retail for lease - loopnet€¦ · design build system. z 2-way communication device conected to...

6
RETAIL FOR LEASE 7544 DUBLIN BOULEVARD DUBLIN, CALIFORNIA

Upload: others

Post on 13-Dec-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

R E T A I L F O R L E A S E7 5 4 4 D U B L I N B O U L E VA R DD U B L I N , C A L I F O R N I A

Page 2: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

1-mile 3-mile 5-mile

POPULATION 11,425 78,090 187,701

AVERAGE HH INCOME $126,303 $148,230 $160,656

DAYTIME POPULATION 32,218 96,249 209,201

F E A T U R E S

• ±10,332 SF OF RETAIL SPACE AVAILABLE

y CONVENIENT ACCESS TO AND FROM I-580 AND I-680

y CENTRALLY LOCATED IN DUBLIN RETAIL TRADE AREA

yWALKING DISTANCE TO BART STATION

y LOCATED AT THE SIGNALIZED INTERSECTION OF

DUBLIN BOULEVARD AND GOLDEN DATE DRIVE

y 313 APARTMENT UNITS ABOVE

y FLEXIBLE DEMISING OPTIONS

y 97 DEDICATED RETAIL PARKING SPACES

2017 DEMOGRAPHICS

TRAFFIC COUNTS

DUBLIN BOULEVARD - 28,000 ADT

INTERSTATE 680 - 167,000 ADT

INTERSTATE 580 - 214,000 ADT

R E T A I L F O R L E A S E

Page 3: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

S I T E P L A N

SHEET NOTES

GENERAL NO

TES

FIRE DEPARTMENT KEY-BO

X LOCATIO

N

DESIGN/BUILD O

VERHEAD COILING

SECURITY GATE

WITH KEYED & FO

B-CONTRO

LLED ACCESS. GATE

SHALL MEET REQ

.S OF CFC SECTIO

N 1008.1.4.4.

DESIGN/BUILD STL HO

T-DIPPED GALV. SECURITY SITE

GATE BY G

.C. PER DESIGN INTENT M

OUNTED O

N STRUCTURALLY ISO

LATED TUBE STL, SEE 6/A8.40

CONCRETE SHEAR W

ALL, S.S.D. SEE A10.00 FOR W

ALL ASSEM

BLIES

CONCRETE W

HEEL STOP

43" STEEL GUARD RAIL

STANDARD PARKING SPACE, TYP. (9'-0" x 20'-0")

COM

PACT PARKING SPACE, TYP. (8'-0" x 17'-0")

TYPICAL ACCESSIBLE PARKING SPACE PER A0.5

VAN-ACCESSIBLE PARKING SPACE PER A0.5

ADA STRIPING

FLOO

R/AREA DRAINS, S.P.D., S.S.D.

CONCRETE CO

LUMN, S.S.D.

HOSE BIB. NO

N-REMO

VABLE BACKFLOW

PREVENTION

DEVICE SHALL BE INSTALLED ON ALL HO

SE BIBS AND PO

TABLE WATER O

UTLETS WITH HO

SE ATTACHM

ENTS. CPC 603.5.7

TRASH/RECYCLING BIN, 3'-0" W

, 3'-0" H, 6'-0" L. G.C. TO

VERIFY SIZE W

ITH LOCAL W

ASTE MANAG

EMENT

COM

PANY PRIOR TO

PURCHASE

3"H x 8"W CO

NC. CURB FOR DUM

PSTER WHEELSTO

P

TRASH CHUTE DISCHARGE W

/FUSIBLE LINK

TRASH CHUTE: UL 90 MIN "B" LABEL; TR

ASH C

HU

TE IN

TAKE DO

OR

S SHALL BE AC

TIVATED BY

ELECTR

ICALLY O

R PN

EUM

ATICALLY C

ON

TRO

LLED

PUSH

BUTTO

N, AN

D SH

ALL BE FULLY C

OM

PLIANT

WITH

ALL ADA R

EQU

IREM

ENTS.

TRASH

CH

UTE VEN

T

RAIN

WATER

LEADER

TO SPLASH

BLOC

K BELOW

10" SEISMIC G

AP, SEE 1 & 2/A8.14

FIRE SPR

INKLER

RISER

IN 1-H

R R

ATED R

ECESSED

C

ABINET: LAR

SEN FS VC

2626-R )W

HEN

NO

T IN A

STAIR). D

ESIGN

/BUILD

ENG

INEER

TO LO

CATE. W

HERE RISER DO

ES NOT O

CCUR WITHIN A STAIR

ENCLOSURE, PRO

VIDE FIRE-CAULKING AT EACH

FLOO

R PENETRATION.

INDICATES DROPPED G

WB CLG

W/ RECESSED "CAN"

LIGHTING

, SEE BLDG RCPS O

N SHEETS A6.1 & A6.2.

DASHED LINE INDICATES DROPPED G

WB CLG

W/

RECESSED "CAN" LIGHTING

AND SCORED 2' X 2'

CONCRETE AT FLO

OR

USPS-APPROVED RESIDENT M

AILBOXES W

/ REACH RANG

E BETWEEN 28" A.F.F. AND 54" A.F.F. O

NE PARCEL BO

X PER 10 RESIDENTS TO BE INCLUDED

OUTLINE O

F 2'-0" x 7'-0" GURNEY

VEHICULAR CLEARANCE BAR LOCATIO

N

2 HOUR FIRE RATED AREA SEPARATIO

N WALL - SEE

SHEET A10.0.

LINE OF LEVEL ABO

VE

A. DIMENSIO

NS ARE TO FACE O

F STUD, CONCRETE O

R FO

UNDATION W

ALL, TYP. U.O.N.

B. SEE A0.3 AND A0.4 FOR BUILDING

AREA CALCULATIONS.

C. SEE A0.6 FOR ACCESSIBILITY AND ADAPTABILITY

REQUIREM

ENTS.

D. SEE A0.7 - A0.11 FOR EG

RESS CALCS. AND DIAGRAM

S.

E. UNIT PLANS SHOW

N HERE ARE DIAGRAM

ATIC REFER TO 1/4"

UNIT PLANS AND ENLARGED PLANS FO

R ADDITIONAL

INFORM

ATION NO

T SHOW

N HERE.

F. SEE SHEET A10.0 FOR W

ALL TYPE SCHEDULE AND TYPICAL ASSEM

BLIES.

G. SEE LANDSCAPE DRAW

INGS FO

R INFORM

ATION REG

ARDING

THE GRADING

OF ALL EXTERIO

R AREAS.

H. CIVIL ELEV. 340.2' = ARCHITECTURAL ELEV. 0'-0".

I. ALL EXTERIOR W

OO

D WALLS TO

RECEIVE PLYWD SHEATHING

.

J. REFER TO STAIR DRAW

INGS FO

R INFORM

ATION NO

T SHOW

N HERE.

K. G.C. TO

COO

RDINATE MECH. AND PLUM

B. VENTS AS PERM

ITTED BY CODES TO

MINIM

IZE ROO

F PENETRATIONS.

