residential elevator planning guide

28

Upload: brian-nichols

Post on 28-Mar-2016

232 views

Category:

Documents


5 download

DESCRIPTION

Symmetry Elevating Solutions is the leading provider of residential elevators in North America. With National Reach & Local Service, we have the strongest dealer network to sell, service & install your residential elevator.

TRANSCRIPT

Page 1: Residential Elevator Planning Guide
Page 2: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Symmetry ResidentialHome Elevator Systems

Table of Contents

Component Identification ....................................................................................3 Equipment for Symmetry Residential ................................................................5 Typical Hoistway Options .....................................................................................8 Typical Hoistway Construction ...........................................................................11 Typical Hoistway Overview ................................................................................12 Typical Machine Room Layouts ........................................................................... 13

2

About SymmetryBeautifully Crafted, Expertly Engineered, Thoughtfully Constructed

Symmetry is committed to its quest to develop innovative accessibility products, rigorous in its commitment to beautiful craftsmanship, expert engineering, thoughtful construc-tion, and affordability.

Symmetry is committed to being the leading provider of lift products in North America. We are focused on being your complete lift solutions provider.

Symmetry Elevating Solutions dealer network possesses over 120 combined years of hands-on, real-world home elevator and lift equipment experience.

Symmetry is committed to an unwavering, relentless, honest pursuit of excellence. The result? A visionary product expertly installed, unrivaled in the accessibility industry.

Page 3: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428 3

Symmetry Elevating SolutionsNational Reach. Local Service.

At Symmetry, we are your complete lift solutions provider! Please visit us at www.symmetryelevator.com to see our full line of lift solutions.

• ResidentialElevators • Dumbwaiters • Stairlifts • LimitedUse/LimitedAccessElevators • VerticalWheelchairLifts • AutoParkingSolutions-Vasari • VerticalReciprocatingConveyors • AutoGateOperators • MaterialHandlingEquipment • SpecialtyElevatorFixtures • PlannedMaintenanceandService

Page 4: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

COMPONENT IDENTIFICATIONIn-LineGear-DriveOverview

4

Motor Controller DisconnectCab Light Disconnect

Motor ControllerLocated within 50' of the motor

Drive Unit2 H.P. gearmotor with brakeSensorless Flux Vector Controlled

Car Frame

Modular Rail Structure

Roller Chain

Counterweight Assembly

Page 5: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

COMPONENT IDENTIFICATION

5

Modular Rail Structure

Ram Header

(2) 3/8” 7x9

14400# breaking strengthGalvanized Aircraft Cable

Car Frame

Hydraulic Cylinder

Motor Controller Disconnect

Cab Light Disconnect

Motor ControllerLocated within 50’ of the hydraulic power unit

Pedestal Post

Hydraulic Power Unit3 H.P. Submersed Motor / Screw PumpLocated within 40’ of the hydraulic cylinder

Hydraulic-DriveOverview

Page 6: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Equipment for Symmetry Residential Elevator In-LineGearDrive

6

General•Travel:Maximumof50’(minimum12”betweenstops)•Speed:40FPM•LoadCapacity:950#*OverheadMinimumof8’(96”)withremotecontroller

Minimumof9’withcontrollerinhoistway•Pitdepth:6”minimum(8”preferred)•Twostops•Singleopening•Threeyearlimitedpartswarranty

Mechanical Equipment•Modular61/4#T-railstructure•Carframeassembly•208/230VAC,60Hz,20ampsinglephasepowersupplyfor motor controller•120VAC,60Hz,15ampsinglephasepowersupply for lighting•(2)#60rollerchains•InvertercontrolledvariablespeedIn-LineGearassembly with counterweighted chain drive and 2 H.P. motor* Code compliant electrical disconnects included

Safety Features•Slackchainsafetydevice•Motorcontrollersupply(locatedincontroller)•Carlightsupply(locatedincontroller)•Upperandlowerfinallimits•Pitstopswitch•Cartopstopswitch•In-caremergencystopswitchandalarm•Safetyswitchforcargate(s)•Batterybackupemergencycarlightsandalarm•Electromechanicalhoistwaydoorinterlocks (doorsbyothers)

Controls•ProgrammableLogicController(PLC)•Non-selectivecollectiveautomaticoperation•SelfDiagnosticSystemwithdigitaldisplay•CarOperatingPanel(COP)availableinbrushed stainlesssteelorbrushedbrasswithLEDfloor position indicator•Hallstationsavailableinbrushedstainlesssteelor brushed brass with call button and car arrival indicator•Recessedphoneboxinbrushedstainlesssteelorbrushedbrass(phonejackincluded)•Automaticcarlighting•Singlefloordesignatedcarhoming*UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgateoperation(ifprovided)intheeventof power failure•Manualloweringdevice

Car Features•Cabsizeupto15squarefeet•7’0”interiorcarheight*Birch,Oak,orMapleflatveneerinteriorwallswith matching ceiling•Matchingwoodhandrail* Matching wood car sill•Unfinishedplywoodfloorwithsillsetfor.75” (flooringbyothers)*2energysavingrecessedLEDlightswithblacktrimrings•7’0”vinyllaminateaccordiongate(lightoak,darkoak,white,orantiquewhite)Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.

