response time and power consumption - shopify€¦ · cm1106. cu-1106,cu-1107,cu1109 power...

6
Response Time and Power Consumption CU-1106, CU-1107 CO2 Sensors

Upload: others

Post on 25-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

Response Time and Power Consumption

CU-1106, CU-1107 CO2 Sensors

Page 2: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

CU-1106 Response Time Curve

CU-1106 electrical response time≤3S,T90 response time is around 105S

400-5000ppm CU1106SL-N Response Time Test

Model Periodic point for zero measurement range

Periodic point for full measurement range

T90 periodic point for full measurement range T90(S)

CU1106-1# 27 66 56 116

CU1106-2# 28 57 51 92

0

1000

2000

3000

4000

5000

1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 101

ppm

Periodic point(Period=4S)

CU1106 Response Time

SL-N 1# SL-N 2#

Page 3: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

CU-1106 Power Consumption

The average power current of 100mS lighting is 20.2mA The average power current when sensor working(handling data) is 2.75mA

The average power current of 700mS preheating+lighting+data handling is 5.05mA Otii-Testing Instrument

Page 4: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

CU-1106, CU-1107, CU1109 Response Time Curve0-5000ppm Response time testing

Model AD value at zero measurement range

AD value at full measurement range

AD value at T90 for full measurement range T90(S)

CU-1106-1# 2821 2396 2438.5 73CU-1106-2# 2991 2538 2583.3 87CU-1107-1# 2609 2149 2195 82CU-1107-2# 2807 2335 2382.2 85CU1109-1# 2822 2413 2453.9 78CU1109-2# 2711 2253 2298.8 85

CU-1106, CU-1107, CU1109 electrical response time ≤ 3SPreheating time is 30S,T90 is around 85S for three models

2200

2300

2400

2500

2600

2700

2800

2900

3000

3100

300320340360380400420440460480500520540560580600620640660680700

AD

Time:s

0-5000PPM CU1106 CU1107 CU1109 2#

CM1109 CM1107 CM1106

2100

2200

2300

2400

2500

2600

2700

2800

2900

400410420430440450460470480490500510520530540550560570580590600610620630640650660670680690700AD

Time:s

0-5000PPM CU1106 CU1107 CU1109 1#

CM1109 CM1107 CM1106

Page 5: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

CU-1106,CU-1107,CU1109 Power Consumption

Model Light flashing Time/Period Pulse Current(Type) Average Current

CU-1106 256mS/1S 158mA 39mACU-1107 256mS/1S 170mA 42mACU1109 256mS+256mS/1S 203mA 65mA

CU-1106 CU-1107 CU1109

Otii testing instrument

Page 6: Response Time and Power Consumption - Shopify€¦ · CM1106. CU-1106,CU-1107,CU1109 Power Consumption. Model. Light flashing Time/Period. Pulse Current ( Type) Average Current

SJH-5 Cross Sensitivity Testing Curve

Sensor's displaying data curve under different HC gas

Cross Sensitivity Testing Curve