L. G.C. TO

COO

RD. AND INSTALL VENTING FO

R ALL CONCEALED

ROO

F AREAS AND OTHER EXTR W

OO

D FRAMED VO

IDS.

M. ALL G

SM FLASHING

SHALL BE BONDERIZED AND PAINTED O

R RECEIVE CO

ATINGS TO

MATCH SURRO

UNDING M

ATERIALS.

N. ROO

F SLOPES NO

TED ARE MINIM

UMS. RO

OF SLO

PES OF

CRICKETS SHOW

N DIAGRAM

MATICALLY O

N ROO

F PLANS MAY

EXCEED 3/8"/FT TO ACHIEVE PRO

PER ROO

F DRAINAGE AS

SHOW

N.

O. G

.C. TO INCLUDE AND CO

ORDINATE RO

OF CRICKETS IN FIELD

FOR PRO

PER DRAINAGE IN ACCO

RDANCE WITH CO

DE AND RO

OF M

ANUFACTURER'S WARRANTY.

P. U.O.N., TYPICAL W

ALL TYPES AT FLOO

RS BELOW

PODIUM

SLAB TO

BE: 1. EXTERIO

R WALLS: TYPE B. SEE EXTERIO

RELEVATIO

NS FO

R FINISH TYPES AND LOCATIO

NS. 2. INTERIO

R WALLS: TYPE P1.

3. INTERIOR 2-HR RATED W

ALLS: TYPE R.U.O

.N., TYPICAL WALL TYPES AT FLO

ORS ABO

VE PODIUM

SLAB TO

BE: 1. EXTERIO

R BUILDING W

ALLS INCLUDING W

ALLS AT CO

URTYARDS: TYPE C1. SEE EXTERIOR ELEVATIO

NS FOR

FINISH TYPES AND LOCATIO

NS.2 . INTERIO

R CORRIDO

R WALLS: TYPE E.

3. INTERIOR STAIR/ELEVATO

R SHAFT WALLS: TYPE D2 AT

CORRIDO

R / TYPE H2 ADJACENT TO DW

ELLING UNIT

4. UNIT DEMISING

WALLS: TYPE H1.

5. 2-HR MECHANICAL SHAFT W

ALLS: K.6 . INTERIO

R UNIT WALLS: TYPE G

OR D1.

7. FIRE WALLS TO

BE TYPE "J" U.O.N.

Q. W

HERE WALL FINISHES DO

NOT ALIG

N DUE TO CHANG

E IN W

ALL TYPE, GC TO

PROVIDE BACKING

TO ENSURE A FLUSH

FINISH TRANSITION

R. SEE A8 SERIES SHEETS FOR TYP. RO

OF PIPE PENETRATIO

N & W

ATERPROO

FING INFO

RMATIO

N

S. U.O.N., ALL EXTERIO

R DWELLING

UNIT DECKS AND EXPOSED

CONCRETE SURFACES TO

RECEIVE WATERPRO

OF TRAFFIC

COATING

PER SPECIFICATIONS. SEE ALSO

LANDSCAPE PLANS FO

R EXTERIOR AREAS THAT ARE TO

RECEIVE PAVERS.

T. REINFORCED 15-M

IL VAPOR BARRIER TO

BE PROVIDED

UNDER SLAB, TYP. SEE BE DRAWING

FOR EXCEPTIO

NS.

U. STANDPIPE LOCATIO

NS SHOW

N ON PLANS ARE

DIAGRAM

MATIC; FIRE SPRINKLER SUBCO

NTRACTOR TO

PRO

VIDE STANDPIPE LOCATIO

N PLAN FOR REVIEW

BY ALAM

EDA COUNTY FIRE DEPARTM

ENT. PER CBC 905.4, CLASS I STANDPIPE HO

SE CONNECTIO

NS SHALL BE PROVIDED IN THE

FOLLO

WING

LOCATIO

NS:1. IN EVERY STAIRW

AY AT THE INTERMEDIATE LANDING

LEVEL2. O

N EACH SIDE OF HO

RIZONTAL EXITS

3. AT EACH EXIT PASSAGEW

AY, AT THE ENTRANCE FROM

THE EXIT PASSAG

EWAY TO

OTHER BUILDING

AREAS4. W

HERE THE MO

ST REMO

TE PORTIO

N OF A FLO

OR IS M

ORE

THAN 150' FROM

A HOSE CO

NNECTION

5. WHERE THE RO

OF HAS A SLO

PE LESS THAN 4 UNITS

VERTICAL IN 12 UNITS HORIZO

NTAL, A HOSE CO

NECTION

SHALL BE LO

CATED TO SERVE THE RO

OF O

R AT THE

HIGHEST LANDING

OF A STAIRW

AY WITH STAIR ACCESS TO

THE ROO

F.

V. FOR STRUCTURAL M

EMBERS REQ

UIRING INDIVIDUAL FIRE

PROTECTIO

N, SEE STRUCTURAL DRAWING

S. SEE ALSO 1/A9.20.

W. EXTERIO

R WALLS O

F VERTICAL EXIT ENCLOSURE THAT ARE

LOCATED AT AN ANG

LE OF LESS THAN 180º AND W

ITHIN 10 FEET HO

RIZONTALLY O

F A NON-RATED W

ALL OR UNPRO

TECTED O

PENING SHALL HAVE A FIRE-RESISTIVE RATING

OF NO

T LESS THAN 1-HR. O

PENINGS W

ITHIN SUCH EXTERIOR W

ALLS SHALL BE PRO

TECTED BY OPENING

PROTECTIVES HAVING

A FIRE PRO

TECTION RATING

OF NO

T LESS THAN 3/4 HOUR. THIS

CONSTRUCTIO

N SHALL EXTEND VERTICALLY FROM

THE G

ROUND TO

A POINT 10' ABO

VE THE TOPM

OST LANDING

OF THE

STAIRWAY O

R TO THE RO

OF LINE, W

HICHEVER IS LOW

ER PER CBC 1022.7.

X. FIRE WALL SHALL TERM

INATE AT A POINT NO

T LESS THAN 30" ABO

VE THE LOW

ER ROO

F LEVEL. THE EXTERIOR W

ALL ABO

VE THE LOW

ER ROO

F SHALL NOT HAVE LESS THAN A 1-HR

FIRE-RESISTANCE-RATED CONSTRUCTIO

N FROM

BOTH SIDES

WITH O

PENINGS PRO

TECTED BY FIRE ASSEMBLIES HAVE A A

FIRE PROTECTIO

N RATING O

F NOT LESS THAN 3/4 HR FO

R A MIN

MINIM

UM HEIG

HT OF 15 FEET PER SECTIO

N 706.6.1.

Y. G.C. SHALL PRO

VIDE EMERG

ENCY ALARM/W

ARNING SYSTEM

CAPABLE O

F ACTIVATING A M

EANS OF W

ARNING FO

R THE HEARING

IMPAIRED PER CBC 1007.11 AS PART O

F THE DESIGN

BUILD SYSTEM.