Optional Features•UptoSixstops•Singleautomaticpushbuttonoperation•Customcarsizeupto18squarefeet**

•Customcarheights•Insetpanelcarwithflushceiling•Insetpanelcarwithmatchingceiling•Raisedpanelcarwithmatchingceiling*4recessedLEDlightswithblacktrimrings•Factoryfinishedcar•Polishedstainlesssteel,polishedbrass,brushednickel,vintagebronzeandoilrubbedbrassfixtures(includingCOP,phonebox,hallcalls,andhandrail)* COP with integrated phone box•Customwoodinteriors*Customfactoryfinishes(antiqued,distressed,&crackle)*Greenmaterialalternativesandfinishesforcarinteriors•Scissorgate•Hardwoodveneeraccordiongate•Clearpanelaccordiongate•Autogateoperator(availableforusewithaccordion gateonly)•.75”finishedorunfinishedfactoryinstalledhardwood carflooring•Factoryflooringinsertfor1/4”flooringbyothers•Buffersprings(requiresminimumof10”pitdepth)•KeyswitchforCOPandhallstations•750#carcapacity

* This symbol denotes exclusive features** May require local code authority approval

Page 7: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Equipment for Symmetry Residential Elevator HydraulicDriveSystem

7

General•Travel:Maximumof50’(minimum12”betweenstops)•Speed:40FPM•LoadCapacity:950#*OverheadMinimumof8’(96”)withremotecontroller•Pitdepth:6”minimum(8”preferred)•Twostops•Singleopening•Threeyearlimitedpartswarranty

Mechanical Equipment•Modular61/

4#T-railstructure

•Carframeassembly•208/203VAC,60Hz,30ampsinglephasepowersupplyfor motor controller•120VAC,60Hz,15ampsinglephasepowersupply for lighting•(2)3/

8”7x19galvanizedaircraftcable(14400#breaking

strength)withwedgeropeshackles•80mmdiameterpiston/102mmdiametercylinderincl.1”- 3/

4”reducerbushing

•Screwpump(300micronscreen)•Positive pressure switch* Code compliant electrical disconnects included

Safety Features•Slackropesafetydevice•Motorcontrollersupply(locatedincontroller)•Carlightsupply(locatedincontroller)•RuptureValve(Type“C”Safety)•Pitstopswitch•Cartopstopswitch•In-caremergencystopswitchandalarm•Safetyswitchforcargate(s)•Batteryback-upemergencycarlightsandalarm•Electromechanicalhoistwaydoorinterlocks (doorsbyothers)

Controls•ProgrammableLogicController(PLC)•Non-selectivecollectiveautomaticoperation*SelfDiagnosticSystemwithdigitaldisplay•CarOperatingPanel(COP)availableinbrushed stainlesssteelorbrushedbrasswithLEDfloor position indicator•Hallstationsavailableinbrushedstainlesssteelor brushed brass with call button and car arrival indicator•Recessedphoneboxinbrushedstainlesssteelorbrushedbrass(phonejackincluded)•Automaticcarlighting•Singlefloordesignatedcarhoming*UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgateoperation(ifprovided)intheeventof power failure

Car Features•Cabsizeupto15squarefeet•7’0”interiorcarheight*Birch,Oak,orMapleflatveneerinteriorwallswith matching ceiling•Matchingwoodhandrail* Matching wood car sill•Unfinishedplywoodfloorwithsillsetfor.75” (flooringbyothers)*2energysavingrecessedLEDlightswithblacktrimrings•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)

Optional Features•UptoSixstops•Singleautomaticpushbuttonoperation•Customcarsizeupto18squarefeet**

•Customcarheights•Insetpanelcarwithflushceiling•Insetpanelcarwithmatchingceiling•Raisedpanelcarwithmatchingceiling*4recessedLEDlightswithblacktrimrings•Factoryfinishedcar•Polishedstainlesssteel,polishedbrass,brushednickel,vintagebronzeandoilrubbedbrassfixtures(includingCOP,phonebox,hallcalls,andhandrail)* COP with integrated phone box•Customwoodinteriors*Customfactoryfinishes(antiqued,distressed,&crackle)*Greenmaterialalternativesandfinishesforcarinteriors•Scissorgate•Hardwoodveneeraccordiongate•Clearpanelaccordiongate•Autogateoperator(availableforusewithaccordion gateonly)•.75”finishedorunfinishedfactoryinstalledhardwood carflooring•Factoryflooringinsertfor1/4”flooringbyothers•Buffersprings(requiresminimumof10”pitdepth)•KeyswitchforCOPandhallstations•750#carcapacity

* This symbol denotes exclusive features** May require local code authority approval

Page 8: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Hoistway Construction Outline:

• FURNISH APPROPRIATE RAIL BACKING FOR T-RAIL • CONSULT DEALER FOR SPAN OF GREATER THAN 10’ BETWEEN FLOOR JOISTS • MAINTAIN BELOW 1/8” TOLERANCES THROUGHOUT HOISTWAY • RAIL BACKING WALL MUST BE A LOAD BEARING WALL • PIT FLOOR MUST BE A MINIMUM OF 6” (8” PREFERRED) BELOW THE FINISHED FLOOR OF THE LOWEST LANDING. CONFIRM PIT DEPTH WITH ELEVATOR CONTRACTOR PRIOR TO CONCRETE POUR • CONSTRUCTION OF PIT FLOOR MUST WITHSTAND AN IMPACT LOAD OF 4000#, STATIC LOAD 2400# (950# CAPACITY) • 8’0” MINIMUM HOISTWAY OVERHEAD ABOVE THE FINISHED FLOOR AT THE TOP LANDING IS REQUIRED FOR 7’0” CAR WITH REMOTE CONTROLLER • 9’0” MINIMUM HOISTWAY OVERHEAD ABOVE THE FINISHED FLOOR AT THE TOP LANDING IS REQUIRED FOR 7’0” CAR WITH CONTROLLER LOCATED IN THE HOISTWAY • PROVIDE AN ACCESS HATCH FOR SERVICING THE CONTROLLER/DRIVE UNIT ON IN-LINE GEAR DRIVE ELEVATOR

