6/23/2015 - 1 - RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS PART 1 - GENERAL A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com. B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder. C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative. 1.01 SCOPE A. Rulon International shall furnish suspension carrier system, Endure ceiling strips and designated accessories required to complete installation by the contractor - in compliance with plans and specifications. 1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included. 1.03 QUALITY ASSURANCE A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative. B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84. C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Upload: others

Post on 01-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

6/23/2015

- 1 -

RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS

ARCHITECTURAL SPECIFICATIONS

PART 1 - GENERAL

A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.

B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.

C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.

1.01 SCOPE

A. Rulon International shall furnish suspension carrier system, Endure ceiling strips and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.

1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION

A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.

1.03 QUALITY ASSURANCE

A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.

B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.

C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Page 2: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 2 -

1.04 COORDINATION OF WORK

A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.

1.05 SUBMITTALS

A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.

B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.

C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.

1.06 DELIVERY, STORAGE, AND HANDLING

A. All materials shall be delivered to the project site in original, labeled, unopened packages.

B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.

C. Care in handling must be exercised to avoid damage.

1.07 WARRANTIES

A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.

B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.

Page 3: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 3 -

PART 2 - PRODUCT

2.01 ENGINEERED POLYMER STRIPS

A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #800 series in [specified color] [with or without] spacers. The spacers, in [specified color], shall be installed between the edges of each strip, with the flat face visible.

B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) spacers between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.

2.02 SUSPENSION SYSTEMS

A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.

B. Hangers to support carriers shall be #12-gauge steel wire.

2.03 EDGES, BORDERS, AND PERIMETER TRIM

A. Edges, borders, and perimeter trims shall be standard design, as manufactured by Rulon International.

2.04 COLORS

A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.

PART 3 - EXECUTION

3.01 PREPARATION

A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.

Page 4: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 4 -

B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.

3.02 INSTALLATION

A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.

B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.

C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.

D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.

E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.

3.03 ADJUSTMENT, CLEANING, AND REPAIR

A. The contractor shall make final adjustments to level or contours.

B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.

C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.

Page 5: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 5 -

3.04 INSPECTION

A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.

Page 6: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

6/23/2015

- 1 -

RULON ENDURE 850 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS

ARCHITECTURAL SPECIFICATIONS

PART 1 - GENERAL

A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400 Fax: 904-584-1499, www.rulonco.com.

B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.

C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.

1.01 SCOPE

A. Rulon International shall furnish suspension carrier system, Endure ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.

1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION

A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.

1.03 QUALITY ASSURANCE

A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.

B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.

C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Page 7: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 2 -

1.04 COORDINATION OF WORK

A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.

1.05 SUBMITTALS

A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.

B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.

C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.

1.06 DELIVERY, STORAGE, AND HANDLING

A. All materials shall be delivered to the project site in original, labeled, unopened packages.

B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.

C. Care in handling must be exercised to avoid damage.

1.07 WARRANTIES

A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.

B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.

Page 8: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 3 -

PART 2 - PRODUCT

2.0 ENGINEERED POLYMER STRIPS

A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be 850 series in [specified color] [with or without] spacers. The spacers, in [specified color], shall be installed between the edges of each strip, with the curved face visible.

B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) space between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.

2.02 SUSPENSION SYSTEMS

A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.

B. Hangers to support carriers shall be #12-gauge steel wire.

2.03 EDGES, BORDERS, AND PERIMETER TRIM

A. Edges, borders, and perimeter trims shall be standard design, as manufactured by Rulon International.

2.04 COLORS

A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.

PART 3 - EXECUTION

3.01 PREPARATION

A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.

Page 9: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 4 -

B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.

3.02 INSTALLATION

A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.

B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.

C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.

D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.

E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.

3.03 ADJUSTMENT, CLEANING, AND REPAIR

A. The contractor shall make final adjustments to level or contours.

B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.

C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.

Page 10: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 850 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 5 -

3.04 INSPECTION

A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.