Z. 2-WAY CO

MM

UNICATION DEVICE CO

NECTED TO CENTRAL

CONTRO

L POINT AND SPECIFIC DIRECTIO

NS RELATED TO THE

USE OF EM

ERGENCY CO

MM

UNICATIONS SYSTEM

TO BE

PROVIDED AT EACH ELEVATO

R LANDING PER CBC 1007.8.1.

AA. JOINTS M

ADE IN OR BETW

EEN FIRE BARRIERS, AND JOINTS

MADE AT THE INTERSECTIO

N OF FIRE BARRIERS W

ITH UNDERSIDE O

F FIRE-RESISTANCE RATED FLOO

R OR RO

OF

SHEATHING, SLAB, O

R DECK ABOVE, AND THE EXTERIO

R VERTICAL W

ALL INTERSECTIONSHALL CO

MPLY W

ITH ALL REQ

UIRMENTS O

F CBC 715. THE VOIDS CREATED AT THE

INTERSECTION O

F A FIRE BARRIER AND A NO

N-FIRE-RESISTANCE-RATED ROO

F ASSEMBLY SHALL BE

FILLED PER REQUIRM

ENTS OF CBC 707.9.

BB. SMO

KE DAMPERS SHALL BE PRO

VIDED AT ALL DUCT PENETRATIO

NS OF O

F 1-HR FIRE RATED CORRIDO

R WALLS AND

CEILINGS ASSEM

BLIES PER CBC 714.4.1.2.

CC. GC IS TO

INCLUDE SPRINKLER HEADS AT ALL FURRED OUT

VOIDS AT EXTERIO

R WALLS.

SHEET NOTES, CO

NTINUEDLINE O

F ROO

F BELOW

STRUCTURAL DRAIN TO PIPE - S.P.D.

GSM

OVERLAND RELEASE SCUPPER

ROO

F DRAIN WITH O

VERFLOW

TO RAINW

ATER LEADER, SEE DETAIL 7/A8.00

ROO

F VENT, SEE DETAIL 12/A8.00

2-HR VENT SHAFT TO RO

OF - S.M

.D.

PARAPET WALL, SEE ELEVATIO

NS

ELEVATOR PENTHO

USE WITH 24" x 24" G

SM

HOISTW

AY VENT

ROO

FTOP HVAC EQ

UIPMENT M

OUNTED O

N PAD ADJACENT TO

PARAPET WALL, SEE 9&10/A8.00

WHITE TPO

ROO

FING

SEMI-RECESSED FIRE EXTING

UISHER & CABINET: LARSEN M

ODEL 2712 ALUM

INUM FRAM

E WITH G

LASS W

INDOW

OR APP'D EQ

. USE SURFACE-MTD CABINET

AT CONCRETE &CM

U WALLS. EXTING

UISHER TYPE 2A10BC. G

.C. TO INCLUDE IN PRICE (20) EXTRA FIRE

EXTINGUISHERSAND CABINETS TO

BE LOCATED PER

DIRECTION O

F LOCAL FIRE DEPARTM

ENT. WHERE

WALLS ARE REQ

UIRED TO HAVE A FIRE-RESISTANCE

RATING, FIXTURES SHALL BE INSTALLED SUCH THAT

THE REQUIRED FIRE-RESISTANCE SHALL NO

T BE REDUCED.SURFACE M

TD FIRE EXTINGUISHER AT CO

NCRETE

ROO

F PROTECTIO

N WALK PAD

COUNTERTO

P WITH G

ROM

METS O

VER CABINET FOR

TRASH / RECYCLING

HORIZO

NTAL EXIT AND STANDPIPES PER CBC 1025, CBC 905.4 AND CFC 702.3

36" HIGH HO

T-DIP GALVANIZED, PAINTED HANDRAIL

WITH 12" TO

P EXTENSION & 24" BO

TTOM

EXTENSION

GC SHALL PAINT SO

UTH FACADE OF (E) BUILDING

LINE OF SLAB EDG

E BELOW

MECHANICAL W

ALL PENETRATION - S.M

.D. FOR SIZE

AND COVER TYPE. ALL DUCT AND AIR TRANSFER

OPENING

S MUST CO

MPLY W

ITH FIRE PROTECTIO

N REQ

UIRMENTS O

F CBC 714.1.1.

HATCHING INDICATES 4'-0" ZO

NE MEASURED FRO

M

CENTERLINE OF 2-HR FIRE W

ALL WHERE SUCH W

ALL IS PERM

ITTED TO TERM

INATE AT THE UNDERSIDE OF

THE ROO

F SHEATHING IN W

HICH THERE ARE NO

OPENING

S IN THE ROO

F WITHIN 4 FEET O

F THE FIRE W

ALL, THE ROO

F IS COVERED W

ITH A MINIM

UM

CLASS B ROO

F COVERING

AND THE ROO

F SHEATHING

IS CONSTRUCTED O

F FIRE-RETARDANT-TREATED PLYW

OO

D FOR A M

INIMUM

DISTANCE OF 4 FEET O

N BO

TH SIDES OF THE FIRE W

ALL PER CBC 706.6, EXCEPTIO

N 4.

STACKING BICYCLE STO

RAGE SYSTEM

BY SARIS OR

APPROVED EQ

UAL

INDUSTRIAL DOUBLE W

ASH SINK

GAS M

ITIGATIO

N RISER - SEE VAPOR M

ITIGATIO

N DRAW

INGS, LISTED IN SHEET INDEX 1/A0.0

SECURITY PHONE PER DM

C 7.32.300; SEC 1010(K)(3)

SUMP W

ITH DRAIN, S.P.D.

60" L, 44" W, 60" H CEILING

-MO

UNTED FAN, S.M.D,

S.S.D.

DESIGN/BUILD FULL-HEIG

HT PAINTED HOT-DIP

GALVANIZED STEEL PICKET SECURITY FENCE

TRUNCATED DOM

ES

DROP CAP, S.S.D.

INFILL OPENING

WITH CM

U WALL 43" A.F.F. CO

NT ALO

NG RAM

P. DESIGN/BUILD HO

T-DIPPED G

ALVANIZED DECORATIVE M

TL RAILING INFRO

NT PER ELEVATIO

NS, PAINTED BLACK, SEE A8.40.

GARAG

E EXHAUST VENT, CONTINUO

US THROUG

H TO

ROO

F, S.M.D.

SUN SHADE

DESIGN/BUILD HO

T-DIPPED GALVANIZED STEEL

CANOPY, PAINTED BLACK, SEE 3/A8.41

TRENCH DRAIN

WALL-M

OUNTED BIKE RACK

SOIL BENEATH P.T. SLAB, S.S.D.

