restek essentials: featured chromatography products 2020 · 2020. 8. 1. · for our full selection!...
TRANSCRIPT
-
Reliable, Top-Quality Supplies for Your Lab
Resprep Line Expands • Polymeric SPE— alternative to silica-based sorbents.
• Eliminate cross-contamination with QR vacuum manifolds.
MXT Columns: A Perfect Fit for Compact and High-Temp GCsCoil diameters down to 2.5"
Simplify Gas Flow MeasurementWith its wide range of capabilities, the ProFLOW 6000 is the only flowmeter you need.
SSENTIALSESSENTIALS2020.2
www.restek.com
-
www.restek.com/GCacc = Less downtime + faster analyses2
Leverage the outstanding inertness, low bleed, and high reproducibility of Rxi 3-in-1 technology to gain:
• Accurate Data
• The Right Results Fast
• Maximized Instrument Uptime
Featured Rxi Columns
Rxi columns span the polarity range, so you can select a column perfectly matched to your analysis.
ID df Length temp. limits qty. cat.#
0.25 mm 0.25 µm 30 m -60 to 330/350 °C ea. 13323
Rxi-1msIdeal for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
ID df Length temp. limits qty. cat.#0.25 mm 0.25 µm 30 m -60 to 320/350 °C ea. 13623
Rxi-5Sil MSIdeal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
ID df Length temp. limits qty. cat.#0.25 mm 0.25 µm 30 m 30 to 340/360 °C ea. 13723
Rxi-XLBIdeal for many GC-MS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs.
ID df Length temp. limits qty. cat.#0.25 mm 1.40 µm 30 m -20 to 300/320 °C ea. 13868
Rxi-624Sil MS Ideal for volatile organics and residual solvents; a great choice for USP.
Rxi-65TGIdeal for the analysis of triglycerides in edible oils.
ID df Length temp. limits qty. cat.#0.25 mm 0.10 µm 30 m 40 to 370 °C ea. 17108
Learn more at www.restek.com/GCaccelerator
Same Separation, Speedier Solution Use a GC Accelerator kit and the EZGC method translator to accurately convert methods to a scaled-down column format.
• Speed up analysis time and increase sample throughput.
• Get the same results faster and without capital investment.
• GC Accelerator kit installs easily without damaging the GC column or interfering with the MS interface.
GC Accelerator Oven Insert Kitfor Agilent 5890, 6890, 7890, and 8890 instruments
Description Instrument qty. cat.#GC Accelerator Oven Insert Kit
for Agilent 5890, 6890, 7890, and 8890 instruments kit 23849
Simplify Gas Flow Measurement• Easy to use• NIST-Traceable calibration• Accurate measurements• Volumetric flowmeter• Extended flow range
With its wide range of capabilities, the ProFLOW 6000 is the only flowmeter you need. Real-time measurements can be made for various types of flow paths. Designed with explosive and flammable gases in mind.
Restek ProFLOW 6000 Electronic FlowmeterDescription Certification/Compliance qty. cat.#Restek ProFLOW 6000 Electronic Flowmeter with Hard-Sided Carrying Case
CE, Ex, WEEE, RoHS 2, China RoHS 2 ea. 22656
Patented
Put Rxi columns to work in your lab. Visit www.restek.com/rxi and order yours today.
Rxi-1HT
Rxi-5ms
Rxi-1ms
Rxi-5Sil MS
Rxi-5HT
Rxi-XLB
Rxi-1301Sil MS
Rxi-624Sil MS
Rxi-PAH
Rxi-17
Rxi-17Sil MS
Rxi-35Sil MS
-
No matter your analysis, go to www.restek.com for your GC columns and standards. 3
Flexible metal tubing allows coil diameters down to 2.5" to perfectly fit the smallest spaces. Restek MXT columns are available in a variety of standard and custom configurations.
For a list of popular MXT coiling configurations and custom ordering information, visit www.restek.com/MXT-config
The Perfect Fitfor Portable, Process, and High-Temperature GC Analysis
• Ideal for environmental monitoring, vapor intrusion, industrial hygiene, and personal air sampling.
• Higher uptake rates for excellent low-level sensitivity.
• Higher capacity for accurate sampling up to 30 days.
• Easy to use—no pump required.
Monitor a Wide Range of Chemicals with Easy-to-Use radiello Air Samplers
These are just our starter kits; visit www.restek.com/radiello for our full selection!
Finished with Column Install or Maintenance?Verify your column and detector performance by running a Restek test mix.
