rp ex, rq ex fans - proidea€¦ · rp ex, rq ex fans fans rp fans rq fans ro fans rf fans rph fans...

16
108 RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers ... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers CHV Direct coolers CHF Heat exchangers HRV Accessories ... Technical information Materials The external casing and connecting flanges of RP Ex and RQ Ex fans are made of galvanized sheet steel (Zn 275 g/m2), respectively stainless steel. Impeller blades are made of galvanized sheet steel, diffusers are made of copper, and the motors' casings are made of alumini- um alloys. The internal structure of the motors consists of steel, copper and plastic parts. All materials are ca- refully verified and checked so they ensure long service life and reliability of the fans. Impellers Impellers of RP Ex and RQ Ex fans are equipped with forward curved blades. After connecting the motor to the wiring, the impeller's direction of rotation must be checked. The fans' impellers must always rotate to the left, i.e. counter clockwise (looking through the inspec- tion opening on the motor cup). The inspection opening on the motor cup is sealed with a rubber plug. Impellers along with the motor are perfectly statically and dynami- cally balanced. Motors Compact three-phase asynchronous motors with an external rotor and a resistance armature of appropriate output and speed, and approved in accordance with the 94/9/ES (ATEX) Directive are used as drives, see figu- re #2. The motors are situated inside the impeller, and during operation are optimally cooled by the flowing air. The motor's high quality enclosed ball bearings with permanent lubricant filling enable the fans to reach a service life of more than 40,000 opera- ting hours without main- tenance. The motor elect- rical protection degree is IP 44, insulation class F. The motor windings are impregnated to provide Applications of Ex Fans Ex versions of fully controlled, low-pressure RP and RQ radial Fans can be universally used for complex air-conditioning, from simple venting installations to so- phisticated air-handling systems. Thanks to their special design, which in accordance with the EN 13463-1 and 13463-5 standards prevents mechanically generated sparks, and the "e" version of the motor in accordance with the EN 50014 standard, these fans are intended for applications in explosion hazardous areas. Operating Conditions, Position These fans are designed for indoor and outdoor appli- cations, and to transport air without solid, fibrous, sticky or aggressive impurities. The transported air must be free of corrosive chemicals or chemicals aggressive to zinc, copper and/or aluminium. The allowed temperatu- res of the transported air ranges from -20 °C up to +40 °C. These fans are designed for use in Zone 1 in reference to the classification of explosion hazardous areas in accordance with the EN 60079-10 standard. Explosion-proof RP and RQ Ex fans, secure version "e", belong according to EN 60079-0 to Group II and are la- belled with the II 2G Exe II TX marks. The fans themselves are labelled with the II 2G c IIB+H 2 TX marks proving their explosion- -proof design. The fans can work in any position. When positioned under the ceiling, it is advisable to situate the RP Ex fan with its cup directed downwards to ease access to the motor terminal box. However, if transported air is oversaturated with moisture or if the risk of intensive steam condensation inside the fan exists, it is advisable to situate the fan's cup upwards. We recommend adding a 1 to 1.5 m long piece of strai- ght duct to the fan's outlet to reduce pressure losses in the assembly. RQ Ex fans are mostly installed in the horizontal posi- tion of the motor shaft rotation (however, this is not a condition of use). The square sidewalls of the fan serve also as legs to fix the fan onto the base using anchor bolts. The fan can be positioned in four positions turned by 90°. Dimensional Range RP Ex fans are manufactured in a range of six sizes according to the A x B dimensions of the connecting flange. RQ Ex fans are manufactured in a range of three sizes according to the impeller's diameter, see figure # 1. The standard dimensional and performance range of explosion-proof fans enables the designers to optimize all parameters for air flow up to 5,800 m 3 per hour. (1 Group II. - Electrical equipment for explosion hazardous areas (except underground mines with presence of methane). RQ Ex Fans 400-200 500-250 40-20 50-25 600-300 60-30 600-350 60-35 700-400 70-40 80-50 800-500 A x B [mm] RP Ex Fans 200 220 280 Diameter [mm] 20 22 28 Figure 1 - Dimensional Range Figure 2

Upload: others

Post on 06-Dec-2019

50 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

108

RP Ex, RQ Ex FansFa

ns

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

Technical information

MaterialsThe external casing and connecting flanges of RP Ex and RQ Ex fans are made of galvanized sheet steel (Zn 275 g/m2), respectively stainless steel. Impeller blades are made of galvanized sheet steel, diffusers are made of copper, and the motors' casings are made of alumini-um alloys. The internal structure of the motors consists of steel, copper and plastic parts. All materials are ca-refully verified and checked so they ensure long service life and reliability of the fans.

