rohn · pdf filetower designs are in accordance with ansi/tia-222-f and ansi/tia-222-g, class...
TRANSCRIPT
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. MixingROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D 5 5 G G U Y E D T O W E R
100© 2011 ROHN PRODUCTS LLC
The first. The original.ROHN 55G
Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 116 for ordering information.
REV. G
includes
REV. F &
GENERAL USE
The 55G lends itself to a wide variety of uses,particularly where unusual wind loading andheight requirements exist. The 55G was designedto provide excellent strength in heights up to400’.
FEATURES
• Completely hot-dip galvanized after fabrication• Built on a 17” equilateral triangle design• High strength tubular legs joined by Zig-Zag®
cross members• Each section contains all required nuts and bolts shipped with section• Continuous solid round steel bracing
55G
1 1/2” O.D.(11 GA.)
STANDARD SECTION55G - 10’ Section
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D 5 5 G G U Y E D T O W E RS E C T I O N S
101
9 13/16”
7/16” O.D. Solid Bracing
© 2011 ROHN PRODUCTS LLC
17”PARTS & ACCESSORIES PAGES 115-116GROUNDING INFORMATION PAGE 117FOUNDATION INFORMATION PAGES 117-120
QUICK REFERENCE14 3/4”
CONCRETE BASE PLATEBPC55G*
FOR USE WITH 3/4X12PP PIER PINEMBEDDED IN CONCRETE.
Additional base sections are available, please see page 115.
Optional double braced sections are available upon request.
Optional WaveguideBrackets (KY2041A)
* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.
TOP PLATEAPL55G
FOR MOUNTING BEACON OR LIGHTNING ROD. TOP PLATE BOLTS TO THE TOP OF
A STANDARD SECTION.
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 55G90R100
117’
90’
85’
42’
80’
3/16” EHS(399#)
30.4
32.0
39.0
P/N 55G90R100 Tower Model
Windspeed (Rev. G) ROHN TowerTower Height (ft.)
EPA= Effective Projected Area
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
B U Y E R S G U I D ES T A N D A R D D E S I G N S - 5 5 G
9 0 M P H R E V . G [ 3 S E C O N D G U S T ]7 0 M P H R E V . F [ F A S T E S T M I L E ]
102© 2011 ROHN PRODUCTS LLC
1/4” EHS(665#)
Guy Initial Tension
This document is to serve as a guide for sizing and purchasing the 55G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 117-120.FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
Design Criteria
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
103© 2011 ROHN PRODUCTS LLC
P/N: 55G90R120
120’ TOWER
105’37.0 29.3OR
142’
96’
3/16” EHS(399#)
122’75’
35’ 102’
1/4” EHS(665#)
P/N: 55G90R100
100’ TOWER
85’39.0 30.4OR
117’
80’
1/4” EHS(665#)
90’42’
3/16” EHS(399#)
P/N: 55G90R110
110’ TOWER
95’37.9 29.8OR
129’
88’
1/4” EHS(665#)
100’47’
3/16” EHS(399#)
P/N: 55G90R130
130’ TOWER
115’36.1 28.7OR
155’
104’
3/16” EHS(399#)
129’76’
38’ 111’
1/4” EHS(665#)
P/N: 55G90R140
140’ TOWER
125’35.4 28.3OR
168’
112’
3/16” EHS(399#)
139’83’
41’ 119’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 2
300’ 375’ 6 6 6
3 1 3
100’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R100
FDNSBASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
11 1 1 2
325’ 425’ 6 6 6
3 1 3
110’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R110
FDNSBASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
12 1 1 3
725’ 475’ 12 6 12
3 1 3
120’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R120
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
13 1 1 3
775’ 500’ 12 6 12
3 1 3
130’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R130
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
14 1 1 3
825’ 550’ 12 6 12
3 1 3
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R140
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
32.0