CAR CHARGER STATIO

N-TYPE I

CAR CHARGER STATIO

N-TYPE II

ASSUMED LO

CATION O

F FUTURE DEMISING

WALL

PARTIAL-HEIGHT W

ALL WITH RAILING

OUTLINE O

F MECHANICAL VENT SHAFT ABO

VE WITH

3-HR ENCLOSURE AT BO

TTOM

PER CBC 713.11. (SHAFT THAT DO

ES NOT EXTEND TO

THE UNDERSIDE O

F THE ROO

F SHEATHING, DECK O

R SLAB SHALL BE ENCLO

SED WITH A 2-HR ENCLO

SURE AT TOP PER

CBC 713.11 AND 713.12.)

24" X 24" WALK PAD

CONDENSO

R UNIT, S.M.D.

CONDENSO

R PAD AND LOW

WALL

DIRECTIONAL SIG

NAGE INDICATING

ACCESSIBLE PATHS O

F TRAVEL AND WARNING

OF

NON-ACCESSIBLE PATH

12" SEISMIC G

AP

12" SEISMIC G

AP AT 2-HR FIRE-RATED SEPARATION,

SEE 3/A8.14

REMO

VABLE LIFT STORAG

E

G.C. SHALL FILL ALL JO

INTS IN BETWEEN

STRUCTURAL COLUM

NS AND ADJACENT WALLS, TYP.,

WITH APPRO

VED SEALANT, MEETING

ALL REQ

UIREMNTS FO

R JOINTS AND VO

IDS AT INTERSECTIO

NS PER CBC 707.8 AND 707.9.

2-WAY CO

MM

UNICATION DEVICE TO

BE PROVIDED AT

EACH ELEVATOR LANDING

MEETING

ALL REQ

UIRMENTS O

F CBC 1007.8.1.

ROLL-DO

WN O

VERHEAD COILING

"SMO

KEGUARD"

DOO

R OR APPRO

VED EQUAL O

N MAG

NETIC AUXILIARY TRACK

REMO

VABLE LIFT LOCATIO

N - S.L.A.D.

8"-WIDE TRENCH DRAIN, S.S.D.

DESIGN/BUILD HO

T-DIPPED GALVANIZED SECURITY

SCREEN, PAINTED BLACK. SEE 13/A8.40

"UNAUTHORIZED VEHICLE" PARKING

SIGN PER CBC

1109A.8.8 & 11B-502.8, DEFERED SUBMITTAL.

DESIGNATED PARKING

FOR FUEL-EFFICIENT AND

CARPOO

L/VANPOO

L VEHICLES, PER CGBC TABLE

5.106.5.1.1 AND PARKING CALCULATIO

NS 4/A0.1. PAINTING

AT STALL TO BE SUCH THAT THE LO

WER

EDGE O

F THE LAST WO

RD ALIGNS W

ITH THE END OF

THE STALL STRIPING AND IS VISIBLE BENEATH A

PARKED VEHICLE PER CGBC AT.106.5.13.

LEGEND

STUD WALL

PARTIAL HEIGHT W

ALL

1-HOUR FIRE RATED W

ALL

CONCRETE W

ALL/COLUM

N, S.S.D.

SEE A10.0 FOR SPECIFIC W

ALL TYPES

2-HOUR FIRE RATED W

ALL

FULL HEIGHT CM

U WALL

PARTIAL HEIGHT CM

U WALL

w/ METAL STUD W

ALL ABOVE

DROPPED CEILING

PROPERTY LINE

FIRE EXTINGUISHER

CC-I

CC-II

CAR CHARGING

STATION-TYPE I

CAR CHARGING

STATION-TYPE II

W/D

UP

UP

FIRE WALL TERM

INATION (FLO

ORS 1, 2, 3, & 4):

CBC SEC. 706.5 HORIZ. CO

NTINUITY: EXCEPTIO

N 1 - FIRE WALL TERM

INATES AT 1-HR FIRE RATED EXTERIOR W

ALL; NO

OPENING

S OCCUR W

ITHIN 4'-0" OF EITHER SIDE O

F FIRE WALL

TERMINATIO

N AT THIS LOCATIO

N.

CBC SEC. 706.5.1 EXTERIOR W

ALLS:O

PTION 1 - EXTERIO

R WALLS O

N BOTH SIDES O

F FIRE WALL TERM

INATION ARE

1-HR FIRE-RATED AND EXTEND 4'-0" MIN AW

AY FROM

FIRE WALL TERM

INATION.

NO O

PENINGS O

CCUR WITHIN 4'-0" O

F EITHER SIDE OF FIRE W

ALL TERM

INATION AT THIS LO

CATION.

CBC SEC. 706.5.2 HORIZ. PRO

JECTING ELEM

ENTS:NO

PROJECTING

ELEMENTS AT THIS LO

CATION.

A1-1NO

:1011 BDRM722 S.F.

TYPE:

A2-1NO

:1041 BDRM707 S.F.

TYPE:

A1-1NO

:1021 BDRM722 S.F.

ROO

M--

173 MAIL

ROO

M--

171 ELEC.

TERMINATIO

N-1--

01

RUBBISH

STAGING--

16

RES. TRASH

ROO

M--

163

BOO

STER PUMP

STORAG

E--158

BICYCLE

STORAG

E--164

BICYCLE

--165

RETAIL--166

RETAIL--167

RETAIL--168

RETAIL--169

RESTAURANT

STORAG

E--162

BICYCLE

STAIR 2--4

ELEVATOR 2--

(RETAIL EV CHARGING

STATIO

N TO ADA STD.

NOT M

ARKED AS ACCESSIBLE)

3668 S.F.

1340 S.F.

1370 S.F.

1342 S.F.

2612 S.F.

All d

rawin

gs a

nd w

ritte

n m

ate

ria

lappearin

g h

erein

constitu

te o

rig

inal,

and u

npublis

hed w

ork o

f th

e a

rchite

ct

and m

ay n

ot b

e d

uplic

ate

d, u

sed o

rdis

clo

sed w

ithout th

e w

ritte

n c

onsent

of th

e a

rchite

ct.

BLDG PLANS

Drawn B

yIM

Project N

o.

Sheet S

ize: 3

0 x

42

Scale

1/8"=1'-0"

FLOO

R 1

A2.1A

Sheet T

itle

ZONE A

S t a

m p

Date

Issue

---

--------------------------- ---

---------------------------

Clie

nt

Consulta

nt

95

0H

ow

ard

St

ere

tS

an

Fran

cis

co

P.

415

677

0966

()

-

CA

94103

DUBLIN APARTMENTS

7544 Dublin Boulevard

Dublin, CA 94568

10.17.14DD Prog. Check Set

1429

10.31.14100%

DD Set

11.14.1425%

CD Set

50% CD Set

12.12.14

Permit Set

01.09.15

02.03.15Pricing Set 1

103.27.15

Permit Rev.

206.08.15

Permit Rev.

308.05.15

Permit Rev.

408.20.15

Permit Rev.

509.23.15

Construction Set

TRUENO

RTH

PROJECT

NORTH

016

84

All d

rawin

gs a

nd w

ritte

n m

ate

ria

lappearin

g h

erein

constitu

te o

rig

inal,

and u

npublis

hed w

ork o

f th

e a

rchite

ct

and m

ay n

ot b

e d

uplic

ate

d, u

sed o

rdis

clo

sed w

ithout th

e w

ritte

n c

onsent

of th

e a

rchite

ct.