ImpellersImpellers of RP Ex and RQ Ex fans are equipped with forward curved blades. After connecting the motor to the wiring, the impeller's direction of rotation must be checked. The fans' impellers must always rotate to the left, i.e. counter clockwise (looking through the inspec-tion opening on the motor cup). The inspection opening on the motor cup is sealed with a rubber plug. Impellers along with the motor are perfectly statically and dynami-cally balanced.

MotorsCompact three-phase asynchronous motors with an external rotor and a resistance armature of appropriate output and speed, and approved in accordance with the 94/9/ES (ATEX) Directive are used as drives, see figu-re #2. The motors are situated inside the impeller, and during operation are optimally cooled by the flowing air.

The motor's high quality enclosed ball bearings with permanent lubricant filling enable the fans to reach a service life of more than 40,000 opera-ting hours without main-tenance. The motor elect-rical protection degree is IP 44, insulation class F. The motor windings are impregnated to provide

Applications of Ex FansEx versions of fully controlled, low-pressure RP and RQ radial Fans can be universally used for complex air-conditioning, from simple venting installations to so-phisticated air-handling systems. Thanks to their special design, which in accordance with the EN 13463-1 and 13463-5 standards prevents mechanically generated sparks, and the "e" version of the motor in accordance with the EN 50014 standard, these fans are intended for applications in explosion hazardous areas.

Operating Conditions, PositionThese fans are designed for indoor and outdoor appli-cations, and to transport air without solid, fibrous, sticky or aggressive impurities. The transported air must be free of corrosive chemicals or chemicals aggressive to zinc, copper and/or aluminium. The allowed temperatu-res of the transported air ranges from -20 °C up to +40 °C.These fans are designed for use in Zone 1 in reference to the classification of explosion hazardous areas in accordance with the EN 60079-10 standard. Explosion-proof RP and RQ Ex fans, secure version "e", belong according to EN 60079-0 to Group II and are la-belled with the II 2G Exe II TX marks.The fans themselves are labelled with the

II 2G c IIB+H2 TX marks proving their explosion--proof design.The fans can work in any position.When positioned under the ceiling, it is advisable to situate the RP Ex fan with its cup directed downwards to ease access to the motor terminal box. However, if transported air is oversaturated with moisture or if the risk of intensive steam condensation inside the fan exists, it is advisable to situate the fan's cup upwards. We recommend adding a 1 to 1.5 m long piece of strai-ght duct to the fan's outlet to reduce pressure losses in the assembly.RQ Ex fans are mostly installed in the horizontal posi-tion of the motor shaft rotation (however, this is not a condition of use). The square sidewalls of the fan serve also as legs to fix the fan onto the base using anchor bolts. The fan can be positioned in four positions turned by 90°.

Dimensional RangeRP Ex fans are manufactured in a range of six sizes according to the A x B dimensions of the connecting flange. RQ Ex fans are manufactured in a range of three sizes according to the impeller's diameter, see figure # 1. The standard dimensional and performance range of explosion-proof fans enables the designers to optimize all parameters for air flow up to 5,800 m3 per hour.

(1 Group II. - Electrical equipment for explosion hazardous areas (except underground mines with presence of methane).

RQ Ex Fans

400-200

500-250

40-20

50-25

600-300 60-30

600-350 60-35

700-400 70-40

80-50800-500

A x B [mm]

RP Ex Fans

200

220

280

Diameter [mm]

20

22

28

Figure 1 - Dimensional Range

Figure 2

Page 2: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

109

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

them with additional protection against moisture. The motors feature relatively low build-up current.

Electrical EquipmentThe fan's wiring is terminated in a special explosion--proof terminal box of IP 66 protection degree. For wi-ring diagrams of motors, refer to the section "Wiring".Attention! The motors must not be delta connected. They must always be star connected.

Motor ProtectionAs standard, permanent monitoring of the internal mo-tor temperature is used in all motors. The temperature inside the motor is read by temperature-sensitive sen-sors (thermistors) situated in the motor winding (2. The thermistors must be connected to the trip relay which, after reaching a temperature of 130 °C, disconnects the protective contactor circuit. This system protects the motor against unfavourable operating conditions, e.g. overloading due to phase failure, forced motor braking,

current protection circuit breakdown or excessive temperature of the trans-ported air. This thermal protection is comprehen-sive and reliable providing it is correctly connected. RP Ex and RQ Ex fans have been approved by Notified Body ES 1026, Fyzikálně-technický ústav Ostrava-Radvanice, to be operated only in conne-ction with the prescribed

thermal protection (refer to the wiring diagrams in the chapter "Wiring"). Therefore, it is forbidden to protect the fan motors by conventional thermal protection ensured by the motor overcurrent protective elements!

