rs-vs-c rail

5
COMPONENT SPECIFICATIONS 1 RBI Solar RS-VS | TS 2017 Length Height Width Weight Cross-Seconal Area Alloy Area Moment of Inera (lx) Area Moment of Inera (ly) RS-VS-C Rail Varies 2.360” 1.450” 0.666 lbs/LF 0.567 in 2 6063-T6 0.400 in 4 0.140 in 4 Length Height Width Weight Cross-Seconal Area Alloy Area Moment of Inera (lx) Area Moment of Inera (ly) RS-VS-C Splice Connector 7.680” 1.880” 1.070” 0.603 lbs 0.802 in 2 6063-T6 0.297 in 4 0.107 in 4 Length Height Width Weight Cross-Seconal Area Alloy Area Moment of Inera (lx) Area Moment of Inera (ly) RS-VS-R Rail Varies 1.970” 1.480” 0.547 lbs/LF 0.456 in 2 6063-T6 0.234 in 4 0.114 in 4 Length Height Width Weight Cross-Seconal Area Alloy Area Moment of Inera (lx) Area Moment of Inera (ly) RS-VS-R Splice Connector 7.680” 1.530” 1.090” 0.572 lbs 0.745 in 2 6063-T6 0.206 in 4 0.094 in 4 RBI Solar Versatile Roof Mount Solution | RS-VS

Upload: others

Post on 13-Jun-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RS-VS-C Rail

C O M P O N E N T S P E C I F I C A T I O N S

1RBI Solar RS-VS | TS 2017

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

RS-VS-C Rail

Varies 2.360”1.450”0.666 lbs/LF 0.567 in2

6063-T6 0.400 in4

0.140 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

RS-VS-C Splice Connector

7.680” 1.880”1.070”0.603 lbs 0.802 in2

6063-T6 0.297 in4

0.107 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

RS-VS-R Rail

Varies 1.970”1.480”0.547 lbs/LF 0.456 in2

6063-T6 0.234 in4

0.114 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

RS-VS-R Splice Connector

7.680” 1.530”1.090”0.572 lbs 0.745 in2

6063-T6 0.206 in4

0.094 in4

RBI Solar Versatile Roof Mount Solution | RS-VS

Page 2: RS-VS-C Rail

2RBI Solar RS-VS | TS 2017

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

RBI Solar Versatile Roof Mount Solution | RS-VS

C O M P O N E N T S P E C I F I C A T I O N SC O M P O N E N T S P E C I F I C A T I O N S ( C O N T I N U E D )

End Clamp

RS-VS GF L-foot

RS-VS L-foot

1.380” 1.540” 0.101 lbs 6005-T5

2.000” 3.350” 2.000” 0.287 lbs 1.464 in2 6063-T6 1.773 in4 0.283 in4

2.000” 3.350” 2.000” 0.287 lbs 1.467 in2 6063-T6 1.776 in4 0.284 in4

• Length• Width• Weight• Alloy

5.906” 1.811” 0.945” 0.489 lbs 0.489 in2

6005-T5 0.172 in4

0.024 in4

IB Splice Connector

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Page 3: RS-VS-C Rail

3RBI Solar RS-VS | TS 2017

RBI Solar Versatile Roof Mount Solution | RS-VS

C O M P O N E N T S P E C I F I C A T I O N SC O M P O N E N T S P E C I F I C A T I O N S ( C O N T I N U E D )

• Length• Width• Weight• Alloy

Mid Clamp

1.500” 0.750” 0.115 lbs 6005-T5

• Length• Width• Weight• Alloy

IB Mid Clamp

1.500” 0.750” 0.165 lbs6005-T5

• Length• Width• Height• Weight• Alloy

WEEB-Lug-8.0

0.866” 1.700” 0.945” 0.138 lbs 304SS, Coated Copper

• Length• Width• Height• Weight• Alloy

WEEB-CCR 2

1.588” 1.496” 0.223”0.008 lbs304SS

• Length• Width• Height• Weight• Alloy

Module Jumper (DynoBond)

7.500” 0.610”0.245” 0.21 lbs 304SS, Coated Copper

Page 4: RS-VS-C Rail

RBI Solar Versatile Roof Mount Solution | RS-VS

C O M P O N E N T S P E C I F I C A T I O N SC O M P O N E N T S P E C I F I C A T I O N S ( C O N T I N U E D )

4RBI Solar RS-VS | TS 2017

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Large Tilt Leg, Portrait, 10°

1.500” 12.164” 2.000” 0.553 lbs 3.505 in2 6063-T6 54.406 in4 0.510 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Small Tilt Leg, Portrait, 10°

1.500”3.700” 2.000” 0.553 lbs 1.506 in2 6063-T6 2.287 in4 0.312 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Large Tilt Leg, Portrait, 5°

1.500” 7.022” 2.000” 0.320 lbs 2.275 in2 6063-T612.193 in4

0.416 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Small Tilt Leg, Portrait, 5°

1.500” 2.800” 2.000”0.170 lbs1.267 in26063-T61.215 in40.229 in4

Page 5: RS-VS-C Rail

5RBI Solar RS-VS | TS 2017

RBI Solar Versatile Roof Mount Solution | RS-VS

C O M P O N E N T S P E C I F I C A T I O N SC O M P O N E N T S P E C I F I C A T I O N S ( C O N T I N U E D )

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Large Tilt Leg, Landscape, 10°

1.500”8.100”2.000”0.423 lbs2.954 in2

6063-T623.511 in4

1.107 in4

• Length• Height• Width• Weight• Cross-Sectional Area• Alloy• Area Moment of Inertia (lx)• Area Moment of Inertia (ly)

Small Tilt Leg, Landscape, 10°

1.500” 1.369” 3.730” 0.170 lbs1.239 in2

6063-T60.080 in4

1.080 in4