31.2
30.4
29.8
29.0
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
104© 2011 ROHN PRODUCTS LLC
P/N: 55G90R150
150’ TOWER
135’34.7 27.9OR
181’
120’
3/16” EHS(399#)
151’92’
45’ 128’
1/4” EHS(665#)
P/N: 55G90R160
160’ TOWER
145’33.9 27.5OR
193’
128’
3/16” EHS(399#)
160’96’
48’ 137’
1/4” EHS(665#)
P/N: 55G90R170
170’ TOWER
155’33.3 27.2OR
206’
136’
178’115’
37’ 141’
75’155’ 3/16” EHS
(399#)
1/4” EHS(665#)
P/N: 55G90R180
180’ TOWER
165’32.8 26.8OR
219’
144’
190’124’
42’ 150’
83’166’ 3/16” EHS
(399#)
1/4” EHS(665#)
P/N: 55G90R190
190’ TOWER
175’32.4 26.5OR
232’
152’
201’131’
43’ 158’
87’175’ 3/16” EHS
(399#)
5/16” EHS(1,120#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
15 1 1 3
900’ 600’ 12 6 12
3 1 3
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R150
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
16 1 1 3
950’ 625’ 12 6 12
3 1 3
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R160
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
17 1 1 4
1525’ 675’ 18 6 18
3 1 3
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R170
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
18 1 1 4
1625’ 700’ 18 6 18
3 1 3
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R180
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
19 1 1 4
1700’ 750’ 18 6 18
3 1 3
190’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R190
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB3
28.6
28.0
27.4
27.0
26.6
GAC3455TOP
GAC3455TOP 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
105© 2011 ROHN PRODUCTS LLC
P/N: 55G90R200
200’ TOWER
185’31.9 26.2OR
245’
160’
212’139’
47’ 167’
93’185’ 3/16” EHS
(399#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
20 1 1 4
1800’ 800’ 18 6 18
3 1 3
200’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R200
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5755TOP AGK1GGX BGK2GGX
22 1 1 5
2650’ 875’ 24 6 24
3 1 3
220’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R220
FDNSBASE ANCHOR
7/16THH
6 15
3/4TBE&J
P/N: 55G90R220
220’ TOWER
205’31.1 25.7OR
270’
176’
241’
164’
41’
123’215’
3/16” EHS(399#)
194’
181’
82’5/16” EHS(1,120#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
AGK1GGX BGK2GGX
24 1 1 5
2900’ 950’ 24 6 24
3 1 3
240’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R240
FDNSBASE ANCHOR
7/16THH
6 15
3/4TBE&J
P/N: 55G90R240
240’ TOWER
225’30.3 25.3OR
296’
192’
265’
182’
45’
135’235’
3/16” EHS(399#)
213’
197’
92’
5/16” EHS(1,120#)
CPC1.5/2
3
TBSAFETY
3
CPC1.5/2
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
260’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R260
P/N: 55G90R260
260’ TOWER
245’29.6 24.8OR
321’
208’
5/16” EHS(1,120#)
202’
42’
162’
122’
77’104’
3/16” EHS(399#)
64’
82’241’
264’
290’
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
26 1 1 6
3
3 3
3/16EHS
3125’
7/16THH
6
142265
1025’
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
23
CB2G AB3
CB2G AB3
CB3G AB3
BASE INNERANCHOR
CB3G
OUTERANCHOR
AB3AB2
24.2
23.4
22.8
22.2
5/16” EHS(1,120#)
GAC5755TOP
GAC3455TOP TBSAFETY
6
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
106© 2011 ROHN PRODUCTS LLC
280’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R280
P/N: 55G90R280
280’ TOWER
265’29.0 24.4OR
347’
224’
5/16” EHS(1,120#)
222’
43’
175’
132’
82’110’
3/16” EHS(399#)
70’
85’260’
284’
315’
300’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R300
P/N: 55G90R300
300’ TOWER
285’28.4 24.1OR
373’
240’
5/16” EHS(1,120#)
242’
42’
202’162’ 3/16” EHS
(399#)
100’
82’
290’
314’
341’
108’129’158’
122’
320’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R320
P/N: 55G90R320
320’ TOWER
305’27.9 23.8OR
398’
256’
5/16” EHS(1,120#)
262’
42’