Speed ControlGenerally, several types of control can be used with fans; however, voltage control is the most suitable for Vento fans. The fan output can be fully controlled by changing the speed. The fan's speed is changed de-pending on the voltage at the motor terminals. RP Ex and RQ Ex fans can be steplessly controlled providing the change in voltage is stepless. In practice, stage voltage controllers are usually used.

Five-Stage Voltage ControlThe voltage control of Vento fans is the most suitable, technically as well as operationally. There is no interfe-rence, humming, squeaking or vibration of the motor;

furthermore, voltage controlled motors feature lower warming.TRN and TRR voltage controllers can control the fan output in five stages in 20 % steps, with which five pre-ssure-airflow relation curves in the working characteris-tics of each fan comport. Ex fan motors can be operated within a range from 25% to 100% of the rated voltage. Refer to table # 1 showing the correlation between the input voltage and selected stage of the controller.Ex fans are delivered only with three-phase motors. Three-phase TRN or TRRD controllers are used to con-trol speed, respectively output.Four types of TRN controllers, TRN 2D, TRN 4D, TRN 7N, and TRN 9N, are manufactured according to their

(2 The motors of RP and RQ fans intended for non-explosive environment are equipped with a thermo-contact which when opening can cause sparking inside the motor (this is impermissible in Zone 1 areas). Therefore, Ex-type fans are provided with PTC thermistors, which must be connected to the thermistor relay. As far as operation is concerned, the system of thermistors and tripping device comports with the system of thermo-contacts used for RP and RQ fans intended for non-explosive environment.

Technical information

Table 1 - input voltage and controller's stage

current ratings. The option of remote control (by manual switch ORe5 or by an OCm controller in the control unit, respectively by automatic switching of the five stages of the OXe controller based on an external control signal of 0 - 10 V) is a significant feature of this product line. TRN controllers are equipped with integrated fan pro-tection, which is activated by connecting to the thermis-tor relay.Four types of simpler TRRD controllers, TRRD 2, TRRD 4, TRRD 7 and TRRD 9, are also manufactured. These controllers cannot be remotely controlled (therefore, they must be situated within reach of the operator), and they do not contain any fan protection (this must be pro-vided by another device).

AccessoriesRP Ex and RQ Ex fans are part of the wide range of Vento modular venting and air-handling system compo-nents. Any air-handling set-up, from simple venting to sophisticated comfortable air-conditioning, can be crea-ted by selecting suitable elements. When designing a particular air-handling device, it is necessary to keep in mind the environment for which the air-handling device is intended.For example, all the protection elements (thermistor relay, TRN, or WebClima) must be situated outside explosion hazardous areas.

Třífázovýelektromotor

Křivka charakteristiky – stupeň regulátoru

Figure 3 - Thermistor

3-phase fan motor

Voltage (V)

Curve characteristics – controller's stage

Page 3: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

110

RP Ex, RQ Ex FansFa

ns

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

Vybavovač ochrany + ochrana

Fan Description and DesignationThe type designation of RP Ex and RQ Ex explosion--prove fans in projects and orders is defined by the key shown in figure # 4.RQ 28-4D Ex or RP 60-30/28-4D Ex specifies the type of fan, impeller and motor.

Operating CharacteristicsOutput characteristics of RP Ex and RQ Ex fans are measured in the most modern testing laboratory for aerodynamic and electrical measurements of fans and pressure losses of passive elements within the Czech Republic.A table showing the most important values is situated next to each fan's characteristic in the "Data Section" of the catalogue (see table # 2). These values are also listed on the fan's rating plate.The meaning of individual lines is as follows:

Explosion-proof Ex versionMotor D - three-phase motorNumber of motor's poles 4 - four-pole 6 - six-poleImpeller diameter (cm)Flange connection B dimension (cm)Flange connection A dimension (cm)Fan casing

RP 60 - 30 / 28 - 4 D Ex

RQ 28 - 4 D Ex

Technical information

Figure 4 – Type designation key of Ex fans

Table 2

RP 70-40/35-6D Ex

1 - Power supply voltage2 - Maximum power input of the motor at working point 5c of the fan characteristics3 - Maximum current at nominal voltage at working point 5c of the fan characteristics4 - Mean speed, rounded to tens, measured at working point 5b of the fan characteristics6 - Maximum permissible transported air temperature7 - Maximum air flow rate at working point 5c of the fan characteristics8 - Maximum total pressure between points 5a - 5c of the fan characteristics9 - Minimum permissible static pressure at point 5c of the fan characteristics10 - Total weight of the fan11 - Recommended fan output controller12 - Compulsory protection tripping device + prescribed protection