• HATCH TO ACCESS MOTOR BRAKE ON UNITS WITH REMOTE CONTROLLER • HOISTWAY DOORS PROVIDED BY OTHERS. MINIMUM 3’0” X 6’8” SOLID CORE DOORS ARE RECOMMENDED • HOISTWAY MUST BE FREE OF ANY OBSTRUCTIONS UNRELATED TO THE ELEVATOR OPERATION (I.E. SPRINKLERS, PIPES, DUCTS, ETC,) • THE STRUCTURE OF THE HOISTWAY MUST ALLOW FOR INSTALLATION OF A CHAIN HOIST TO TRANSFER MATERIALS TO THE UPPER LANDINGS DURING ELEVATOR INSTALLATION

* This guide is for planning purposes only. This guide is NOT intended for construction purposes. Prior to construction, please request a job specific set of elevator plans to ensure correct and accuratedimensionsandrequirementsforyourproject.

*YourlocalSymmetryrepresentativewillassistyouinensuringyourprojectspecificplans will comply with your local and state codes and building authority.

8

Page 9: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall

9

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

DEP

TH

DEP

TH

WIDTH WIDTHRAIL C/L RAIL C/L

STRUCTURESTRUCTURE

DOOR C/L DOOR C/L

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

SINGLE OPENING, RAIL LEFT, RIGHT HAND DOOR OR RAIL RIGHT/LEFT HAND DOOR SINGLE OPENING, RAIL LEFT, LEFT HAND DOOR OR RAIL RIGHT/RIGHT HAND DOOR

SINGLE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR SINGLE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR

36 x 48 50½” 54½” 27¼” 28¾” 32¼”

36 x 60 50½” 66½” 33¼” 28¾” 32¼”40 x 54 54½” 60½” 30¼” 32¾” 33½”

36 x 48 54” 54½” 27¼” 28¾” 32¼”

36 x 60 54” 66½” 33¼” 28¾” 32¼”

40 x 54 55” 60½” 30¼” 28¾” 33½”

36 x 48 48” 62½” 23¼” 23¼” 32¼”

36 x 60 48” 74½” 23¼” 23¼” 32¼”

40 x 54 48” 68½” 24” 21¾” 33½”

48 x 36 54½” 50½” 27¼” 20¾” 32¼”

60 x 36 66½” 50½” 33¼” 20¾” 32¼”

54 x 40 60½” 54½” 30¼” 20¾” 32¼”

Car Size Width Depth Rail C/L Door C/L Clear Opening

Car Size Width Depth Rail C/L Door C/L Clear Opening

Car Size Width Depth Rail C/L Door C/L Clear Opening

Car Size Width Depth Rail C/L Door C/L Clear Opening

DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS

Page 10: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall

10

OPPOSITE OPENING, RAIL LEFT, RIGHT HAND DOOR OR RAIL RIGHT/LEFT HAND DOOR OPPOSITE OPENING, RAIL LEFT, LEFT HAND DOOR OR RAIL RIGHT/RIGHT HAND DOOR

90 DEGREE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR 90 DEGREE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR

36 x 48 50½” 54½” 27¼” 28¾” 32¼”

36 x 60 50½” 66½” 33¼” 28¾” 32¼”40 x 54 54½” 60½” 30¼” 32¾” 33½”

36 x 48 54” 54½” 27¼” 28¾” 32¼”

36 x 60 54” 66½” 33¼” 28¾” 32¼”

40 x 54 55” 60½” 30¼” 28¾” 33½”

36 x 48 50½” 55” 27¾” 25”/28½” 32¼”

36 x 60 50½” 67” 33¾” 25”/40½” 32¼”

40 x 54 54½” 61” 30¾” 29”/34½” 32¼”

36 x 48 50½” 55” 27¾” 25”/28½” 32¼”

36 x 60 50½” 67” 33¾” 25”/40½” 32¼”

40 x 54 54½” 61” 30¾” 29”/34½” 32¼”

Car Size Width Depth Rail C/L Door C/L Clear Opening

Car Size Width Depth Rail C/L Clear Opening

Car Size Width Depth Rail C/L Door C/L Clear Opening

Car Size Width Depth Rail C/L

Clear Opening

DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

DO

OR

C/L

DEPTH DEPTH

WID

TH

WID

TH

RAIL C/L RAIL C/L

STRUCTURE STRUCTURE

DOOR C/L

DO

OR

C/L

DOOR C/L

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

DO

OR

C/L

Door C/L A+B

Door C/L A+B

AA

BB

Page 11: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall

11

90 DEGREE OPENING, RAIL LEFT, LEFT HAND DOOR / RIGHT HAND DOOR 90 DEGREE OPENING, RAIL RIGHT, LEFT HAND DOOR / LEFT HAND DOOR

36 x 48 50½” 55” 27¾” 29¼/33¼” 28½”/32¼”

36 x 60 50½” 67” 33¾” 29¼/45¼” 28½”/32¼”

40 x 54 54½” 61” 30¾” 29¼/39¼” 32¼”

36 x 48 50½” 55” 27¾” 25”/33¼” 32¼”

36 x 60 50½” 67” 33¾” 25”/45¼” 32¼”

40 x 54 54½” 61” 30¾” 29”/39¼” 32¼”

