rp / rpc series - the home depot · pdf filein020 rev t 0217 3 saber way, ward hill, ma 01835...

8
IN020 Rev T 0217 1 3 Saber Way, Ward Hill, MA 01835 | radonaway.com RP / RPc Series Installation Instructions c

Upload: dinhanh

Post on 05-Feb-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 13 Saber Way, Ward Hill, MA 01835 | radonaway.com

RP / RPc SeriesInstallation Instructions

c

Page 2: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 23 Saber Way, Ward Hill, MA 01835 | radonaway.com

Fan Installation & Operating InstructionsPlease Read and Save These Instructions.

DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.

1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. See RadonAway.com/vapor-intrusion.

2. NOTE: Fan is suitable for use with solid state speed controls; however, use of speed controls is not generally recommended.

2. WARNING! Check voltage at the fan to insure it corresponds with nameplate.

3. WARNING! equipment. Check for possible backdraft conditions on all combustion devices after installation.

4. NOTICE! There are no user serviceable parts located inside the fan unit. Do NOT attempt to open. Return unit to the factory for service.

5. WARNING! Do not leave fan unit installed on system piping without electrical power for more than 48 hours. Fan failure could result from this non-operational storage.

6. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

c) Installati

d) S equipment to prevent backdrafting. Follow the heating equipment manufacturers’ guidelines and safety standards such as those published by any National Fire Protection Association, and the American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the local code authorities.

e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.

f) Ducted fans must always be vented to outdoors.

g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.

Page 3: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 33 Saber Way, Ward Hill, MA 01835 | radonaway.com

1.0 SYSTEM DESIGN CONSIDERATIONS

1.1 INTRODUCTION

The purpose of these instructions is to provide additional guidance for the most effective use of an RP / RPC Series Fans. These instructions should be considered supplemental to EPA/radon industry standard practices, state and local

e precedence over these instructions.

1.2 FAN SEALINGThe RP / RPc Series Fans are factory sealed; no additional caulk or other materials are required to inhibit air leakage.

1.3 ENVIRONMENTALSThe RP / RPc Series Fans are designed to perform year-round in all but the harshest climates without additional concern for temperature or weather. For installations in an area of severe cold weather, please contact RadonAway for assistance. When not in operation, the fan should be stored in an area where the temperature is never less than 32 degrees F or more than 100 degrees F. 1.4 ACOUSTICSThe RP / RPc Series Fans, when installed properly, operate with little or no noticeable noise to the building occupants. The velocity of the outgoing air should be considered in the overall system design. In some cases the “rushing” sound of the outlet air may be disturbing. In these instances, the use of a R

[To ensure quiet operation of inline and remote fans, each fan shall be installed using sound attenuation techniques appropriate for the

supply grille(s) and the fan(s). RP / RPc Series Fans are not suitable for kitchen range hood remote ventilation applications.]

1.5 GROUND WATERIn the event that a temporary high water table results in water at or above slab level, water may be drawn into the

and off as the internal temperature rises above the thermal cutoff and falls upon shutoff. Should this condition arise, it is recommended that the fan be turned off until the water recedes, allowing for return to normal operation.

1.6 SLAB COVERAGEThe RP / RPc Series Fans can provide coverage up to 2000+ sq. ft. per slab penetration. This will primarily depend on the sub-slab material in any particular installation. In general, the tighter the material, the smaller the area covered per penetration. Appropriate selection of the RP / RPc Series Fan best suited for the sub-slab material can improve the slab coverage. The RP140/140c and RP145/145c are best suited for general purpose use. The RP260/260c can be

gallons in size) be created below the slab at each suction hole.

Fan Installation & Operating Instructions Fan Series

RP140 | P/N 28460 RP140c | P/N 23029-1 RP145 | P/N 28461 RP145c | P/N 23030-1 RP260 | P/N 28462 RP260c | P/N 23032-1 RP265 | P/N 28463 RP265c | P/N 23033-1 RP380 | P/N 28464

Page 4: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 43 Saber Way, Ward Hill, MA 01835 | radonaway.com

1.7 CONDENSATION & DRAINAGECondensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside. The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RP / RPc Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage through the fan. Avoid mounting the fan in any orientation that will allow water to accumulate inside the fan housing. The RP / RPc Series Fans are NOT suitable for underground burial.

For RP / RPc Series Fan piping, the following table provides the minimum recommended pipe diameter and pitch under several system conditions.

PipeDiameter

Minimum Rise per Ft of Run*@25 CFM @50 CFM @100 CFM @200 CFM @300 CFM

6” - 3/16 1/4 3/8 3/4

4” 1/8 1/4 3/8 2 3/8 -

3” 1/4 3/8 1 1/2 - -

1.8 SYSTEM MONITOR & LABELA System Monitor, such as a manometer (P/N 50017) or audible alarm (P/N 28001-2, 28001-4 or 28421), should be provided and is required to notify the occupants of a fan system malfunction. A System Label (provided with Manometer P/N 50017) with instructions for contacting the installing contractor for service and identifying the necessity for regular radon tests to be conducted by the building occupants must be conspicuously placed in a location where the occupants frequent and can see the label.