µ

1 –2 –3 –4 –5 –6 –7 –8 –9 –

10 –11 –12 –

Page 4: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

111

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

Table 3 - RP Ex Fan DimensionsDimensions, Weights and Performance of RP EX FansFor important dimensions of RP Ex fans, refer to figure # 5 and table # 3 & # 4.

Vmax. – maximum air flow rate at minimum permissible pressure loss∆pt max. – maximum total pressure of the fan is the maximum sum of ∆ps and ∆pd (∆ps + ∆pd) max. ∆ps min. – minimum allowed static pressure (i.e. pressure loss of connected duct) indicates the lowest value to which the fan must be throttled (at nominal voltage at working point 5c) so not to be overloaded and thus activating motor protectionn – fan speed measured at the highest efficiency working point (5b), rounded to tensU – nominal power supply voltage of the motor without control (all values in the table are related to this voltage)Pmax. – maximum electrical input of the motor at maximum loading, i.e. at air flow Vmax.

I max. – maximum phase current at voltage U and maximum allowed loading, i.e. at air flow Vmax at working point 5c (this value must be checked and the measured current must be written down on the guarantee card)t max. – maximum permissible transported air temperature at air flow Vmax.

controll. – prescribed fan output voltage controllerm* – weight of the fan (±10%)

Fan parameters

Figure 5 - RP Ex fan dimensional diagram

Table 4 - RP Ex fan basic parameters and nominal values

RP 40-20/20-4D Ex RP 50-25/22-4D Ex RP 60-30/28-4D Ex RP 60-35/31-4D Ex RP 70-40/35-6D Ex RP 80-50/40-6D Ex

Page 5: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

112

RP Ex, RQ Ex Fans

V – air-flow (m3/h)

V – air-flow (m3/h)

∆pt –

tota

l pre

sure

(Pa)

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Inlet Outlet Surrounding

Inlet Outlet Surrounding

Point 5b 5b 5b

Point 5b 5b 5b

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

RP 40-20/20-4D Ex

RP 50-25/22-4D Ex

µ

µ

Forbidden Area

Page 6: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

113

RP Ex, RQ Ex Fans

V – air-flow (m3/h)

∆pt –

tota

l pre

sure

(Pa)

∆pt –

tota

l pre

sure

(Pa)

V – air-flow (m3/h)

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Inlet Outlet Surrounding

Inlet Outlet Surrounding

Point 5b 5b 5b

Point 5b 5b 5b

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

RP 60-30/28-4D Ex

RP 60-35/31-4D Ex

µ

µ

Forbidden Area

Page 7: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

114

RP Ex, RQ Ex Fans

V – air-flow (m3/h)

V – air-flow (m3/h)

∆pt –

tota

l pre

sure

(Pa)

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Inlet Outlet Surrounding

Inlet Outlet Surrounding

Point 5b 5b 5b

Point 5b 5b 5b

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

RP 70-40/35-6D Ex

RP 80-50/40-6D Ex

µ

µ

Forbidden Area

Page 8: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

115

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

Dimensions, Weights and PerformanceFor important dimensions of RQ Ex fans, refer to Figure # 6 and Table # 4 & # 5.

∆∆

Parametry ventilátorů

Table 4 - RQ Ex types and dimensions

Table 5 – RQ Ex fan basic parameters and nominal values

Figure 6 – control drawing of RQ Ex fan

Vmax. – maximum air flow rate at minimum permissible pressure loss∆pt max. – maximum total pressure of the fan is the maximum sum of ∆ps and ∆pd (∆ps + ∆pd) max. ∆ps min. – minimum allowed static pressure (i.e. pressure loss of connected duct) indicates the lowest value to which the fan must be throttled (at nominal voltage at working point 5c) so not to be overloaded and thus activating motor protectionn – fan speed measured at the highest efficiency working point (5b), rounded to tensU – nominal power supply voltage of the motor without control (all values in the table are related to this voltage)Pmax. – maximum electrical input of the motor at maximum loading, i.e. at air flow Vmax.

