restore: acl instruments. tibial tunnel tibial guide designed for the precise placement of the...
TRANSCRIPT
![Page 1: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/1.jpg)
RESTORE: RESTORE: ACL ACL
instrumentsinstruments
![Page 2: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/2.jpg)
Tibial tunnelTibial tunnel
![Page 3: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/3.jpg)
Tibial tunnelTibial tunnel
![Page 4: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/4.jpg)
Tibial GuideTibial Guide
• Designed for the Designed for the preciseprecise placement placement of the femural guide-wireof the femural guide-wire
• Two points on the tibial plateauTwo points on the tibial plateau• Stable blocking system Stable blocking system • Clear angle scaleClear angle scale
![Page 5: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/5.jpg)
Tibial GuideTibial Guide
![Page 6: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/6.jpg)
Tibial GuideTibial Guide
• Guide placementGuide placement
![Page 7: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/7.jpg)
Tibial GuideTibial Guide
• Guide placement: 45°-55° angleGuide placement: 45°-55° angle
![Page 8: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/8.jpg)
Tibial GuideTibial Guide
Feature Benefit
Two points of fixation Stability
Ratchet One hand set-up
Clear scale Easy to identify angles
![Page 9: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/9.jpg)
Tibial tunnelTibial tunnel
![Page 10: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/10.jpg)
Fully fluted reamerFully fluted reamer
• Designed for creating the tibial Designed for creating the tibial tunneltunnel
• The grooves on the rod for collecting The grooves on the rod for collecting bone chipsbone chips
• Every Every 10 mm notches10 mm notches• Diameters:Diameters:
– 6, 7, 8, 9, 10, 11, 12, 13 mm6, 7, 8, 9, 10, 11, 12, 13 mm
![Page 11: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/11.jpg)
Fully fluted reamerFully fluted reamer
![Page 12: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/12.jpg)
Fully fluted reamerFully fluted reamer
Feature Benefit
Flutes channel Collect bone for fullfill holes
Full thickness Less tibial tunnel divergence
![Page 13: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/13.jpg)
Femoral tunnelFemoral tunnel
![Page 14: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/14.jpg)
Femural aimersFemural aimers
• Designed for a perfect placement of Designed for a perfect placement of the femural guide-wirethe femural guide-wire
• They prevent the backwall breakageThey prevent the backwall breakage• Every Every 10 mm notches10 mm notches • 4 4 OffsetOffset::
– 5, 6, 7, 8 mm5, 6, 7, 8 mm
![Page 15: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/15.jpg)
Femural aimersFemural aimers
![Page 16: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/16.jpg)
Femural aimersFemural aimers
• OffsetOffset obtained by obtained by an easy formulaan easy formula
OFFSET = OFFSET =
Tunnel diameter /2 Tunnel diameter /2
++
Wished thichkness*Wished thichkness*
** Usually 1 or 2 mmUsually 1 or 2 mm
![Page 17: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/17.jpg)
Femural aimersFemural aimers
Feature Benefit
2-3 mm Offset Avoid backwall break out
Graduate lenght Determine tunnel lenght
Handle with finger-hole Prevent instrument slippage
![Page 18: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/18.jpg)
ACL instrumentsACL instruments
![Page 19: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/19.jpg)
Acorn reamerAcorn reamer
• Designed for creating the femural Designed for creating the femural tunneltunnel
• Thin Thin shaftshaft for increasing for increasing manipulationmanipulation
• Every Every 5 mm notches5 mm notches• Diameters:Diameters:
– 8, 9, 10, 11, 12, 13 mm8, 9, 10, 11, 12, 13 mm
![Page 20: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/20.jpg)
Acorn reamerAcorn reamer
![Page 21: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/21.jpg)
Acorn reamerAcorn reamer
![Page 22: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/22.jpg)
Acorn reamerAcorn reamer
Feature Benefit
Thin shaft Easy removal from tunnels
Clear scale Easy to read increments
Sharp tip Easy to use
![Page 23: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/23.jpg)
Back cutting burrBack cutting burr
• You can clean and You can clean and chamfer the tibial chamfer the tibial tunnel tunnel
• Cannulated for better Cannulated for better useuse
![Page 24: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/24.jpg)
Graft sizer: 8-12 mmGraft sizer: 8-12 mm
• To determine the To determine the diameter of the diameter of the graft (BTB or ST) graft (BTB or ST)
• Plastic device Plastic device with channels of with channels of different different diameters: 8, 9, diameters: 8, 9, 10, 11, 12 mm10, 11, 12 mm
8
910 11
12
![Page 25: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/25.jpg)
ACL graft knifeACL graft knife
• Twin scalpel Twin scalpel bladesblades
• For ACL BTB graftFor ACL BTB graft• Available in:Available in:
– 8, 9, 10, 11, 12 8, 9, 10, 11, 12 mmmm
• Color codedColor coded
![Page 26: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/26.jpg)
ACL graft knifeACL graft knife
Feature Benefit
Sterile, disposable instrument
Guaranted sharpness for each procedure
Parallel knife blade Precise cutting of the patellar tendon graft
Color coded sizing Easy to identify sizes
![Page 27: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/27.jpg)
Pig Tail Pig Tail Tendon Tendon peelerpeeler
• Harvesting of semitendinosus and gracilis tendons
• Open “pig-tail” ring
![Page 28: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/28.jpg)
Pig Tail tendon peelerPig Tail tendon peeler
Feature Benefit
Stainless steel Long-lasting
Solid handle and shaft Releable
Slotted end Easy entry and removal of tendon
![Page 29: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/29.jpg)
TARGET TARGET Tendon Tendon harvesterharvester• Harvesting of semitendinosus and
gracilis tendons• Gun-shape
![Page 30: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement](https://reader031.vdocuments.mx/reader031/viewer/2022032313/56649e395503460f94b2b55a/html5/thumbnails/30.jpg)
TARGET TARGET Tendon Tendon harvesterharvester
Feature Benefit
Stainless steel Long lasting, releable
Long calibrated shaft Desired graft lenght measurements
Cylindrical closed cutting tip
Precise, controlled graft harvest tracking without laceration