rkg pi containmentprobenehmer depi-cont.pn-17659/3 gbpi ... · 01/02 extremely hazardous very...

2
01/02 EXTREMELY HAZARDOUS VERY HIGHLY HAZARDOUS HIGHLY HAZARDOUS HAZARDOUS MODERATELY HAZARDOUS LOW HAZARD 6 5 4 3 2 1 < 0.1 0.1 – 1 1 – 10 10 – 100 100 – 1,000 1,000 – 5,000 μg/m3 1 1 – 10 10 – 100 100 – 1,000 1,000 – 10,000 > 10,000 μg/day OEB Occupational Exposure Band OEL Occupational Exposure Limit ADE Acceptional Daily Exposure PRODUCT INFORMATION GBPI-Cont.PN-17678/1 | © REMBE® Kersting | All rights reserved | Valid from 14.05.2018 | Subject to technical changes without notice OEB4. APPROVED. CERTIFIED. SAFE. Sampling in the containment area presents users with major chal- lenges. On the one hand the system always must remain closed due to the toxic media it contains, on the other hand, it has to be opened for sampling. With its automated in-line sampling system, REMBE® Kersting offers maximum safety and ease, in order to increase efficiency in process management. Operation With the containment sampler sampling occurs using the Smart- Glide p* cup sampler. Sampling is transported through the sampling system. The point of withdrawal as well as the sample collection point are separated from the continuing process with pneumatic pinch valves. Their tightness has been tested according to DIN 12266-1 P12 leak rate A inclusive protocol. Because of the pressure in the testing intermediate chamber this pressure is monitored by a pressure transmitter – approved according to ATEX product line 2014/34/EU. The filter system for the pressure equalisation of the sample chamber is according to filter class H13. In addition the con- tainment sampler includes a compressed air storage with a safety circuit, in order to keep the pneumatic actuated pinch valves closed in case of a pressure drop. At the end of the sampling process the samples are captured in a collection hose with a length of 20m and packaged for secure transportation. * Details on SmartGlide p on p. 02 Your Benefits No release of toxic substances. Maximum product protection. Guaranteed leak-tightness in the process. Sample size determined by cup size. Precise process management. CONTAINMENT SAMPLER Sampling of toxic media You can find detailed information and contacts for the Containment Sampler on: www.rembe-kersting.com or contact us at: +49 2961 7405-300, [email protected]. Certified according to PED and TA-Luſt.

Upload: others

Post on 24-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RKG PI Containmentprobenehmer DEPI-Cont.PN-17659/3 GBPI ... · 01/02 extremely hazardous very highly hazardous highly hazardous hazardous moderately hazardous low hazard 6 5 4 3 2

01/02

EXTREMELY HAZARDOUS

VERY HIGHLYHAZARDOUS

HIGHLYHAZARDOUS

HAZARDOUS

MODERATELYHAZARDOUS

LOWHAZARD

654321

< 0.1

0.1 – 1

1 – 10

10 – 100

100 – 1,000

1,000 – 5,000

µg/m3

1

1 – 10

10 – 100

100 – 1,000

1,000 – 10,000

> 10,000

µg/day

OEB Occupational Exposure Band

OELOccupational

ExposureLimit

ADEAcceptional Daily Exposure

1,000 – 5,000

µg/mg/m

Occupational

OEL

EXTREMELY HAZARDOUS

VERY HIGHLYHAZARDOUS

HIGHLYHAZARDOUS

HAZARDOUS

MODERATELYHAZARDOUS

LOWHAZARD

OEB

< 0.1

0.1 – 1

1 – 10

10 – 100

100 – 1,000

1

1 – 10

10 – 100

100 – 1,000

1,000 – 10,000

EXTREMELY HAZARDOUS

VERY HIGHLYHAZARDOUS

HAZARDOUS

HAZARDOUS

MODERATELYHAZARDOUS

HAZARD

< 0.1< 0.1

0.1 – 1

1 – 10

10 – 100

100 – 1,000

PRODUCT INFORMATION

GB

PI-C

ont.P

N-1

7678

/1 |

© R

EMB

E® K

erst

ing

| All

righ

ts re

serv

ed |

Valid

from

14.

05.2

018

| Sub

ject

to

tech

nica

l cha

nges

wit

hout

not

ice

OEB4. APPROVED. CERTIFIED. SAFE.

Sampling in the containment area presents users with major chal-lenges. On the one hand the system always must remain closed due to the toxic media it contains, on the other hand, it has to be opened for sampling. With its automated in-line sampling system, REMBE® Kersting offers maximum safety and ease, in order to increase efficiency in process management.

OperationWith the containment sampler sampling occurs using the Smart-Glide p* cup sampler. Sampling is transported through the sampling system. The point of withdrawal as well as the sample collection point are separated from the continuing process with pneumatic pinch valves. Their tightness has been tested according to DIN 12266-1 P12 leak rate A inclusive protocol. Because of the pressure in the testing intermediate chamber this pressure is monitored by a pressure transmitter – approved according to ATEX product line 2014/34/EU. The filter system for the pressure equalisation of the sample chamber is according to filter class H13. In addition the con-tainment sampler includes a compressed air storage with a safety circuit, in order to keep the pneumatic actuated pinch valves closed in case of a pressure drop. At the end of the sampling process the samples are captured in a collection hose with a length of 20m and packaged for secure transportation.* Details on SmartGlide p on p. 02

Your Benefits• No release of toxic substances.

• Maximum product protection.

• Guaranteed leak-tightness in the process.

• Sample size determined by cup size.

• Precise process management.

CONTAINMENT SAMPLER

Sampling of toxic media

You can find detailed information and contacts for the Containment Sampler on: www.rembe-kersting.comor contact us at: +49 2961 7405-300, [email protected].

Certifi ed according to

PED and TA-Lu� .

Page 2: RKG PI Containmentprobenehmer DEPI-Cont.PN-17659/3 GBPI ... · 01/02 extremely hazardous very highly hazardous highly hazardous hazardous moderately hazardous low hazard 6 5 4 3 2

Consulting. Engineering. Products. Service.

Product InformatIon

GB

PI-C

ont.P

N-1

7678

/1 |

© R

EMB

E® K

erst

ing

| All

righ

ts re

serv

ed |

Valid

from

14.

05.2

018

| Sub

ject

to

tech

nica

l cha

nges

wit

hout

not

ice

02/02

Technical data

Material | Stainless steel (product contact)

1.4404 / 1.4301

Material | Sealing (product contact)

FPM EPDM or PTFE

Max. permissible temperature60 °C 180 °C optional

Max. permissible operating pressure -20 mbar g up to 0,1 bar g at 200 °C

Approval

ATEX Zone 20/21 PED TA-Luft

Designs

TypeSample volume

[ml]Fill tube – Ø | DN

[mm]Connection | DN

[mm]Ejection ports | DN

[mm]

SmartGlide p mini

40

150 80

50 200

250

SmartGlide p mini GMP

40

150 80

50 200

250

SmartGlide p

160

250 125

50 300

350

SmartGlide p maxi

250

350 150

50 400

450

SmartGlide p [Cup Sampler]

Zur Heide 35 | 59929 Brilon, Germany | T +49 2961 7405-300 | F +49 2961 [email protected] | www.rembe-kersting.com

Application and operationThe SmartGlide is used to sample free-falling media inside drop tubes and drop shafts. To remove the medium the sample cup moves into the process and captures a defined amount of the medium – up to 250 ml* depending on the SmartGlide type. After retraction, the cup is tilted and the removed sample is dispensed into a preselected sample container such as the sample collection system LayFlat.* Type SmartGlide maxi