revision c ecue-xx-xxx-xx-xx-xx-2-xx pb...

4
THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC. PROPRIETARY NOTE * * THIS PRODUCT MANUFACTURED WITH LEAD-FREE PROCESSING Pb DESIGNED & DIMENSIONED IN MILLIMETERS[INCHES] C C DO NOT SCALE FROM THIS PRINT No OF PAIRS END 2 OPTION ASSEMBLY LENGTH SHIELDED CABLE TYPE OPTION WIRING OPTION (SEE TABLE 1) -2 -08 (T3 CABLE ONLY) 007 - 999 cm (SEE NOTE 8 & 10) -T3: TF-34100C-04-S-T-TB-0700 (34AWG TWINAX, 8 PAIRS ONLY) -FF: ECUE -01 "A1 TO A19" -02 "A1 TO B1" -B4 (8 PAIR ONLY) "A1 TO B19" (SEE NOTE 10) -2: 28Gb WAFER BODY BLANK: STANDARD FIREFLY -D1: DECOUPLING CAPACITORS (SEE NOTE 7) ONLY AVAILABLE WITH -02 & -B4 WIRE OPTION ECUE-XX-XXX-XX-XX-XX-2-XX ASSEMBLY LENGTH (cm) 1% C A19 A1 HDRL-11 (SEE NOTE 5) J2 J1 A19 A1 PCB-109053-ECUE-02 (2 PLCS) SUB-TF-34100C-04-S-T-TB-0700 11.50 .453 REF 20.10 .791 REF B1 B19 B19 B1 10 01 10 01 FIG 1 WIRING OPTION -01 ECUE-08-XXX-T3-FF-01-2 SHOWN FIREFLY CABLE ASSEMBLY SHEET OF BY: ECUE-XX-XXX-XX-XX-XX-2-XX DWG. NO. DESCRIPTION: DO NOT SCALE DRAWING JERRY SU 05/19/2017 4 1 TOLERANCES DO NOT APPLY TO REFERENCE DIMENSIONS. .X: .3[.01] 2 .XX: .13[.005] .XXX: .051[.0020] DECIMALS ANGLES TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS. DECIMALS ANGLES F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-2-XX-MKT.SLDDRW 520 PARK EAST BLVD, NEW ALBANY, IN 47150 PHONE: 812-944-6733 FAX: 812-948-5047 e-Mail [email protected] code 55322 NOTES: 1. C REPRESENTS A CRITICAL DIMENSION. 2. PARTS TO BE PROCESSED PER SAMTEC WORKMANSHIP GUIDELINES. 3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED. 4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V. 5. LABEL TO BE CENTERED ON CABLE AS SHOWN. LABEL TO CONTAIN: LINE 1 - PART NUMBER “ECUE-XX-XXX-XX-XX-XX-2-XX” LINE 2 - SHOP ORDER NUMBER “XXXXXX” LINE 3 - DATE CODE “XXXXX” LINE 4 - PATENT PENDING 6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS, REFERENCE SAMTEC PACKAGING STANDARD 7. -D1 OPTION USES 0.1µF DECOUPLING CAPACITORS. 8. CABLE LENGTHS LONGER THAN 150 cm NOT SUPPORTED BY SI TEST DATA. 9. PIN 3 ON UCC8 CONNECTION TIED TO GROUND, REMAINDER ARE NO CONNECT. 10. MINIMUM LENGTH 10 CM FOR -B4 WIRING OPTION. 11. REFER TO PREP-SPEC.PDF FOR CABLE PREP DIMENSIONS. ASSEMBLY USES HIGH SPEED PCB PREP. HOUSING: LCP LATCH: STAINLESS STEEL WELD TAB: BRASS CABLE: JACKET: PVC DIELECTRIC: FEP CONDUCTORS: SILVER PLATED COPPER SHIELD: SERVED SILVER PLATED COPPER PCB: FR4, COPPER MATERIAL: REVISION C

Upload: others

Post on 07-Jul-2020

21 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REVISION C ECUE-XX-XXX-XX-XX-XX-2-XX Pb …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-2-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

THIS PRODUCT MANUFACTUREDWITH LEAD-FREE PROCESSINGPb

DESIGNED & DIMENSIONEDIN MILLIMETERS[INCHES]

CC

DO NOTSCALE FROM

THIS PRINT

No OF PAIRS

END 2 OPTION

ASSEMBLY LENGTH

SHIELDED CABLE TYPE

OPTION

WIRING OPTION (SEE TABLE 1)

-2

-08 (T3 CABLE ONLY)

007 - 999 cm (SEE NOTE 8 & 10)

-T3: TF-34100C-04-S-T-TB-0700 (34AWG TWINAX, 8 PAIRS ONLY)

-FF: ECUE

-01 "A1 TO A19" -02 "A1 TO B1"-B4 (8 PAIR ONLY) "A1 TO B19" (SEE NOTE 10)