I max. – maximum phase current at voltage U and maximum allowed loading, i.e. at air flow Vmax at working point 5c (this value must be checked and the measured current must be written down on the guarantee card)t max. – maximum permissible transported air temperature at air flow Vmax.

control. – prescribed fan output voltage controllerm* – weight of the fan (±10%)

RQ 20-4D ExRQ 22-4D ExRQ 28-4D Ex

Page 9: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

116

RP Ex, RQ Ex Fans

V – air-flow (m3/h)

V – air-flow (m3/h)

∆pt –

tota

l pre

sure

(Pa)

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Inlet Outlet Surrounding

Inlet Outlet Surrounding

Point 5b 5b 5b

Point 5b 5b 5b

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

RQ 20-4D Ex

RQ 22-4D Ex

Forbidden Area

µ

µ

Page 10: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

117

RP Ex, RQ Ex Fans

V – air-flow (m3/h)

∆pt –

tota

l pre

sure

(Pa)

∆pt –

tota

l pre

sure

(Pa)

V – air-flow (m3/h)

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Total sound power level LWA [dB(A)]

Sound power levels LWAokt [dB(A)]

Inlet Outlet Surrounding

Inlet Outlet Surrounding

Point 5b 5b 5b

Point 5b 5b 5b

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Parameters in selected working points

VoltageCurrentElectric inputSpeedAir flow rateStatic pressureTotal pressure

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

RQ 28-4D Ex

Thermistor Protection of Ex FansThe temperature inside the motors of all RP Ex and RQ Ex fans is permanently read by temperature sensitive sensors (PTC thermistors) situated in the motor win-ding. The thermistors must be connected to the thermis-tor relay, which disconnects the protective circuit of the STD or TRN controllers. At a maximum, two fans can be connected to the thermistor relay, and they must be connected in series. It necessary to be aware of the fact that this type of combined connection will cause both fans to be stopped even if only one of the motors fails.

STD TRN

controller or

protective relay

During failure (off) state, terminals 11 and 12 are inter-connected. During failure-free (on) state, terminals 11 and 14 are inter-connected.

3-phase fan motor

ther

mis

tor r

elay

Figure 9 - Example of the thermistor relay's wiring

Markings Usedm weight kgS area, surface m2V air flow rate m3/hn speed rpmt air temperature °C∆ps static pressure difference Pa∆pt total pressure difference Papd dynamic pressure Paρ air specific density kg/m3

LW sound power level dBLWA A scale sound power level dB(A)LWAokt A scale octave sound power level dB(A)LPA A scale sound pressure level dB(A)U voltage VI current AP electric input W

µ

Page 11: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

118

RP Ex, RQ Ex FansFa

ns

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

InstallationRP Ex and RQ Ex fans, including other Vento ele-ments and equipment, are not intended, due to their concept, for direct sale to end customers. Each installa-tion must be performed in accordance with a professio-nal project created by a qualified air-handling designer who is responsible for proper selection of the fan. The installation and commissioning may be performed only by a specialized assembling company licensed in accordance with generally valid regulations.The fan must be checked carefully prior its installa-tion. In particular, it is necessary to check the parts and cable insulation for damage, and to see whether the rotating parts can rotate freely. Minimum clearance be-tween rotating and fixed parts is 4 mm.It is recommended to insert elastic connections in front of and behind the fan, see figure 10.

It is advisable to place an air filter in front of the fan to protect it and the duct against dirtying and dust fou-ling.If the fan is installed in such a way that persons or objects can come into contact with the impeller, the guard grid must be mounted.

If the fans draw in air from the open space, respecti-vely if the suction of foreign objects cannot be elimina-ted, the fans' inlets must be provided with a protecting grid of IP 20 protection.

We recommend adding a 1.5 m long piece of strai-ght duct to the fan's outlet to get optimal pressure con-ditions. In cramped spaces, it is advisable to consider the necessity to situate directly behind the fan's outlet the duct adapting piece, attenuator, heat exchanger, heater, etc. Figure 11 shows the fan's outlet design and arrangement. From this figure, it is obvious that from the entire cross-section (e.g. 500 x 250), only about 1/4 of the outlet cross-section is free. This means that the airflow velocities close behind the fan can be as much as four times higher than, for example, in the inlet. The-refore, the greater the distance of the attenuators (or other resistant elements) from the outlet, the better. On the inlet side, an elastic connection will be sufficient as a distance piece in most cases.

The fan must be suspended by separate suspensi-ons, or fixed to the foundations, so that no loading can be transferred to the elastic connections or connected duct.