Page 11: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

6/23/2015

- 1 -

RULON ENDURE 900 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS

ARCHITECTURAL SPECIFICATIONS

PART 1 - GENERAL

A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.

B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.

C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.

1.01 SCOPE

A. Rulon International shall furnish suspension carrier system, Endure ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.

1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION

A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.

1.03 QUALITY ASSURANCE

A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.

B. Fire Performance Characteristics: Rulon Endure Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.

C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Page 12: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 2 -

1.04 COORDINATION OF WORK

A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.

1.05 SUBMITTALS

A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.

B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.

C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.

1.06 DELIVERY, STORAGE, AND HANDLING

A. All materials shall be delivered to the project site in original, labeled, unopened packages.

B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.

C. Care in handling must be exercised to avoid damage.

1.07 WARRANTIES

A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.

B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.

PART 2 - PRODUCT

2.01 ENGINEERED POLYMER STRIPS

A. Engineered Polymer ceiling strips shall be of Rulon Endure manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #900 straight edge strip in [specified color].

Page 13: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 3 -

B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide face with a 3/4" (19mm) recess at one side of the strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.

2.02 SUSPENSION SYSTEMS

A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and galvanized. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.

B. Hangers to support carriers shall be #12-gauge steel wire.

2.03 EDGES, BORDERS, AND PERIMETER TRIM

A. Edges, borders, and perimeter trims shall be #870 perimeter trim, as manufactured by Rulon International.

2.04 COLORS

A. All Engineered Polymer strips shall be factory-manufactured in the color, or finish, selected for the project.

PART 3 - EXECUTION

3.01 PREPARATION

A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.

B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.

3.02 INSTALLATION

A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.

Page 14: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 4 -

B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.

C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.

D. Engineered Polymer Strip Installation: Rulon Endure Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.

E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.

3.03 ADJUSTMENT, CLEANING, AND REPAIR

A. The contractor shall make final adjustments to level or contours.

B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.

C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.

3.04 INSPECTION

A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.

Page 15: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

6/23/2015

- 1 -

RULON ENDURE WOODGRAIN 800 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS

ARCHITECTURAL SPECIFICATIONS

PART 1 - GENERAL

A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.

B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.

C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.

1.01 SCOPE

A. Rulon International shall furnish suspension carrier system, Endure Woodgrain ceiling strips and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.

1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION

A. Suspension systems and components for ceilings, other than manufacturer's Endure Woodgrain Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.

1.03 QUALITY ASSURANCE

A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.

B. Fire Performance Characteristics: Rulon Endure Woodgrain Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.

C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Page 16: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 2 -

1.04 COORDINATION OF WORK

A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.

1.05 SUBMITTALS

A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.

B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.

C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.

1.06 DELIVERY, STORAGE, AND HANDLING

A. All materials shall be delivered to the project site in original, labeled, unopened packages.

B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.

C. Care in handling must be exercised to avoid damage.

1.07 WARRANTIES

A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.

B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.

Page 17: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 3 -

PART 2 - PRODUCT

2.01 ENGINEERED POLYMER STRIPS

A. Engineered Polymer ceiling strips shall be of Rulon Endure Woodgrain manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #800 series [with or without] spacers.

B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide, with 3/4" (19mm) spacers between strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.

2.02 SUSPENSION SYSTEMS

A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and painted. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.

B. Hangers to support carriers shall be #12-gauge steel wire.

2.03 EDGES, BORDERS, AND PERIMETER TRIM

A. Edges, borders, and perimeter trims shall be standard design matching woodgrain #870 Perimeter trim, as manufactured by Rulon International.

2.04 COLORS

A. All Engineered Polymer strips shall be factory-manufactured in the finish selected for the project.

PART 3 - EXECUTION

3.01 PREPARATION

A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.

Page 18: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 4 -

B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.

3.02 INSTALLATION

A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.

B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.

C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (914mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.

D. Engineered Polymer Strip Installation: Rulon Endure Woodgrain Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When spacers and acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.

E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.