Restek offers a full line of column test mixes for GC and LC. Find yours at www.restek.com/Test-Mixes
Featured MXT Siltek-treated stainless-steel columns:
MXT-1Ideal for solvent impurities, PCB congeners (e.g., Aroclor mixes), gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, and oxygenates.
MXT-Biodiesel TGIdeal for sharp mono-, di-, and triglyceride peaks.
MXT-WAXIdeal for FAMEs, flavor compounds, essential oils, amines, solvents, xylene isomers, and U.S. EPA Method 603 (acrolein/acrylonitrile).
MXT-624Ideal for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
MXT-1HT SimDist Ideal for ASTM D2887, D6352, D7169, D7213, and D7500.
ID df Length temp. limits qty. cat.#0.53 mm 0.10 µm 5 m -60 to 430/450 °C ea. 70112
ID df Length temp. limits qty. cat.#0.53 mm 1.00 µm 30 m 40 to 240/250 °C ea. 70655
Description Type qty. cat.#Starter kit: 1 complete sampler for BTEX/VOCs, CS2 desorption, white diffusive body, cartridge + blank, support plate, adaptor
Samplers and Diffusive Bodies kit RAD130S
Starter kit: 1 complete sampler for 1,3-butadiene & isoprene, thermal desorption, yellow diffusive body, cartridge + blank, support plate, adaptor
Samplers and Diffusive Bodies kit RAD141S
Starter kit: 1 complete sampler for BTEX/VOCs, thermal desorption, yellow diffusive body, cartridge + blank, support plate, adaptor
Samplers and Diffusive Bodies kit RAD145S
Starter kit: 1 complete sampler for H2S, white diffusive body, cartridge + blank, support plate, adaptor
Samplers and Diffusive Bodies kit RAD170S
ID df Length temp. limits ModificationColumn Config qty. cat.#
0.53 mm 0.16 µm 14 m -60 to 380/430 °C
with 2 m Integra-Gap (Total column length
= 16 meters.)
7" 11-pin cage ea. 70289
ID df Length temp. limits qty. cat.#0.25 mm 1.40 µm 30 m -20 to 240/280 °C ea. 70968
ID df Length temp. limits qty. cat.#0.53 mm 0.21 µm 10 m -60 to 430 °C ea. 70118
-
Stock your lab with high-quality Restek GC accessories at www.restek.com/GCacc4
Purify Detector and Carrier Gas Easy-to-see indicators to signal breakthroughHeavy-walled inner glass tube, protected by a sealed outer plastic tube, further protects against leaks.
Rely on Our Proprietary Cleaning Process for Tubing Free of Residual Organics
For plumbing GC systems:
Turn to Restek PLOT Columns for Reproducible ResultsRestek’s next-generation PLOT columns show a constant flow behavior and have significantly improved mechanical stability, resulting in easier operation, better chromatography, and reduced particle release. Greater particle stability also means more reproducible retention times, virtually no spiking, and longer column lifetimes.
Go to www.restek.com/PLOT for our full selection!
Fittings Dimensions qty. cat.#1/₈" Brass 1.5" x 13" ea. 238131/₄" Brass 1.5" x 13" ea. 238121/₈" Stainless Steel 1.5" x 13" ea. 238151/₄" Stainless Steel 1.5" x 13" ea. 23814
Fittings Dimensions qty. cat.#1/₈" Brass 1.5" x 13" ea. 238091/₄" Brass 1.5" x 13" ea. 238081/₈" Stainless Steel 1.5" x 13" ea. 238111/₄" Stainless Steel 1.5" x 13" ea. 23810
Indicating Carrier Gas PurifierRemoves multiple impurities such as O2, H2O, CO2, CO, halo-genated compounds, siloxanes, hydrocarbons (heavier than butane), sulfur-containing molecules, and ammonia from inert gases (He, Ar, N2, and H2).
Indicating Detector Gas PurifierRemoves moisture and hydrocarbons (C5 and heavier) from dry air or inert gases.