BLDG PLANS

Drawn B

yIM

Project N

o.

Sheet S

ize: 3

0 x

42

Scale

1/8"=1'-0"

FLOO

R 1

A2.1B

Sheet T

itle

ZONE B

S t a

m p

Date

Issue

---

--------------------------- ---

---------------------------

Clie

nt

Consulta

nt

95

0H

ow

ard

St

ere

tS

an

Fran

cis

co

P.

415

677

09

66

()

-

CA

94103

DUBLIN APARTMENTS

7544 Dublin Boulevard

Dublin, CA 94568

10.17.14DD Prog. Check Set

1429

10.31.14100%

DD Set

11.14.1425%

CD Set

50% CD Set

12.12.14

Permit Set

01.09.15

02.03.15Pricing Set 1

103.27.15

Permit Rev.

206.08.15

Permit Rev.

308.05.15

Permit Rev.

408.20.15

Permit Rev.

509.23.15

Construction Set

W/D

W/D

W/D

W/D

UP

FIRE WALL TERM

INATION (FLO

ORS 1, 2, 3, & 4):

CBC SEC. 706.5 HORIZ. CO

NTINUITY: EXCEPTIO

N 1 - FIRE WALL TERM

INATES AT 1-HR FIRE RATED EXTERIOR W

ALL; NO

OPENING

S OCCUR W

ITHIN 4'-0" OF EITHER SIDE O

F FIRE WALL

TERMINATIO

N AT THIS LOCATIO

N.

CBC SEC. 706.5.1 EXTERIOR W

ALLS:O

PTION 1 - EXTERIO

R WALLS O

N BOTH SIDES O

F FIRE WALL TERM

INATION ARE

1-HR FIRE-RATED AND EXTEND 4'-0" MIN AW

AY FROM

FIRE WALL TERM

INATION.

NO O

PENINGS O

CCUR WITHIN 4'-0" O

F EITHER SIDE OF FIRE W

ALL TERM

INATION AT THIS LO

CATION.

CBC SEC. 706.5.2 HORIZ. PRO

JECTING ELEM

ENTS:NO

PROJECTING

ELEMENTS AT THIS LO

CATION.

A4-1NO

:1061 BDRM796 S.F.

TYPE:

A2-1NO

:1041 BDRM707 S.F.

TYPE:A4-1NO

:1081 BDRM796 S.F.

TYPE:A4-1NO

:1101 BDRM796 S.F.

TYPE:

ROO

M--

171 ELEC.

OFFICE--

177

LEASING

TRASH--174

RESTAURANT

--175

RETAIL

--176

RESTAURANT

STAIR 1--4

MECH.

--

2295 S.F.

3575 S.F.

SHEET NOTES

GENERAL NO

TES

FIRE DEPARTMENT KEY-BO

X LOCATIO

N

DESIGN/BUILD O

VERHEAD COILING

SECURITY GATE

WITH KEYED & FO

B-CONTRO

LLED ACCESS. GATE

SHALL MEET REQ

.S OF CFC SECTIO

N 1008.1.4.4.

DESIGN/BUILD STL HO

T-DIPPED GALV. SECURITY SITE

GATE BY G

.C. PER DESIGN INTENT M

OUNTED O

N STRUCTURALLY ISO

LATED TUBE STL, SEE 6/A8.40

CONCRETE SHEAR W

ALL, S.S.D. SEE A10.00 FOR W

ALL ASSEM

BLIES

CONCRETE W

HEEL STOP

43" STEEL GUARD RAIL

STANDARD PARKING SPACE, TYP. (9'-0" x 20'-0")

COM

PACT PARKING SPACE, TYP. (8'-0" x 17'-0")

TYPICAL ACCESSIBLE PARKING SPACE PER A0.5

VAN-ACCESSIBLE PARKING SPACE PER A0.5

ADA STRIPING

FLOO

R/AREA DRAINS, S.P.D., S.S.D.

CONCRETE CO

LUMN, S.S.D.

HOSE BIB. NO

N-REMO

VABLE BACKFLOW

PREVENTION

DEVICE SHALL BE INSTALLED ON ALL HO

SE BIBS AND PO

TABLE WATER O

UTLETS WITH HO

SE ATTACHM

ENTS. CPC 603.5.7

TRASH/RECYCLING BIN, 3'-0" W

, 3'-0" H, 6'-0" L. G.C. TO

VERIFY SIZE W

ITH LOCAL W

ASTE MANAG

EMENT

COM

PANY PRIOR TO

PURCHASE

3"H x 8"W CO

NC. CURB FOR DUM

PSTER WHEELSTO

P

TRASH CHUTE DISCHARGE W

/FUSIBLE LINK

TRASH CHUTE: UL 90 MIN "B" LABEL; TR

ASH C

HU

TE IN

TAKE DO

OR

S SHALL BE AC

TIVATED BY

ELECTR

ICALLY O

R PN

EUM

ATICALLY C

ON

TRO

LLED

PUSH

BUTTO

N, AN

D SH

ALL BE FULLY C

OM

PLIANT

WITH

ALL ADA R

EQU

IREM

ENTS.

TRASH

CH

UTE VEN

T

RAIN

WATER

LEADER

TO SPLASH

BLOC

K BELOW

10" SEISMIC G

AP, SEE 1 & 2/A8.14

FIRE SPR

INKLER

RISER

IN 1-H

R R

ATED R

ECESSED

C

ABINET: LAR

SEN FS VC

2626-R )W

HEN

NO

T IN A

STAIR). D

ESIGN

/BUILD

ENG

INEER

TO LO

CATE. W

HERE RISER DO

ES NOT O

CCUR WITHIN A STAIR

ENCLOSURE, PRO

VIDE FIRE-CAULKING AT EACH

FLOO

R PENETRATION.

INDICATES DROPPED G

WB CLG

W/ RECESSED "CAN"

LIGHTING

, SEE BLDG RCPS O

N SHEETS A6.1 & A6.2.

DASHED LINE INDICATES DROPPED G

WB CLG

W/

RECESSED "CAN" LIGHTING

AND SCORED 2' X 2'

CONCRETE AT FLO

OR

USPS-APPROVED RESIDENT M

AILBOXES W

/ REACH RANG

E BETWEEN 28" A.F.F. AND 54" A.F.F. O

NE PARCEL BO

X PER 10 RESIDENTS TO BE INCLUDED

OUTLINE O

F 2'-0" x 7'-0" GURNEY

VEHICULAR CLEARANCE BAR LOCATIO

N

2 HOUR FIRE RATED AREA SEPARATIO

N WALL - SEE

SHEET A10.0.

LINE OF LEVEL ABO

VE

A. DIMENSIO

NS ARE TO FACE O

F STUD, CONCRETE O

R FO

UNDATION W

ALL, TYP. U.O.N.

B. SEE A0.3 AND A0.4 FOR BUILDING

AREA CALCULATIONS.

