return to site medical device ... · regulatory path reimbursement path ... medical device...

1
Tasks / Functional Groups Cross-Functional Management Markets & Marketing Writing and Publications Research & Development Legal / IP Regulatory Reimbursement Manufacturing & Operations Quality Pre-Clinical Clinical Data and Statistics Sales Market Opportunity Basis for Competition PHASE 0 Evaluation / Opportunity & Risk Analysis Financial Review Business Model Development Market Analysis Competitive Assessment “PRD” (1) Business Plan & Presentations Literature Search Early Risk Assessment & Concept Approach Legal / IP Analysis, Clearance Opinion Regulatory Path Reimbursement Path Manufacturing plan Quality Plan Pre-Clinical Path Clinical Path Market Forecast Sales Path Gate 0 Decisions Gate 1 Decisions Gate 2 Decisions Gate 3 Decisions Tech, Regulatory, IP Approach Feasible Manageable Risk & Executional Gaps Gate 0 — Product Definition Acceptance / Concept Charter Medical Device Development Phases and Functional Activities Gate 1 — Feasibility Demonstrated / Initial Design Acceptance Gate 2 — Final Design Acceptance Gate 3 — Product Launch Acceptance / Launch Readiness PHASE 1 Demonstration / Concept & Feasibility Project Core Team Selection General Project Plan & Timeline Hire Specialists for Expertise Gaps Fundraising Activities Customer Input / VOC Customer Prototype Evaluation Business Plan & Literature Search Updates Early Concept Prototype Design & Build Prototype Evaluation Update Design Per Review & Analysis / Multiple Discipline Input Driven Initial Design Risk Analysis (dFMEA) Initiate & Maintain Design History File (DHF) IP Landscape Review & Review of Filings Initial Regulatory Strategy Initial Reimbursement Strategy Initiate DFM (Tooling, Fixturing) Initiate Quality Management System (QMS) / Document Control Pre-Clinical Tests Assemble SAB & MAB Survey Analysis Sales Plan Determine Endpoints & Variables Pre-clinical Data Analysis Value Proposition Viable & Sustainable Product Risks Acceptable Technical Feasibility Proven & Optimized Manufacturing & Value Chain Confidence PHASE 2 Design & Development / Verification & Validation Cross-Functional Project Management Budgeting / Fundraising Activities Customer Prototype Evaluation Meta Analysis White Paper Data Summary, Analysis White Paper, Publish Peer Review Papers Product Development & Test Design Verification & Validation Update Design per Review & Analysis / Multiple Discipline Input Driven Design Risk Analysis (dFMEA) Maintain DHF & Project Timeline Patent Review / Inlicense & Outlicense Review Regulatory Strategy Update Finalize / Pursue Reim- bursement Strategy Detailed Produc- tivity Analysis Initial Process FMEA (pFMEA) Supplier Collaboration Manufacturing & Process Engineering Begin Process IQ / OQ / PQ / PPQ Biocompatibility Testing (If Possible) Clinical Validation Plan Survey Analysis Literature & Data Meta Analysis Recruit Sales Team Commercialization Readiness Design Freeze Design Output Meets Targets Regulatory Submission, Testing Complete Risk Mitigation Confirmed PHASE 3 Final Validation / Product Launch Preparation Cross-Functional Project Management Business Develop- ment Budgeting or Fundraising Activities Product Branding Market Launch Plan / Forecast Meta Analysis White Paper Data Summary, Analysis White Paper, Publish Peer Review Papers DHF Completion dFMEA Update & Review Final Design & Documentation Release Final Patent Review with R&D Obtain Regulatory Clearances (FDA, CE, UL, etc.) Regulatory Submission Pursue Reimbursement Manufacturing / Operations Scale Up Full Process Qualification Finalize Process IQ / OQ / PQ / PPQ Physician Pre-Clinical Training, Biocompatibility Testing Clinical Validation Clinical Data Analysis Sales Training Final Validations Sales Launch, Business Launch Plan Adjust PHASE 4 Product Launch & Post-Launch Assessment Cross-Functional Project Management Physical Training & Continuous Sales Efforts Meta Analysis White Paper, Publish Peer Review Papers Sustaining Engineering / Product Improvements as Needed DCO Maintenance Support Release Patent Litigation Post-Market Surveillance / MDR Update Reimbursement as Needed Process Improvements as Needed Update Design Control Doc as Needed Quality Audits Physician Pre-Clinical Training Continued Clinical Validation Summary White Paper Reps Attend Cases 1 2 3 7 8 9 10 14 12 15 13 17 16 4 5 6 1) PRD = Product Requirements Document 2) Rapid Prototyping 3) Design For Manufacturability & Assembleability Design Documentation Quick CAD Layouts, Prelim. Engineering Specs CAD Models, Minimum Drawing Set, Engineering Specification “Looks-like / Works-like” Prototypes, Aesthetic Refinement, DFMA (3) (RP & Production Methods) Complete CAD Models & Drawing Set, Updated Engineering Spec, Other Design Files “Looks-Like / Works-Like / Made-like” Cosmetic Refinement, Pre-Production Units, Packaging, (Production Methods) Full Released Documentation Per ISO13485 Sketches, Renderings (Paper, Digital) Renderings, Size / Feature Mockups, Appearance Models (Hard Foam, RP (2) Methods) Industrial Design Order Tooling 114 Pleasant Street Southbridge, MA 01550 usa T 508 765 8100 www.optimum-tech.com © 2010 Optimum Technologies, Inc. TECHNOLOGIES Return to site www.opmum-tech.com