215’172’ 3/16” EHS
(399#)
100’
82’
308’
334’
366’
108’129’160’
125’
340’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R340
P/N: 55G90R340
340’ TOWER
325’27.4 23.5OR
424’
272’
5/16” EHS(1,120#)
282’
42’
202’162’ 3/16” EHS
(399#)
96’
82’
317’
364’
105’126’155’
122’
339’
392’242’
21.8
21.2
20.8
20.4
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
28 1 1 6
3
3 3
3/16EHS
3350
7/16THH
6
142265
1125’
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
CPC.5/.75
30 1 1 7
3
3 3
3/16EHS
4275’
7/16THH
6
142265
1200’
BG2142
36
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
5/16THH
36
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
32 1 1 7
33 3
3/16EHS
2250’
7/16THH
6
1/4EHS
2250’
BG2142
24
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
BG2144
12
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
34 1 1 8
33 3
3/16EHS
3325’
7/16THH
6
142265
1350’
BG2142
30
1/2TBE&J
9
BG2146
6
5/8TBE&J
15
5/16THH
30
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
142265
1275’1/4” EHS(665#)
1/4” EHS(665#)
1/4EHS
2425’
GAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
TBSAFETY
6
CPC1/1.25
3
3/8THH
12
5/16THH
24
CPC1/1.25
3
CPC1/1.25
3
3/8THH
12
BG2144
12
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
107© 2011 ROHN PRODUCTS LLC
360’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R360
P/N: 55G90R360
360’ TOWER
345’27.0 23.2OR
449’
288’
5/16” EHS(1,120#)
302’
42’
212’168’ 3/16” EHS
(399#)
100’
84’
333’
385’
108’131’161’
126’
358’
417’255’
1/4” EHS(665#)
380’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R380
P/N: 55G90R380
380’ TOWER
365’26.6 22.9OR
475’
304’
5/16” EHS(1,120#)
319’
45’
227’181’ 3/16” EHS
(399#)
110’
92’
354’
409’
119’143’174’
135’
379’
441’273’
1/4” EHS(665#)
P/N: 55G90R400
400’ TOWER
385’26.1 22.7OR
501’
320’
5/16” EHS(1,120#)
335’
46’
235’185’ 3/16” EHS
(399#)
120’
92’
370’
429’
129’151’183’
138’
397’
463’285’
1/4” EHS(665#)
20.0
19.6
19.2
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
36 1 1 8
33 3
3/16EHS
3475’
5/16THH
30
1/4EHS
2575’
3/8THH
12
142265
1450’
7/16THH
6
BG2142
30
BG2144
12
1/2TBE&J
9
AGK1GGX
23
APL1258UM
2
BG2146
6
5/8TBE&J
15
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
38 1 1 8
33
3/16EHS
3175’
5/16THH
24
1/4EHS
3275’
3/8THH
18
142265
1525’
7/16THH
6
BG2142
24
BG2144
18
15
AGK1GGX
23
APL1258UM
2
BG2146
6
5/8TBE&J
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
400’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R400
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
40 1 1 8
33
3/16EHS
2075’
5/16THH
18
1/4EHS
4700’
3/8THH
24
142265
1600’
7/16THH
6
BG2142
18
BG2144
24
9
AGK1GGX
2
APL1258UM
2
BG2146
6
1/2TBE&J
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
TBSAFETY
6
1/2TBE&J
9
TBSAFETY
6
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
3
GAC5655TOPGAC3455TOP
3
TBSAFETY
6
15
5/8TBE&J
CPC1/1.25
3
CPC1/1.25
3
CPC1/1.25
3
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
108© 2011 ROHN PRODUCTS LLC
P/N: 55G110R120
120’ TOWER
115’24.8 19.6OR
150’
96’
3/16” EHS(399#)
123’77’
38’ 103’
1/4” EHS(665#)
P/N: 55G110R130
130’ TOWER
125’24.2 19.2OR
163’
104’
3/16” EHS(399#)
133’83’
42’ 112’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 3
600’ 400’ 12 6 12
3 1 3
100’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R100
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3P/N: 55G110R100
100’ TOWER
95’26.1 20.4OR
124’
80’
3/16” EHS(399#)
102’63’
33’ 87’
1/4” EHS(665#)
P/N: 55G110R110
110’ TOWER
105’25.4 19.9OR
137’
88’
3/16” EHS(399#)
114’72’
35’ 95’
1/4” EHS(665#)
P/N: 55G110R140
140’ TOWER
135’23.6 18.9OR
175’
112’
151’101’
34’ 117’
67’131’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
11 1 1 3