Anchoring to the ceiling with steel anchors and sus-pension using threaded rods (see fig. #12), perforated galvanized strips (see fig. #13) or ancillary construction is recommended for RP Ex fans. RQ Ex fans are provided on three sides with ancho-ring holes to be anchored to the foundation in one of three possible positions (see figure # 14). RQ Ex fans can be anchored with four anchoring bolts; ho-wever, we recommend using silent-blocks to eliminate the transfer of vibrations.

Free outletSpiral casing

Dividing partition

Installation, Maintenance and Service

Figure 10 - Application of elastic connections

Figure 12 - Fan anchoring

Figure 11 - Fan outlet arrangement

Figure 13 - Suspension using ancillary construction

Page 12: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

119

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

The fans can work in any position. When positioned under the ceiling, it is advisable to si-tuate the fan with its cup directed downwards to ease access to the motor termi-nal box, see figu-re # 11. If transported air is oversatura-ted with moisture or if the risk of intensive and permanent steam condensation inside the fan exists, it is advisable to situate the fan's motor cap upwards to enable better condensate drain-age!Before installation, paste self-adhesive sealing onto the connecting flange face. To connect individual parts of the Vento system, use galvanized M8 screws and nuts. It is necessary to ensure conductive connection of the flange using fan-washers placed on both sides at least on one flange connection, or use Cu conductor wiring.To brace flanges with a side longer than 40 cm, it is advisable to connect them in the middle with another screw clamp which prevents flange bar gapping (see fig. # 15).

power supply and CYKY 2Bx1,5 for the thermistor circu-it are recommended. For a list of recommended cables related to the wiring on pages 16-21, refer to table # 6.

Rubber plugRotation direction arrow

WiringThe wiring can be performed only by a qualified wor-ker licensed in accordance with national regulations. The fans are equipped with a plastic terminal box intended for Zone 1 EEx e II T6. The terminal box is fixed with screws to the fan casing, and equipped with labelled screw terminals (see figure # 16).Open the terminal box only if not energized.The wiring connection to the terminals can be perfor-med following the marking on the motor cables, descrip-tion of terminals or the label on the terminal box lid.To connect the fan motor to the supply, use only cables approved for this purpose. CYKY 4Bx1,5 for the

After starting the fan, the proper direction of the im-peller rotation must be checked. To do so, remove the rubber plug from the inspection opening in the fan cup (see. figure # 17).After starting the fan, the current must also be measured, and it must not exceed the maximum allo-wed current stated on the rating plate (Imax.). If the measured values exceed the given current value, it is necessary to check the duct system regulation.The fan can be started after its mounting into the duct system for which it has been designed, or fully throttled by closing either the intake or discharge to avoid its overloading! The fan is loaded by increasing the air flow, i.e. by releasing the throttling. n The fan installation must comply with the ČSN EN 60079-14 Standard for Electrical Appliances Intended for Explosive Gaseous Atmosphere, Art. 14 Electrical Installations in Dangerous Areas.

Table 6 - Recommended cables

Figure 14

Figure 15 – screw clamps

Figure 17

Figure 16 - All-plastic terminal box on the casing

Page 13: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

120

RP Ex, RQ Ex FansFa

ns

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

Operation, Maintenance and ServiceThe fan does not require special maintenance. During operation, it is necessary to check proper functioning of the fan, its smooth running, to keep it and its surroun-dings clean, and to load the fan only within the range given by its output characteristics.If a failure occurs, make sure that the power supply is disconnected. Check the fan for foreign objects inside and free impeller rotation. If the fan does not run after it has been restarted, the following procedures must be followed depending on the protection system used:If the fan is protected by an STD relay, turn the fan on/off using the buttons on the protecting relay. If the fan is protected by a TRN controller, turn the fan off and on using the switch on the remote controls of the controller.If the fan does not start, check the wiring and measure the motor winding impedance. If the motor is damaged, contact your supplier.Attention! When performing any maintenance or re-pairs, the device must always be disconnected from the power supply!

Installation, Maintenance and Service

Figure 14 - Wiring diagram

K1, K2 – motor thermistor terminalsU1, V1, W1– three-phase motor power supply terminals 3f - 3x 400V/50HzPE– protective conductor terminal

The wiring diagrams with front-end elements (protective relays, controllers, control units) are included in the in-stallation manual, respectively in the AeroCAD project.

three-phase motorof the fan

Page 14: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

121

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

24V=

2,5V

= 230V / 50Hz

3x 4

00V

/ 50

Hz

12V

příp

. 24V

=

24V

=

3x 400V / 50Hz

3x 400V / 50Hz24

V=

2,5V

=

3x 4

00V

/ 50

Hz

230V / 50Hz

AFan equipped with thermal protection, without Output Control

An RP (RQ) Ex fan connection in a simple venting sys-tem without output control is shown in figures # 19.a and 19.b.This type of connection ensures full thermal protection of the fan using thermistors, thermistor relay and pro-tecting relay STD. The connection shown in the figu-res enables manual turning of the fan on/off using the buttons on the protecting relay.

