Page 1: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

2012 PNCWA Conference, Boise, Idaho

Retrofitting an Aeration Basin with Anoxic Zone to Reduce Operations Cost and Improve Performance

Ed Griffenberg, Operations Specialist HDR Engineering, Edmonds, WA

Page 2: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Case Study – Mount Vernon WWTP

•  Project Background

•  Retro!t Ideas

•  Model

•  Implementation

•  Reality Check

•  Design & Construction

•  Conclusion

Page 3: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Background

•  The City of Mount Vernon is located approximately half way between Everett and Bellingham in Washington State.

•  Largest community in Skagit County.

•  Draper Valley Farm is the largest industrial customer (15-20% of loading).

Page 4: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Mount Vernon Wastewater Treatment Plant - Before Upgrade

Page 5: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Wastewater Treatment Plant

•  Provides secondary treatment utilizing the activated sludge process. This process is more "exible than others (trickling !lters for example) in adapting to changes, such as nutrient removal.

•  Originally designed for TSS and BOD removal only

•  Began partial nitrifying in 2001

Page 6: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Why Nitrify?

•  Required by new permit

•  Difficult to avoid in summer

•  Develop data for plant upgrade design

•  Operator interest

Page 7: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Nitrogen Transformations

Nitrification

Organic N (Growth)

Nitrogen Gas Denitrification

O2

O2 Organic Carbon

Decomposition

Organic N (Cells)

Organic N

Ammonia

Nitrite

Nitrate

Assimilation

Page 8: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Wastewater Treatment Plant Capacity

•  Average day design "ow of 5.6 MGD

•  Peak design "ow of 12.0 MGD

Page 9: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Future Expansions Increase Plant Capacity from 10.8 MGD to 16.4 MGD

Page 10: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Aeration Basin Influent

Parameter Unit Summer

Flow" MGD" 2.63"

COD" mg/L" 265"

BOD" mg/L" 122"

TSS" mg/L" 75"

TKN" mg/L" 45"

NH3" mg/L" 30-45"

Temperature" oC" 20"

Page 11: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

NPDES Permit Effluent Average Monthly Limits

•  Must try to remove Ammonia from July 1st through October 31st.

•  30 mg/L of BOD5

•  30 mg/L of TSS

•  200 Fecal Coliform

Page 12: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Activated Sludge Process

Page 13: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Original Design

.

AB 2 Aerobic

AB 3 Aerobic

RAS Pri Eff

Page 14: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Previous Summer Nitrification Problems

•  Floating sludge in clari!ers

•  Trying to nitrify to just meet permit limits resulted in nitrite lock

•  Nitrite lock - disinfection problems

•  Insufficient alkalinity results in low effluent pH

Page 15: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Denitrification in Wrong Place

Page 16: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Attempt to Minimize Floating Sludge

•  Increase RAS to the maximum to minimize clari!er sludge detention time was not effective

Page 17: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Why Did Sludge Float

•  Nitri!cation converts ammonia to nitrate

•  Without oxygen in the secondary clari!ers, nitrates will denitrify producing nitrogen gas

•  Gas bubbles "oat the sludge blanket

Page 18: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Nitrogen Transformations

Denitrification

Organic N (Growth)

Nitrogen Gas

Assimilation

Nitr

ifica

tion

O Organic Carbon

Decomposition

Organic N (Cells)

Organic N

Ammonia

Nitrite

Nitrate

Page 19: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Solving the Problem

•  What can be done to prevent "oating sludge?

•  Prevent denitri!cation in secondary clari!er

•  Denitrify somewhere else before nitrate enters clari!er

Page 20: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Solving the Problem

•  How to remove the nitrate?

•  Create an anoxic zone in the activated sludge basins, pump nitrate rich MLSS to the anoxic zone, provide a carbon source and the biomass will do the rest.

Page 21: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Modified Ludzack Ettinger (MLE) System

Page 22: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Original Design

.

AB 2 Aerobic

AB 3 Aerobic

RAS Pri Eff

Page 23: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Anoxic Basin Retrofit

.

Mixed Liquor Recycle

AB 1 WAS

Storage

AB 2 Aerobic

AB 3 Aerobic

AB 4 Anoxic

Mixer

RAS Pri Eff

Page 24: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Will the Idea Work?