675’ 450’ 12 6 12
3 1 3
110’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R110
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
12 1 1 3
725’ 500’ 12 6 12
3 1 3
120’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R120
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
13 1 1 3
800’ 525’ 12 6 12
3 1 3
130’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R130
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
14 1 1 4
1275’ 575’ 18 6 18
3 1 3
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R140
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
3
TBSAFETY
3
CB1G AB2
CB1G AB2
CB2G AB2
CB2G AB2
CB2G AB2
19.2
18.6
18.2
17.8
17.2
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
109© 2011 ROHN PRODUCTS LLC
P/N: 55G110R150
150’ TOWER
145’23.2 18.7OR
188’
120’
161’108’
36’ 125’
72’140’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
15 1 1 4
1375’ 600’ 18 6 18
3 1 3
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R150
FDNSBASE ANCHOR
3/8THH
6 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R180
180’ TOWER
175’22.0 18.0OR
227’
144’
202’
142’
35’
105’178’
3/16” EHS(399#)
161’
148’
72’
1/4” EHS(665#)
P/N: 55G110R160
160’ TOWER
155’22.8 18.4OR
201’
128’
173’116’
39’ 134’
78’150’ 3/16” EHS
(399#)
5/16” EHS(1,120#)
P/N: 55G110R170
170’ TOWER
165’22.4 18.2OR
214’
136’
184’124’
41’ 142’
83’159’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
17 1 1 4
975’ 1275’ 12 12 12
3 1 3
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R170
FDNSBASE ANCHOR
3/8THH
12 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R190
190’ TOWER
185’21.7 17.8OR
239’
152’
212’
148’
37’
111’188’
3/16” EHS(399#)
169’
156’
74’
5/16” EHS(1,120#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
16 1 1 4
1475’ 650’ 18 6 18
3 1 3
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R160
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
18 1 1 5
1550’ 1375’ 18 12 18
3 1 3
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R180
FDNSBASE ANCHOR
3/8THH
12 15
5/8TBE&J
3
TBSAFETY
3
190’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R190
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1650’
5/16THH
18
1/4EHS
675’
3/8THH
6
142265
775’
7/16THH
6
BG2142
18
5/8TBE&J
15
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
TBSAFETY
3
CB2G AB3
CB2G AB3
CB2G AB3
CB3G AB3
CB3G AB315.6
15.8
16.2
16.4
16.8
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
110© 2011 ROHN PRODUCTS LLC
P/N: 55G110R200
200’ TOWER
195’21.4 17.6OR
252’
160’
223’
156’
39’
117’198’
3/16” EHS(399#)
178’
165’
78’
5/16” EHS(1,120#)
1/4” EHS(665#)
200’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R200
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
20 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1750’
5/16THH
18
1/4EHS
725’
3/8THH
6
142265
825’
7/16THH
6
BG2142
18
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
5/8TBE&J
15
TBSAFETY
3
220’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R220
P/N: 55G110R220
220’ TOWER
215’20.8 17.2OR
278’
176’
5/16” EHS(1,120#)
182’
36’
145’
112’
70’94’
3/16” EHS(399#)
60’
73’209’
228’
253’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
22 1 1 6
33
3/16EHS
1925’
5/16THH
24
1/4EHS
825’
3/8THH
6
142265
900’
7/16THH
6
BG2142
24
BG2144
6
AGK1GGX
2
GAC5655TOP
3
BG2146
6
1/2TBE&J
6
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R240
240’ TOWER
235’20.3 16.9OR
303’
192’
5/16” EHS(1,120#)
201’
33’
167’133’ 3/16” EHS
(399#)
80’
66’
234’
254’
278’
87’104’127’
99’
240’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R240
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
24 1 1 7
3
3/16EHS
1775’
5/16THH
24
1/4EHS
1700’
3/8THH
12
142265