Upload: duongnhan

Post on 10-Jun-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Tasks / Functional

Groups

Cross-FunctionalManagement

Markets &Marketing

Writing and Publications

Research & Development

Legal / IP

Regulatory

Reimbursement

Manufacturing &Operations

Quality

Pre-Clinical

Clinical

Data and Statistics

Sales

Market Opportunity

Basis for Competition

PHASE 0 Evaluation /

Opportunity & Risk Analysis

Financial Review

Business Model Development

Market AnalysisCompetitive Assessment

“PRD” (1)

Business Plan & Presentations

Literature Search

Early Risk Assessment &

Concept Approach

Legal / IP Analysis, Clearance Opinion

Regulatory Path

Reimbursement Path

Manufacturing plan

Quality Plan

Pre-Clinical Path

Clinical Path

Market Forecast

Sales Path

Gate 0 Decisions Gate 1 Decisions Gate 2 Decisions Gate 3 Decisions

Tech, Regulatory, IP Approach Feasible

Manageable Risk & Executional Gaps

Gat

e 0

— Pr

oduc

t Def

initio

n Ac

cept

ance

/ Co

ncep

t Cha

rter

Medical Device Development Phases and Functional Activities

Gat

e 1

— F

easib

ility

Dem

onst

rate

d /

Initia

l Des

ign

Acce

ptan

ce

Gat

e 2

— Fin

al D

esig

n Ac

cept

ance

Gat

e 3

— Pr

oduc

t Lau

nch

Acce

ptan

ce /

Laun

ch R

eadi

ness

PHASE 1Demonstration /

Concept & Feasibility

Project Core TeamSelection General Project Plan & Timeline

Hire Specialists for Expertise Gaps Fundraising Activities

Customer Input / VOC Customer Prototype Evaluation

Business Plan & Literature Search Updates

Early Concept Prototype Design

& BuildPrototype Evaluation

Update Design Per Review &

Analysis / Multiple Discipline

Input DrivenInitial Design Risk Analysis

(dFMEA)

Initiate & Maintain Design History

File (DHF)

IP Landscape Review & Review of Filings

Initial Regulatory Strategy

Initial Reimbursement Strategy

Initiate DFM (Tooling, Fixturing)

