picks up
WKR 2 (N TO R )
WKR3
WKR2
Z1RWR Z1NWR WKR2
WR
270 Ohms
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 60: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/60.jpg)
60
WJR (N TO R )
Z1NWR Z1RWR
W(N)R
WKR3
WJR
WKR2
WJR 39 Ohms
250 mfd
(R)
WLR3
Z1WR1
WJR Point Timer Relay picks up…… o Z1RWR(2) is pick up. o WKR2 is pick up as out of correspondence
is established o Holding path is provided as Z1RWR will be
drop due to pickup of (R)WLR3. o WJR sticks through its own contact, and
control the feed for point operation for at least 10 Seconds.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 61: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/61.jpg)
11.8 11.9 11.10
(R)WLR1 (R)WLR3 (R)WLR2
¾.19 WR
Z1RWR
(N)WLR1
(N)WLR3
(N)WLR1 (N)WLR2
(R)WLR Reverse control locking
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 62: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/62.jpg)
62 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Z1RWR N TO R drops
WNR
Z1NWR
WWNR
W(R)R
W(R)LR
W(N)R
(N)WLR Z1RWR
Z1RWR Z1RWR
1
2 (N)WLR3
Z1RWR :
o First Coils up due to Button press contact,
hence second coil is prepared
o Z1RWR drop as (R)WLR3 Picks up
![Page 63: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/63.jpg)
63 S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
Z1RWR drop
WNR
Z1NWR
WWNR
W(R)R
W(R)LR
W(N)R
(N)WLR Z1RWR
Z1RWR
Z1RWR 1
2 (N)WLR3
R2 220 Ohms
o Pick up of (R)WLR3 relay short the supply.
o Hence an resistance of 220Ohms is provided
![Page 64: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/64.jpg)
64
WR (N to R)
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
WR
W(N)R
Z1NWR
Z1RWR
WKR2
WJR
WR
o Due to high inductance of WR Coil, caused by its initial pick up current surge, back e.m.f is generated causes a high current to be discharge through rectifier across it and to avoid interference of this current with other circuit WR back contact is included.
o WR Once picked up it will remain in pickup condition via R3 resistance, so the current consumption will be reduced.
R3 600 Ohms
![Page 65: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/65.jpg)
65
Z1WR1 Drops (N to R)
2
WR
W(R)R
Z1WR1
Z1WR1
oFinally pickup of WR relay Cut off the supply of Z1WR1 relay.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 66: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/66.jpg)
66
Point is in Normal. o Machine contacts no.2,2a(R.C) & 3,3a(ND) is making. o As a Right Hand Cross over machine no.1 will operate first and through the make contact of machine no.1 machine no.2 will operate.
Point machine operation (N to R)
WR
W(R)R
(R)WLR
RC(1ST M)
RD(1ST M)
RC(2nd M)
W(R)R
WR
W(N)R
B 110 N 110
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 67: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/67.jpg)
Point Lock & Detection Sequence WR
Motor Z1WR1
WKR3
WJR WKR2
WR
W(N)R
WKR3
WKR1
WKR3(1)
W(R)LR
NWKR or RWKR Z2WR1 or Z2WR2
![Page 68: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/68.jpg)
68
WKR3 PICKS UP 110VDC(N to R )
WR
W(R)R
(R)WLR
B 110 N 110
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
RD(1ST M)
RD(2ND M)
W(N)R
W(N)R o WKR3 picks up by 110 V Operation supply to prove the “End of point” Operation. An resistance of 1000 Ohms /1W is provided across the coil of WKR3 relay, to protect the coil of this relay, when its picks up by 110 V.DC supply.
1000
Ohms
WKR3
![Page 69: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/69.jpg)
69
WKR 2 drops(N to R )
WKR3
WKR2
Z1RWR Z1NWR WKR2
WR
270 Ohms Pick up of WKR3 drops WKR2 relay.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 70: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/70.jpg)
70
WJR drop (N to R)
Z1NWR Z1RWR
W(N)R
WKR3
WJR
WKR2
WJR 39 Ohms
250 mfd
(R)
WLR3
Z1WR1 Pick up of WKR3 drops WJR relay.
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 71: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/71.jpg)
71
WR Drops (N to R)
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
WR
W(N)R
Z1NWR
Z1RWR
WKR2
WJR
WR
R3 600 Ohms
![Page 72: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/72.jpg)
72
W(N)R PICK UP(N to R )
WR
WKR2
W(R)R
W(N)R
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 73: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/73.jpg)
73
WKR3 Drops(N to R )
WR
W(R)R
(R)WLR
B 110 N 110
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
RD(1ST M)
RD(2ND M)
W(N)R
W(N)R
1000
Ohms
WKR3
![Page 74: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/74.jpg)
74
WKR1 (Reverse Detection)
WKR2
WKR3
W(R)R
M2
NC
(R)WLR3
WKR1
WKR2
W(R)R RD 1ST MC
RD 2nd MC
(R)WLR3
WJR
W(R)R
S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0
![Page 75: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/75.jpg)
(R)WLR3 (R)WLR3
W(N)LR
W(N)LR
(N)WLR3
W(N)LR W(N)LR
W(R)LR
Z2 WR1
Z2 WR2
WK
R1
CH
(Y)N
R
B U(R)S A U(R)S
Z1WR
W(N)R
W(R)LR (Point locking)
![Page 76: S-16 Route Setting type Relay Interlocking122.252.230.113/content/ppt/sig/S16.pdf · 2020. 9. 30. · S 16 Route Relay Interlocking (Siemens) IRISET Ver 1.0 Control Table S 1 C-ON](https://reader036.vdocuments.mx/reader036/viewer/2022070212/6104eb548589d905c50cbf56/html5/thumbnails/76.jpg)
THANK YOU