Cleaned Copper Tubing
ID OD Max Pressure Wall Thickness qty. cat.#
0.065" 1/₈" 2,800 psig 0.030" 50 ft 226280.190" 1/₄" 1,000 psig 0.030" 50 ft 22629
MXT-Q-BOND Columns (Siltek-treated stainless-steel PLOT)df ID Temp. Limits Column Config qty. cat.#20 µm 0.53 mm -60 to 280/300 °C 7" 11-pin cage ea. 7971620 µm 0.53 mm -60 to 280/300 °C 3.5" Coil ea. 79716-273
Rt-Msieve 5A Columns (fused silica PLOT)df ID Temp. Limits qty. cat.#20 µm 0.25 mm -100 to 300 °C ea. 19773
Rt-Q-BOND Columns (fused silica PLOT)100% divinylbenzene
df ID Temp. Limits qty. cat.#8 µm 0.25 mm -60 to 280/300 °C ea. 19765
MXT-Msieve 5A Columns (Siltek-treated stainless-steel PLOT)df ID Temp. Limits Column Config qty. cat.#50 µm 0.53 mm -100 to 300 °C 7" 11-pin cage ea. 7972350 µm 0.53 mm -100 to 300 °C 3.5" Coil ea. 79723-273
Rinsed and Cleaned 304 Stainless-Steel Tubing
For carrier, fuel, make-up, and auxiliary gas lines:
ID OD Min Qty qty. cat.#0.03" 1/₁₆" 101 ft >100 ft/price per ft 215080.085" 1/₈" 101 ft >100 ft/price per ft 21514
Maximum continuous lengths are: 2,000 ft (1/₁₆" OD), 1,500 ft (1/₈" OD), and 750 ft (1/₄" OD). The availability of long lengths is subject to inventory constraints. Lead times may vary depend-ing on the continuous length needed. Please inquire before ordering.
Available in a variety of lengths and ODs.
These are our most popular dimensions. Visit www.restek.com/GC-tubing for the full selection.
-
Visit www.restek.com/air for sampling canisters, valves, and other air sampling gear. 5
• Independently manufactured by two different sources; easily meet 2nd source lab requirements.
• Pi-marked cylinders available for the EU.
• Drop-shipped directly to you for maximum shelf life (min. 12 months).
• Each cylinder comes with a certificate of analysis and unique serial number.
• All cylinders are disposable.
Two Sources of Pi-Marked Gas Calibration Standards —One Convenient Order
Find your gas calibration standards at www.restek.com/2ndsource
Simplify Your Workflow with RAVEqc Quick-Connect Air Valves• Tool-free design makes consistent, quality connections fast and easy.
• No wrenches mean no overtightening or cross-threading damage.
• Use alone or pair with a bellows/diaphragm valve for sample security and convenience.
• Check status at a glance—if the parts are connected, the valve is open.
• Standard compression or tube end fittings accommodate a wide variety of devices.
• Leak-free performance—each and every valve is helium leak tested to 1x10-⁶ mL/sec.
• Compatible with Entech Micro-QT valves.
Gas Sampling BagsCost-Effective Alternatives for Air Sampling
• Ideal for whole air sampling at ppb-ppm levels.
• Tedlar, ALTEF, and multi-layer foil bags in a wide range of sizes.
• Extensive line of sampling accessories and replacement parts.
www.restek.com/air
RAVEqc Valve Bracket, for Attaching to Restek Canister ea. 27375
Note: A RAVEqc valve bracket is required for use with Restek 1, 3, 6, and 15 L air sampling canisters when using the compression fitting mounted directly on the 1/4" canister tube stub. This bracket is not needed when using Restek miniature canisters or Entech canisters.
Description Material qty. cat.#Male RAVEqc Valve to ¹/₄" Male Compression Fitting Stainless Steel ea. 27367Male RAVEqc Valve to ¹/₄" Male Compression Fitting Siltek-Treated ea. 27368Female RAVEqc Valve to ¹/₄" Male Compression Fitting Stainless Steel ea. 27369Female RAVEqc Valve to ¹/₄" Male Compression Fitting Siltek-Treated ea. 27370Male RAVEqc Valve to ¹/₄" Tube End Fitting, Extended (1.58") (Note: requires a ¹/₄" nut and ferrule set, sold separately in 5-pks. as cat.# 23161) Stainless Steel ea. 27371
Male RAVEqc Valve to ¹/₄" Tube End Fitting, Extended (1.58") (Note: requires a ¹/₄" nut and ferrule set, sold separately in 5-pks. as cat.# 23161) Siltek-Treated ea. 27372
Male RAVEqc Valve to ¹/₄" Tube End Fitting, Short (1.23") (Note: requires a ¹/₄" nut and ferrule set, sold separately in 5-pks. as cat.# 23161) Stainless Steel ea. 27373
Male RAVEqc Valve to ¹/₄" Tube End Fitting, Short (1.23") (Note: requires a ¹/₄" nut and ferrule set, sold separately in 5-pks. as cat.# 23161) Siltek-Treated ea. 27374
Female RAVEqc Valve to ¹/₄" NPT Fitting Stainless Steel ea. 27365Female RAVEqc Valve to ¹/₄" NPT Fitting Siltek-Treated ea. 27366
Rinsed and Cleaned 304 Stainless-Steel Tubing
-
The Resprep line has other options for SPE sample prep: www.restek.com/resprep6
PTFE-Free Vials and Caps Ideal for PFAS AnalysisVials fit all 2.0 mL, 12 x 32 mm vial-based autosamplers.