Car Size Width Depth Rail C/L

Clear Opening Car Size Width Depth Rail C/L Clear

Opening

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

DOOR C/L

DEPTH

WID

TH

RAIL C/L

STRUCTURE

DO

OR

C/L

DOOR C/L

DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS

DOOR C/LA + B

DOOR C/LA + B

A A

B B

Page 12: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Hoistway ConstructionConstruction&RailBackingDetails

12

T-RAILREACTIONS

950#R1=190R2=350

Typical Rail BackingConstruction

PIT FLOOR LOADSImpact Load 4000 lbs Static Load 2400 lbs (950# Capacity)

PIT FLOOR DEPTH = 6” minimum required (8” preferred)

10' M

AX

Allow fordrywallthickness

hoistway)Pit wall

10"10"

10"10"

RailBackingCenterline

Drywall

Construction Detailsof Rail Backing:• Laminate (2) 2x10's and (2) 2x4's using wood glue and #8x2-3/4" screws.• All joints must be staggered.

Corner PostConstruction

Header

Floor Joists

Typical HoistwayConstruction Details

2 x 4

2 x 4

2 x 4

2 x 10 ’ s

2 x 10 ’ s

2 x 4

• Laminate (2) 2x10's and (2) 2x4's using wood glue and #8x2-3/4" screws.• All joints must be staggered.

RECOMMENDED:For superior structural and acoustic

performance, 1/2” plywood is recommendedunderneath the drywall on the rail wall

CENTERLINE OFRAIL BACKING

12" vertical screwspacing and 2" fromeach side o� 2x10centerline

Drywall(shown cutaway)

• For span exceeding 10’ max of travel contact your Symmetry elevator contractor.

FOR FIRE RATING REQUIREMENTS - CHECK LOCAL JURISDICTION

Page 13: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Hoistway Overview

13

RailBacking

CENTERLINE OFRAIL BACKING

10" 10"

Typical Framework with Drywall Construction

3" MAX* (INSIDE FACE OFHOISTWAY DOOR TO SILL)

*Dimensions are required by ASME A17.1

.5” - 1.5”* RUN CLR (SILL TO SILL)

TYPICAL DOOR LOCATION DETAIL** HORIZONTAL RUNNING CLEARANCES AS

REQUIRED BY ASME A17.1, SECTION 5.3

(LEFT HAND DOOR SHOWN)

.25" Thick MullCasing insideHoistway

2 1/2" REQUIREDINSIDE FACE OF DOORTO FACE OF DRYWALL(3" TO HOISTWAY SILL)

ELEVATORGATE

cove

r rev

eal o

utsi

de o

f jam

b)

Notes:1) 8’0” Overhead required for 7’0” Interior Cab Height for Hydraulic and Remote Controller In-Line Gear.

9’0” Overhead required for 7’0” Interior Cab Height for In-Line Gear with Controller in the Hoistway. (Includes 9” of Cartop Clearance.)

2) Minimum Floor to Floor Travel is 12” between Floors (If Travel is Less than 12” Consult Factory).

Maximum Floor to Floor Travel: 950lb Unit = 50’0”

3) Minimum Pit Depth is 6” (8” preferred) Impact Load @ Pit 6500lbs (950lb Capacity) Static Load @ Pit 3800lbs (950lb Capacity) Bu�er Springs require 10” Pit Depth Minimum.

4) Consult Local Authority to Ensure Compliance with State and Local Codes.

5) The Hoistway is required to be Free of all Pipes, Wiring, and Obstructions not related to the Operation of the Elevator.

Car Height Remote Controller Controller in Hoistway

7’0” 8’0” (96”) 9’0” (108”)

7’11” 8’11” (107”) 9’11” (119”)

OVERHEAD CLEARANCE REQUIREMENTS

(Hydraulic & IGD) (Hydraulic & IGD) (IGD Only)

6’8”

HO

ISTW

AY O

PEN

ING

6’8”

HO

ISTW

AY O

PEN

ING

6’8”

HO

ISTW

AY O

PEN

ING

6’8”

HO

ISTW

AY O

PEN

ING

7’0”

INSI

DE

HEI

GH

T

2” O

VER

TRAV

EL

OVE

RALL

HO

ISTW

AY -

SEE

NO

TE (5

)(P

IT+T

RAVE

L+O

VERH

EAD

)

4”

TOTA

L CA

R TR

AVEL

- SE

E N

OTE

(2)

OVE

RHEA

D -

SEE

NO

TE (1

)

PIT

- SEE

NO

TE (3

)

Page 14: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Machine Room LayoutsIn-LineGearDrive

14

IN-LINE GEAR DRIVE WITH REMOTE CONTROLLER IN MACHINE ROOM

Machine Stop SwitchManual Brake Release

Manual Lowering Access

Drive Unit

Door Interlock

Hoistway DoorTravel Cable

Rail Structure

Please note that this layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.

Notes:• Minimum overhead clearance as measured from the top of the upper most landing sill to the bottom of the shaft ceiling is 8' - 0" for a standard 7' - 0" car.

REMOTE CONTROLLER MACHINE ROOM LAYOUT

230VAC, 20 AMP, Single Phase(3 Wire Dedicated Circuit)*Feeding breaker must not be a G.F.I.

Car Light Disconnect(Fusible and Lockable)

Motor Controller Disconnect(Fusible and Lockable)

Motor Controller

Telephone Service For Elevator

115VAC, 15 AMP, Dedicated Single Phase*Feeding breaker must not be a G.F.I.

30" wide x 36" deep clear workingspace required in front of theMotor Controller by NEC.