After pressing the button marked "I" on the STD protecting relay, the fan starts and the button will stay in the depressed position, signalling the fan's operation. The fan can be stopped by pressing the button marked "0".If the motor is overheated above 130°C due to overloading, the im-pedance of the K1 and K2 thermistors in the motor winding will be increased several times. The thermistor relay will detect the increased impedance and open contacts 11 and 14. Upon opening contacts 11 and 14, the STD pro-tecting relay circuit TK, TK will be disconnected. As a reaction to this state, the STD relay will disconnect the power supply to the overhea-ted motor. After cooling down, the motor is not automatically started. The failure must be confirmed (unblocked) by the operator by pressing the red "I" button.

BFan with Output Control and Protection Controller

An RP (RQ) Ex fan connection in a venting system with output control using the TRN controller equipped with an ORe5 control unit is shown in figures # 20.a and 20.b.In addition to the selection of the fan output within the stage range "0" - "5", this type of connection also ensu-res its protection via thermistors, thermistor relay and the protection integrated into the TRN controller.The connection shown in the pictures also enables the fan to be switched on/off manually, by the ORe5 remote controller or any other switch (like room thermostat, gas detector, pressostat, hygrostat, etc.) on the PT1 and PT2 terminals.

After turning the selector to position "1" to "5", the fan will start at the corresponding output (1 to 5), and an indicator signalling the fan's ope-ration will light up. The closed switch connected to PT1, PT2 terminals and closed terminals 11 and 14 of the thermistor relay connected to TK, TK terminals of the controller are essential for fan operation. The switch connected to PT1, PT2 terminals is used to stop and start the fan without other relations so that the fan after being started runs at the output preset on ORe5. If this possibility is not used, it will be necessary to interco-nnect terminals PT1 and PT2. If the fan is overloaded, contacts 11 and 14 of the tripping device will open due to overheating of the motor. As a reaction to this state, the controller will disconnect the power supply to the motor, and turn off the fan operation signalling indicator. After cooling down, the motor is not automatically started. First, it is necessary to confirm (unblock) the failure removal by turning the selector to position "0". After turning the selector to position "1" to "5", the fan will start at the corresponding output. In this arrangement, position "0" on the ORe5 control unit must not be blocked

thermistor relay

STD

thermistor relay

TRN

For example, detectorof explosive gas

concentrationRQ (RP) Ex

RP (RQ) Ex

Zone 1

BNV

Zone 1

BNV

Figure 19 - Fan connection

Figure 20 - Fan connection

ORe5

Page 15: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

122

RP Ex, RQ Ex FansFa

ns

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

2,5V=

3x 4

00V

/ 50

Hz

3x 4

00V

/ 50

Hz

3x 400V / 50 Hz

RQ Ex

WBC-Dex... (incl. thermistor relay)

24 V=

3x 400V / 50Hz

3x 4

00V

/ 50

Hz

2,5

V=

3x 400V / 50 Hz

RP (RQ) Ex

WBC-Dex... (incl. thermistor relay) TRN

DFan with Control Unit and Output Control

An RP (RQ) Ex fan equipped with an output controller and an OC controller connection in a more sophistica-ted venting system with a WebClima control unit (e.g. with air heating) is shown in figures # 22.a and 22.b.This type of connection ensures full thermal protection of the fan using thermistors and a WBC-Dex control unit which already contains a thermistor relay installed in the factory. Fan switching on/off is ensured by the control unit. The motor protection must always be ensured by the control unit by connecting the TK, TK thermistor ter-minals to the 5a, 5a, 5b and 5b terminals in the control unit. The OCe controller is installed in the control unit during production. This connection of the speed cont-roller enables the option of fan output in the range from stage "1" to stage "5".In the D connection example, all additional functions of the controller must always be blocked by interconnecti-ng the PT2 and E48 terminals in the controller.

The air-handling system is started by the control unit. An OCe internal controller is integrated into the control unit, which enables remote control of the controller. The OCe controller is provided only with posi-tions "1" to "5" to set the required fan output. Stages "1" to "3" can be blocked. All protection and safety functions of the fan as well as the entire system are ensured by the WebClima control unit.