1.9 VENTILATION

prevent the warm bathroom air, for example, from forming condensation in the ducting where it is exposed to colder attic air. The outlet of the fan should always be ducted to the outside. Avoid venting the outlet of the fan directly into an attic area. The excess moisture from the bathroom can cause damage to building structure and any items stored in the attic. Multiple venting points may be connected together using a “

each grille should be equal in order to minimize noise and resistance. Straight smooth runs of rigid metal ducting will present the least resistance and maximize system performance. The Equivalent Length of Rigid Metal Ducting

Flexible ducting, if used, must always be as close to being fully extended as possible. Formed rigid metal duct elbows will present the least resistance and maximize system performance; recommended bend radius of elbow is at least 1.5 x duct diameter.

RP / RPc Series fans are not suitable for kitchen range hood remote ventilation applications. For quietest performance, the fan should be mounted farther away from the inlet duct, near the outside vent. A minimum distance of 8 feet is recommended between the fan or T/Y of a multi-intake system and intake grille(s).

and minimizing possible condensation and icing within the system while the fan is not operating. Backdraft dampers are highly recommended at each intake grille for bathroom ventilation in all cold climate installations. Installation instructions are included with Spruce backdraft dampers.

Page 5: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 53 Saber Way, Ward Hill, MA 01835 | radonaway.com

1.10 ELECTRICAL WIRINGThe RP / RPc Series Fans operate on standard 120V, 60Hz AC. All wiring must be performed in accordance with National Fire Protection (NFPA) National Electrical Code, Standard #70, current edition, for all commercial and industrial work, and state and local building codes. All wiring must be perelectrician. Outdoor installations require the use of a UL Listed watertight conduit. Ensure that all exterior electrical boxes are outdoor rated and properly sealed to prevent water penetration into the box. A means, such as a weep hole, is recommended to drain the box.

1.11 SPEED CONTROLSThe RP / RPc Series Fans are rated for use with electronic speed controls; however, speed controls are generally not recommended. If used, the recommended speed control is Pass & Seymour Solid State Speed Control.

2.0 INSTALLATION

The RP / RPc Series Fans can be mounted indoors or outdoors. (It is suggested that EPA and radon mitigation standards recommendations be followed in choosing the fan location.) The RP / RPc Series Fans may be mounted directly on the system piping or fastened to a supporting structure by means of an optional mounting bracket.

For the ENERGY STAR Labeled RP140 / RP140c , the ducting from the fan to the outside of the building has a strong effect on noise and fan energy use. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated

2.1 MOUNTINGMount the RP / RPc Series Fan vertically with outlet up. Ensure the unit is plumb and level. When mounting directly on the system piping assure that the fan does not contact any building surface to avoid vibration noise.

2.2 MOUNTING BRACKET (optional)The RP / RPc Series Fan may be optionally secured with the RadonAway mounting bracket (P/N 25007 or 25033 for RP380 only). Foam or rubber grommets may also be used between the bracket and mounting surface for vibration isolation.

Page 6: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 63 Saber Way, Ward Hill, MA 01835 | radonaway.com

2.3 SYSTEM PIPING

disconnect for servicing the unit and for vibration isolation. As the fan is typically outside of the building thermal boundary and is venting to the outside, installation of insulation around the fan is not required.

2.4 ELECTRICAL CONNECTIONConnect wiring with wire nuts provided, observing proper connections (See Section 1.10). Note that the fan is not intended for connection to rigid metal conduit.

Fan Wire ConnectionGreen GroundBlack AC HotWhite AC Common

2.5 VENT MUFFLER (optional)

normally installed at the end of the vent pipe.

2.6 OPERATION CHECKS & ANNUAL SYSTEM MAINTENANCE

______ Verify all connections are tight and leak-free.

______ Ensure the RP / RPc Series Fan and all ducting are secure and vibration-free.

______ Verify system vacuum pressure with manometer. Ensure vacuum pressure is within normal operating range and less than the maximum recommended operating pressure. (Based on sea-level operation, at higher altitudes reduce by about 4% per 1000 feet) (Further reduce Maximum Operating Pressure by 10% for High Temperature environments.)