Initiate Quality Management System (QMS) / Document Control

Pre-Clinical Tests

Assemble SAB & MAB

Survey Analysis

Sales Plan

Determine Endpoints & Variables

Pre-clinical Data Analysis

Value Proposition Viable &

SustainableProduct Risks Acceptable

Technical Feasibility Proven

& OptimizedManufacturing & Value Chain

Confidence

PHASE 2Design & Development /Verification & Validation

Cross-Functional Project Management

Budgeting / Fundraising Activities

Customer Prototype Evaluation

Meta Analysis White Paper

Data Summary, Analysis White Paper, Publish Peer Review Papers

Product Development

& Test

Design Verification &

ValidationUpdate Design per Review &

Analysis / Multiple

Discipline Input Driven

Design Risk Analysis(dFMEA)

Maintain DHF & Project Timeline

Patent Review / Inlicense & Outlicense Review

Regulatory Strategy Update

Finalize / Pursue Reim-bursement Strategy

Detailed Produc-tivity Analysis

Initial Process FMEA (pFMEA)

Supplier Collaboration

Manufacturing & Process

Engineering

Begin Process IQ / OQ / PQ / PPQ

Biocompatibility Testing (If Possible)

Clinical Validation Plan

Survey Analysis Literature & Data Meta Analysis

Recruit Sales Team

Commercialization Readiness

Design Freeze

Design Output Meets Targets

Regulatory Submission, Testing

CompleteRisk Mitigation

Confirmed

PHASE 3Final Validation / Product Launch

Preparation

Cross-Functional Project Management

Business Develop-ment

Budgeting or Fundraising Activities

Product Branding Market Launch Plan / Forecast

Meta Analysis White PaperData Summary, Analysis White Paper, Publish

Peer Review Papers

DHF Completion

dFMEA Update & Review

Final Design & Documentation

Release

Final Patent Review with R&D

Obtain Regulatory Clearances (FDA, CE, UL, etc.)

Regulatory Submission

Pursue Reimbursement

Manufacturing / Operations Scale Up

Full Process Qualification

Finalize Process IQ / OQ / PQ / PPQ

Physician Pre-Clinical Training, Biocompatibility Testing

Clinical Validation

Clinical Data Analysis

Sales Training

Final Validations

Sales Launch, Business Launch

Plan Adjust

PHASE 4Product Launch & Post-Launch

Assessment

Cross-Functional Project Management

Physical Training & Continuous Sales Efforts

Meta Analysis White Paper, Publish Peer Review Papers

Sustaining Engineering / Product Improvements as Needed

DCO Maintenance

Support Release

Patent Litigation

Post-Market Surveillance / MDR

Update Reimbursement as Needed

Process Improvements as Needed

Update Design Control Doc as Needed

Quality Audits

Physician Pre-Clinical Training

Continued Clinical Validation

Summary White Paper

Reps Attend Cases

1

2

3

789

10

14

12

15

13

17

16

4

5

6

1) PRD = Product Requirements Document 2) Rapid Prototyping 3) Design For Manufacturability & Assembleability

Design Documentation

Quick CAD Layouts, Prelim.

Engineering SpecsCAD Models, Minimum Drawing Set,

Engineering Specification

“Looks-like / Works-like” Prototypes, Aesthetic

Refinement, DFMA(3) (RP & Production Methods)

Complete CAD Models & Drawing Set, Updated Engineering Spec, Other

Design Files

“Looks-Like / Works-Like / Made-like” Cosmetic Refinement, Pre-Production Units,

Packaging, (Production Methods)

Full Released Documentation Per ISO13485

Sketches, Renderings

(Paper, Digital)Renderings, Size / Feature Mockups, Appearance

Models (Hard Foam, RP (2) Methods)Industrial Design

Order Tooling

114 Pleasant Street Southbridge, MA 01550 usa T 508 765 8100 www.optimum-tech.com

© 2010 Optimum Technologies, Inc.

TECHNOLOGIES

Return to site www.optimum-tech.com

CUT

Bind

ing