Lockable Remote Controller Cabinet(18" wide x 18" high x 10" deep)Must be located within 50' of the drive unit.

CONSTRUCTION OF MACHINE ROOMS MUST ADHERE TO LOCAL, STATE, AND NATIONAL CODES.

30”

36”

Front View

TopView

Page 15: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Machine Room LayoutsIn-LineGearDrive

15

IN-LINE GEAR DRIVE WITH CONTROLLER IN HOISTWAY230VAC, 20 AMP, Single Phase

(3 Wire Dedicated Circuit)*Feeding breaker must not be a G.F.I.

Car Light Disconnect(Fusible and Lockable)

Motor Controller Disconnect(Fusible and Lockable)

Motor Controller

Travel Cable

Rail Structure

Please note that this layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.Notes:• Minimum overhead clearance as measured from the top of the upper most landing sill to the bottom of the shaft ceiling is 8' - 0" for a standard 7' - 0" car.

Hoistway DoorDoor Interlock

Manual Lowering Access

Drive UnitManual Brake Release

Machine Stop SwitchService Light Switch

115 VAC G.F.I. Duplex Receptacle(Must be separate from elevator circuits)

Telephone Service For ElevatorPlastic Coated Service Light Bulb With Guard

115VAC, 15 AMP, Dedicated Single Phase*Feeding breaker must not be a G.F.I.

MANUAL LOWERING ACCESS HATCH DETAIL

Rail Wall on a LHHoistway

Service AccessDoor---Use

Self-Closing Hinges.

Cent

er o

f Acc

ess

Doo

r

Upper LandingHoistway Door

Hall Station

CENTERLINE OF ACCESS DOOR

Cab Height: 6-8 7-0 7-2 7-11 8-0Dim. To door: 88" 90" 92" 101" 102"

CONSTRUCTION OF MACHINE ROOMS MUST ADHERE TO LOCAL, STATE, AND NATIONAL CODES.

(REQUIRED FOR ALLIGD APPLICATIONS)

ACCESSHATCHDETAIL

• This layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.

Page 16: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Machine Room LayoutsHydraulicDrive-StandardMachineRoom

16

5) MAXIMUM 360 DEGREES IN HARD PIPE BENDS.

MAIN HYDRAULICCONTROL BOX

HYDRAULIC POWER UNIT

Page 17: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Typical Machine Room LayoutsHydraulicDrive-CompactMachineRoom

17

MAIN HYDRAULICCONTROL BOX

HYDRAULIC POWER UNIT

Page 18: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Part 1 General1.01 Scope

The scope of this section of work is the provision of and installation - residential elevator and all the necessary equipment required to fully complete the installation and coordinate between the other associated work required by other trades. The equipmentspecificationsarebasedontheSymmetryElevatingSolutionsproductdesign–In-LineGearDrive–IGDdrive system with cantilever sling.

1.02 References

A. Elevator equipment shall be designed, manufactured, installed and maintained in compliance and accordance with the followingNationalandlocalStandards:VerifywithlocalAHJ.

1.AmericanNationalStandardsInstitute–ANSIA117.13.ICC/IBC-InternationalBuildingCode-Chapter301.NFPA70- 1999NationalElectricalCode-NECChapter620”

2.AmericanSocietyofMechanicalEngineers-ASMEA17.1Part5.3PrivateResidenceElevators

3.ICC/IBC–InternationalBuildingCodesA117.1

4.NFPA70-1999NationalElectricalCode–NEC

1.03 Quality Assurance

A. Elevator equipment shall be designed and tested to meet or exceed the above standards and provide the following specificcomponents.AllloadratingsandsafetyfactorsshallmeetorexceedthosespecifiedbylocalAHJandbecertifiedby an independent professional engineer.

B.ElevatorInstaller/contractorshallbecertifiedtoinstalltheequipmentbytheManufacturerandhavetheappropriate Local, State or National certifications to install this specific style of equipment. A minimum of 10 years industry experience. Shall be Insured to perform this type work including product and public liability insurance. Copies of current Certificates of Insurance shall be provided with the contract prior to the start of work.

C.ElevatorInspectionshallbeperformedpriortoturnovertoowner.InspectionshallbeperformedbythelocalAHJora competentpersontrainedtoperformthistypeinspectiontocomplywithAMSEA17.2asitrelatestopart5.3Private Residence Elevators.

1.04 Warranty

A. The Manufacturer shall warranty component parts of the Symmetry Elevating Solutions equipment for a period of 3 – Three yearsfromcompletionofelevatorinstallation.(SubmitWarrantydetailswithOwnersManual)

B.AqualifiedMaintenanceProgram,complyingwiththemanufacturer’srecommendedmaintenanceschedule,isrequiredduringthethree(3)yearperiodinordertomaintainthewarranty.

2.01 Product

General:

•Travel:Maximumof50’(minimum12”betweenstops)Actualtravel:_________feet______inches

•Speed:40FPM

•LoadCapacity:950#(upto50’oftravel)

•Overhead:Minimumof8’6”(102”)

•Pitdepth:6”minimum

•FloorsServed____2____3____4____5____6

•Cabentrance______Singleopening______Oppositeopenings_______90degree/Adjacentopenings

•Threeyearlimitedpartswarranty

18

Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive

Page 19: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

2.02 Mechanical EquipmentMechanicalEquipmentandDrive:In-LineGearDrive

•Modular61/4#T-railstructure

•Carframeassembly:Cantilever

•208/230VAC,60Hz,20ampsinglephasepowersupplyformotorcontroller

•120VAC,60Hz,15ampsinglephasepowersupplyforlighting

•(2)#60rollerchainsuspensionmeans

•InvertercontrolledvariablespeedgearedassemblywithIn-LineGeardriveunitand2H.P.motor.