•  Before modi!cations are made, run computer model to determine feasibility – BioWin Model

Influent

Filtrate Return

EffluentReactor 1 Reactor 2 Anoxic

Waste Activated Sludge

Aerobic Aerobic

Page 25: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Base Conditions

•  100% Mixed Liquor Recycle (MLR) rate and 50% RAS rate

•  Initial reactor D.O. at 2 mg/L (to simulate aeration by screw pumps)

•  Sufficient aeration capacity to meet oxygen demand in aerobic reactors

Page 26: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Base Run Output

•  Complete nitri!cation (98% ammonia removal)

•  50% nitrate removal was slightly lower than textbook denitri!cation performance

•  High effluent nitrate (17 mg/l) due to high in"uent ammonia (36 mg/l)

Page 27: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Denitrification vs. Recycle

0%

20%

40%

60%

80%

100%

0 2 4 6 8 10

Recycle Ratio (RAS + MLSS)

RAS = 0.5 Q

IR = 1 Q

Recycle Ratio = 1.5 Q

Page 28: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Additional Model Observations

•  200% MLR rate resulted in same effluent nitrate concentration

•  Modeling a higher in"uent BOD resulted in much lower effluent nitrate

•  Results indicate actual BOD/TKN ratio is too low to achieve theoretical denitri!cation removal at higher MLR rates

Page 29: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Modeling Conclusions

•  MLE mode will: •  Recover alkalinity consumed in nitri!cation •  Reduce oxygen demand •  Result in effluent nitrate 50% lower than operating without

denitri!cation •  Lower effluent nitrate will result in less potential for "oating sludge

in clari!er •  High in"uent ammonia relative to in"uent BOD results in lower

denitri!cation rate •  Thus – proceed with implementation!

Page 30: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Economic Retrofit

•  Use spare vertical turbine pump

•  Use existing basins

•  Purchase Flygt submersible mixer

•  Equipment/piping installed by plant staff

•  Modi!cations completed in June 2003

RESULT – Minimal cost modi!cation

Page 31: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

MLR Pump

Page 32: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Anoxic Basin Mixer

Page 33: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Reality Check

•  Additional sampling and analysis conducted

•  Actual in"uent parameters used in additional model runs

•  Compare real life performance to model prediction

Page 34: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Nitrification Performance

Nitrification Performance

0%

20%

40%

60%

80%

100%

120%

0 10 20 30 40 50

Influent NH3 (mg/L)

% R

emo

val

Actual % Removal Stable Actual % Removal Unstable Model % Removal

Page 35: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Influent & Effluent NH3

0

5

10

15

20

25

0 10 20 30 40 50

Influent NH3 (mg/L)

Eff

luen

t N

H3

(mg

/L)

Actual NH3 Stable Actual NH3 Unstable Model NH3

Page 36: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Comparison of Nitrification

•  Real life data indicates unstable nitri!cation at in"uent ammonia level higher than approximately 34 mg/L

•  Computer model predicts complete nitri!cation for the same range of in"uent ammonia concentrations

Page 37: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Potential Reason

•  Plant staff reported occasional difficulty maintaining sufficient D.O. (2 mg/L) in !rst aeration basin. Model assumes sufficient aeration at all times

•  Implication – further work required to assess aeration capacity and !ne tune controls

Page 38: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Denitrification Performance

0%

20%

40%

60%

80%

100%

0.0 10.0 20.0 30.0 40.0 50.0

Nitrate Available From Nitrification and Influent (mg/L)

% R

emo

val

Actual % Removal Model % Removal

Page 39: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Influent & Effluent Nitrate

0

5

10

15

20

25

0.0 10.0 20.0 30.0 40.0 50.0

Nitrate Available From Nitrification and Influent (mg/L)

Eff

luen

t N

itra

te (

mg

/L)

Actual Nitrate Model Nitrate

Page 40: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Real Life vs. Model - Impact of BOD/TKN Ratio

y = 0.1975x

R2 = 0.8616

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00

BOD/TKN Ratio

% R

emo

val

Model % Removal Actual % Removal Linear (Model % Removal)

Page 41: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Comparison of Denitrification

•  Real life data indicates 80% nitrate removal for BOD/TKN ratio from 2.5 to 3.8.