3.03 ADJUSTMENT, CLEANING, AND REPAIR

A. The contractor shall make final adjustments to level or contours.

B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, spacers, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.

C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.

Page 19: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 800 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 5 -

3.04 INSPECTION

A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.

Page 20: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

6/23/2015

- 1 -

RULON ENDURE WOODGRAIN 900 SERIES LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS

ARCHITECTURAL SPECIFICATIONS

PART 1 - GENERAL

A. The linear Engineered Polymer ceiling systems covered by this specification shall be the products of the Rulon International, World Commerce Center, 2000 Ring Way Road, St. Augustine, FL 32092. Phone: 800-227-8566, 904-584-1400, Fax: 904-584-1499, www.rulonco.com.

B. The General Conditions and the requirements of Division 1 of the specifications shall apply to all work hereunder.

C. All work shall be completed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative.

1.01 SCOPE

A. Rulon International shall furnish suspension carrier system, Endure Woodgrain ceiling strips, and designated accessories required to complete installation by the contractor - in compliance with plans and specifications.

1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION

A. Suspension systems and components for ceilings, other than manufacturer's Endure Woodgrain Linear Suspended Engineered Polymer Ceiling Systems, shall not be included.

1.03 QUALITY ASSURANCE

A. Installer Qualifications: The contractor shall be a qualified installer with no less than (2) two years of successful experience in installation of suspended ceilings with requirements similar to this project. The contractor shall be acceptable to the architect, manufacturer, and owner's representative.

B. Fire Performance Characteristics: Rulon Endure Woodgrain Linear Suspended Engineered Polymer Ceiling System is "Fire Resistant" - receiving a Class 1, or A flame spread rating, when tested in accordance with ASTM E-84.

C. Acoustical Characteristics: Acoustical performance shall be enhanced by placement of sound-absorbing material above the Engineered Polymer ceiling strips. Sound absorption varies with the thickness of the absorption material used.

Page 21: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 2 -

1.04 COORDINATION OF WORK

A. The layout and installation of Engineered Polymer ceiling and suspension system components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components.

1.05 SUBMITTALS

A. Product Data: Rulon International shall provide product specifications and installation instructions for all supplied ceiling materials.

B. Shop Drawings: When required, Rulon International shall supply shop drawings outlining the placement of hangers and the location of carriers, and any other details necessary for proper installation.

C. Samples: A 9” (229mm) wide x 12” (305mm) long sample shall be submitted for approval. The sample shall consist of 3 ceiling strips of the style and color specified assembled onto the carrier.

1.06 DELIVERY, STORAGE, AND HANDLING

A. All materials shall be delivered to the project site in original, labeled, unopened packages.

B. Materials shall be stored flat and level in a fully enclosed space, preferably in the room in which they are to be installed.

C. Care in handling must be exercised to avoid damage.

1.07 WARRANTIES

A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one (1) year.

B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work.

PART 2 - PRODUCT

2.01 ENGINEERED POLYMER STRIPS

A. Engineered Polymer ceiling strips shall be of Rulon Endure Woodgrain manufacture. The strips are designed to connect onto the Rulon suspension carrier. The Engineered Polymer strip pattern shall be #900 straight edge strip with integral spacer.

Page 22: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 3 -

B. Pattern dimensions shall be: 4" (102mm) modules, consisting of Engineered Polymer strips 3-1/4" (83mm) wide face with a 3/4" (19mm) recess at one side of the strips. Cut ends of Engineered Polymer strips shall have clean, square cuts, butted together, and connected on the back side with a piece of cut Engineered Polymer #850 splicer strip snapped tightly between the strips to ensure alignment.

2.02 SUSPENSION SYSTEMS

A. The standard suspension carrier shall be of Rulon manufacture, and consist of commercial grade steel with surface prepared, and galvanized. In swimming pool and other corrosive environments, use the Rulon carrier coated with a black protective coating system.

B. Hangers to support carriers shall be #12-gauge steel wire.

2.03 EDGES, BORDERS, AND PERIMETER TRIM

A. Edges, borders, and perimeter trims shall be matching woodgrain #870 perimeter trim, as manufactured by Rulon International.

