Response Time and Power Consumption
CU-1106, CU-1107 CO2 Sensors
CU-1106 Response Time Curve
CU-1106 electrical response time≤3S,T90 response time is around 105S
400-5000ppm CU1106SL-N Response Time Test
Model Periodic point for zero measurement range
Periodic point for full measurement range
T90 periodic point for full measurement range T90(S)
CU1106-1# 27 66 56 116
CU1106-2# 28 57 51 92
0
1000
2000
3000
4000
5000
1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 101
ppm
Periodic point(Period=4S)
CU1106 Response Time
SL-N 1# SL-N 2#
CU-1106 Power Consumption
The average power current of 100mS lighting is 20.2mA The average power current when sensor working(handling data) is 2.75mA
The average power current of 700mS preheating+lighting+data handling is 5.05mA Otii-Testing Instrument
CU-1106, CU-1107, CU1109 Response Time Curve0-5000ppm Response time testing
Model AD value at zero measurement range
AD value at full measurement range
AD value at T90 for full measurement range T90(S)
CU-1106-1# 2821 2396 2438.5 73CU-1106-2# 2991 2538 2583.3 87CU-1107-1# 2609 2149 2195 82CU-1107-2# 2807 2335 2382.2 85CU1109-1# 2822 2413 2453.9 78CU1109-2# 2711 2253 2298.8 85
CU-1106, CU-1107, CU1109 electrical response time ≤ 3SPreheating time is 30S,T90 is around 85S for three models
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
300320340360380400420440460480500520540560580600620640660680700
AD
Time:s
0-5000PPM CU1106 CU1107 CU1109 2#
CM1109 CM1107 CM1106
2100
2200
2300
2400
2500
2600
2700
2800
2900
400410420430440450460470480490500510520530540550560570580590600610620630640650660670680690700AD
Time:s
0-5000PPM CU1106 CU1107 CU1109 1#
CM1109 CM1107 CM1106
CU-1106,CU-1107,CU1109 Power Consumption
Model Light flashing Time/Period Pulse Current(Type) Average Current
CU-1106 256mS/1S 158mA 39mACU-1107 256mS/1S 170mA 42mACU1109 256mS+256mS/1S 203mA 65mA
CU-1106 CU-1107 CU1109
Otii testing instrument
SJH-5 Cross Sensitivity Testing Curve
Sensor's displaying data curve under different HC gas
Cross Sensitivity Testing Curve