*Code compliant electrical disconnects included

2.03 Safety Devices:

•Slackchainsafetydevice

•Motorcontrollersupplydisconnect(locatedincontroller)

•Carlightsupplydisconnect(locatedincontroller)

•Pitstopswitch

•Cartopstopswitch

•In-caremergencystopswitchandalarm

•Safetyswitchforcargate(s)

•Batterybackupemergencycarlightsandalarm

•Electromechanicalhoistwaydoorinterlocks(doorsbyothers)

•UninterruptiblePowerSupply–(UPS)forcarloweringandautomaticgateoperation(ifautogateoperatorprovided)inthecaseofpowerfailure(toallowemergencylowerofcabincaseofmainpowerfailure)

2.04 Controls:

•ProgrammableLogicController(PLC)

•Non-selectivecollectiveautomaticoperation

•SelfDiagnosticSystemwithdigitaldisplay(ateachlandingandincar)

•CarOperatingPanel(COP)withLEDfloorpositionindicator–Finishesseesection2.05

•Hallstationswithcallbuttonandcararrivalindicator.–Finishesseesection2.05

•Recessedphoneboxinsamefinishabove(phonejackincluded)–Finishesseesection2.05

•Automaticcarlighting

•Singlefloordesignatedcarhoming

UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgate

operation(ifprovided)intheeventofpowerfailure

2.05 Metal Finishes

CarOperatingpanel,Hallcallstations&phoneboxareavailablein_____brushedstainlesssteel_____BrushedBrass_____Black____VintageBronzePowdercoat.Standardfinishes

OptionalFinishselections:_____PolishedStainlessSteel____PolishedBrass____Nickel___OilRubbedbrass.Customfinishrequest_________________ 19

Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive

Page 20: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

2.06 Car Features:•Cabsizeupto18squarefeet

•7’0”interiorstandardcarheight;____7’11”optionalinteriorcarheightat“nocharge”;Customcarheights______to9’0”

Interior Car Wall styles

A.FlatveneerinteriorwallswithmatchingceilingandMatchingwoodcarsill__________

B.ShakerstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_________

C.InsetstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_______

D.RaisedstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill______

E.Customdesigninteriorwallpanels,ceiling&sill______

(Selectonestyleinteriorwallpanelfromabove.)

•Unfinishedplywoodfloorwithsillsetfor3/4”(flooringbyothers)

Customflooring____________________

•2energysavingrecessedwithblacktrimrings

•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)

OptionalRealhardwoodveneeraccordiongatepanels_____________________Choosefromsamplekit.

Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.

2.07 Optional Features:

•Insetpanelcarwithmatchingceiling

•Raisedpanelcarwithmatchingceiling

•4recessedLEDlightswithblacktrimrings

•Factoryfinishedcarwallpanels_________________Stain#_________________Finish

•COPwithintegratedphonebox

•Customwoodinteriors

•Customfactoryfinishes(antiqued,distressed,&crackle)

•Greenmaterialalternativesandfinishesforcarinteriors

•Scissorgate

•Hardwoodveneeraccordiongate

•Clearpanelaccordiongate_______Allpanels________3centerpanels

•Autogateoperator(availableforusewithaccordiongateonly)

•3/4”finishedorunfinishedfactoryinstalledhardwoodcarflooring

•Factoryflooringinsertfor1/4”flooringbyothers

•Buffersprings(requiresminimumof10”pitdepth)

•Upperandlowerfinallimits,inadditiontoNormalupanddownlimits

•KeyswitchforCOPandhallstations

•750#carcapacity

20

Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive

Page 21: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

3.01 Work By Others:Theinstallationoftheelevatorandits’hardwareistheresponsibilityoftheElevatorContractor.Theinstallationandpreparationofa suitable hoistway, main power, door installation, pit construction and structural support are Work by Others

A. Hoistway shall be constructed from dimensional lumber, concrete or concrete block to support loads listed in the shop drawings with elevator rail reaction and pit loading consideration by others. The hoistway must be plumb and square within 1/4”toptobottomandsidetoside.

B.Allstructuralmemberlocationsinthehoistwaywallsareperthemanufacturer’sshopdrawings.

C.DoorcenterlinesarelistedontheshopdrawingsandareNOTtheCenterofthehoistway.

D.Mainpowerfromthemainbreakerpaneltotheelevatorlocationshownintheshopdrawingsis“byothers”.Equipment disconnects are included with the controller.

E.Installationofalivephonelineandoutlettotheelevatorlocation,asshownontheshopdrawings,iswork“byothers”.

F.MachineSpaceofapprox.4’x5’(orasrequiredbylocalAHJ)shallbeprovidedonalowerfloortocontainthecontrollerand pump unit. The requirements for this room will be shown on the shop drawings and coordinated with the various trades priortofabrication.(Seeshopdrawingsforlayout)

G.CompactmachinespacesasallowedbylocalAHJtopconformwithmanufacturersfabrication.(Seeshopdrawingsfor layout)

H. Pre-wire in the walls shall be coordinated with the builder prior to wall construction and drywall installation.

End of Section

21

Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive

Page 22: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

Part 1 General1.01 Scope

The scope of this section of work is the provision of and installation - residential elevator and all the necessary equipment required to fully complete the installation and coordinate between the other associated work required by other trades. The equipmentspecificationsarebasedontheSymmetryElevatingSolutionsproductdesign–Hydraulic1:2ropeddrivesystemwith cantilever sling.

