rulon endure 800 series linear suspended engineered ...€¦ · a. suspension systems and...
TRANSCRIPT
6/23/2015
- 1 -
RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS
ARCHITECTURAL SPECIFICATIONS
PART 1 - GENERAL
A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.
B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.
C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.
1.01 SCOPE
A. Rulon International shall furnish suspension carrier system, Endure ceiling strips and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.
1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION
A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.
B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.
C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.
RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 2 -
1.04 COORDINATION OF WORK
A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.
1.05 SUBMITTALS
A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.
B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.
C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.
1.06 DELIVERY, STORAGE, AND HANDLING
A. All materials shall be delivered to the project site in original, labeled, unopened packages.
B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.
C. Care in handling must be exercised to avoid damage.
1.07 WARRANTIES
A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.
B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.
RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 3 -
PART 2 - PRODUCT
2.01 ENGINEERED POLYMER STRIPS
A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #800 series in [specified color] [with or without] spacers. The spacers, in [specified color], shall be installed between the edges of each strip, with the flat face visible.
B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) spacers between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.
2.02 SUSPENSION SYSTEMS
A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.
B. Hangers to support carriers shall be #12-gauge steel wire.
2.03 EDGES, BORDERS, AND PERIMETER TRIM
A. Edges, borders, and perimeter trims shall be standard design, as manufactured by Rulon International.
2.04 COLORS
A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.
PART 3 - EXECUTION
3.01 PREPARATION
A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.
RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 4 -
B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.
3.02 INSTALLATION
A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.
B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.
C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.
D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.
E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.
3.03 ADJUSTMENT, CLEANING, AND REPAIR
A. The contractor shall make final adjustments to level or contours.
B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.
C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.
RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 5 -
3.04 INSPECTION
A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.
6/23/2015
- 1 -
RULON ENDURE 850 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS
ARCHITECTURAL SPECIFICATIONS
PART 1 - GENERAL
A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400 Fax: 904-584-1499, www.rulonco.com.
B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.
C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.
1.01 SCOPE
A. Rulon International shall furnish suspension carrier system, Endure ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.
1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION
A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.
B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.
C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.
RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 2 -
1.04 COORDINATION OF WORK
A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.
1.05 SUBMITTALS
A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.
B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.
C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.
1.06 DELIVERY, STORAGE, AND HANDLING
A. All materials shall be delivered to the project site in original, labeled, unopened packages.
B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.
C. Care in handling must be exercised to avoid damage.
1.07 WARRANTIES
A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.
B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.
RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 3 -
PART 2 - PRODUCT
2.0 ENGINEERED POLYMER STRIPS
A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be 850 series in [specified color] [with or without] spacers. The spacers, in [specified color], shall be installed between the edges of each strip, with the curved face visible.
B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) space between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.
2.02 SUSPENSION SYSTEMS
A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.
B. Hangers to support carriers shall be #12-gauge steel wire.
2.03 EDGES, BORDERS, AND PERIMETER TRIM
A. Edges, borders, and perimeter trims shall be standard design, as manufactured by Rulon International.
2.04 COLORS
A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.
PART 3 - EXECUTION
3.01 PREPARATION
A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.
RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 4 -
B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.
3.02 INSTALLATION
A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.
B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.
C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.
D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.
E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.
3.03 ADJUSTMENT, CLEANING, AND REPAIR
A. The contractor shall make final adjustments to level or contours.
B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.
C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.
RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 5 -
3.04 INSPECTION
A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.
6/23/2015
- 1 -
RULON ENDURE 900 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS
ARCHITECTURAL SPECIFICATIONS
PART 1 - GENERAL
A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.
B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.
C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.
1.01 SCOPE
A. Rulon International shall furnish suspension carrier system, Endure ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.
1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION
A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.
B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.
C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.
RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 2 -
1.04 COORDINATION OF WORK
A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.
1.05 SUBMITTALS
A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.
B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.
C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.
1.06 DELIVERY, STORAGE, AND HANDLING
A. All materials shall be delivered to the project site in original, labeled, unopened packages.
B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.
C. Care in handling must be exercised to avoid damage.
1.07 WARRANTIES
A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.
B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.
PART 2 - PRODUCT
2.01 ENGINEERED POLYMER STRIPS
A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #900 straight edge strip in [specified color].
RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 3 -
B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide face with a 3/4" (19mm) recess at one side of the strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.
2.02 SUSPENSION SYSTEMS
A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and galvanized. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.