CFans with Control Unit without Output Control

An RP (RQ) Ex fan without output control connection in a more sophisticated venting system equipped with a WebClima control unit (e.g. with air heating) is shown in figures # 21.a and 21.b.This type of connection ensures full thermal protection of the fan using thermistors and a WBC-Dex control unit which already contains a thermistor relay installed in the factory. Fan switching on/off is ensured by the control unit. The motor protection must always be ensured by the control unit by connecting the TK, TK thermistor ter-minals to the 5a, 5a, 5b and 5b terminals in the control unit.

The air-handling system is started by the control unit. All protection and safety functions of the fan as well as the entire system are ensu-red by the WebClima control unit.

2,5V=

Zone 1

BNV

Zone 1

BNV

Figure 21 - Fan connection

Figure 22 - Fan connection

HMI(controller)

Page 16: RP Ex, RQ Ex Fans - ProIDEA€¦ · RP Ex, RQ Ex Fans Fans RP Fans RQ Fans RO Fans RF Fans RPH Fans EX Controllers... El. heaters EO.. Water heaters VO Mixing sets SUMX Water coolers

123

RP Ex, RQ Ex Fans

Fans

RP

Fans

RQ

Fans

RO

Fans

RF

Fans

RPH

Fans

EXC

ontro

llers

...E

l. he

ater

s

EO..

Wat

er h

eate

rs

VOM

ixin

g se

ts

SUM

XW

ater

coo

lers

CH

VD

irect

coo

lers

CH

FHe

at e

xcha

nger

s

HR

VA

cces

sorie

s

...

3x 400 V / 50Hz

24 V

=24

V=

24 V

=

2,5

V=

0–10

V=

24 V

=

3x 4

00 V

/ 50

Hz

230V / 50Hz

EFan with Automatic Output Control for Special Applications

An RP (RQ) Ex fan connection in a special venting sys-tem with automatic output control using the TRN contro-ller equipped with an OXe controller integrated into the OSX control unit is shown in figures # 22.a and 22.b. Two TRN controllers can be controlled by the OSX control unit. In addition to automatic fan output control within the stage range "0" - "5", this type of connection also ensures fan protection via thermistors, thermistor relay and the protection integrated into the TRN con-troller. This type of connection enables the fan to be switched on/off manually, by any other switch (like room thermostat, gas detector, pressostat, hygrostat, etc.) on terminals PT1, PT2.Automatic selection of the controller output stage is en-sured by the OXe controller in relation to any physical quantity which is read by the active sensor equipped with an analogue output (signal source 0-10V). Ex fans use mostly an explosion gas concentration sensor.

The fan in the picture is started, controlled and protected by the TRN controller. An automatic driver of the OXe controller evaluates the continuous 0-10V signal from a converter (signal source), and in five adjustable levels switches stages "1" to "5" of the controller. Thermal or pressure converters, converters for the measurement of relative or absolute humidity, concentration of gases, vapours or explosives in air, sensors of air quality and many other converters of different physi-cal quantities can be used as sources of the control signal.The closed electrical circuit between TK, TK terminals situated in the control unit and closed external switch connected to PT1, PT2 termi-nals are essential for the fan's operation. The switch connected to PT1, PT2 terminals can be used to stop and start the fan separately without other relations. The PT1, PT2 termi-nals in the controller can also be interconnected with analogous termi-nals in the OSX control unit, and thus enable the fan to be stopped by the button from the control unit. If this possibility is not used, it will be necessary to interconnect terminals PT1 and PT2.If the fan is overloaded, contacts TK, TK in the OSX control unit will be disconnected due to overheating of the motor. As a reaction to this state, the controller will turn the overheated motor off. After cooling down, the motor is not automatically started. The failure must be con-firmed by pressing the separate unblocking button which is situated inside the OSX control unit. As most similar special installations can vary from case to case, it is advisable to consult the specific connecti-on with the manufacturer. The manufacturer will deliver an OSX cont-rol unit adapted according to the disposition, modification and number of individual devices. The following specification must be attached to your order:- Type of fan No. 1- Type of fan No. 2- Type of controller No. 1- Type of controller No. 2- Type and manufacturer of the sensor (converter) provided with a 0-10V output.- Specification of the physical quantity read by the sensor (converter) and its range.- Specification of the sensor (converter) power supply

RQ (RP) Ex

TRN

For example, a sensor of explosive gas concentration

(source of 0-10V signal);

OSX control unit for Ex fans (thermistor relay, OXe, unblocking, source)

Thermostat (optional contact)

Zone 1

Figure 23 - Fan connection