2.04 COLORS

A. All Engineered Polymer strips shall be factory-manufactured in the finish selected for the project.

PART 3 - EXECUTION

3.01 PREPARATION

A. Ceiling Layout: Contractor shall measure ceiling areas and establish layout of hangers and carriers, in accordance with installation instructions.

B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field.

3.02 INSTALLATION

A. General: The contractor shall install materials in accordance with Rulon International printed instructions. The installation will comply with applicable regulations and industry standards.

Page 23: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

RULON ENDURE WOODGRAIN 900 LINEAR SUSPENDED ENGINEERED POLYMER CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

- 4 -

B. Perimeters: Using a leveling device, the contractor shall lay out and install perimeter trim, as specified.

C. Suspensions: Rulon Endure carriers shall be placed perpendicular to the desired Engineered Polymer strip direction, and positioned on 3' (915mm) or 2’ (610mm) centers - as specified by the manufacturer. Carriers shall be suspended from specified hangers - starting 6" (152mm) from one wall, then on specified centers, with the last carrier positioned within 6" (152mm) of the other wall. Specified hangers shall be attached directly to structure, or to inserts, screw eyes, or other devices that are secure, and that will not deteriorate or fail with age or elevated temperatures.

D. Engineered Polymer Strip Installation: Rulon Endure Woodgrain Engineered Polymer strips shall be fully attached to the carrier by snapping one side of the strip into position first, followed by the second side. When properly installed, the strips shall be firmly secured, and fully level. When acoustical blankets are specified, they shall be fitted as the installation of strips progresses. End cuts are butted tight together by snapping a short piece of #850 ceiling material, behind the strips, to create a secure, aligned joint.

E. HVAC and Light Fixture Suspensions: Electrical and mechanical installations shall be supported independently of the linear Engineered Polymer ceiling.

3.03 ADJUSTMENT, CLEANING, AND REPAIR

A. The contractor shall make final adjustments to level or contours.

B. Upon completion of the ceiling installation, the contractor shall clean all Engineered Polymer strips, and borders of dirt, dust, grease, oils, and fingerprints, etc. - using liquid detergent on a clean cloth.

C. All work that cannot be successfully cleaned and repaired shall be removed and replaced.

3.04 INSPECTION

A. Upon completion of the ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that the work has been completed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner, or to ceiling manufacturer.

Page 24: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

DRAWING #

P8000001 P9000010

TITLE

ENDURE #800 Profile - Straight Edge

Strips

DRAWING # TITLE

ENDURE Access Panel Detail

P8500001

ENDURE #850 Profile - Round Edge Strips

P9000002

ENDURE #870 Perimeter Trim

PXX00003

ENDURE #890 Carrier Connector

P8500004

ENDURE #850S Splice Material

P9000005

ENDURE #875 Expansion Joint

P9000006

ENDURE Exterior Installation - Spacing

PXX00007

ENDURE Strut Detail - Exterior Installation

P9000008

ENDURE Recessed Can Light Detail

P9000009

ENDURE Linear Light Fixture

P9000001

ENDURE #900 Profile

P8500011

ENDURE Ceiling Installation

Detail - Interior

PXX00012

ENDURE Direct Mount Detail

ENDURE 850 with #860 Spacer Shown

ENDURE Index

PXXINDEX

CAP

TRJUL/08/2015

Page 25: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

3

1

4

" [82 mm]

3

4

" [19 mm]

1" [25 mm]

1" [25 mm]

#860 SPACER

OPTION #1

WITH SPACER

OPTION #2

WITHOUT SPACER

1" [25 mm]

1" [25 mm]

3

1

4

" [84 mm]

3

4

" [18 mm]

ENDURE #800 Profile - Straight

Edge Strips

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P8000001

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

APR/07/2017

Page 26: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

3

1

4

" [84 mm]

3

4

" [18 mm]

1" [25 mm]

1" [25 mm]