975’
7/16THH
6
BG2142
24
BG2144
12
AGK1GGX
23
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R260
260’ TOWER
255’19.8 16.6OR
329’
208’
5/16” EHS(1,120#)
219’
38’
183’147’ 3/16” EHS
(399#)
88’
75’
255’
277’
302’
96’116’142’
111’
1/4” EHS(665#)
1/4” EHS(665#)
260’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R260
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
26 1 1 7
33
3/16EHS
1500’
5/16THH
18
1/4EHS
2300’
3/8THH
18
142265
1050’
7/16THH
6
BG2142
18
BG2144
18
AGK1GGX
23
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
CB3G AB313.2
12.8
12.4
12.0
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB3AB2
CPC1/1.25
CPC.5/.75
CPC.5/.75
CPC.5/.75
GAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
CPC1/1.25
3
CPC1/1.25
3
3
CPC1/1.25
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
111© 2011 ROHN PRODUCTS LLC
P/N: 55G110R280
280’ TOWER
275’19.4 16.4OR
355’
224’
5/16” EHS(1,120#)
241’
35’
173’139’ 3/16” EHS
(399#)
84’
71’
264’
305’
91’110’134’
105’
283’
329’207’
1/4” EHS(665#)
280’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R280
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
28 1 1 8
33
3/16EHS
2825’
5/16THH
30
1/4EHS
2025’
3/8THH
12
142265
1150’
7/16THH
6
BG2142
30
1/2TBE&J
9
BG2144
12
AGK1GGX
23
BG2146
6
TBSAFETY
6
5/8TBE&J
15
3
P/N: 55G110R300
300’ TOWER
295’19.0 16.1OR
380’
240’
5/16” EHS(1,120#)
259’
41’
187’151’ 3/16” EHS
(399#)
100’
79’
284’
328’
108’127’152’
115’
304’
353’223’
1/4” EHS(665#)
300’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R300
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
30 1 1 8
33
3/16EHS
1675’
5/16THH
18
1/4EHS
2500’
3/8THH
18
142265
2350’
7/16THH
12
BG2142
18
1/2TBE&J
9
BG2144
18
AGK1GGX
23
BG2146
12
TBSAFETY
6
5/8TBE&J
15
3
11.6
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB211.2
CPC.5/.75
CPC.5/.75
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
CPC1/1.25
3
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
112© 2011 ROHN PRODUCTS LLC
P/N: 55G130R100
100’ TOWER
95’18.7 14.6OR
124’
80’
3/16” EHS(399#)
102’63’
33’ 87’
1/4” EHS(665#)
100’ ROHN 55GAll par ts shown intable are included
when order ingPar t No: 55G130R100
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
10 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
300’
5/16THH
6
1/4EHS
325’
3/8THH
6
142265
400’
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
3
5/16” EHS(1120#)
P/N: 55G130R110
110’ TOWER
105’18.2 14.2OR
137’
88’
3/16” EHS(399#)
114’72’
35’ 95’
1/4” EHS(665#)
110’ ROHN 55GAll par ts shown intable are included
when order ingPar t No: 55G130R110
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
11 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
325’
5/16THH
6
1/4EHS
375’
3/8THH
6
142265
450’
7/16THH
6
BG2142
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16” EHS(1120#)
P/N: 55G130R120
120’ TOWER
115’17.7 14.0OR
150’
96’
3/16” EHS(399#)
123’77’
38’ 103’
1/4” EHS(665#)
120’ ROHN 55GAll par ts shown intable are included
when order ingPar t No: 55G130R120
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
12 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
350’
5/16THH
6
1/4EHS
400’
3/8THH
6
142265
500’
7/16THH
6
BG2142
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16” EHS(1120#)
P/N: 55G130R130
130’ TOWER
125’17.3 13.8OR
163’
104’
133’83’
42’ 112’
1/4” EHS(665#)
130’ ROHN 55GAll par ts shown intable are included
when order ingPar t No: 55G130R130
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
13 1 1 3
33
FDNSBASE ANCHOR
1/4EHS
800’
3/8THH
12
142265
525’
7/16THH
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16” EHS(1120#)
CB2G AB2
CB2G AB3
CB2G AB3
CB2G AB3
18.0
16.0
14.0
12.0