B. Hangers to support carriers shall be #12-gauge steel wire.
2.03 EDGES, BORDERS, AND PERIMETER TRIM
A. Edges, borders, and perimeter trims shall be #870 perimeter trim, as manufactured by Rulon International.
2.04 COLORS
A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.
PART 3 - EXECUTION
3.01 PREPARATION
A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.
B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.
3.02 INSTALLATION
A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.
RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 4 -
B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.
C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.
D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.
E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.
3.03 ADJUSTMENT, CLEANING, AND REPAIR
A. The contractor shall make final adjustments to level or contours.
B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.
C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.
3.04 INSPECTION
A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.
6/23/2015
- 1 -
RULON ENDURE WOODGRAIN 800 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS
ARCHITECTURAL SPECIFICATIONS
PART 1 - GENERAL
A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.
B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.
C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.
1.01 SCOPE
A. Rulon International shall furnish suspension carrier system, Endure Woodgrain ceiling strips and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.
1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION
A. Suspension systems and components for ceilings, other than manufacturer's Endure Woodgrain Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.
B. Fire Performance Characteristics: Rulon Endure Woodgrain Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.
C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.
RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 2 -
1.04 COORDINATION OF WORK
A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.
1.05 SUBMITTALS
A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.
B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.
C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.
1.06 DELIVERY, STORAGE, AND HANDLING
A. All materials shall be delivered to the project site in original, labeled, unopened packages.
B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.
C. Care in handling must be exercised to avoid damage.
1.07 WARRANTIES
A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.
B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.
RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 3 -
PART 2 - PRODUCT
2.01 ENGINEERED POLYMER STRIPS
A. Engineered Polymer ceiling strips shall be of Rulon Endure Woodgrain manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #800 series [with or without] spacers.
B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) spacers between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.
2.02 SUSPENSION SYSTEMS
A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.
B. Hangers to support carriers shall be #12-gauge steel wire.
2.03 EDGES, BORDERS, AND PERIMETER TRIM
A. Edges, borders, and perimeter trims shall be standard design matching woodgrain #870 Perimeter trim, as manufactured by Rulon International.
2.04 COLORS
A. All Engineered Polymer strips shall be factory-manufactured in the finish selected for the project.
PART 3 - EXECUTION
3.01 PREPARATION
A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.
RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 4 -
B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.
3.02 INSTALLATION
A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.
B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.
C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (914mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.
D. Engineered Polymer Strip Installation: Rulon Endure Woodgrain Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.
E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.
3.03 ADJUSTMENT, CLEANING, AND REPAIR
A. The contractor shall make final adjustments to level or contours.
B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.
C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.
RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 5 -
3.04 INSPECTION
A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.
6/23/2015
- 1 -
RULON ENDURE WOODGRAIN 900 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS
ARCHITECTURAL SPECIFICATIONS
PART 1 - GENERAL
A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.
B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.
C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.
1.01 SCOPE
A. Rulon International shall furnish suspension carrier system, Endure Woodgrain ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.
1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION
A. Suspension systems and components for ceilings, other than manufacturer's Endure Woodgrain Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.
B. Fire Performance Characteristics: Rulon Endure Woodgrain Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.
C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.
RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 2 -
1.04 COORDINATION OF WORK
A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.
1.05 SUBMITTALS
A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.
B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.
C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.
1.06 DELIVERY, STORAGE, AND HANDLING
A. All materials shall be delivered to the project site in original, labeled, unopened packages.
B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.
C. Care in handling must be exercised to avoid damage.
1.07 WARRANTIES
A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.
B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.
PART 2 - PRODUCT
2.01 ENGINEERED POLYMER STRIPS
A. Engineered Polymer ceiling strips shall be of Rulon Endure Woodgrain manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #900 straight edge strip with integral spacer.
RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 3 -
B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide face with a 3/4" (19mm) recess at one side of the strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.
2.02 SUSPENSION SYSTEMS
A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and galvanized. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.
B. Hangers to support carriers shall be #12-gauge steel wire.
2.03 EDGES, BORDERS, AND PERIMETER TRIM
A. Edges, borders, and perimeter trims shall be matching woodgrain #870 perimeter trim, as manufactured by Rulon International.
2.04 COLORS
A. All Engineered Polymer strips shall be factory-manufactured in the finish selected for the project.
PART 3 - EXECUTION
3.01 PREPARATION
A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.
B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.
3.02 INSTALLATION
A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.
RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS
- 4 -
B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.
C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.
D. Engineered Polymer Strip Installation: Rulon Endure Woodgrain Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.
E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.
3.03 ADJUSTMENT, CLEANING, AND REPAIR
A. The contractor shall make final adjustments to level or contours.
B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.
C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.
