retail loss prevention summit v1.0

15
Established 80,000 secure communications solu Privately owned, no debt or external inve In house development, design and su Manufactured in t LPS1277 issue 3, EN50136, EN54-21, CPD WebWay International

Upload: chriscarterbrennan01

Post on 30-May-2015

527 views

Category:

Documents


0 download

TRANSCRIPT

  • 1. WebWay InternationalEstablished 200080,000 secure communications solutions Privately owned, no debt or external investorsIn house development, design and support Manufactured in the UK LPS1277 issue 3, EN50136, EN54-21, CPD, EMC

2. Reduce costs, enhance security How to save money and improve efficiency The cost of alarm signalling and strategies to save Mitigating alarm signalling risks withstandards compliance Chris Carter BrennanDirector WebWayOne Ltd September 2011How digital signalling improves operationalefficiency Migrating to digital signalling 3. Monitored events and their operational impact IncidentsConfirmed Emergency alarmsresponse Catastrophicsystem failuresAnalogue communicationsAlarm systemfaults and errorsChoice of Unscheduled technology Unconfirmed key holder or alarms engineering responseNetwork faultsand Digital performanceissues communications MaintenanceScheduledvisitsengineering visitReduce costs, not security 4. What are the costs of choosing analogue? Reduce costs, reduce security 5. Save time, money and enhance your business Reduce costs, enhance security 6. Mitigating risk through standards complianceTransmit alarms quickly,receive whatyou sendAlarms combined with faultsConfirmed EmergencyalarmconditionsresponseDetectnetwork failureor performance dropDetect hardwarefailure Reduce costs, enhance security 7. How to specify for highest efficiency and securityIntruder alarm panel Select Grade 2 or 3 with one or two warning devices Ensure system supports SIA protocol alarms Ensure systems supports remote servicingLocal and remote maintenance 1 or 2 visits per year 1 or more remote visits per yearNetwork monitoringOBJECTIVES Reduce communications costs Request LPS1277 Issue 3 compliant network monitoring Reduce business disruption Improve securityCommunications technology Improve reliability Select corporate network with GPRS backupAlarm monitoring Request SIA protocol alarms (zone, alarm type, bespoke) Determine alarms requiring key holder response Report single network fault events at store open (DD243) Determine alarms required in reports Request connection availability statistics Determine procedures for remediating network faults Reduce costs, not security 8. WebWay IP/GPRS Click image for hardware tour 3276 Approved to LPS1277 I&HAS ATS5, Fire type 1 and CPD 8 4Fixed line and wireless communicationsStepped up polling 1 5Catastrophic failure, 3.5 minutes 1 Ethernet - IP (DHCP or fixed)Roaming SIM 2 GPRS module and roaming SIMEncryption 3 Display & switchesSIA alarms and UDL 4 Serial data interfaces 5 Power, inputs & outputsIntegration for CCTV, EAS, BMS, People Counters 6 Expansion for dial capture, audio etcOptional PSTN tertiary path 7 Expansion for PSTN, serial data etc 8 Event log, flash, integration software Systems Command Centre Remote Manager Architecture 9. WebWay Command Centre Estate Status 1Real time status1 3 2Real time activity 3Real time sites in fault2 4 4Real time sites with availability trouble 5Site list5 6786Duration of fault with type 7WebWay trouble ticket number 8Estate, address etcBack Users Estates Commissioning Alarms Availability PaveWay 10. WebWay Command Centre Commissioning1Communications overview 12 3 2Ethernet operation3GPRS operation4Polling set up5Alarm panel connectivity 45 66Connection performance overview Back Users Estates Commissioning Alarms Availability PaveWay 11. WebWay Command Centre Availability1Site identification from AMS2Real time status3Number of ATS fails in period 1 2 3 4 56 7 8 4ATS availability for period5Number of IP fails passed to AMS6IP availability for period7Number of GPRS fails passed to AMS8GPRS availability for period9Reporting threshold configuration 9 Back Users Estates Commissioning AlarmsAvailability PaveWay 12. WebWay Command Centre Users1User defined by email address2Authorised GateWay3Restricted permissions4Restricted estates5Login1 2 2345 Back Users Estates Commissioning AlarmsAvailability PaveWay 13. Save time, money and enhance your business with digital security signallingMitigate risk Protect againstReducethrough old technologybusinessperformance price increases interruptionreports SecureUse standardstransmission Manageto validate and monitoring efficiently solutions Chris Carter Brennan, Director, WebWayOne Ltd 14. WebWay Command Centre Estates1Root estate2Estate / sub estate structure1 2 Back Users Estates Commissioning Alarms AvailabilityPaveWay 15. WebWay Command Centre Alarms1Event audit trail 1 2 1 23 2SIA alarm3Unset, user etc 4 563 Back Users Estates Commissioning Alarms Availability PaveWay