GAC3455TOP
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC.5/.75
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
113© 2011 ROHN PRODUCTS LLC
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R140
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
14 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
375’
5/16THH
6
1/4EHS
900’
3/8THH
12
142265
575’
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R140
140’ TOWER
135’16.9 13.6OR
175’
112’
151’101’
34’ 117’
67’131’ 3/16” EHS
(399#)
1/4” EHS(665#)
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R150
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
15 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
400’
5/16THH
6
1/4EHS
975’
3/8THH
12
142265
600’
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R150
150’ TOWER
145’16.6 13.4OR
188’
120’
161’108’
36’ 125’
72’140’ 3/16” EHS
(399#)
1/4” EHS(665#)
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R160
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
16 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
450’
5/16THH
6
1/4EHS
1050’
3/8THH
12
142265
650’
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
12
GAC5655TOP
3
P/N: 55G130R160
160’ TOWER
155’16.3 13.2OR
201’
128’
173’116’
39’ 134’
78’150’ 3/16” EHS
(399#)
1/4” EHS(665#)
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R170
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
17 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
475’
5/16THH
6
1/4EHS
1100’
3/8THH
12
142265
700’
7/16THH
6
BG2142
6
3/4TBE&J
12
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
5/16” EHS(1120#)
5/16” EHS(1120#)
5/16” EHS(1120#)
P/N: 55G130R170
170’ TOWER
165’16.0 13.0OR
214’
136’
184’124’
41’ 142’
83’159’ 3/16” EHS
(399#)
1/4” EHS(665#)
5/16” EHS(1120#)
CB3G AB3
CB3G AB3
CB3G AB3
CB3G AB4
11.0
10.0
9.8
9.6
CPC1.5/2
CPC1/1.25
CPC1/1.25
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
114© 2011 ROHN PRODUCTS LLC
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R180
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
18 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1000’
5/16THH
12
1/4EHS
1225’
3/8THH
12
142265
725’
7/16THH
6
BG2142
12
3/4TBE&J
15
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
P/N: 55G130R180
180’ TOWER
175’15.8 12.9OR
227’
144’
202’
142’
35’
105’178’
3/16” EHS(399#)161’
148’
72’
5/16” EHS(1120#)
1/4” EHS(665#)
P/N: 55G130R190
190’ TOWER
185’15.5 12.7OR
239’
152’
215’
152’
41’
115’191’
173’
157’
82’
5/16” EHS(1120#)
1/4” EHS(665#) 190’ ROHN 55G
Al l par ts shown intable are inc luded
when order ingPar t No: 55G130R190
TOWER PARTSINCLUDED
GUYS &CONNECTIONS
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
33
FDNSBASE ANCHOR
1/4EHS
2350’
3/8THH
24
142265
775’
7/16THH
6
3/4TBE&J
15
BG2144
24
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
CB3G AB4
CB4G AB49.0
9.2
CPC1.5/2
CPC1.5/2
3/4x12PP
1
3/4x12PP
1
GG U Y E D T O W E R S - 5 5 G
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
BEARING PLATEBPL55G
CONVERTS STANDARD SECTION TO ATOP SECTION. HOLE PATTERN FITS
TB3 (2” O.D.) AND TB4 (3” O.D.) THRUSTBEARING.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
P A R T S & A C C E S S O R I E S
115© 2011 ROHN PRODUCTS LLC
ACCESSORY SHELFAS455G
FOR MOUNTING MANY POPULARROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.
FACE MOUNTDM55G2 - 2 3/8” O.D. 5’ LONGDM554 - 4 1/2” O.D. 5’ LONG
SIDE ARM BRACKETSA253UA
MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.
TOP MOUNT55TDMKD - NO MAST
55TDM2S3KD - 2 3/8” O.D. MAST55TDM25S3KD - 2 7/8” O.D. MAST55TDM3S3KD - 3 1/2” O.D. MAST
55TDM35S3KD - 4” O.D. MAST55TDM4S3KD - 4 1/2” O.D. MAST
MOUNTING TUBE PROVIDED IS 7’.