3.04 INSPECTION
A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
DRAWING #
P8000001 P9000010
TITLE
ENDURE #800 Profile - Straight Edge
Strips
DRAWING # TITLE
ENDURE Access Panel Detail
P8500001
ENDURE #850 Profile - Round Edge Strips
P9000002
ENDURE #870 Perimeter Trim
PXX00003
ENDURE #890 Carrier Connector
P8500004
ENDURE #850S Splice Material
P9000005
ENDURE #875 Expansion Joint
P9000006
ENDURE Exterior Installation - Spacing
PXX00007
ENDURE Strut Detail - Exterior Installation
P9000008
ENDURE Recessed Can Light Detail
P9000009
ENDURE Linear Light Fixture
P9000001
ENDURE #900 Profile
P8500011
ENDURE Ceiling Installation
Detail - Interior
PXX00012
ENDURE Direct Mount Detail
ENDURE 850 with #860 Spacer Shown
ENDURE Index
PXXINDEX
CAP
TRJUL/08/2015
3
1
4
" [82 mm]
3
4
" [19 mm]
1" [25 mm]
1" [25 mm]
#860 SPACER
OPTION #1
WITH SPACER
OPTION #2
WITHOUT SPACER
1" [25 mm]
1" [25 mm]
3
1
4
" [84 mm]
3
4
" [18 mm]
ENDURE #800 Profile - Straight
Edge Strips
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P8000001
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
APR/07/2017
3
1
4
" [84 mm]
3
4
" [18 mm]
1" [25 mm]
1" [25 mm]
3
1
4
" [84 mm]
3
4
" [18 mm]
1" [25 mm]
1" [25 mm]
#860 SPACER
OPTION #1
WITH SPACER
OPTION #2
WITHOUT SPACER
NOTE: SPACER MAY ALSO BE ORIENTED
WITH CURVED EDGE FACING CARRIER
ENDURE #850 Profile - Round
Edge Strips
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P8500001
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
APR/07/2017
#900 ENDURE WITH
INTEGRATED SPACER
1" [25 mm]
1" [25 mm]
4" [102 mm]
ENDURE #900 Profile
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000001
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
APR/07/2017
PERIMETER TRIM #870
SIDE INSTALLATION END INSTALLATION
NOTE:
ALLOW SUFFICIENT SPACE FOR EXPANSION
AT PERIMETER. SEE INSTALLATION GUIDE
FOR MORE INFORMATION
WA
LL
WA
LL
A B
#870 PERIMETER TRIM CROSS-SECTION
C
9
16
" [15 mm]
1
1
16
" [27 mm]
1
3
16
" [31 mm]
MATERIAL
THICKNESS =
1
16
"
[2 mm]
ENDURE #870 Perimeter Trim
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000002
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
CARRIER
CONNECTOR #890
USE #12 UNC BOLT
WITH NUT
(NOT BY RULON)
TO SECURE
CONNECTOR TO
CARRIERS
ENDURE CARRIER #880
2" [51 mm]
MODULE
REPEAT
NOTE:
CARRIER CONNECTOR IS FOR
ALIGNMENT ONLY. SUPPORT
CARRIER AS NEEDED NEAR SPLICE.
INSTALLATION TIP:
CARRIER CONNECTOR IS DESIGNED TO
BE POSITIONED INSIDE (AS SHOWN) OR
OUTSIDE OF THE CARRIER; ATTACHED
THROUGH HOLES IN TOP (AS SHOWN)
OR SIDES
Tip
ENDURE #890 Carrier Connector
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
PXX00003
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
3" PIECE OF #850
ENDURE
CEILING STRIP IS
INSERTED AND
CENTERED AT JOINT
NOTE:
USE PVC CEMENT
TO SECURE SPLICE
STRIP IN PLACE
NOTE:
ON ENDURE
WOODGRAIN TAKE
CARE NOT TO GET
PVC CEMENT ON
WOODGRAIN FILM
ENDURE #850S Splice Material
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P8500004
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
SEP/05/2014
#880 CARRIER
6" MAX.
[152 mm]
6" MAX.
[152 mm]
CUT PANELS TO ALLOW SPACE FOR
SUFFICIENT EXPANSION AND CONTRACTION.
SEE INSTALLATION GUIDE OR CONTACT
RULON TECHNICAL SUPPORT FOR MORE
INFORMATION.
1" [25 mm] L-ANGLE
(NOT BY RULON)
3'-0" [914 mm] O.C.
