2
RINS1722-1 GREEN PULSING Connecting to network ORANGE ON When making a call ORANGE ORANGE GREEN SIGNAL STRENGTH ON = Signal Strength Full SIGNAL STRENGTH ON = Signal Strength 50% SIGNAL STRENGTH OFF = No Signal Strength 12V DC Connection Modem Data Connection SIM CARD slot Inserting a SIM Card SIM CARD NOT PROVIDED The GPRS Modem is compatible with GPRS networks and will not work with networks that provide a 3G Signal only (for example the 3 network). The Printed Circuit Board LED Status The DIGI-GPRS is only available for the PCX 46 and Enforcer V10 and above. Antenna Connection Status LEDs Troubleshooting: - If no signal strength is displayed, try relocating the antenna in a new location. - If the GPRS is not dialling out, check the modem is enabled in programming, the SIM card is inserted and the modem data connection is connected correctly. Also check to see if the GREEN LED is pulsing which will show that it is connecting to the network. - If no LEDs are displayed, check the power connection or connect a separate +12V to the GPRS - If the GPRS is not recognised with the control panel, power down and back up. x4 LARGE HOUSING: 8x Screws M3 x 5 4x Pillars M3 x 8 SMALL HOUSING: 4 x Screws 4x 1/4 ENFORCER HOUSING: Clips into place DIGI-GPRS GPRS Digital Communicator T: +44(0)845 6434 999 (local rate) Or T: +44(0)1709 535225 (For Alarm Engineer only) Customer Support opening hours: 8:00am – 6.30pm Monday to Friday (Micro SD slot for future use)

Upload: phamdan

Post on 24-May-2018

218 views

Category:

Documents


2 download

TRANSCRIPT

RINS1722-1

GREEN PULSINGConnecting to network

ORANGE ONWhen making a call

ORANGE

ORANGE GREEN

SIGNAL STRENGTHON = Signal Strength Full

SIGNAL STRENGTHON = Signal Strength 50%

SIGNAL STRENGTHOFF = No Signal Strength

12V DCConnection

ModemData

Connection

SIM CARD slot

Inserting a SIM Card

SIM CARD NOT PROVIDEDThe GPRS Modem is compatible with GPRS networks and will not work with networks that provide a 3G Signal only (for example the 3 network).

The Printed Circuit Board LED StatusThe DIGI-GPRS is only available for the PCX 46 and Enforcer V10 and above.

AntennaConnection

Status LEDs

Troubleshooting:- If no signal strength is displayed, try relocating the antenna in a new location.- If the GPRS is not dialling out, check the modem is enabled in programming, the SIM card is inserted and the modem data connection is connected correctly. Also check to see if the GREEN LED is pulsing which will show that it is connecting to the network.- If no LEDs are displayed, check the power connection or connect a separate +12V to the GPRS - If the GPRS is not recognised with the control panel, power down and back up.

x4

LARGE HOUSING:8x ScrewsM3 x 5

4x PillarsM3 x 8

SMALL HOUSING:4 x Screws4x1/4

ENFORCER HOUSING:Clips into place

D I G I - G P R SGPRS Digital Communicator

T: +44(0)845 6434 999 (local rate) Or T: +44(0)1709 535225 (For Alarm Engineer only)Customer Support opening hours: 8:00am – 6.30pm Monday to Friday

(Micro SDslot for future use)

Pyronix Ltd, Secure House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY. E: [email protected]. W: www.pyronix.com

The GPRS module is used to communicate either via Contact ID IP, Fast Format IP, SIA IP or SMS. It will also enable remote uploading/downloading via a PC to the control panel.

Antenna: The supplied antenna must be connected as shown above. The antenna then must be situated in a position where the signal strength is high - this can be monitored via the LEDs.If the SIM card used is pay-as-you-go - ensure that it has credit.Printed Circuit Board12V DC Connection: The power connection for the GPRS Module. Modem Data Connection: Connection for data to the control panel.SIM Card: Must be present for the GPRS module to operateTechnical Specification:Formats: Fast Format IP, Contact ID IP, SIA IP, SMS , supports upload/downloadingVoltage: +12VDCQuiescent: 40mA (In use: 420mA)Dimensions: 110 x 56 x 10mmPlease see the control panel (that this is being connected to) user, programming and quick set up manuals for further information. Minimum time for the detection of GSM/GPRS fault signal = 2 minutes 30 seconds.

Connection to the PCX 46 (Export only) control panel

GPRS Antenna

Information : The Digi-GPRS can only be used on PCX 46 (Export only) and Enforcer version 10 and above control panels.

For electrical products sold within the European Community. At the end of the electrical products useful life, it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.

NOTE: When connecting the GPRS module, make sure that the control panel is fully powered down (mains and battery).

NOTE: When connecting a Digi GPRS to the Enforcer control panel, please use the power connector marked ‘GSM modem’ on the inside of the plastics.

Compliance:Certified as SP5, for further information please see EN 50131-1: 2006 table 10Environmental Class IIEN 61000-6-3:2007 EN 60950-1:2006 +A12: 2011.ETSI EN 301 511:V9.0.2 ETSI EN 301 489-1 V1.8.1/ -7 V1.3.1CLC/ TS 50136-9: 2013EN 50136-1: 2012

ATE INPUTS