1.02 References

A. Elevator equipment shall be designed, manufactured, installed and maintained in compliance and accordance with the followingNationalandlocalStandards:VerifywithlocalAHJ.

1.AmericanNationalStandardsInstitute–ANSIA117.13.ICC/IBC-InternationalBuildingCode-Chapter301.NFPA70- 1999NationalElectricalCode-NECChapter620”

2.AmericanSocietyofMechanicalEngineers-ASMEA17.1Part5.3PrivateResidenceElevators

3.ICC/IBC–InternationalBuildingCodesA117.1

4.NFPA70-1999NationalElectricalCode–NEC

1.03 Quality Assurance

A. Elevator equipment shall be designed and tested to meet or exceed the above standards and provide the following specificcomponents.AllloadratingsandsafetyfactorsshallmeetorexceedthosespecifiedbylocalAHJandbecertifiedby an independent professional engineer.

B.ElevatorInstaller/contractorshallbecertifiedtoinstalltheequipmentbytheManufacturerandhavetheappropriate Local, State or National certifications to install this specific style of equipment. A minimum of 10 years industry experience is required to perform this type work including product and public liability insurance. Copies of current Certificates of Insurance shall be provided with the contract prior to the start of work.

C.ElevatorInspectionshallbeperformedpriortoturnovertoowner.InspectionshallbeperformedbythelocalAHJora competentpersontrainedtoperformthistypeinspectiontocomplywithAMSEA17.2asitrelatestopart5.3Private Residence Elevators.

1.04 Warranty

A.TheManufacturershallwarrantycomponentpartsoftheSymmetryElevatingSolutionsequipmentforaperiodofthree(3)yearsfromcompletionofelevatorinstallation.(SubmitWarrantydetailswithOwnersManual)

B.AqualifiedMaintenanceProgram,complyingwiththemanufacturer’srecommendedmaintenanceschedule,isrequiredduringthethree(3)yearperiodinordertomaintainthewarranty.

2.01 Product

General:

•Travel:Maximumof50’(minimum12”betweenstops)Actualtravel:_________feet______inches

•Speed:40FPM

•LoadCapacity:950#(upto50’oftravel)

•Overhead:Minimumof8’(96”)

•Pitdepth:6”minimum

•FloorsServed____2____3____4____5____6

•Cabentrance______Singleopening______Oppositeopenings_______90degree/Adjacentopenings

•Threeyearlimitedpartswarranty

22

Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic

Page 23: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

2.02 Mechanical EquipmentMechanicalEquipmentandDrive:1:2RopedHydraulic

•Modular61/4#T-railstructure

•Carframeassembly:Cantilever

•208/230VAC,60Hz,15ampsinglephasepowersupplyformotorcontroller

•120VAC,60Hz,15ampsinglephasepowersupplyforlighting

•(2)3/8”7x19galvanizedaircraftcable(14400#breakingstrength)withwedgeropeshackles

•80mmdiameterpiston/102mmdiametercylinderincl.1”-3/4”reducerbushing

•208/230,3H.P.submersedmotorwith2-speedvalveassembly(1750RPM,17FLAmps)-Manualdownvalveforemergencylowering

•ScrewPump(300micronscreen)

•Positivepressureswitch

*Code compliant electrical disconnects included

2.03 Safety Devices:

•Slackropesafetydevice

•Rupturevalve(type“C”safety)

•Motorcontrollersupplydisconnect(locatedincontroller)

•Carlightsupplydisconnect(locatedincontroller)

•Pitstopswitch

•Cartopstopswitch

•In-caremergencystopswitchandalarm

•Safetyswitchforcargate(s)

•Batterybackupemergencycarlightsandalarm

•Electromechanicalhoistwaydoorinterlocks(doorsbyothers)

•UninterruptiblePowerSupply–(UPS)forcarloweringandautomaticgateoperation(ifautogateoperatorprovided)inthecaseofpowerfailure(toallowemergencylowerofcabincaseofmainpowersupply)

2.04 Controls:

•ProgrammableLogicController(PLC)

•Non-selectivecollectiveautomaticoperation

•SelfDiagnosticSystemwithdigitaldisplay(ateachlandingandincar)

•CarOperatingPanel(COP)withLEDfloorpositionindicator–Finishesseesection2.05

•Hallstationswithcallbuttonandcararrivalindicator.–Finishesseesection2.05

•Recessedphoneboxinsamefinishabove(phonejackincluded)–Finishesseesection2.05

•Automaticcarlighting

•Singlefloordesignatedcarhoming

•Lowoilruntimer

23

Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic

Page 24: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

2.05 Metal Finishes:CarOperatingpanel,Hallcallstations&phoneboxareavailablein_____brushedstainlesssteel_____BrushedBrass_____Black____VintageBronzePowdercoat.Standardfinishes

OptionalFinishselections:_____PolishedStainlessSteel____PolishedBrass____Nickel___OilRubbedbrass.Customfinishrequest_________________

2.06 Car Features:•Cabsizeupto18squarefeet

•7’0”interiorstandardcarheight;____7’11”optionalinteriorcarheightat“nocharge”;Customcarheights______to9’0”

Interior Car Wall styles

A.FlatveneerinteriorwallswithmatchingceilingandMatchingwoodcarsill__________

B.ShakerstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_________

C.InsetstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_______

D.RaisedstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill______

E.Customdesigninteriorwallpanels,ceiling&sill______

(Selectonestyleinteriorwallpanelfromabove.)