MAX. ATTACHED
TO CARRIER
#875 EXPANSION JOINT
L-BRACKET (NOT BY
RULON) ATTACHED
WITH SCREWS TO
EXPANSION JOINT
ENDURE CEILING STRIP
ENDURE CEILING STRIP
ENDURE #875 Expansion Joint
Detail
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000005
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
STRUTS AND #12-GA.
HANGER WIRE
(NOT BY RULON). SEE
DRAWING PXX00007
FOR INSTALLATION
DETAILS.
#880 ENDURE
CARRIER
4'-0" [1226 mm]
TYP.
3'-0" [914 mm] O.C.
MAX.
6" [152 mm] MAX.
AT TERMINATIONS
NOTE: CONTACT RULON
TECHNICAL DEPARTMENT
FOR HIGH WINDLOAD
APPLICATIONS
ENDURE Exterior Installation -
Spacing
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000006
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
2" [51 mm]
FIELD
MEASUREMENT
STRUCTURE
90°
NOTE:
CUT LEGS OF
CHANNEL AND BEND
TO PERMIT
ATTACHMENT TO
STRUCTURE AND
CARRIER.
90°
APPROPRIATE
FASTENERS
(NOT BY RULON)
STRUT NOT
BY RULON
1
1
2
"
[38 mm]
2
1
2
"
[64 mm]
20-GA.
CHANNEL STRUT
CROSS-SECTION,
TYPICAL
ENDURE Strut Detail - Exterior
Installation
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
PXX00007
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
ATTACHMENTS FOR
LATERAL STABILITY
ONLY
LIGHT FIXTURE
MUST BE
INDEPENDENTLY
SUPPORTED
ENDURE Recessed Can Light
Detail
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000008
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
NOTE:
CEILING CARRIER SUPPORTS
OMITTED FOR CLARITY
LIGHT FIXTURE MUST BE
INDEPENDENTLY SUPPORTED
USE SHORT PIECES OF
CARRIER TO BRIDGE
AROUND LIGHT ENDS
ENDURE
CEILING
LINEAR FIXTURE
(NOT BY RULON)
ENDURE with Linear Light Fixture
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000009
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUL/08/2015
FIELD-NOTCH AND ATTACH
1" [25 mm] L-ANGLE
(NOT BY RULON)
SUSPEND ADDITIONAL
PIECES OF RULON
CARRIER AS NEEDED
PLAN VIEW
(ACCESS PANEL PARTIALLY OPEN)
2' [610 mm] X 2' [610 mm] ACCESS PANEL SHOWN
(SIZE VARIES PER PROJECT)
SEE HINGE DETAIL BELOW
SEE LATCH DETAIL BELOW
NOTE: RULON PERIMETER
TRIM CAN BE USED TO
CONCEAL "CORE" OF
MATERIAL
1" [25 mm] L-ANGLE ATTACHED TO ENDURE CARRIER
WITH MACHINE SCREWS AND NUTS (NOT BY RULON)
1
1
2" [38 mm] DOOR
HINGE, ATTACHED
TO L-ANGLE WITH
MACHINE SCREWS
AND NUTS
(NOT BY RULON)
REMOVE INTEGRAL
SPACER IN FIELD
WITH ROUTER
(ENDURE 900
ONLY)
LATCH DETAIL
(SHOWN CLOSED)
HINGE DETAIL
(SHOWN CLOSED)
ENDURE Access Panel Detail
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P9000010
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
#12-GAUGE WIRE
HANGERS (NOT BY RULON)
4' [1219 mm] O.C. ALONG
CARRIERS
#880 CARRIERS
3' [914 mm] O.C. MAX.
(POOL OR REC.
AREA 2' O.C. MAX.)
#860 SPACERS (NOT
REQUIRED WITH #900
SYSTEM)
#850 (SHOWN), #800
OR #900 STRIPS
ENDURE Ceiling Installation
Detail - Interior
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
P8500011
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com
JUN/23/2015
SHIM UNDER STUDS WHERE
NECESSARY TO LEVEL THE CARRIERS
METAL STUDS
OR STRUCTURE
ATTACH #880 CARRIER TO METAL STUDS
USING SCREWS 3' [914 mm] ON CENTER
#880 CARRIER
#880 CARRIER
SHIM
METAL
STUD
ENDURE Direct Mount Detail
ISSUE DATE: PROJECT NUMBER:
REVISION DATE: DRAWING NUMBER:
PXX00012
PROJECT:
TITLE:
DRAWN BY:
CHECKED BY:
CAP
TR
World Commerce Center
2000 Ring Way Road
St. Augustine, FL 32092
Ph: 1-800-227-8566
904-584-1400
Fax: 904-584-1499
www.rulonco.com