-2: 28Gb WAFER BODY

BLANK: STANDARD FIREFLY-D1: DECOUPLING CAPACITORS (SEE NOTE 7) ONLY AVAILABLE WITH -02 & -B4 WIRE OPTION

ECUE-XX-XXX-XX-XX-XX-2-XX

ASSEMBLY LENGTH (cm) 1% CA19

A1

HDRL-11(SEE NOTE 5)

J2J1 A19

A1

PCB-109053-ECUE-02(2 PLCS)

SUB-TF-34100C-04-S-T-TB-0700

11.50 .453REF

20.10 .791 REFB1

B19

B19

B110

01 10

01FIG 1WIRING OPTION -01

ECUE-08-XXX-T3-FF-01-2 SHOWN

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-2-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

JERRY SU 05/19/2017 41

TOLERANCES DO NOT APPLYTO REFERENCE DIMENSIONS.

.X: .3[.01] 2

.XX: .13[.005]

.XXX: .051[.0020]

DECIMALS ANGLESTOLERANCES ARE:

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN MILLIMETERS.

DECIMALS ANGLES

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-2-XX-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

NOTES: 1. C REPRESENTS A CRITICAL DIMENSION. 2. PARTS TO BE PROCESSED PER SAMTEC WORKMANSHIP GUIDELINES. 3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED. 4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V. 5. LABEL TO BE CENTERED ON CABLE AS SHOWN. LABEL TO CONTAIN:

LINE 1 - PART NUMBER “ECUE-XX-XXX-XX-XX-XX-2-XX”LINE 2 - SHOP ORDER NUMBER “XXXXXX”LINE 3 - DATE CODE “XXXXX” LINE 4 - PATENT PENDING

6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS, REFERENCE SAMTEC PACKAGING STANDARD 7. -D1 OPTION USES 0.1µF DECOUPLING CAPACITORS. 8. CABLE LENGTHS LONGER THAN 150 cm NOT SUPPORTED BY SI TEST DATA. 9. PIN 3 ON UCC8 CONNECTION TIED TO GROUND, REMAINDER ARE NO CONNECT.10. MINIMUM LENGTH 10 CM FOR -B4 WIRING OPTION.11. REFER TO PREP-SPEC.PDF FOR CABLE PREP DIMENSIONS. ASSEMBLY USES HIGH SPEED PCB PREP.

HOUSING: LCPLATCH: STAINLESS STEELWELD TAB: BRASSCABLE: JACKET: PVC DIELECTRIC: FEP CONDUCTORS: SILVER PLATED COPPER SHIELD: SERVED SILVER PLATED COPPERPCB: FR4, COPPER

MATERIAL:

REVISION C

Page 2: REVISION C ECUE-XX-XXX-XX-XX-XX-2-XX Pb …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-2-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

FIRST CABLE CUT LENGTH = ASSEMBLY LENGTH (cm) - "A" (mm) ± 1%

(SEE TABLE 3)

IN PROCESS 1SOLDER FIRST CABLE TO PCB

SECOND CABLE CUT LENGTH = ASSEMBLY LENGTH (cm) - "B" (mm) ± 1%

(SEE TABLE 3)

IN PROCESS 2SOLDER SECOND CABLE TO PCB

WT-101-01-T

PRESS FIT HOLES

ECUE-12-4

6.08 .239APPLY TO BOTH ENDS

OF THE HOUSING

C

IN PROCESS 3INSERT WELD TABS & ATTACH TO BOARD

IN PROCESS 4ATTACH LATCH AND

ROTATE INTO DOWN POSITION

LTC-43-01

IN PROCESS 5SOLDER WELD TABS

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-2-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

JERRY SU 05/19/2017 42

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-2-XX-MKT.SLDDRW

REVISION C

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 3: REVISION C ECUE-XX-XXX-XX-XX-XX-2-XX Pb …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-2-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

A19

A1

J1 J2

B19

B1

SUB-TF-34100C-04-S-T-TB-0700

PCBA-204891-ECUE-DC-01(2 PLCS)

B1

B19

FIG 2WIRING OPTION -02

ECUE-08-XXX-T3-FF-02-2-D1 SHOWN(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)

A1

A19

SHEET OF

FIREFLY CABLE ASSEMBLY

BY:ECUE-XX-XXX-XX-XX-XX-2-XXDWG. NO.

DESCRIPTION:

JERRY SU 05/19/2017 43F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-2-XX-MKT.SLDDRW

REVISION C

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 4: REVISION C ECUE-XX-XXX-XX-XX-XX-2-XX Pb …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-2-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

ORANGE CABLE COLOR SHOWNFOR ROUTING CLARITY ONLY

(CABLES CROSS)A19

A1

A1

A19

J1 J2

B1

B1B19

B19

FIG 3WIRING OPTION -B4

ECUE-08-XXX-T3-FF-B4-2-D1 SHOWN(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-2-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

JERRY SU 05/19/2017 44SHEET SCALE: 1:1

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-2-XX-MKT.SLDDRW

REVISION C

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322