3

1

4

" [84 mm]

3

4

" [18 mm]

1" [25 mm]

1" [25 mm]

#860 SPACER

OPTION #1

WITH SPACER

OPTION #2

WITHOUT SPACER

NOTE: SPACER MAY ALSO BE ORIENTED

WITH CURVED EDGE FACING CARRIER

ENDURE #850 Profile - Round

Edge Strips

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P8500001

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

APR/07/2017

Page 27: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

#900 ENDURE WITH

INTEGRATED SPACER

1" [25 mm]

1" [25 mm]

4" [102 mm]

ENDURE #900 Profile

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000001

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

APR/07/2017

Page 28: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

PERIMETER TRIM #870

SIDE INSTALLATION END INSTALLATION

NOTE:

ALLOW SUFFICIENT SPACE FOR EXPANSION

AT PERIMETER. SEE INSTALLATION GUIDE

FOR MORE INFORMATION

WA

LL

WA

LL

A B

#870 PERIMETER TRIM CROSS-SECTION

C

9

16

" [15 mm]

1

1

16

" [27 mm]

1

3

16

" [31 mm]

MATERIAL

THICKNESS =

1

16

"

[2 mm]

ENDURE #870 Perimeter Trim

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000002

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 29: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

CARRIER

CONNECTOR #890

USE #12 UNC BOLT

WITH NUT

(NOT BY RULON)

TO SECURE

CONNECTOR TO

CARRIERS

ENDURE CARRIER #880

2" [51 mm]

MODULE

REPEAT

NOTE:

CARRIER CONNECTOR IS FOR

ALIGNMENT ONLY. SUPPORT

CARRIER AS NEEDED NEAR SPLICE.

INSTALLATION TIP:

CARRIER CONNECTOR IS DESIGNED TO

BE POSITIONED INSIDE (AS SHOWN) OR

OUTSIDE OF THE CARRIER; ATTACHED

THROUGH HOLES IN TOP (AS SHOWN)

OR SIDES

Tip

ENDURE #890 Carrier Connector

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

PXX00003

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 30: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

3" PIECE OF #850

ENDURE

CEILING STRIP IS

INSERTED AND

CENTERED AT JOINT

NOTE:

USE PVC CEMENT

TO SECURE SPLICE

STRIP IN PLACE

NOTE:

ON ENDURE

WOODGRAIN TAKE

CARE NOT TO GET

PVC CEMENT ON

WOODGRAIN FILM

ENDURE #850S Splice Material

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P8500004

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

SEP/05/2014

Page 31: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

#880 CARRIER

6" MAX.

[152 mm]

6" MAX.

[152 mm]

CUT PANELS TO ALLOW SPACE FOR

SUFFICIENT EXPANSION AND CONTRACTION.

SEE INSTALLATION GUIDE OR CONTACT

RULON TECHNICAL SUPPORT FOR MORE

INFORMATION.

1" [25 mm] L-ANGLE

(NOT BY RULON)

3'-0" [914 mm] O.C.

MAX. ATTACHED

TO CARRIER

#875 EXPANSION JOINT

L-BRACKET (NOT BY

RULON) ATTACHED

WITH SCREWS TO

EXPANSION JOINT

ENDURE CEILING STRIP

ENDURE CEILING STRIP

ENDURE #875 Expansion Joint

Detail

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000005

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 32: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

STRUTS AND #12-GA.

HANGER WIRE

(NOT BY RULON). SEE

DRAWING PXX00007

FOR INSTALLATION

DETAILS.

#880 ENDURE

CARRIER

4'-0" [1226 mm]

TYP.

3'-0" [914 mm] O.C.

MAX.

6" [152 mm] MAX.

AT TERMINATIONS

NOTE: CONTACT RULON

TECHNICAL DEPARTMENT

FOR HIGH WINDLOAD

APPLICATIONS

ENDURE Exterior Installation -

Spacing

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000006

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 33: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

2" [51 mm]

FIELD

MEASUREMENT

STRUCTURE

90°

NOTE:

CUT LEGS OF

CHANNEL AND BEND

TO PERMIT

ATTACHMENT TO

STRUCTURE AND

CARRIER.