C. SEE A0.6 FOR ACCESSIBILITY AND ADAPTABILITY

REQUIREM

ENTS.

D. SEE A0.7 - A0.11 FOR EG

RESS CALCS. AND DIAGRAM

S.

E. UNIT PLANS SHOW

N HERE ARE DIAGRAM

ATIC REFER TO 1/4"

UNIT PLANS AND ENLARGED PLANS FO

R ADDITIONAL

INFORM

ATION NO

T SHOW

N HERE.

F. SEE SHEET A10.0 FOR W

ALL TYPE SCHEDULE AND TYPICAL ASSEM

BLIES.

G. SEE LANDSCAPE DRAW

INGS FO

R INFORM

ATION REG

ARDING

THE GRADING

OF ALL EXTERIO

R AREAS.

H. CIVIL ELEV. 340.2' = ARCHITECTURAL ELEV. 0'-0".

I. ALL EXTERIOR W

OO

D WALLS TO

RECEIVE PLYWD SHEATHING

.

J. REFER TO STAIR DRAW

INGS FO

R INFORM

ATION NO

T SHOW

N HERE.

K. G.C. TO

COO

RDINATE MECH. AND PLUM

B. VENTS AS PERM

ITTED BY CODES TO

MINIM

IZE ROO

F PENETRATIONS.

L. G.C. TO

COO

RD. AND INSTALL VENTING FO

R ALL CONCEALED

ROO

F AREAS AND OTHER EXTR W

OO

D FRAMED VO

IDS.

M. ALL G

SM FLASHING

SHALL BE BONDERIZED AND PAINTED O

R RECEIVE CO

ATINGS TO

MATCH SURRO

UNDING M

ATERIALS.

N. ROO

F SLOPES NO

TED ARE MINIM

UMS. RO

OF SLO

PES OF

CRICKETS SHOW

N DIAGRAM

MATICALLY O

N ROO

F PLANS MAY

EXCEED 3/8"/FT TO ACHIEVE PRO

PER ROO

F DRAINAGE AS

SHOW

N.

O. G

.C. TO INCLUDE AND CO

ORDINATE RO

OF CRICKETS IN FIELD

FOR PRO

PER DRAINAGE IN ACCO

RDANCE WITH CO

DE AND RO

OF M

ANUFACTURER'S WARRANTY.

P. U.O.N., TYPICAL W

ALL TYPES AT FLOO

RS BELOW

PODIUM

SLAB TO

BE: 1. EXTERIO

R WALLS: TYPE B. SEE EXTERIO

RELEVATIO

NS FO

R FINISH TYPES AND LOCATIO

NS. 2. INTERIO

R WALLS: TYPE P1.

3. INTERIOR 2-HR RATED W

ALLS: TYPE R.U.O

.N., TYPICAL WALL TYPES AT FLO

ORS ABO

VE PODIUM

SLAB TO

BE: 1 . EXTERIO

R BUILDING W

ALLS INCLUDING W

ALLS AT CO

URTYARDS: TYPE C1. SEE EXTERIOR ELEVATIO

NS FOR

FINISH TYPES AND LOCATIO

NS.2. INTERIO

R CORRIDO

R WALLS: TYPE E.

3. INTERIOR STAIR/ELEVATO

R SHAFT WALLS: TYPE D2 AT

CORRIDO

R / TYPE H2 ADJACENT TO DW

ELLING UNIT

4. UNIT DEMISING

WALLS: TYPE H1.

5. 2-HR MECHANICAL SHAFT W

ALLS: K.6 . INTERIO

R UNIT WALLS: TYPE G

OR D1.

7. FIRE WALLS TO

BE TYPE "J" U.O.N.

Q. W

HERE WALL FINISHES DO

NOT ALIG

N DUE TO CHANG

E IN W

ALL TYPE, GC TO

PROVIDE BACKING

TO ENSURE A FLUSH

FINISH TRANSITION

R. SEE A8 SERIES SHEETS FOR TYP. RO

OF PIPE PENETRATIO

N & W

ATERPROO

FING INFO

RMATIO

N

S. U.O.N., ALL EXTERIO

R DWELLING

UNIT DECKS AND EXPOSED

CONCRETE SURFACES TO

RECEIVE WATERPRO

OF TRAFFIC

COATING

PER SPECIFICATIONS. SEE ALSO

LANDSCAPE PLANS FO

R EXTERIOR AREAS THAT ARE TO

RECEIVE PAVERS.

T. REINFORCED 15-M

IL VAPOR BARRIER TO

BE PROVIDED

UNDER SLAB, TYP. SEE BE DRAWING

FOR EXCEPTIO

NS.

U. STANDPIPE LOCATIO

NS SHOW

N ON PLANS ARE

DIAGRAM

MATIC; FIRE SPRINKLER SUBCO

NTRACTOR TO

PRO

VIDE STANDPIPE LOCATIO

N PLAN FOR REVIEW

BY ALAM

EDA COUNTY FIRE DEPARTM

ENT. PER CBC 905.4, CLASS I STANDPIPE HO

SE CONNECTIO

NS SHALL BE PROVIDED IN THE

FOLLO

WING

LOCATIO

NS:1. IN EVERY STAIRW

AY AT THE INTERMEDIATE LANDING

LEVEL2. O

N EACH SIDE OF HO

RIZONTAL EXITS

3. AT EACH EXIT PASSAGEW

AY, AT THE ENTRANCE FROM

THE EXIT PASSAG

EWAY TO

OTHER BUILDING

AREAS4. W

HERE THE MO

ST REMO

TE PORTIO

N OF A FLO

OR IS M

ORE

THAN 150' FROM

A HOSE CO

NNECTION

5. WHERE THE RO

OF HAS A SLO

PE LESS THAN 4 UNITS

VERTICAL IN 12 UNITS HORIZO

NTAL, A HOSE CO

NECTION

SHALL BE LO

CATED TO SERVE THE RO

OF O

R AT THE

HIGHEST LANDING

OF A STAIRW

AY WITH STAIR ACCESS TO

THE ROO

F.

V. FOR STRUCTURAL M

EMBERS REQ

UIRING INDIVIDUAL FIRE

PROTECTIO

N, SEE STRUCTURAL DRAWING

S. SEE ALSO 1/A9.20.

W. EXTERIO

R WALLS O

F VERTICAL EXIT ENCLOSURE THAT ARE

LOCATED AT AN ANG

LE OF LESS THAN 180º AND W

ITHIN 10 FEET HO

RIZONTALLY O

F A NON-RATED W

ALL OR UNPRO

TECTED O

PENING SHALL HAVE A FIRE-RESISTIVE RATING

OF NO

T LESS THAN 1-HR. O

PENINGS W

ITHIN SUCH EXTERIOR W

ALLS SHALL BE PRO

TECTED BY OPENING

PROTECTIVES HAVING

A FIRE PRO

TECTION RATING

OF NO

T LESS THAN 3/4 HOUR. THIS

CONSTRUCTIO

N SHALL EXTEND VERTICALLY FROM

THE G

ROUND TO

A POINT 10' ABO

VE THE TOPM

OST LANDING

OF THE

STAIRWAY O

R TO THE RO

OF LINE, W

HICHEVER IS LOW

ER PER CBC 1022.7.

