rf signal management - goamt.com db ctp -20 db stp common p1 p2 p3 p4 pad pad pad pad. rf signal...
TRANSCRIPT
RF Signal Management
Passive Products
®
Dual 2-Way and Triple 2-Way Module Specifi cations
PatentedU.S.# 6,842,348
Splitting/Combining Modules:
Ordering Information
Specifi cations subject to change without notice. MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 1 of 6
Triple 2-Way(front & rear views)
Functional Schematics
5RU Standard RF Chassis(front view)
Part Number DescriptionMN2-2TSPF Dual 2-Way Splitter: 20 dB Front Test Port, Pads, F ConnectorsMN2-2TSPB Dual 2-Way Splitter: 20 dB Front Test Port, Pads, BNC ConnectorsMN2-2TCPF Dual 2-Way Combiner: 20 dB Front Test Port, Pads, F ConnectorsMN2-2TCPB Dual 2-Way Combiner: 20 dB Front Test Port, Pads, BNC ConnectorsMN2-3PF Three 2-Way Splitter/Combiners in One Module; Pads, F ConnectorsMN2-3PB Three 2-Way Splitter/Combiners in One Module: Pads, BNC Connectors
Dual 2-Way(front & rear views)
PAD
PAD
P2
P1COMMON B
-20 dB TEST B
PAD
PAD
P2
P1COMMON A
-20 dB TEST A
Dual 2-Way Splitter
Dual 2-Way CombinerPAD P2
PAD P1COMMON B
-20 dB TEST B
PAD P2
PAD P1COMMON A
-20 dB TEST A
Triple 2-WayPAD P2
PAD P1
COMMON
PAD P2
PAD P1
COMMON
PAD P2
PAD P1
COMMON
www.amt.com
4-WaySplitter/Combiner
(front & rear views)
4-Way Splitter/Combiner Module Specifi cations
RF Signal Management
PatentedU.S.# 6,842,348
®
Splitting/Combining Modules (cont’d):
Specifi cations subject to change without notice. MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 2 of 6
Ordering Information Functional Schematic
Part Number DescriptionMN4SCF 4-Way Splitter/Combiner: 20 dB Front Test Port, Pads, F Connectors
4-Way Splitter/Combiner
-20 dB CTP -20 dB STP
P4P3P2P1COMMON
PAD PAD PAD PAD
RF Signal Management
® PatentedU.S.# 6,842,348
Splitting/Combining Modules (cont’d):
4-Way Combiner/Splitter Module Specifi cations
Specifi cations subject to change without notice. MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 3 of 6
Ordering Information
Part Number DescriptionMN4CSF 4x4 Service Group Combiner/Splitter, Test Point, Pads, F ConnectorsMN4CSB 4x4 Service Group Combiner/Splitter, Test Point, Pads, BNC Connectors
Functional Schematic
4-WayCombiner/Splitter
(front & rear views)
4-Way Combiner/Splitter
-20 dB TEST POINT
C1C2C3C4
PAD PAD PAD PAD
S1S2S3S4
PAD PAD PAD PAD
Dual 4-Way(front & rear views)
4-Way(front & rear views)
Splitting/Combining Modules (cont’d):
Specifi cations subject to change without notice. MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 4 of 6
Ordering InformationPart Number DescriptionMN4TSPF 4-Way Splitter: 20 dB Front Test Port, Pads, F ConnectorsMN4TSPB 4-Way Splitter: 20 dB Front Test Port, Pads, BNC ConnectorsMN4TCPF 4-Way Combiner: 20 dB Front Test Port, Pads, F ConnectorsMN4TCPB 4-Way Combiner: 20 dB Front Test Port, Pads, BNC ConnectorsMN4-2TSPF 2- 4-Way Splitters in One Module: 2- 20 dB Front Test Ports, Pads, F ConnectorsMN4-2TSPB 2- 4-Way Splitters in One Module: 2- 20 dB Front Test Ports, Pads, BNC ConnectorsMN4-2TCPF 2- 4-Way Combiners in One Module: 2- 20 dB Front Test Ports, Pads, F ConnectorsMN4-2TCPB 2- 4-Way Combiners in One Module: 2- 20 dB Front Test Ports, Pads, BNC Connectors