•Unfinishedplywoodfloorwithsillsetfor3/4”(flooringbyothers)

Customflooring____________________

•2energysavingrecessedwithblacktrimrings

•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)

OptionalRealhardwoodveneeraccordiongatepanels_____________________Choosefromsamplekit.

Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.

2.07 Optional Features:

•Insetpanelcarwithmatchingceiling

•Raisedpanelcarwithmatchingceiling

•4recessedLEDlightswithblacktrimrings

•Factoryfinishedcarwallpanels_________________Stain#_________________Finish

•COPwithintegratedphonebox

•Customwoodinteriors

•Customfactoryfinishes(antiqued,distressed,&crackle)

•Greenmaterialalternativesandfinishesforcarinteriors

•Scissorgate

•Hardwoodveneeraccordiongate

•Clearpanelaccordiongate_______Allpanels________3centerpanels

•Autogateoperator(availableforusewithaccordiongateonly)

24

Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic

Page 25: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

•3/4”finishedorunfinishedfactoryinstalledhardwoodcarflooring

•Factoryflooringinsertfor1/4”flooringbyothers

•Buffersprings(requiresminimumof10”pitdepth)

•Upperandlowerfinallimits,inadditiontoNormalupanddownlimits

•KeyswitchforCOPandhallstations

•750#carcapacity

3.01 Work By Others:Theinstallationoftheelevatorandits’hardwareistheresponsibilityoftheElevatorContractor.Theinstallationandpreparationofa suitable hoistway, main power, door installation, pit construction and structural support are Work by Others

A. Hoistway shall be constructed from dimensional lumber, concrete or concrete block to support loads listed in the shop drawings with elevator rail reaction and pit loading consideration by others. The hoistway must be plumb and square within 1/4”toptobottomandsidetoside.

B.Allstructuralmemberlocationsinthehoistwaywallsareperthemanufacturer’sshopdrawings.

C.DoorcenterlinesarelistedontheshopdrawingsandareNOTtheCenterofthehoistway.

D.Mainpowerfromthemainbreakerpaneltotheelevatorlocationshownintheshopdrawingsis“byothers”.Equipment disconnects are included with the controller.

E.Installationofalivephonelineandoutlettotheelevatorlocation,asshownontheshopdrawings,iswork“byothers”.

F.MachineSpaceofapprox.4’x5’(orasrequiredbylocalAHJ)shallbeprovidedonalowerfloortocontainthecontrollerand pump unit. The requirements for this room will be shown on the shop drawings and coordinated with the various trades priortofabrication.(Seeshopdrawingsforlayout)

G.CompactmachinespacesasallowedbylocalAHJtopconformwithmanufacturerslayout.(Seeshopdrawingsfor layout)

H. Pre-wire in the walls shall be coordinated with the builder prior to wall construction and drywall installation.

End of Section

25

Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic

Page 26: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428

AtSymmetryweareseriousaboutSAFETY!That’swhywe use only the best. The Relialign series by Honeywell, electromechanical door interlock holds the door in place and prevents it from being opened when not desired. A number of design features contribute to its enhanced safety, reduction of nuisance stoppages and call-backs, as well as simplified wiring and installation. A Honeywell MICRO SWITCH is used to indicate door closure, providing an extra level of reliability.

Reliability and smooth operations are also enhanced by use of a metal latch that is less susceptible to bending and breakage than plastic. The lack of open or exposed contactsminimizesthepossibilityofownersmakingmanualadjustments.Finally,theengagementofthelatchinitiates electrical contact.

Thesnapactioncammechanismrequireslessadjustmentsetup time and reduces door movement that could lead to a nuisance shutdown. Connection options include a 6-pinterminalstriporaCat5-pinconnector,simplifyinginstallation. The Relialign Series is designed to work seamlessly with your Symmetry elevator.

ComplianttoASMEA17.1Standard104,andCSA-B44.1

Standard Features• Manualoverrideforeasyactivationwithoutuserhazard• Twowayseparatemechanicalactionstoindicatedoor closure • Ruggedplasticmoldedhousing• Metallatch,latchengagementminimizesnuisancestoppage• Internalsolenoidcontrol• Noopenorexposedcontacts • Doorclosureretentioncamtoholddoorwithminimallatch- to-interlock play• Seriesorparallelwiringoptionforthedoorclosedanddoor locked switches• 6-pinterminalstriporCat5-pinconnectionoptions• Configurableproductplatform • UniversalvoltageforACandDCapplications

Design Features

• Thermoplasticcoveroffersdurabilityaswellasaesthetically appealingdesign(fixturematchingcoversavailable)• MICROSWITCHusedtoindicatedoorlockedwhenlatch rotates cam• MICROSWITCHusedtomonitordoorclosure,newdesign location harder to tamper or defeat• CustomsolenoiddesignsoffersuniversalvoltageforACor DC• Newentryforwiringonbacksideofinterlockhelpskeep wiring neat and out of sight • Manualoverridefeatureasrequiredbycertainapproval agencies • MICROSWITCHcontrollingsolenoid,reducespower consumption and complexity of host controller• Honeywell’sreliablecamdesignprovidespositivesnap action, new material provides more pull force • Stainlesssteellatchengagementholdsthedoorsecurely closedtominimizealignmentissues/nuisancestoppages

26

SECURE LOCK II

Page 27: Residential Elevator Planning Guide

SymmetryElevator.com | 877-375-1428 27

Contractor Site Notes

Hoistway Layout Notes

Page 28: Residential Elevator Planning Guide