X. FIRE WALL SHALL TERM

INATE AT A POINT NO

T LESS THAN 30" ABO

VE THE LOW

ER ROO

F LEVEL. THE EXTERIOR W

ALL ABO

VE THE LOW

ER ROO

F SHALL NOT HAVE LESS THAN A 1-HR

FIRE-RESISTANCE-RATED CONSTRUCTIO

N FROM

BOTH SIDES

WITH O

PENINGS PRO

TECTED BY FIRE ASSEMBLIES HAVE A A

FIRE PROTECTIO

N RATING O

F NOT LESS THAN 3/4 HR FO

R A MIN

MINIM

UM HEIG

HT OF 15 FEET PER SECTIO

N 706.6.1.

Y. G.C. SHALL PRO

VIDE EMERG

ENCY ALARM/W

ARNING SYSTEM

CAPABLE O

F ACTIVATING A M

EANS OF W

ARNING FO

R THE HEARING

IMPAIRED PER CBC 1007.11 AS PART O

F THE DESIGN

BUILD SYSTEM.

Z. 2-WAY CO

MM

UNICATION DEVICE CO

NECTED TO CENTRAL

CONTRO

L POINT AND SPECIFIC DIRECTIO

NS RELATED TO THE

USE OF EM

ERGENCY CO

MM

UNICATIONS SYSTEM

TO BE

PROVIDED AT EACH ELEVATO

R LANDING PER CBC 1007.8.1.

AA. JOINTS M

ADE IN OR BETW

EEN FIRE BARRIERS, AND JOINTS

MADE AT THE INTERSECTIO

N OF FIRE BARRIERS W

ITH UNDERSIDE O

F FIRE-RESISTANCE RATED FLOO

R OR RO

OF

SHEATHING, SLAB, O

R DECK ABOVE, AND THE EXTERIO

R VERTICAL W

ALL INTERSECTIONSHALL CO

MPLY W

ITH ALL REQ

UIRMENTS O

F CBC 715. THE VOIDS CREATED AT THE

INTERSECTION O

F A FIRE BARRIER AND A NO

N-FIRE-RESISTANCE-RATED ROO

F ASSEMBLY SHALL BE

FILLED PER REQUIRM

ENTS OF CBC 707.9.

BB. SMO

KE DAMPERS SHALL BE PRO

VIDED AT ALL DUCT PENETRATIO

NS OF O

F 1-HR FIRE RATED CORRIDO

R WALLS AND

CEILINGS ASSEM

BLIES PER CBC 714.4.1.2.

CC. GC IS TO

INCLUDE SPRINKLER HEADS AT ALL FURRED OUT

VOIDS AT EXTERIO

R WALLS.

SHEET NOTES, CO

NTINUEDLINE O

F ROO

F BELOW

STRUCTURAL DRAIN TO PIPE - S.P.D.

GSM

OVERLAND RELEASE SCUPPER

ROO

F DRAIN WITH O

VERFLOW

TO RAINW

ATER LEADER, SEE DETAIL 7/A8.00

ROO

F VENT, SEE DETAIL 12/A8.00

2-HR VENT SHAFT TO RO

OF - S.M

.D.

PARAPET WALL, SEE ELEVATIO

NS

ELEVATOR PENTHO

USE WITH 24" x 24" G

SM

HOISTW

AY VENT

ROO

FTOP HVAC EQ

UIPMENT M

OUNTED O

N PAD ADJACENT TO

PARAPET WALL, SEE 9&10/A8.00

WHITE TPO

ROO

FING

SEMI-RECESSED FIRE EXTING

UISHER & CABINET: LARSEN M

ODEL 2712 ALUM

INUM FRAM

E WITH G

LASS W

INDOW

OR APP'D EQ

. USE SURFACE-MTD CABINET

AT CONCRETE &CM

U WALLS. EXTING

UISHER TYPE 2A10BC. G

.C. TO INCLUDE IN PRICE (20) EXTRA FIRE

EXTINGUISHERSAND CABINETS TO

BE LOCATED PER

DIRECTION O

F LOCAL FIRE DEPARTM

ENT. WHERE

WALLS ARE REQ

UIRED TO HAVE A FIRE-RESISTANCE

RATING, FIXTURES SHALL BE INSTALLED SUCH THAT

THE REQUIRED FIRE-RESISTANCE SHALL NO

T BE REDUCED.SURFACE M

TD FIRE EXTINGUISHER AT CO

NCRETE

ROO

F PROTECTIO

N WALK PAD

COUNTERTO

P WITH G

ROM

METS O

VER CABINET FOR

TRASH / RECYCLING

HORIZO

NTAL EXIT AND STANDPIPES PER CBC 1025, CBC 905.4 AND CFC 702.3

36" HIGH HO

T-DIP GALVANIZED, PAINTED HANDRAIL

WITH 12" TO

P EXTENSION & 24" BO

TTOM

EXTENSION

GC SHALL PAINT SO

UTH FACADE OF (E) BUILDING

LINE OF SLAB EDG

E BELOW

MECHANICAL W

ALL PENETRATION - S.M

.D. FOR SIZE

AND COVER TYPE. ALL DUCT AND AIR TRANSFER

OPENING

S MUST CO

MPLY W

ITH FIRE PROTECTIO

N REQ

UIRMENTS O

F CBC 714.1.1.

HATCHING INDICATES 4'-0" ZO

NE MEASURED FRO

M

CENTERLINE OF 2-HR FIRE W

ALL WHERE SUCH W

ALL IS PERM

ITTED TO TERM

INATE AT THE UNDERSIDE OF

THE ROO

F SHEATHING IN W

HICH THERE ARE NO

OPENING

S IN THE ROO

F WITHIN 4 FEET O

F THE FIRE W

ALL, THE ROO

F IS COVERED W

ITH A MINIM

UM

CLASS B ROO

F COVERING

AND THE ROO

F SHEATHING

IS CONSTRUCTED O

F FIRE-RETARDANT-TREATED PLYW

OO

D FOR A M

INIMUM

DISTANCE OF 4 FEET O

N BO

TH SIDES OF THE FIRE W

ALL PER CBC 706.6, EXCEPTIO

N 4.

STACKING BICYCLE STO

RAGE SYSTEM

BY SARIS OR

APPROVED EQ

UAL

INDUSTRIAL DOUBLE W

ASH SINK

GAS M

ITIGATIO

N RISER - SEE VAPOR M

ITIGATIO

N DRAW

INGS, LISTED IN SHEET INDEX 1/A0.0

SECURITY PHONE PER DM

C 7.32.300; SEC 1010(K)(3)

SUMP W

ITH DRAIN, S.P.D.

60" L, 44" W, 60" H CEILING

-MO

UNTED FAN, S.M.D,

S.S.D.