4-Way and Dual 4-Way Module Specifi cations (Splitters or Combiners)
RF Signal Management
PatentedU.S.# 6,842,348
®
Functional Schematics4-Way Splitter
PAD
PAD
PAD
PAD
P4
P3
P2
P1-20 dB TEST POINT
COMMON
4-Way CombinerPAD
PAD
PAD
P4
P3
P2
P1-20 dB TEST POINT
COMMON
PAD
Dual 4-Way SplitterPADPAD
PADPAD
P4P3
P2P1
COMMON B
-20 dB TEST B
P4PADPAD
PADPAD
P3
P2P1
COMMON A
-20 dB TEST A
Dual 4-Way CombinerP4PAD
PAD
PADPAD
P3
P2P1
P4P3
PADPAD
PADPAD
P2P1
COMMON A
-20 dB TEST A
COMMON B
-20 dB TEST B
8-Way(front & rear views)
8-Way Module Specifi cations
Splitting/Combining Modules (cont’d):
Specifi cations subject to change without notice. MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 5 of 6
Ordering Information
RF Signal Management
® PatentedU.S.# 6,842,348
Functional Schematics* = EQ dB value (1 or 2 dB)
Part Number DescriptionMN8TSPF-E 8-Way Splitter: 20 dB Front Test Port, Pads, F Connectors, 1 dB Plug-in EQMN8TSPB-E 8-Way Splitter: 20 dB Front Test Port, Pads, BNC Connectors, 1 dB Plug-in EQMN8TCPF-E 8-Way Combiner: 20 dB Front Test Port, Pads, F Connectors, 1 dB Plug-in EQMN8TCPB-E 8-Way Combiner: 20 dB Front Test Port, Pads, BNC Connectors, 1 dB Plug-in EQMN8TCPF-E-HI 8-Way Combiner: 20 dB Front Test Port, 8 dB Pads, F Connectors, 2 dB EQ
8-Way SplitterPAD
PAD
PAD
P8P7
P2
P1PAD
COMMON
-20 dB TEST POINT
*dB EQ
8-Way Combiner PAD
PAD
PADPAD
*dB EQ
P8P7
P2
P1
COMMON
-20 dB TEST POINT
16-Way(front & rear views)
16-Way Module Specifi cations
Splitting/Combining Modules (cont’d):
Specifi cations subject to change without notice.MAXNET specifi cations are only valid when ATX plug-in pads & EQs are used.
Page 6 of 6
Printed in Canada Rev. 02/10 (ANW0662)
ISO9001
REGISTERED
1-501 Clements Road West, Ajax, ON L1S 7H4 CanadaTel (905) 428-6068 Toll Free (800) 565-7488 Fax (905) 427-1964 Toll Free Fax (866) 427-1964
www.atxnetworks.com [email protected]
Ordering Information
RF Signal Management
PatentedU.S.# 6,842,348
®
Functional Schematics
For Plug-In PAD & EQ specifi cations & ordering information, see RF Passive Plug-In Pad & EQs spec sheet.
Part Number DescriptionMN16TSPF-E 16-Way Splitter: 20 dB Front Test Port, Pads, F Connectors, 2 dB Plug-in EQMN16TSPB-E 16-Way Splitter: 20 dB Front Test Port, Pads, BNC Connectors, 2 dB Plug-in EQMN16TCPF-E 16-Way Combiner: 20 dB Front Test Port, Pads, F Connectors, 2 dB Plug-in EQMN16TCPB-E 16-Way Combiner: 20 dB Front Test Port, Pads, BNC Connectors, 2 dB Plug-in EQ
16-Way Splitter P16P15
P2P1
PAD
PAD
PAD
PAD
2 dB EQCOMMON
-20 dB TEST
16-Way Combiner P16P15
P2P1
PAD
PAD
PAD
PAD
2 dB EQCOMMON
-20 dB TEST