TAPERED BASE*
55TG - STANDARD
55TGIA - USE WITH A4197L BASE INSULATOR
55TGIAA - USE WITH A4722B BASE INSULATOR
INSULATOR AND PIER PIN MUST BE ORDEREDSEPARATELY.
TOP PLATEAPL55G
FOR MOUNTING BEACON OR LIGHTNING ROD.
LIGHTNING RODLRCL
5’ COPPER CLAD, MOUNTS TO APL55G.
PIER PIN3/4X12PP
FOR USE WITH BPC55G EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDEREDSEPARATELY, UNLESS BEING
PURCHASED AS PART OFA COMPLETE TOWER KIT.
5’ SHORT BASESB55G
FOR EMBEDMENT IN CONCRETE.
FLAT ROOF MOUNTFR55G*
BOLTS DIRECTLY TO FLAT ROOF SURFACE.
CONCRETE BASE PLATEBPC55G*
FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE.
CONCRETE BASE PLATE IS TO BEUSED FOR BRACKETED ANDGUYED APPLICATIONS ONLY.
Adjustable 2.5’ - 3.0’
CLIMBING HARNESSTTFBH-4D
JOURNEYMAN HARNESSTTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEMORDERING INFORMATION
TOWER HEIGHT
50’100’150’200’250’300’350’400’
PARTNUMBER
TT0504555TT1004555TT1504555TT2004555TT2504555TT3004555TT3504555TT4004555
SAFETY CABLESLIDER WITH CARABINEER
TT-WG-500-W/SMC
G G U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
P A R T S & A C C E S S O R I E S
116© 2011 ROHN PRODUCTS LLC
SAFETY RINGSR55
SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.
WORK PLATFORMWP55G
SNAPS INTO PLACE AT ANY LEVEL.NO BOLTS REQUIRED.
SAFETY CABLE SLIDER AND CLIMBINGHARNESS MUST BE ORDERED SEPARATELY.
HEAVY DUTY UNIVERSALHOUSE BRACKET
HBUTVROADJUSTABLE TO POSITION TOWER
18” - 36” FROM WALL.
THRUST BEARINGTB3 - SUPPORTS UP TO 2” O.D. MAST.TB4 - SUPPORTS UP TO 3” O.D. MAST.
MOUNTS TO BPL55G.
GUY BRACKETGA55GD
MOUNTS TO TOWER AT ANYHORIZONTAL BRACE.
TORQUE ARM STABILIZERASSEMBLY
TA55ANTI-TWIST DEVICE LOCATED IN THE
AREA OF ANTENNAS. PROVIDES SIX-WAYGUYING. BOLTS TO TOWER AT ANY
SECTION JOINT. ATTACHED WITHJOINT BOLTS. MUST BE INSTALLED AS
SECTIONS ARE JOINED TOGETHER.
TORQUE BARTB55D
OPTIONAL, FOR USE WITH GA55GD.REQUIRES (1) 3/8” SHACKLE
FOR EACH BAR.
ANTI-CLIMB PANELS455ACL3
THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.
GG U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 117© 2011 ROHN PRODUCTS LLC
REV GANCHOR GROUNDING
AGK1GGX
REV GBASE GROUNDING
BGK2GGX
A N C H O R I N F O R M A T I O N
3/8”
2”
12”
3/4”P/N STAMPED HERE
GAC3455TOP
1/2”
2 1/2”
12”
120”
1 1/4”P/N STAMPED HERE
GAC5655TOP
81”
3/4”
3”
12”
168”
1 7/16”P/N STAMPED HERE
GAC5755TOP
11/16”
13/16”
15/16”
4” x 4” x 3/8” angle
5” x 5” x 3/8” angle
CL of hole to edgeof plate = 1 1/4”
CL of hole to edgeof plate = 1”
CL of hole to edgeof plate = 1 1/4”
5” x 5” x 3/8” angle
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6” Min.