DESIGN/BUILD FULL-HEIG

HT PAINTED HOT-DIP

GALVANIZED STEEL PICKET SECURITY FENCE

TRUNCATED DOM

ES

DROP CAP, S.S.D.

INFILL OPENING

WITH CM

U WALL 43" A.F.F. CO

NT ALO

NG RAM

P. DESIGN/BUILD HO

T-DIPPED G

ALVANIZED DECORATIVE M

TL RAILING INFRO

NT PER ELEVATIO

NS, PAINTED BLACK, SEE A8.40.

GARAG

E EXHAUST VENT, CONTINUO

US THROUG

H TO

ROO

F, S.M.D.

SUN SHADE

DESIGN/BUILD HO

T-DIPPED GALVANIZED STEEL

CANOPY, PAINTED BLACK, SEE 3/A8.41

TRENCH DRAIN

WALL-M

OUNTED BIKE RACK

SOIL BENEATH P.T. SLAB, S.S.D.

CAR CHARGER STATIO

N-TYPE I

CAR CHARGER STATIO

N-TYPE II

ASSUMED LO

CATION O

F FUTURE DEMISING

WALL

PARTIAL-HEIGHT W

ALL WITH RAILING

OUTLINE O

F MECHANICAL VENT SHAFT ABO

VE WITH

3-HR ENCLOSURE AT BO

TTOM

PER CBC 713.11. (SHAFT THAT DO

ES NOT EXTEND TO

THE UNDERSIDE O

F THE ROO

F SHEATHING, DECK O

R SLAB SHALL BE ENCLO

SED WITH A 2-HR ENCLO

SURE AT TOP PER

CBC 713.11 AND 713.12.)

24" X 24" WALK PAD

CONDENSO

R UNIT, S.M.D.

CONDENSO

R PAD AND LOW

WALL

DIRECTIONAL SIG

NAGE INDICATING

ACCESSIBLE PATHS O

F TRAVEL AND WARNING

OF

NON-ACCESSIBLE PATH

12" SEISMIC G

AP

12" SEISMIC G

AP AT 2-HR FIRE-RATED SEPARATION,

SEE 3/A8.14

REMO

VABLE LIFT STORAG

E

G.C. SHALL FILL ALL JO

INTS IN BETWEEN

STRUCTURAL COLUM

NS AND ADJACENT WALLS, TYP.,

WITH APPRO

VED SEALANT, MEETING

ALL REQ

UIREMNTS FO

R JOINTS AND VO

IDS AT INTERSECTIO

NS PER CBC 707.8 AND 707.9.

2-WAY CO

MM

UNICATION DEVICE TO

BE PROVIDED AT

EACH ELEVATOR LANDING

MEETING

ALL REQ

UIRMENTS O

F CBC 1007.8.1.

ROLL-DO

WN O

VERHEAD COILING

"SMO

KEGUARD"

DOO

R OR APPRO

VED EQUAL O

N MAG

NETIC AUXILIARY TRACK

REMO

VABLE LIFT LOCATIO

N - S.L.A.D.

8"-WIDE TRENCH DRAIN, S.S.D.

DESIGN/BUILD HO

T-DIPPED GALVANIZED SECURITY

SCREEN, PAINTED BLACK. SEE 13/A8.40

"UNAUTHORIZED VEHICLE" PARKING

SIGN PER CBC

1109A.8.8 & 11B-502.8, DEFERED SUBMITTAL.

DESIGNATED PARKING

FOR FUEL-EFFICIENT AND

CARPOO

L/VANPOO

L VEHICLES, PER CGBC TABLE

5.106.5.1.1 AND PARKING CALCULATIO

NS 4/A0.1. PAINTING

AT STALL TO BE SUCH THAT THE LO

WER

EDGE O

F THE LAST WO

RD ALIGNS W

ITH THE END OF

THE STALL STRIPING AND IS VISIBLE BENEATH A

PARKED VEHICLE PER CGBC AT.106.5.13.

LEGEND

STUD WALL

PARTIAL HEIGHT W

ALL

1-HOUR FIRE RATED W

ALL

CONCRETE W

ALL/COLUM

N, S.S.D.

SEE A10.0 FOR SPECIFIC W

ALL TYPES

2-HOUR FIRE RATED W

ALL

FULL HEIGHT CM

U WALL

PARTIAL HEIGHT CM

U WALL

w/ METAL STUD W

ALL ABOVE

DROPPED CEILING

PROPERTY LINE

FIRE EXTINGUISHER

CC-I

CC-II

CAR CHARGING

STATION-TYPE I

CAR CHARGING

STATION-TYPE II

016

84

TRUENO

RTH

PROJECT

NORTH

DUBLIN BLVD

GO

LD

EN

GA

TE

DR

±1,3

40

SF

±1,3

70 S

F

7545-7554

±3,668 SFCAN BE DEMISED

RETAIL PARKING SPACES

7550 7548

±1,3

42

SF

7546

±2,612 SF

7542-7544

ADDITIONAL RETAIL PARKING

AMAKARA SUSHILEASED

Page 4: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

D U B L I N , C A

7544 is centrally located in the heart of Downtown Dublin along Dublin Boulevard near both Interstate 580 and Interstate 680.

With a growth rate of over 10% annually, Dublin is the fastest growing city in Northern California. While the Downtown area has always been a thriving regional shopping destination, recent plans have been developed promoting more growth with more pedestrian oriented, vibrant mixed use projects to take shape.

A block away, the West Dublin/Pleasanton BART Station serves over 3,750 riders a day.

309

Apartment

Units

SITEDUBLIN BLVD - 28,000 ADT

West DublinStation

500

Planned

Apartment

Units

214,000 ADT

167,000 ADT

Page 5: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

±167,00

0 C

AR

S DA

ILY

DUBLIN RETAIL CENTER

HACIENDA CROSSING

SHOPS AT WATERFORD

FALLON GATEWAY

GRAFTON STATION

ROSE PAVILLION

PACIFIC PEARL

SHOPPES AT LIVERMORE

METRO 580PLEASANTON SQUARE

STONERIDGE MALL

DUBLIN PLACE

PERSIMMON PLACE

7 MILLION VISITORSPER YEAR

18 MILLION VISITORSPER YEAR

7544 DUBLIN BLVD.

±214,000 CARS DAILY

R E T A I L A E R I A L

Page 6: RETAIL FOR LEASE - LoopNet€¦ · design build system. z 2-way communication device conected to central control point specific directions related to use of emergency communications

Cushman & Wakefield Copyright 2018. No warranty or representation, express or implied, is made to the accuracy or completeness of the information contained herein, and same is submitted subject to errors, omissions, change of price, rental or other conditions, withdrawal without notice, and to any special listing conditions imposed by the property owner(s). As applicable, we make no representation as to the condition of the property (or properties) in question.

CO N TAC T F O R L E A S I N G I N F O R M A T I O N

NICOLE LYON +1 925 627 2485 [email protected] LIC #01975898

JAMES CHUNG +1 408 436 3630 [email protected] LIC #01408190