Learn more about Resprep PLR products at
www.restek.com/PLR
Simultaneously Remove Phospholipids and Proteins in One Resprep PLR Procedure • Prevent signal suppression.• No analyte-specific method development.• Minimize contamination and maintenance.
From preparation to analysis, Restek is proud to
offer workflow solutions that help provide
accurate, reliable results.
Resprep Polymeric SPE Offers An Alternative to Silica-Based Sorbents.
Eliminate Cross-Contamination with
Resprep Quick-Replace Vacuum Manifolds • Disposable, quick-replace valve liners.• Screw-type valves for precise flow control.
Limited-Volume 2.0 mL, 9 mm Screw-Thread Polypropylene Vials
Type Volume Color Size qty. cat.#9 mm Screw-Thread 1.5 mL Clear 12 x 32 mm 100-pk. 232429 mm Screw-Thread 1.5 mL Clear 12 x 32 mm 1,000-pk. 232459 mm Screw-Thread 700 µL Clear 12 x 32 mm 100-pk. 232439 mm Screw-Thread 700 µL Clear 12 x 32 mm 1,000-pk. 23246
Analyzing PFAS? Visit www.restek.com/PFAS
Description qty. cat.#Resprep PLR SPE Cartridge, 25 mg/1 mL cartridge 100-pk. 28300Resprep PLR SPE 96-Well Plate, 25 mg/2 mL each well ea. 28301
Order today at www.restek.com/ResprepQR
Description Size qty. cat.#Resprep QR-12 Quick-Replace vacuum manifold 12-port kit 28298-VMResprep QR-24 Quick-Replace vacuum manifold 24-port kit 28299-VM
Find our full selection of Resprep Polymeric
SPE products at www.restek.com/resprep
Five distinct packings:
• HLB—for general purpose• MAX—for acids• MCX—for bases• WAX—for strong acids• WCX—for strong bases
Cartridgesfor high loading capacity
30 mg/1 mL60 mg/3 mL
200 mg or 150 mg, 6 mL500 mg/6 mL
96-Well Platesfor high throughput
and automation10 mg/2 mL30 mg/2 mL
• Silica-free, bonded polymeric material.
• High surface area.
• Stable over a wide pH range (0–14).
2.0 mL, 9 mm Solid-Top Polyethylene Caps
Type Cap Size Color qty. cat.#Screw-Thread 9 mm Clear 100-pk. 23244Screw-Thread 9 mm Clear 1,000-pk. 23247
-
See our entire line of guard cartridges and hardware at www.restek.com/LCguard 7
Everything You Need to Put Together Your Own LC-MS/MS Infusion Rig
Longer lifetimes mean higher sample throughput for your lab!
• Same chromatographic performance as original equipment.• Rugged electrode lasts longer and requires fewer replacements.
View testing results and learn more at www.restek.com/LongLifeESI
• Cost-effective protection for UHPLC systems.
• Minimize extra column volume.
• Maximize sample throughput with SPE, SLE, or other extensive sample preparations.
• Connect easily to any brand of column—including both Force and Raptor 1.8 µm columns.
Reliably Filter Out Particulates and Extend UHPLC Column Lifetimewith UltraShield UHPLC PreColumn Filters
For 3 and 5 µm Force columns, use EXP guard column cartridges: www.restek.com/force
Ultimate Protection for Raptor UHPLC Columns• Extreme protection from particulates and matrix contamination to extend column lifetime.
• Proven to withstand the same UHPLC pressures as Raptor analytical columns.
• Ideal when using dilute-and-shoot or other minimal sample preparation techniques.*
Other sizes available at www.restek.com/raptor
* To minimize extra column volume and maximize UHPLC throughput with extensive sample preparations, pair 1.8 µm Raptor columns with an UltraShield filter instead.