•  Actual nitrate removal meets theoretical maximum value even though BOD/TKN ratio is too low (< 4.0).

•  Hypothesis – model kinetic parameters based on domestic wastewater. Industrial contribution (23% of plant "ow) may change dynamics.

Page 42: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Trial Outcome

•  Plant meets effluent permit limits and nitrogen loading was reduced to improve water quality

•  Clari!er "oating sludge problem solved

•  Good data for plant upgrade generated (additional data needed to fully calibrate model)

•  Plant staff enjoyed modifying process

Page 43: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Other Insights

•  Side stream treatment of the dewatering !ltrate may be required to reduce ammonia loading on the aeration basins.

•  Basic nitrogen removal, to 8 to 10 mg/L,  doesn’t necessarily need to involve massive investment in capital facilities. 

Page 44: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Design & Construction Services

Page 45: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Future Expansions Increase Plant Capacity from 10.8 MGD to 16.4 MGD

Page 46: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

NDN Flow Pattern

Page 47: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

New Process for Old Basins

To 2nd

RAS PE

ML Recycle

AB-1B

AB-1A

Oxic Basin Anoxic

Page 48: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Design Criteria

Constituent Units Annual Average

Max Month Wet Weather

Max Hour Wet Weather

Flow (BOD mode) mgd 9.0 15.0 22.0

Flow (nitri!cation mode) mgd 4.6 7.6 22.0

BOD (BOD mode) lb/day 13,600 17,300 N/A

mg/l 181 138 N/A

BOD (nitri!cation mode)

lb/day 7,000 8,500 N/A

mg/l 182 134 N/A

Ammonia (nitri!cation mode)

lb/day 800 1,000 N/A

mg/l 20.8

15.8 N/A

Page 49: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

How’s it working

Month 2012

Average Flow MGD

Average TSS (mg/l)

Average BOD (mg/l)

Average NH3-N / NO3 (mg/l)

BOD Mode

Feb 5.1 7 5 20.0

March 5.3 6 5 23.9

April 4.5 15 9 30.3

May 4.4 4 9 20.0

Nitri!cation Mode

July 3. 8 7 16 4.6/6.7

August 2.8 6 13 0.8/0.8

September 2.6 7 12 1.8/2.5

October 2.5 9 12 2.2/9.6

Page 50: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Process Control Activities

•  NH3/NO3 monitoring in each basin

•  Adjustments to D.O., wasting rate, or caustic rate.

•  Tight pH control with pH probe.

•  Dewatering controls

•  RAS and MLR rate controls

•  Seasonal BNR/BOD mode

Page 51: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

How’s it working

•  Other Observations

•  Side stream treatment not used in AB-1A

•  Additional mixer placed in AB-1A to increase size of anoxic zone

•  Resulted in a decrease of nitrate and thus of denitri!cation in the secondary clari!er

•  SVI dropped from 300 to 180 in 30 day and then to 80 after an additional 30 days

•  Filament growth was reduced to almost nothing

Page 52: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

How’s it working

Oxic Basin

AB-1B Anoxic

AB-1A Anoxic

RAS + ML + PE

Page 53: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

How’s it working

•  By using our skills, the HDR/Mount Vernon team was successful in helping Mount Vernon develop and implement low-cost process modi!cations that improved plant operation, and achieved a secondary bene!t of improved water quality.

Page 54: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

Acknowledgements

•  Gary Duranceau – WWTP Superintendent

•  Andrew Denham– Process Control/Lab

•  Ray Pickens – Electrical Modi!cation

•  Ron Eastman – Mechanical Modi!cation

•  Dr. JB Neethling – BioWin Modeler

•  Bob Bower – Operations Specialist

Page 55: Retrofitting an Aeration Basin with Anoxic Zone to Reduce ......• Draper Valley Farm is the largest industrial customer (15-20% of ... need to involve massive investment in capital

2012 PNCWA Conference, Boise, Idaho

Retrofitting an Aeration Basin with Anoxic Zone to Reduce Operations Cost and Improve Performance

Ed Griffenberg, Operations Specialist HDR Engineering, Edmonds, WA