90°

APPROPRIATE

FASTENERS

(NOT BY RULON)

STRUT NOT

BY RULON

1

1

2

"

[38 mm]

2

1

2

"

[64 mm]

20-GA.

CHANNEL STRUT

CROSS-SECTION,

TYPICAL

ENDURE Strut Detail - Exterior

Installation

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

PXX00007

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 34: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

ATTACHMENTS FOR

LATERAL STABILITY

ONLY

LIGHT FIXTURE

MUST BE

INDEPENDENTLY

SUPPORTED

ENDURE Recessed Can Light

Detail

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000008

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 35: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

NOTE:

CEILING CARRIER SUPPORTS

OMITTED FOR CLARITY

LIGHT FIXTURE MUST BE

INDEPENDENTLY SUPPORTED

USE SHORT PIECES OF

CARRIER TO BRIDGE

AROUND LIGHT ENDS

ENDURE

CEILING

LINEAR FIXTURE

(NOT BY RULON)

ENDURE with Linear Light Fixture

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000009

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUL/08/2015

Page 36: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

FIELD-NOTCH AND ATTACH

1" [25 mm] L-ANGLE

(NOT BY RULON)

SUSPEND ADDITIONAL

PIECES OF RULON

CARRIER AS NEEDED

PLAN VIEW

(ACCESS PANEL PARTIALLY OPEN)

2' [610 mm] X 2' [610 mm] ACCESS PANEL SHOWN

(SIZE VARIES PER PROJECT)

SEE HINGE DETAIL BELOW

SEE LATCH DETAIL BELOW

NOTE: RULON PERIMETER

TRIM CAN BE USED TO

CONCEAL "CORE" OF

MATERIAL

1" [25 mm] L-ANGLE ATTACHED TO ENDURE CARRIER

WITH MACHINE SCREWS AND NUTS (NOT BY RULON)

1

1

2" [38 mm] DOOR

HINGE, ATTACHED

TO L-ANGLE WITH

MACHINE SCREWS

AND NUTS

(NOT BY RULON)

REMOVE INTEGRAL

SPACER IN FIELD

WITH ROUTER

(ENDURE 900

ONLY)

LATCH DETAIL

(SHOWN CLOSED)

HINGE DETAIL

(SHOWN CLOSED)

ENDURE Access Panel Detail

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P9000010

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 37: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

#12-GAUGE WIRE

HANGERS (NOT BY RULON)

4' [1219 mm] O.C. ALONG

CARRIERS

#880 CARRIERS

3' [914 mm] O.C. MAX.

(POOL OR REC.

AREA 2' O.C. MAX.)

#860 SPACERS (NOT

REQUIRED WITH #900

SYSTEM)

#850 (SHOWN), #800

OR #900 STRIPS

ENDURE Ceiling Installation

Detail - Interior

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

P8500011

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]

JUN/23/2015

Page 38: RULON ENDURE 800 SERIES LINEAR SUSPENDED ENGINEERED ...€¦ · A. Suspension systems and components for ceilings, other than manufacturer's Endure Linear Suspended Engineered Polymer

SHIM UNDER STUDS WHERE

NECESSARY TO LEVEL THE CARRIERS

METAL STUDS

OR STRUCTURE

ATTACH #880 CARRIER TO METAL STUDS

USING SCREWS 3' [914 mm] ON CENTER

#880 CARRIER

#880 CARRIER

SHIM

METAL

STUD

ENDURE Direct Mount Detail

ISSUE DATE: PROJECT NUMBER:

REVISION DATE: DRAWING NUMBER:

PXX00012

PROJECT:

TITLE:

DRAWN BY:

CHECKED BY:

CAP

TR

World Commerce Center

2000 Ring Way Road

St. Augustine, FL 32092

Ph: 1-800-227-8566

904-584-1400

Fax: 904-584-1499

www.rulonco.com

[email protected]