Description Porosity qty. cat.#UltraShield UHPLC PreColumn Filter 0.2 µm frit ea. 25809UltraShield UHPLC PreColumn Filter 0.2 µm frit 5-pk. 25810UltraShield UHPLC PreColumn Filter 0.2 µm frit 10-pk. 25811
LC-MS/MS Infusion KitDescription qty. cat.#LC-MS/MS Infusion Kit kit 25755
Long-Life ESI Electrode(for Sciex Turbo V Sources)
Description Instrument Model # qty. cat.#
Long-Life ESI Electrode Sciex Turbo V Ion Sources API 3200, 3500, 4000, 4500, 5000, 5500+, 6500, and 6500+ ea. 25831
ESI Electrode Gauge(for Sciex Turbo V Sources)
Description Instrument qty. cat.#ESI Electrode Gauge Sciex Turbo V Ion Sources ea. 25832
Description Particle Size Size qty. cat.#
Raptor C18 EXP Guard Column Cartridge UHPLC 5 x 2.1 mm 3-pk. 9304U0252Raptor C18 EXP Guard Column Cartridge UHPLC 5 x 3.0 mm 3-pk. 9304U0253Raptor ARC-18 EXP Guard Column Cartridge UHPLC 5 x 2.1 mm 3-pk. 9314U0252Raptor ARC-18 EXP Guard Column Cartridge UHPLC 5 x 3.0 mm 3-pk. 9314U0253Raptor Biphenyl EXP Guard Column Cartridge UHPLC 5 x 2.1 mm 3-pk. 9309U0252Raptor Biphenyl EXP Guard Column Cartridge UHPLC 5 x 3.0 mm 3-pk. 9309U0253Raptor FluoroPhenyl EXP Guard Column Cartridge UHPLC 5 x 2.1 mm 3-pk. 9319U0252Raptor FluoroPhenyl EXP Guard Column Cartridge UHPLC 5 x 3.0 mm 3-pk. 9319U0253
EXP Direct Connect HolderDescription qty. cat.#EXP Direct Connect Holder for EXP Guard Cartridges (includes hex-head fitting & 2 ferrules)
ea. 25808
EXP Ferrule, Titanium Hybrid, ea. ea. 25935EXP Ferrule, Titanium Hybrid, 10-pk. 10-pk. 25936
Get More Uptime with Restek’s Long-Life ESI Electrode for Sciex Turbo V Sources
Use with any LC-MS/MS and syringe pump—you can even Tee-in your LC mobile phase for the best signal optimization.
-
ID Length
RaptorBiphenyl
LC Columns (USP L11)
1.8 µm Particles2.1 mm 30 mm 93092322.1 mm 50 mm 93092522.1 mm 100 mm 93092122.1 mm 150 mm 93092623.0 mm 50 mm 930925E3.0 mm 100 mm 930921E
Raptor FluoroPhenylLC Columns
(USP L43)
9319232931925293192129319262931925E931921E
RaptorARC-18
LC Columns (USP L1)
9314232931425293142129314262931425E931421E
Raptor C18
LC Columns (USP L1)
9304232930425293042129304262930425E930421E
Questions? Contact us or your local Restek representative (www.restek.com/contact-us).Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. To unsubscribe from future Restek communications or to update your preferences, visit www.restek.com/subscribe To update your status with an authorized Restek distributor or instrument channel partner, please contact them directly.
© 2020 Restek Corporation. All rights reserved. Printed in the U.S.A.
www.restek.com Lit. Cat.# GNES3177-UNV
Selectivity Accelerated
Further Boost UHPLC-MS/MS Efficiencies with 1.8 µm Raptor Columns• Higher efficiencies under UHPLC pressures.
• Better selectivity for substantially improved resolution.
• Long-lasting ruggedness for dependable reproducibility.
Also available with 2.7 and 5 µm particles to bring UHPLC speed to your existing HPLC instruments!
Order now at www.restek.com/raptor
Si
CH3
CH3
O
Si
CH3
CH3
O
F
F
F
F
F
Si O
Si
TMS
TMS
O
Reliably Versatile Restek FluoroPhenyl Phase:Get the power of HILIC and RP modes in one LC column.
Time-Tested Restek Biphenyl Phase: The established choice for bioanalytical testing since 2005.
Acid-Resistant Restek ARC-18 Phase:Ahead of the curve for large, multiclass lists by mass spec.
General-Purpose Restek C18 Phase:Traditional end-capped C18 ideal for general-purpose use.
Simplify LC Method Migration with Restek’s
Pro EZLC Method Translator• Scale down and speed up your current LC method to increase sample throughput.• Reduce solvent consumption and associated costs.• Increase certainty that your new method will meet performance requirements.
Start using Pro EZLC method translator today at www.restek.com/ezlc