Attach to leg withsupplied leg clamp
Ground Wire
6” Min.Ground Rod Clamp
Ground Rod,3 provided (to be installed
at 120 separation at 20’ spacing.o
All around stirrupsequally spaced 12” O.C. anchored with 90hooks around a horizontal bar
Top and bottom horizontal bars equally spaced
C
B
A
Ground Line
D
Anchor rod
o
Additional bar atcenter-line eachside, when required
S T A N D A R D A N C H O R B L O C K S
Block
AB2
AB3
AB4
AB5
AB6
A
4’ - 0”
6’ - 0”
6‘ - 0”
8’ - 0”
8’ - 0”
Concrete Vol.(Cu. Yds.)
1.33 Per Block4.0 Total for 3
1.0 Per Block3.0 Total for 3
2.0 Per Block6.0 Total for 3
2.22 Per Block6.7 Total for 3
2.96 Per Block8.9 Total for 3
B
1‘ - 6”
1’ - 6”
1’ - 6”
2’ - 0”
2’ - 0”
C
4‘ - 0“
3’ - 0”
4‘ - 0“
3’ - 0”
4’ - 0”
Horizontal Bars(Qty. & Size)
(5) #6 Bars, Top Layer(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6’ - 0”
6’ - 0”
9’ - 0”
10’ - 0”
10’ - 0”
Anchor Dimensions (in.) Stirrup Size& Spacing
#3 @ 12” O.C.
#3 @ 12” O.C.
#4 @ 12” O.C.
#4 @ 12” O.C.
#4 @ 12” O.C.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
118© 2011 ROHN PRODUCTS LLC
Refer to page 119 for anchor rod installation angles.
GG U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 119© 2011 ROHN PRODUCTS LLC
A N C H O R R O D I N S T A L L A T I O N A N G L E S
120o
Ground Line
Rod Angle(in degrees)
Tower Height
100’110’120’130’140’150’160’170’180’190’200’220’240’260’280’300’320’340’360’380’400’
Inner RodNumber
GAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC5655TOPGAC5655TOPGAC5755TOPGAC5755TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOP
InnerRod
Angle424240404039393838404038374342394040404038
55G | 90MPH
Outer RodNumber
-------------
GAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOP
OuterRod
Angle-------------
4242434342424242
Tower Height
100’110’120’130’140’150’160’170’180’190’200’220’240’260’280’300’
Inner RodNumber
GAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOPGAC3455TOP
InnerRod
Angle41404040383839383838384240414039
55G | 110MPH
Outer RodNumber
-----------
GAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOP
OuterRod
Angle-----------
4344444343
Tower Height
100’110’120’130’140’150’160’170’180’190’
RodNumber
GAC3455TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5655TOPGAC5755TOPGAC5755TOPGAC5755TOP
RodAngle
41404040404040383837
55G | 130MPH
Tower Plan Anchor Rod Angle
S T A N D A R D B A S E P I E R S
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
120© 2011 ROHN PRODUCTS LLC
Base
CB1G*
CB2G
CB3G
CB4G
CB5G
A
2’ - 6”
3’ - 0”
3’ - 6”
4’ - 0”
2’ - 0”
Vertical Bars(No. & Size)
(8) #7
(10) #7
(12) #7
(12) #8
(8) #6
Concrete Vol.(Cu. Yds.)
Round Pier
1.0
1.2
1.6
2.1
1.1
B
2’ - 6”
3’ - 0”
3’ - 6”
4’ - 0”
4’ - 0”
C
N/A
N/A
N/A
N/A
1’ - 0”
Horiz. Barsin Pad
(No. & Size)
NONE
NONE
NONE
NONE
(5) #5(Total of 10)
D
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 0”
E
N/A
N/A
N/A
N/A
3’ - 3”
F
N/A
N/A
N/A
N/A
1’ - 3”
AlternateSquarePier
PLAN VIEW
A
B
No. 4 Circular ties, 3” O.C. with 24” laps
Vertical bars equally spaced
(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps
4” Projection
6”
No. 4 Circular ties, 3” Max. O.C. with 24” laps
Vertical re-bars equally spacedwith 90 hooks at bottom (for CB5G)
Roughen construction joint toa full amplitude of 1/4”
Foundation Pad
Horizontal reinforcing steel bars equally spacedeach way
C
E
D
F
ELEVATION VIEW
B
Pier Pin
Grade
* Square pier option must be used for CB1G.
A CL
LC