rocsole profiler for emulsion/sand monitoring - profiler.pdfreal business 1 2 oil in water outlet...

11
ROCSOLE PROFILER FOR EMULSION/SAND MONITORING

Upload: others

Post on 17-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • ROCSOLEPROFILER FOR EMULSION/SANDMONITORING

  • REAL BUSINESS

    1 2OIL IN WATER OUTLET

    TOTAL LOSS PER DAY:

    SAND IN SEPARATOR

    300,000-600,000 USD 5 MUSD

    Loss of separation volume and retention time – off-spec production, required to do an unplanned shutdown. This can lead to an emergency unscheduledproduction stop and loss; 2-5 days

    SO 10 – 25 MUSD LOSS

    Penalty 3-6 USD/brl, so on a 100,000 BOPD @ 50 USDCASES

    Many brownfield separators off max performance and hence production not maximized – loss of revenue, which can be several MUSD per day3

    DETECT SEPARATORPERFORMANCE & ASSESSMENTFOR INTERNALS ARRANGEMENT

    (retrofit of new, if required)

  • BENEFITSREAL TIMEPROCESSOPTIMISATION

    IMPROVES ASSETENVIRONMENTALCOMPLIANCE

    LOWMAINTENANCE

    24/7 DATA MONITORINGALL DATA TO DATA BASE

    $

    $

    OIL FIELDLIFE CYCLEOPTIMIZATION

    INCREASEDPRODUCTIONTHROUGHPUT

    REDUCED NEED FORSHUTDOWNS & OPTIMIZED CHEMICALS COSTS

    IMPROVED SEPARATIONEFFICIENCY BYOPTIMIZING THE EMULSION

    $

    $

  • PROFILER IN SEPARATORSBEFORE AFTER

    SEPARATOR

    PROFILE

    TOMOGRAPHIC IMAGEROCSOLE PROFILER

    https://www.rocsole.com/products/applications/emulsion-watch

    https://www.rocsole.com/products/applications/emulsion-watch

  • FIELD RESULTS:IMPROVE SEPARATION EFFICIENCYWITH FULL LEVEL PROFILING & EMULSION MONITORING

  • DELIVERY CONTENT

    https://www.rocsole.com/faq/delivery-content

    https://www.rocsole.com/faq/delivery-content

  • PROFILERIN TANKS(LITI)

  • PROFILER IN TANKSBEFORE AFTER

    Probe Sensor is installed from the top using a intrinsically safe (zone 0) cable conductor for power and data. This type of installation is usually more efficient and makes the vertical positioning of the sensor very easy.The electronics/power feed unit is IECEx Zone 1 certified.

    TOMOGRAPHIC IMAGEMETALLIC CABLE CONDUCTOR

    https://www.rocsole.com/

    products/applications/em

    ulsion-watch

    ROCSOLE PROFILER

    https://www.rocsole.com/products/applications/emulsion-watch

  • NON NUCLEONICà SAFE, IMPROVED HSEà REDUCED ADMIN

    REDUCED CAPEXVS. NUCLEONIC$

    EQUAL PERFORMANCEVS. NUCLEONIC

    EXTREMELY ROBUST –WORKS EVENCONTAMINATED

    COMPLETE DATA –FULL PROFILING

    AVOID H2S SAFETYRISK WHEN WORKINGWITH MANUALSAMPLES IN TANKS

    MAIN BENEFITS

  • CONTACT

    PEKKA KAUNISTOVICE PRESIDENT SALES+358 40 024 [email protected]

    http://www.rocsole.com/

  • CONTACT

    PASI LAAKKONENCBO+358 40 147 [email protected]

    http://www.rocsole.com/