______ Verify Radon levels by testing to EPA Protocol and applicable testing standards.

Page 7: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 73 Saber Way, Ward Hill, MA 01835 | radonaway.com

Typical CFM Vs. Static Pressure “WC

0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”

RP140/140c 135 103 70 14 - - - -

RP145/145c 166 146 126 104 82 61 41 21 3

RP260/260c 251 200 157 117 70 26 - - -

RP265/265c 334 291 247 210 176 142 116 87 52

RP380/380c 497 401 353 281 220 176 130 80 38

Model Size Weight Inlet/Outlet L.2

RP140/140c 8.5”H x 9.7” Dia. 5.5 lbs 4.5”OD (4.0” PVC Sched 40 size compatible) 25

RP145/145c 8.5”H x 9.7” Dia. 5.5 lbs 4,5” OD 15

RP260/260c 8.6”H x 11.75” Dia. 5.5 lbs 6.0” OD 48

RP265/265c 8.6”H x 11.75” Dia. 6.5 lbs 6.0” OD 30

RP380/380c 10.53”H x 13.41” Dia. 11.5 lbs 8.0” OD 57

ModelPower Consumption

120VAC, 60Hz, 1.5 Amp MaximumMaximum Recommended Operation Pressure*

(Sea Level Operation)**

RP140/140c 15 - 21 watts 0.7” WC

RP145/145c 41 - 72 watts 1.7” WC

RP260/260c 47 - 65 watts 1.3” WC

RP265/265c 91 - 129 watts 2.2” WC

RP380/380c 95 - 152 watts 2.0” WC

L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).

Recommended Ducting: RP/RPc Series Fans (excluding RP380/380c), 3” or 4” Schedule 20/40 PVC Pipe;

RP380/RP380c, 6” Schedule 20/40 PVC Pipe

PVC Pipe Mounting: If used for Ventilation, use 4”, 6” or 8” Rigid or Flexible Ducting.

Mount on the duct pipe or with optional mounting bracket.

Storage Temperature Range: 32-100 degrees F

Thermal Cutout:

Continuous Duty

Class F Insulation (RP140/RP140c Class B)

Thermally Protected Manual Reset

3000 RPM

Rated for Indoor or Outdoor Use

*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.

The following chart shows fan preformance for the RP / RPc Series Fans:

RP140/140c 130oC (266oF)

RP145/145c 150oC (302oF)

RP260/260c 150oC (302oF)

RP265/265c 150oC (302oF)

RP380 150oC (302oF))

Page 8: RP / RPc Series - The Home Depot · PDF fileIN020 Rev T 0217 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 1 RP / RPc Series Installation Instructions c

IN020 Rev T 0217 83 Saber Way, Ward Hill, MA 01835 | radonaway.com

IMPORTANT INSTRUCTIONS TO INSTALLERInspect the RadonAway® RP/RPc, GP/GPc, XR/XRc, XP/XPc, XR and SF Series Fan for shipping damage within 15

days of receipt. Notify RadonAway of any damages immediately. RadonAway is not responsible for damages incurred

There are no user serviceable parts inside the fan. Do not attempt to open the housing. Return unit to factory for

service.

Install the RP/RPc, GP/GPc, XP/XPc, and XR SF Series Fan in accordance with all EPA, ANSI/AARST standard

practices, and state and local building codes and regulations.

Provide a copy of this instruction or comparable radon system and testing information to the building occupants

after completing system installation.

WarrantyRadonAway® warrants that the RP/RPc, GP/GPc (excluding GP500), XP/XPc, XR, SF Series Fan (the “Fan”) will be free from defects in materials and workmanship for a period of 12 months from the date of purchase or 18 months from the date of manufacture, whichever is sooner (the “Warranty Term”).

RadonAway® will replace any fan which fails due to defects in materials or workmanship during the Warranty Term. This Warranty is contingent on installation of the Fan in accordance with the instructions provided. This Warranty does not apply where any repairs or alterations have been made or attempted by others, or if the unit has been abused or misused. Warranty does not cover damage in shipment unless the damage is due to the negligence of RadonAway®.

The Fan must be returned (at Owner’s cost) to the RadonAway® factory. Any Fan returned to the factory will be discarded unless the

under this warranty. Proof of purchase must be supplied upon request for service under this Warranty.

5-YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION.

RadonAway® will extend the Warranty Term of the fan to 60 months (5 years) from date of purchase or 66 months from date of manufacture, whichever is sooner, provided that the fan is installed by a professional radon mitigation contractor. Proof of purchase and/or proof of professional installation may be required for service under this warranty. No extended warranty is offered outside the Continental United States and Canada beyond the standard 12 months from the date of purchase or 18 months from the date of manufacture, whichever is sooner.

RadonAway® is not responsible for installation, removal or delivery costs associated with this Warranty.

LIMITATION OF WARRANTY

EXCEPT AS STATED ABOVE, THE RP/RPc, GP/GPc (excluding GP500), XP/XPc, XR, SF SERIES FANS ARE PROVIDED WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN OR THE PERFORMANCE THEREOF. RADONAWAY’S AGGREGATE LIABILITY HEREUNDER SHALL NOT IN ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT. THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH RADONAWAY’S WARRANTY AS PROVIDED ABOVE.

For service under this Warranty, contact RadonAway for a Return Material Authorization (RMA) number and shipping information. No returns can be accepted without an RMA. If factory return is required, the customer assumes all shipping costs, including insurance, to and from factory.

RadonAway® 3 Saber WayWard Hill, MA 01835 USA TEL (978) 521-3703

FAX (978) 521-3964Email to: [email protected]

Record the following information for your records:

Serial Number: Purchase Date: