2 REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 [email protected] www.reotemp.com Established in 1965 and located in San Diego, California, REOTEMP Instrument Corpora- tion is recognized as a leading manufacturer of pressure and temperature instrumentation. REOTEMP provides bimetal thermometers, pressure gauges, diaphragm seals and related accessories to a variety of process markets worldwide. Recognized for exceptional customer service, on-time deliveries and innovative engineering services, REOTEMP is an ISO 9002 certified manufac- turer. We are dedicated to continuous improve- ment, on-time deliveries, high quality products, and exceptional customer satisfaction. Waste Water Compost Military Dairy Power Generation Refrigeration And More! Table of Contents Bimetal Thermometers General Bimetal Specifications Page 3 3”, 4” & 5” Back Connection Page 4 3”, 4” & 5” All-Angle Connection Page 5 3”, 4” & 5” Bottom Connection Page 6 Heavy-Duty Navy Thermometer Page 7 Dual Mode Thermometer (DMT) Page 8-9 OEM Thermometers Page 10 Laboratory Thermometers Page 11 Compost Thermometers Page 11 Sanitary Bimetal Thermometer Page 12 Bimetal Thermometer Accessories and Ranges Page 13 Thermowells Threaded Type (1/4” elements) Page 14 (3/8” elements) Page 24 Sanitary Type Page 14 Flanged Type Page 15 Filled System Thermometers Industrial Glass Thermometer Page 16 Vapor Actuated Remote Thermometers Page 17-19 Gas Actuated Remote Thermometers Bourdon Tube Type Page 21-24 Direct-Drive Type Page 25-27 Digital Thermometers Page 28 RTD’s & Thermocouples Page 29-32 Sanitary RTD’s Page 33-34 Surface Thermometers Page 35 Pocket Thermometers Page 35 Warranty Back Page Markets Served REGISTERED REGISTERED Oil, Gas & Petrochemical Pharmaceutical Food & Beverage Paper & Pulp Mining Utilities Marine

Upload: others

Post on 21-Jan-2022

10 views

Category:

Documents


0 download

TRANSCRIPT

2

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Established in 1965 and locatedin San Diego, California,REOTEMP Instrument Corpora-tion is recognized as a leadingmanufacturer of pressure and temperatureinstrumentation. REOTEMP provides bimetalthermometers, pressure gauges, diaphragmseals and related accessories to a variety ofprocess markets worldwide. Recognized forexceptional customer service, on-time deliveriesand innovative engineering services,REOTEMP is an ISO 9002 certified manufac-turer. We are dedicated to continuous improve-ment, on-time deliveries, high quality products,and exceptional customer satisfaction.

Waste WaterCompostMilitaryDairyPower GenerationRefrigerationAnd More!

Table of Contents

Bimetal ThermometersGeneral Bimetal Specifications Page 33”, 4” & 5” Back Connection Page 43”, 4” & 5” All-Angle Connection Page 53”, 4” & 5” Bottom Connection Page 6Heavy-Duty Navy Thermometer Page 7Dual Mode Thermometer (DMT) Page 8-9OEM Thermometers Page 10Laboratory Thermometers Page 11Compost Thermometers Page 11Sanitary Bimetal Thermometer Page 12Bimetal Thermometer Accessoriesand Ranges Page 13

ThermowellsThreaded Type (1/4” elements) Page 14

(3/8” elements) Page 24Sanitary Type Page 14Flanged Type Page 15

Filled System ThermometersIndustrial Glass Thermometer Page 16Vapor Actuated

Remote Thermometers Page 17-19

Gas Actuated Remote ThermometersBourdon Tube Type Page 21-24Direct-Drive Type Page 25-27

Digital Thermometers Page 28

RTD’s & Thermocouples Page 29-32

Sanitary RTD’s Page 33-34

Surface Thermometers Page 35

Pocket Thermometers Page 35

Warranty Back Page

Markets Served

R E G I S T E R E DR E G I S T E R E D

Oil, Gas & PetrochemicalPharmaceuticalFood & BeveragePaper & PulpMiningUtilitiesMarine

3

Specifications – Bimetal Dial ThermometersDial Sizes: 1 1/8”, 1 3/4” 2 3/8”, 3” 4” 5”Stem Length: Between 2” and 80”Stem Diameters: 1/4” (standard),also available 5/16”, 3/8”.Heads, bezels, mounting bushing, stems:All Models 300 series SSOperating Conditions: The temperature of thehead should not be allowed to exceed 200° F (150°F if silicone filled). Stems should not be exposed tocontinuous temperatures exceeding 50% over-range, or 800° F.Hermetic seal: All 3”, 4”, and 5” models (exceptDM4) are hermetically sealed per ASME B40.3.Pointed Stems: Optional on all models. Excellentfor probing asphalt, compost, soil, frozen foods orother semi-solid materials.Dials: Anodized aluminum. Black marks and num-bers with satin matte finish background.

Crystals: Optically clear strong glass.Optional: Unbreakable clear plastic: all models (Notrecommended for ranges over 500° F).Optional: “Shatterproof” tempered glass (3”, 4”, and5” models).Accuracy: All Models are guaranteed accurate towithin plus or minus 1% of the full scale (Grade Aper ASME B40.3). Temperature readings arestabilized within 40 seconds.Immersion: For correct temperature measurement,the stem of all Models in all ranges must be im-mersed 2 inches in liquid, and 4 inches in gas exceptfor 0 to 100° F, 25 to 125° F, and 0 to 50° C whichrequire 3 1/2 inches in liquid and 5 inches in gas.Mounting Connections: 1/2” NPT (std. on 3”, 4”,5” models), 1/8” NPT, 1/4” NPT, 3/8” NPT, 3/4” NPT,3/8”-24” NF, Plain or Reset Bushing, 1/2” NPTUnion, 1/2” BSPT, BSPP Adapters.

ThermowellsThermowells should be used whenever the stem or bulb would be exposed to pressure, corrosion, orshear forces. Thermowells also make it possible to remove the thermometer without losing pressure orcontents. (See pages 14-15 for more details)

O.E.M. ApplicationsIf you are an Original Equipment Manufacturer and plan to incorporate the REOTEMP Thermometer in yourfinished product for resale, special ranges or special dials can be made to suit your particular requirements.Such specials can bear your own company name and/or trademark on the dial. The quality, appearance,and performance of a REOTEMP Thermometer will complement and enhance your equipment.

SpecificationsBimetal Thermometers

R E G I S T E R E DR E G I S T E R E D

4

AA =

BB =

CC =

RR =

SS =

CN =

025 =

040 =

060 =

090 =

120 =

150 =

180 =

240 =

300 =

360 =

1 =

4 =

5 =

X =

B =

C =

L =

M =

F23F55*F43F47F63F67F81F85

C23C55*C43C47C59C67C81C85

PS =

SF =

SS =

F3 =

PC =

PY =

TG =

MM =

Industrial 3”, 4”, 5” DialBack Connected(Angle Form)

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com

Bimetal Thermometers

REOTEMP Angle Form thermometers are ideal forlocal, eye-level temperature readings in mostprocess applications.

D23D55*D43D47D63D67D81D85

&&&&&&&&

Standard Features

• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset

• Silicone Fillable for Vibration

AA 060 1 F43 SF

-Intermediatelengths available

up to 80”

-Specify length ininches + tenths

For more information onSanitary Thermometers

see page 12

How to Order

Model A 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)

4" 1/4" NPT Silicone Fill Model B (max temp 550°F)(5" dial, reset) 6" 3/4" NPT adapter

316 SS StemModel C 9" Plain Hex Bushing(4" dial, reset) (no threads) 3/8" dia. Stem

12"1/2" BSPT Acrylic Window

Model R 15"(3" dial, no reset) Polycarbonate

18" 1-1/2" Tri-Clamp WindowModel S (5" dial, no reset) 24" 2" Tri-Clamp Tempered Glass

WindowModel CN 30" 3/4" Tri-Clamp(4" dial, no reset) Max/Min Pointer

36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C

200 TO 1000°F 100 TO 500°C*-Not available in 2.5" stem.*-Other sizes available

0 TO 150°C 0 TO 250°C

-40 TO 70°C

0 TO 400°C 100 TO 500°C

OptionsTemperature RangesSee pg.13 for a full list.

Fahrenheit Ranges-40 TO 160°F

Sanitary*

Dual F/C Ranges

0 TO 250°F 50 TO 300°F 50 TO 500°F150 TO 750°F

200 TO 1000°FCelsius Ranges

0 TO 50°C 0 TO 100°C

For Thermowellssee pg. 14

Models StemLength

Standard Models

-20 TO 120°C

Standard Threaded*

Connection

25 TO 125°F 0 TO 200°F

Non-Reset Models

5

Industrial 3”, 4”, 5” DialAdjustable Angle Bimetal Thermometers

REOTEMP All-Angle thermom-eter allows for easy temperaturemonitoring from any position.

Standard Features

• Complete 180° Adjustability• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset• Silicone Fillable for Vibration• 360° Case Rotation

LL =

MM =

JJ =

025 =

040 =

060 =

090 =

120 =

150 =

180 =

240 =

300 =

360 =

1 =

5 =

U =

C =

L =

M =

F23F55*F43F47F63F67F81F85

C23C55*C43C47C59C67C81C85

PS =

SF =

SS =

F3 =

PC =

PY =

TG =

MM =D23D55*D43D47D63D67D81D85

&&&&&&&&

-Intermediatelengths available

up to 80”

-Specify length ininches + tenths

LL 060 1 F43 SF

For more information onSanitary Thermometers see

page 12

How to Order

Model L 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)

4" 3/4" NPT adapter Silicone Fill Model M (max temp 550°F)(4" dial, reset) 6" 1/2" NPT Union

316 SS StemModel J 9"(5" dial, reset) 1-1/2" Tri-Clamp 3/8" dia. Stem

12"2" Tri-Clamp Acrylic Window

15"3/4" Tri-Clamp Polycarbonate

18" Window

24" Tempered Glass Window

30"Max/Min Pointer

36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C

200 TO 1000°F 100 TO 500°C

Dual F/C Ranges

Fahrenheit Ranges

Temperature RangesSee pg.13 for a full list.

Options

100 TO 500°C 0 TO 400°C 0 TO 250°C 0 TO 150°C -20 TO 120°C

Standard Models

StemLengthModels

0 TO 100°C 0 TO 50°C

0 TO 250°F

-40 TO 160°F

50 TO 300°F

Connection

Standard Threaded

Sanitary*

0 TO 200°F 25 TO 125°F

-40 TO 70°CCelsius Ranges

200 TO 1000°F150 TO 750°F 50 TO 500°F

For Thermowellssee pg. 14

*-Other sizes available *-Not available in 2.5" stem.

R E G I S T E R E DR E G I S T E R E D

6

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com

Industrial 3”, 4”, 5” Dial Bottom Connected(Straight Form)

Bimetal Thermometers

XR =

YY =

VR =

XX =

YN =

VV =

025 =

040 =

060 =

090 =

120 =

150 =

180 =

240 =

300 =

360 =

1 =

4 =

5 =

C =

L =

M =

F23F55*F43F47F63F67F81F85

C23C55*C43C47C59C67C81C85

PS =

SF =

SS =

F3 =

PC =

PY =

TG =

MM =

99 =

33 =

12 =

D23D55*D43D47D63D67D81D85

XR 060 1 F43 SF

REOTEMPStraight Formthermometersare ideal forside and elevated installationson tops or sides of tanks orpipes.

Standard Features

• Bottom, Top, Right or Left Side Mounting• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset• Silicone Fillable for Vibration(Standard)

&&&&&&&&

For more information onSanitary Thermometers

see page 12

-Intermediatelengths available

up to 80”

-Specify length ininches + tenths

How to Order

Model XR 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)

4" 1/4" NPT Silicone Fill Model Y (max temp 550°F)(4" dial, reset) 6" 3/4" NPT adapter

316 SS StemModel VR 9"(5" dial, reset) 1-1/2" Tri-Clamp 3/8" dia. Stem

12"2" Tri-Clamp Acrylic Window

Model X 15"(3" dial, no reset) 3/4" Tri-Clamp Polycarbonate

18" WindowModel YN (4" dial, no reset) 24" Tempered Glass

WindowModel V 30"(5" dial, no reset) Max/Min Pointer

36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 9 O'Clock Stem 0 TO 200°F 0 TO 100°C (left side) 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 3 O'Clock Stem 50 TO 500°F 0 TO 250°C (right side)150 TO 750°F 0 TO 400°C

200 TO 1000°F 100 TO 500°C 12 O'Clock Stem(top mount)

Models StemLength

Standard Models

-20 TO 120°C

Standard Threaded*

Connection

25 TO 125°F 0 TO 200°F

Non-Reset Models

Sanitary*

Dual F/C Ranges

0 TO 250°F 50 TO 300°F 50 TO 500°F150 TO 750°F

200 TO 1000°FCelsius Ranges

0 TO 50°C 0 TO 100°C

-40 TO 70°C

0 TO 400°C 100 TO 500°C

OptionsTemperature RangesSee pg.13 for a full list.

Fahrenheit Ranges-40 TO 160°F

*-Not available in 2.5" stem.*-Other sizes available

0 TO 150°C 0 TO 250°C

R E G I S T E R E DR E G I S T E R E D

StemLength

.75

.62

1/4" dia

Reset 3" dia (Model XR)

4" dia (Model Y) 5" dia (Model VR)

7

Heavy-Duty“Navy” Type

Bimetal ThermometersSilicone-Filled Thermometers

Specify option “SF” at the end of any 3”, 4” or 5” dial bimetal thermometer.(e.g., Model AA-040-1-F47-SF). See pg. 4-6

Heavy-Duty Navy TypeBimetal Thermometers

Any REOTEMP 3”, 4” or 5” dial bimetal thermometer (except Model DM4)can be silicone filled, in any stem length, and any temperature range up to550° F. (Silicone filling with ranges over 550° F not recommended.) Allsilicone-filled thermometers come with a durable polycarbonate crystal.

REOTEMP Silicone-filled thermometers are offered for severe industrial applications,where vibration is a problem. Silicone dampening prolongs instrument life by prevent-ing wear and fatigue in the instrument’s internal parts. The silicone also improvesreadability by reducing pointer flutter, and promotes faster temperature response.

Standard Features

• 3” Dial – Bimetal Actuation• Heavy Duty – Vibration and Shock Resistant• Stainless Steel – Sealed Construction• Plastic Crystal• External Reset is Standard• 1% Accuracy• Fits in 5” Scale “Submarine” Thermometer Well• 3/4” – 28 UN2A Union Connection – (to be used in thermowell)

AN2=AN4=AN6=

XN2=XN4=XN6=

F23F25F43F53F63F65F69F73

12"

12

"DIA.

34" STEM

LENGTH STEMLENGTH

1 5/16"

1.05"DIA.

1. Model2. Range

ThermometerWells STN2B

STN4BSTN6B

STN2SSTN4SSTN6S

STN2SSSTN4SSSTN6SSSWN2SSSWN4SSSWN6SS

Back (Angle) Form

Straight Form

Brass 304 SS 316 SS2" 3 1/4"4" 5 1/4"6" 7 1/4"2" 3 5/16"4" 5 5/16"6" 7 5/16"

Class A(3/4" NPT)

Class W(Socket Weld)

Model No.WellClass

ThermometerStem Length

Well Length(overall)

2” -40 TO 120° F in 2° divs.*4” -40 TO 180° F in 2° divs.6” 0 TO 200° F in 2° divs.

20 TO 240° F in 2° divs. 50 TO 300° F in 2° divs.

2” 50 TO 400° F in 5° divs.4” 50 TO 550° F in 5° divs.6” 50 TO 750° F in 10° divs.

-50 TO 50° C in 1° divs.*-10 TO 110° C in 1° divs. 0 TO 150° C in 2° divs. 0 TO 200° C in 2° divs. 0 TO 300° C in 5° divs.

M odels RangesFahrenheit Ranges

Celsius Ranges

*-4" M inimum stem length(on straight, left, or right side form s only)

Back Angle Form

Straight Form

Note: m inim um im m ersion length is 2” C13

C53C59C65C69

How to Order

How to Order

A & W Wells

8

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Bimetal ThermometersDual-Mode Thermometer

REOTEMP DUAL MODE THERMOMETER (model DMT) is a convenient, multipurpose indicator forlocal and remote temperature monitoring. This rugged dual-sensor system puts TWO SENSORS inONE THERMOWELL, and allows easy tie-in to process control. Both sensors are NIST traceable,and easily calibrated. Special sensor encapsulation and optional liquid filling make the DMT the mostrugged, durable instrument of its kind.

Bimetal Thermometer• Local easy-to-read Temperature Indication• Self-actuating, Dampened Bimetal Helix• Choice of three Dial Sizes, with Back, Bottom, or Adjustable Angle Connection• Hermetically Sealed per ASME B40.3• Thermometer is Easily Calibrated, and Field Replaceable• NIST Traceable Calibration

Thermocouple or RTD• Remote and Local Indication• Data Acquisition for Process Control• Choice of Connection Styles (see drawing below)• 4-20mA Transmitter Output Available

DMT Advantages:• Allows local and remote reading (Up to 1000°F) from one thermowell.• Bimetal dependability with RTD (or thermocouple) accuracy.• Redundant sensors for simple, effective calibration or spot checking without removing instrument from thermowell!• Easily installed in any standard thermowell.• Interchangeable with existing thermometer, RTD, Thermocouple.

Model DMT withScrew Cover TerminalHead, and Adjustable-Angle Head

with optional T/C Transmitter (HT)or with optiona RTD Transmitter (HR)

R E G I S T E R E DR E G I S T E R E D

9

Bimetal ThermometersDual-Mode Thermometer

Table 1 - Style & Stem Dia.

Table 2 - Stem Length

Table 6 - Thermowell (.385” & .260” bore)

TATCTBTLTMTJ

4A4C4B4L4M4J

02*04060912

1518243036

071072073074046047048049053054055056

171172173174146147148149153154155156

011012013014018019020021025026027028

111112113114118119120121125126127128

MPMC

EC

HAHTHR

Table 4 - Sensor

Case and Bezel: 304 SS (316 SS Available)Case Style: Back, Bottom or Adjustable Angle connection.Dial Size: 3”, 4” or 5”ProcessConnection: 1/2” NPT Standard, (1/2” NPT Union available)External Reset: Slotted Hex ScrewCrystal: Glass Standard, Plastic or Tempered Glass

optionalHermetic Seal: Bi-Metal Thermometer per ASME B40.3Stem: 304 SS, 0.375” O.D. (1/4” O.D. - specify

“DMT4”) Lengths from 2-1/2” to 36”RTD-T/C Encapsulation Sleeve (Pat.pending): 304 SSRTD:

Thermocouple: Type K grounded junction std. (Optional: typesT, E, J, or ungrounded.)

Connection: T/C plug, Mini connection head, or Standardscrew-cover connection head are available,Special customer requirements accommodated.

Ranges: Std. REOTEMP ranges and divisions to 1000F(500C)

Over Ranges: 50% over range to 550F, 1000F max.Accuracy: (+/-) 1% of full scaleThermowell: Model DMT fits any standard 0.385” bore

thermowell. (See table for Std. Models).Options: Silicone Case Fill for Vibration. (3/8” stem only)NOTE: Model DMT is intended for use ONLY in a thermowell. 3-A and NACE conformity available.

Model Style/Stem(Table 1)

Stem Length(Table 2)

Temp Range(Table 3)

Sensor(Table 4)

OutputConnection(Table 5)

Thermowell(Table 6)

* min. stem length 4” **continuous use over 800F not recommended.

Table 3-Temperature Range

F03F23F55*F43F47F53F63F65F69F79F85**

C03C23C55*C43C47C53C59C65C69C79C85**

D03D23D55D43D47D53D63D65D69D79D85**

Table 5 - Output Connection

TKTJTETTUKUJUEUTRCRK

100Ω (or 1000Ω optional) Platinum; 0.00385Ω/Ω/°C, 3-wire std.

DM TA 04 TK 046F24 MC

&&&&&&&&&&&

3/8" Stem 1/4" Stem3" Back Connected4" Back Connected5" Back Connected3" Adjustable-Angle4" Adjustable-Angle5" Adjustable-Angle

Code Description

Code Length Code Length2.5" 15"4" 18"6" 24"9" 30"

12" 36"

304 SS 316 SS 304 SS 316 SS4" 2.56" 4.59" 7.512" 10.54" 2.56" 4.59" 7.512" 10.54" 2.56" 4.59" 7.512" 10.5

1/2" NPT

3/4" NPT

1" NPT

1/4" Stem3/8 StemProcessConnection

StemLength

"U"Dim

DMT Specifications

Code DescriptionMini - Plug Receptacle (Thermocouple Only)Mini - Connection Head, w/screw terminals & protection head1/2" NPT Male Electrical Connection, w/Lead Wire

with Terminalwith 4-20 mA Transmitter (for Thermocouple)with 4-20 mA Transmitter (for RTD)

Aluminum screw - Cover Head w/3/4" NPT Conduit Connection

CodeThermocouple, Type K (grounded)Thermocouple, Type J (grounded)Thermocouple, Type E (grounded)Thermocouple, Type T (grounded)Thermocouple, Type K (ungrounded)Thermocouple, Type J (ungrounded)Thermocouple, Type E (ungrounded)Thermocouple, Type T (ungrounded)RTD, 100 ohm, 3-wire max. RTD, 1000 ohm, 3-wire 550°F

Description

Code Degrees F Code Degrees C Code-100 TO 100°F -70 TO 70°C -100 TO 100°F -70 TO 70°C 40 TO 160°F -40 TO 70°C 140 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 0 TO 250°F -20 TO 120°C 20 TO 240°F -10 TO 110°C 20 TO 240°F -10 TO 115°C 50 TO 300°F 0 TO 150°C 50 TO 300°F 10 TO 150°C 50 TO 400°F 0 TO 200°C 50 TO 400°F 10 TO 200°C 50 TO 550°F 0 TO 300°C 50 TO 550°F 10 TO 290°C 100 TO 800°F 50 TO 400°C 100 TO 800°F 40 TO 400°C 200 TO 1000°F 100 TO 500°C 200 TO 1000°F 100 TO 500°C

Degrees F & C

How to Order

* available only with3/8” dia. stem.

Block

10

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

1/4" dia

1.16 dia

.33 dia

.29

.17

.24

StemLength

.33 dia

.30

.17

.24

StemLength

1.70 dia

1/4" dia

Model Q - 1 5/32” Dial Model G - 1 11/16” Dial

Bimetal ThermometersOEM Dial Bimetal Thermometers

REOTEMP OEM Thermometers (Models Q, G, and H) are the perfect choice for equipment with limited space andrequiring a rugged, dependable and economical temperature sensor. Available with a wide variety of mounting threads.

Mounting Thread Options

.24

StemLength

1/4" dia

2.37 dia

.36

Model H - 2 3/8” Dial

QQ 025 2 F43 PS

1/4” Dia.

QQ =

GG =

HH =

QP =

GL =

HL =

025 =

040 =

060 =

090 =

120 =

150 =

180 =

240 =

300 =

360 =

2 =

1 =

3 =

4 =

6 =

7 =

8 =

F23F55*F43F47F63F67F81F85

C23C55*C43C47C63C67C81C85

D23D55*D43D47D63D67D81D85

&&&&&&&&

PS =

SS =

PC =

PB =

How to Order

R E G I S T E R E DR E G I S T E R E D

Model Q 2.5" Plain Bushing (std.) Pointed Stem(1-1/4" dial)

4" 1/2" NPT 316 SS StemModel G(1-3/4" dial) 6" 3/8-24 NF Plastic Window

(straight threaded)Model H 9" Plain Bushing(2-3/8" dial) 1/4" NPT (non-reset)*

12"1/8" NPT

Model QP 15"(1-1/4" dial) 3/8" NPT5" Stem 18"

Hex Reset BushingModel GL 24"(1-3/4" dial)8" Stem 30"

Model HL 36" -40 TO 160°F -40 TO 70°C(2-3/8" dial) 25 TO 125°F 0 TO 50°C8" Stem 0 TO 200°F 0 TO 100°C

0 TO 250°F -20 TO 120°C 0 TO 300°F 0 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C

200 TO 1000°F 100 TO 500°C

*for lab and test Models only

Options

OEM Models Fahrenheit Ranges

Models StemLength Connection Temperature Ranges

(See pg 13 for full list)

0 TO 300°F 50 TO 500°F150 TO 750°F

-40 TO 160°F 25 TO 125°F 0 TO 200°F 0 TO 250°F

200 TO 1000°FCelsius Ranges

Lab & Test Models -40 TO 70°C 0 TO 50°C

0 TO 100°C -20 TO 120°C 0 TO 150°C 0 TO 250°C 0 TO 400°C 100 TO 500°C

Dual F/C Ranges

*-Other sizes available *-Not available in model Q.

-Intermediatelengths available

up to 80"

-specify length ininches + tenths

1/2” NPT 3/8” NPT 3/8-24 UNF 1/4” NPT 1/8” NPT9/16” HEXBUSHING

11

Compost ThermometersBimetal Thermometers

Standard Features

• Hermetically sealed — will not fog• Pointed stem for easy insertion• Rugged, all stainless construction• Heavy duty 5/16” diameter stem• Easy to read 3” diameter dial• Unbreakable plastic crystal• °F & °C scales available

(Std. range, 0 - 200°F)• Accuracy +/- 1% of scale• Stem lengths up to 72” available

8"Stem

1.70" dia

.30

.24

1/4" dia

9/16" HEXRE-SET BUSHING1/4" dia

9/16" HexRe-set Bushing

6"Stem

1.16" dia

.30

.24

.24

8" Stem

1/4" dia

2.37" dia

.36

9/16" HexRe-set Bushing

Model QP - 1 5/32” Dial Model HL - 2 3/8” DialModel GL - 1 11/16” Dial

For Composting Food andYard Waste

Used By:

Waste Treatment Plants.City, State and FederalRecycling Programs.Farms and UniversityCompost Programs.Compost Chicken, Hogand Fish wastes.Mushroom Farms.

Standard Model: A36 PF (36” Pointed Stem, 0/200° F)Also Backyard Compost Thermometer:

G20P (2” Dial, 20” Stem, 0/200° F)

REOTEMP Laboratory Thermometers (QP, GL & HL) are ideal for testing and spot checking local temperatures in avariety of critical process or lab applications. Pointed stems are available for insertion in semi-solids such as soil, meat, etc.

Bimetal ThermometersHand-held Laboratory Thermometers

Ideally suited for monitoring interiortemperature of compost bins orwindrows.

Applications

Specify Model and Range (see table, pg. 10), Example: QP - F43

(with point - Model QPP) (with point - Model GLP) (with point - Model HLP)

How to Order

12

Sanitary Bimetal ThermometersSani-Temp

REOTEMP SANI-TEMP Bimetal Thermometer is specially designed for di-rect insertion into sanitary process applications when a standard thermowellis not specified or the process environment is not exposed to pressure. TheSANI-TEMP provides a quick temperature response and will mate with exist-ing process connections. The SANI-TEMP is ideal for the food, beverageand pharmaceutical industries.

• Quick connect Tri-clamp design• Fast installation and removal• Hermetically sealed case• Ideal for CIP and SIP• Designed to meet 3A Sanitary standards• External Reset

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Specifications

Dial Size: 3” 4” 5”Wetted Parts: 316/316L polished stainlessCase & Ring: 300 series polished st. stl.Process Connection: Tri-clamp (standard),

Cherry-Burrell (optional)Windows: Glass- (standard) see option

tableOptional: Acrylic, Polycarbonate, or

Tempered Glass Silicone Filling available for Vibration

“C”Dia.

Tri-Clamp 3/4" 3" 2 1/2" -40 TO 160°F -40 TO 70°C(standard) 4" 25 TO 125°F 0 TO 50°C

1" or 1 1/2" 5" 4" 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C

2" 6" 20 TO 240°F -10 TO 110°C 50 TO 300°F 0 TO 150°C

2 1/2" 3" 9" 50 TO 400°F 0 TO 200°C4"

3" 5" 12"-40 TO 160°F -40 TO 70°C

15" 25 TO 125°F -5 TO 50°C 0 TO 200°F -10 TO 90°C

3" 0 TO 250°F -20 TO 120°C4" 20 TO 240°F -10 TO 115°C5" 50 TO 350°F 10 TO 150°C

50 TO 400°F 10 TO 200°C

OtherTypes

AvailableSee pg. 5

OtherStems

Available

Dual F/C Ranges

Farenheit Celsius

Temperature Range(See pg. 13 for a full list.)

FlangeType

SanitaryFlange Sizes

BimetalModels

StemLengths

Angle

BackConnected

BottomConnected

Adjustable

See pg. 4

See pg. 6

How to Order

Use “How to Order” Codes onpg. 4, 5, 6.

Specify Sanitary Connection.M =

C =

L =

A =

T =

A =C =B =

XR =Y =

VR =

L =M =J =

F23F55*F43F47F63F67F81F85

C23C55*C43C47C63C67C81C85

D23D55*D43D47D63D67D81D85

&&&&&&&&

How to Order

Stem LengthCustomer Specified

ThermometerHead

Sanitary Flange "C"see chart

14" dia

13

Sanitary Bimetal Thermometers

Bimetal ThermometersAccessories

Temperature Ranges

Code Description ModelMinimum or Maximumresettable pointer (one hand) 3”, 5”

Minimum and Maximumresettable pointer (two hands) 3”, 5”

Tempered Glass Lens 3”, 4”, 5”Plastic Lens AllSilicone Filled 3”, 4”, 5”Silicone Filled, food grade 3”, 4”, 5”Glycerine Filled 3”, 4”, 5”Pointed Stem All316SS Head and Bezel 3”, 4”, 5”316SS Stem All5/16” diameter stem 3”, 4”, 5”3/8” diameter stem 3”, 4”, 5”3/8” diameter aluminum sleeve 3”, 4”, 5”Teflon Coating (stem only) AllExternal Mounting Brackets G, HStainless Steel Tags AllPaper Tags AllNo Logo Dial AllBBQ Dial 3”

AccessoriesAS-86 Adapter Kit: permits

installation of bimetal thermometer in existingmercury-in glass-industrialthermometer thermowell.

HT Heat Transfer Compound(2 oz, 1 lb containers)

D3 Duct Flange (1/2" NPT)CH T-27 spring handleCP Pan Clip

CalibrationCC Certificate of ConformanceC1 1 Point Calibration

CertificateC3 3 Point Calibration

Certificate

Also available on request – Custom dials, special ranges, special configurations.

Options

F03F07F11F21F23

F19F31F35F55F37F39F43F45F47F53F63F65F67F69F79F81F85

C03C07C11

C23

C19C31

C55C37

C43

C47C53C63C65C67C69C79C81C85

D03

D11

D23

D55D37D39D43

D47D53D63D65D67D69

D81D85

MM

MATGPCSFSDGFPS3HSSF5S3F3TFMBTSTPNLBQ

Bimetal Temperature Range Master List - (Other ranges available on application. Y = available)

* = Minimum stem 4"** Includes all 3", 4", and 5" models (back, bottom, or all-angle)

R E G I S T E R E DR E G I S T E R E D

Code F Ranges Div Q G H 3,4,5** Code C Ranges DivQ G H 3,4,5** Code Q G H 3,4,5**-100/100F 2 Y Y Y -70/70C Y -100/100F & -70/40C Y Y Y-80/120F 2 Y Y -50/50C 1 Y Y Y-70/150F 2 Y -50/100C 2 Y Y Y -50/210F & -50/100C Y-40/120F 2 Y-40/160F 2 Y Y Y Y -40/70C 1 Y Y Y Y -40/160F & -40/70C Y Y Y

-50/200C 2 Y-50/300F 2 Y Y Y -40/160C 2 Y-20/120F 2 Y Y -20/40C* 1 Y0/100F* 1 Y25/125F* 1 Y Y Y Y 0/50C* 1/2 Y Y Y 25/125F & -5/50C* Y Y Y0/140F 2 Y 0/60C* Y 0/140F & -15/60C Y Y0/150F 1 Y Y 0/150F & -20/70C Y0/200F 2 Y Y Y Y 0/100C 1 Y Y Y Y 0/200F & -10/90C Y Y Y Y0/220F 2 Y Y Y0/250F 2 Y Y Y Y -20/120C 2 Y Y Y 0/250F & -20/120C Y Y Y

20/240F 2 Y Y Y -10/110C 1 Y Y Y Y 20/240F & -10/115C Y Y Y50/300F 2 Y Y Y Y 0/150C 1 Y Y Y Y 50/300F & 10/150C Y Y Y50/400F 5 Y 0/200C 2 Y Y Y Y 50/400F & 10/200C Y50/500F 5 Y Y Y Y 0/250C 2 Y 50/500F & 10/260C Y Y Y Y50/550F 5 Y Y 0/300C 2 Y Y Y Y 50/550F & 10/290C Y100/800F 10 Y Y Y 0/400C 5 Y Y Y150/750F 10 Y Y Y Y 50/400C 5 Y Y Y 150/750F & 70/400C Y

200/1000F 10 Y Y Y Y 100/500C 5 Y Y Y 200/1000F & 100/500C Y Y Y Y

Dual Ranges

14

Thermowells

Thermowells make it possible to remove instruments without dropping pressure or losing contents. Eachstainless Thermowell die stamped with type of material from which it is made.

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Features• Provides Sanitary Protection for Temperature Probes• All 316L Stainless Steel Construction• Fast Installation & Removal• Ideal for Food, Beverage, Biotech & Pharmaceutical Applications• Finish Exceeds Ra 32 max.• Exceeds 3A #4 Finish

STF-1.5-2.5STF1.5-4STF1.5-6STF1.5-9STF2-2.5STF2-4STF2-6STF2-9

STF2.5-2.5STF2.5-4STF2.5-6STF2.5-9STF3-2.5STF3-4STF3-6STF3-9

Example:1. Type:2. Thermometer Stem Length:3. Material:4. External Thread:

ST 4” 304 SS 3/4”

Sanitary Thermowells

“T” LagExtension

Type ST

Type LG

Models Material ExternalThread Options

"A" Dim "U" Dim 304 SS Socket-W eld 2 1/2" 1 5/8" W ell

4" 2 1/2" 316 SS6" 4 1/2" Optional: Tapered9" 7 1/2" Brass 1/2" NPT

12" 10 1/2" Straight15" 13 1/2" 1" NPT18" 16 1/2"

"A" Dim "U" Dim "T" Dim6" 2 1/2" 2"9" 4 1/2" 3"

12" 7 1/2" 3"15" 10 1/2" 3"18" 13 1/2" 3"24" 19 1/2" 3"

.385 Bore (for 3/8"

elements)

SantaryTri-Clamp

ST

LG(lagging)

Stem3/4" NPT

(Standard)

Carbon Steel

Threaded, for Bimetal Thermometers

Tri-ClampSize

"A" StemLengths Part No. "U" Dim "C" Dim

(Flange Dia.)2 1/2" 1 5/8"

4" 2 1/2"6" 4 1/2"9" 7 1/2"

2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"

2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"

2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"

3.6

(76mm)

4.7

(91mm)

(51mm)

2

(63mm)

2.5

1 1/2"

2"

2 1/2"

3"

How to Order Specify Part Number:

How to Order

1/2” MAX O.D.

.260 BORE

R E G I S T E R E DR E G I S T E R E D

15

SHANK STYLES

Thermowells

Flanged Well

Sanitary Well

Standard Stepped Shank

Order By Specifying:1. Type and Bore Dia.2. Thermometer Stem “A” Length or “U” dimension.3. Material.4. Shank Style.5. For Flanged Wells: -Flange Size and Rating.6. For Threaded Wells: -Process Thread (P).7. For Socket-Weld Wells: -Nominal Pipe Size.

How to Order

Socket-Weld Well

Straight Shank

TYPESStandard Threaded Wells

R E G I S T E R E DR E G I S T E R E D

Tapered Shank

3/8" DIA

(.250 DIA)

A

U

C

1/2" NPT

1/8"

1/4"

AELEMENT LENGTH

2-1/4

Q

BORE

UINSERTION LENGTH

1-1/4" dia

FLANGE SIZE & RATINGCUSTOMER SPECIFIED

1/4"

A

U

P

1-3/4"

Q1

1/4"BORE SIZEQ2

1/2" NPT

1.0A

1/2" NPT

P

(.75) BORE DIA

U

Q

(.50)

1/4"

Q1

Q2

Q

Q1

Q2

Type ElementLength Material Shank

StyleFlange Wells

Socket-Weld Wells

or (U-dim) Flange Sizeand Rating

Pipe SizeNom.

304 SS Stepped Example: Example:316 SS Straight 1 1/2", 150# 3/4" Pipe

Flanged Carbon Steel TaperedSocket Weld BrassSanitary Type 316L SS

MonelHastelloy BHastelloy C

TitaniumTantalum

Teflon

Externally Threaded(Standard Bimetal Type)

Call Factory for help specifying well, if needed

See Table pg. 14

16

Liquid-In-Glass ThermometerAll Angle Industrial

Case: Modern V-shape design with parts molded of GE Valox®polyester, in black textured finish. Heavy glass protected front firmlysecured by spring action.

Stem: Tapered bulb chambers are made of precision ground alumi-num. The tapered chamber forms a metal contact with matchingtaper in the sockets assuring maximum speed of response totemperature changes. Graphite is used as a conducting mediabetween bulb chamber and glass tube.

Locking Device: Adjustable case locknut and angle adjusting screwwork independently to provide full 360° positioning of thermometercase and stem.

Tube & Capillary: Mercury filled-magnifying lens “Red Reading”tube (Spirit Filled option available). Precision made to guaranteeaccuracy within 1% of scale range. Silicone shock mounting forlasting durability. When Mercury is not desired, alcohol-based spiritfill is available

Scale: 9" scale with white coated aluminum and permanently bakedbold black markings.

Applications: REOTEMP “All Angle” Industrial Thermometers areused in pipelines of all types, commercial building application(heating & cooling), process piping, tanks, boilers, etc.

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

9” Scale, All Angle with1 1/4”-18” Swivel Nut

INDUSTRIAL THERMOMETERS

RETORT THERMOMETERSFor Rubber Vulcanizers, Retorts,

Coolers, Kettles.9” Scale Straight or Angle Form,

3 ½” 304 SS Stem, with ¾ NPT 304 S.S. Hub.

9RA35F9RS35F9RA35C9RS35C9RA35FV9RS35FV

Separable Sockets¾” NPT External

SOC35BSOC06BSOC09B

SEN06BSEN09B

UH3B

SOC35SSOC06SSOC09S

SEN06SSEN09SUH3S

Specifications:

9VS359VS069VS09

9VX359VX069VX09

How to Order 016 SOC35B

Mercury Filled Spirit Filled3 ½"6"9"

Part #Stem

9VX35

STANDARD

411118212012016318324330

Code Range Divisions-40 TO 110°F 2°-10 TO 180°F 2°-20 TO 120°F 2° 0 TO 120°F 1° 0 TO 160°F 2° 30 TO 180°F 2° 30 TO 240°F 2° 30 TO 300°F 2°

Union Hubs

1. Part #2. Range Code3. AccessoriesShaded items normally instock.

StemLength

InsertionLength

Extension Neck

LengthBrass 304 SS

3 ½" 2 ½" -6" 5" -9" 8" -

6" 2 ½" 2 ½"

9" 5 ½" 2 ½"¾ NPT External Thread

Range Form Part #170/270°F & 0/30psi Angle170/270°F & 0/30psi Straight

80/130°C & 0/2 kg/cm2 Angle 80/130°C & 0/2 kg/cm2 Straight200/400°F & 0/200psi Angle200/400°F & 0/200psi Straight

A

U

U

AT

1"

17

REOTEMP remote Vapor actuated Thermometersare manufactured to the highest standards for awide range of uses and may be fitted into almostany temperature indicating application. Theseinstruments are ideal for remote reading, such aspanel installations, with capillary lengths of 1 to100 feet.Being vapor actuated, they are not subject toindicator error due to ambient temperature varia-

tions along the capillary tube system, and will giveexcellent readings provided the temperature beingmeasured is above or below ambient temperature.

Vapor instruments have progressive graduations,and are best read in the upper 2/3 of the dial range.Many ranges are available between –40°F and+450°F, and care should be exercised to select arange that will locate the operating temperatureswithin the upper 2/3 of the dial range (see ranges onback page).

Filled System ThermometersVapor Actuated

Window: Polycarbonate, or Glass.Bulb: Stainless Steel or copper. Bulb O.D. 7/16"(threaded), 3/8" (plain). Bulb lengths vary from 2 ½”to 9 ¼” depending on capillary length.Capillary: Copper, copper with bronze braid armor,stainless steel, stainless steel with stainless steelarmor. Capillary lengths 1 to 100 feet (standard length5 feet).Ranges: Over twenty °F and °F/°C ranges available,from –40° to + 450°F (see illustration, back page).Applications: Control panels, chemical processing,pipelines, food processing, OEM applications, ovens,solar heating, refrigeration, etc.

Specifications:Dial Sizes: 2", 2 ½”, 3 ½”, 4 ½”Dial: Aluminum with white finish and black markings, othercolors available.Pointer: Standard adjustable.Movement: Brass with precision gearing.Bourdon Tube: Phosphor bronze.Accuracy: Plus or minus one scale division.Case: All stainless steel, except: VA45FL (Aluminum)VA45TB (Phenolic).Process Connection: Plain Bulb, 1/2" NPTUnion, ½” NPT sliding union on 12" bendable extension, orThermowell. NOTE: Thermowells must be used wheneverthe bulb would be exposed to pressure, fluid velocity, orcorrosive media

R E G I S T E R E DR E G I S T E R E D

18

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Filled System ThermometersVapor Actuated - How to Order

Table 1 - Case StyleFront Flanged (Panel Mount)

U-Clamp (Panel Mount)

Rear Flanged (Panel Mount)

20FR25FR35FR45FR45FL

20UR25UR35UR

20RR35RR35RB45RR45RB45TB

35SB45SB35DA45DA

Code Dial Case Lens Connection Location3 1/2" SS Polycarbonate4 1/2" SS Polycarbonate

3 1/2" SS Polycarbonate4 1/2" SS Polycarbonate

Adjustable BracketMount

"Direct" adj. Mountw/3.4 Cu bulb, 1/2" NPT*

Code Dial Case Lens Connection Location2" SS Polycarbonate* Rear

2 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Rear4 1/2" SS Polycarbonate* Rear

4 1/2" Black Aluminum(hinge ring type) Glass Rear

Code Dial Case Lens Connection Location 2" SS Polycarbonate* Rear

2 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Rear

Code Dial Case Lens Connection Location2" SS Polycarbonate* Rear

3 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Bottom4 1/2" SS Polycarbonate* Rear4 1/2" SS Polycarbonate* Bottom4 1/2" Phenolic Glass** Bottom (Turrent Mount)

Model VVapor

Actuated

Case Style& Size

(Table 1)

TemperatureRange

(Table 2)

Capillary& Bulb

(Table 3)

CapillaryLength (in Ft.)

(Table 4)

ProcessConnection

(Table 5)

V 20FR 21 05 L2D

*Glass lens available, specify “Glass Lens”**Polycarbonate, lens available, specify “Poly Lens”

Other Case Styles

*Specify Model & Range Only.Example: V45DA-80

*

19

Filled SystemThermometersVapor Actuated - How to Order

Table 4 -- Capillary Length

Table 3 -- Capillary & Bulbs

Code Capillary &Bulb Material

CapillaryProtection

Copper NoneCopper Bronze Braid316 SS None316 SS S.S. Armor

Table 2 -- Temperature RangesCode °F Ranges Code

-40 TO 60°F -40 TO 60°F -40 TO 15°C -40 TO 110°F -40 TO 110°F -40 TO 40°C -20 TO 120°F -20 TO 120°F -30 TO 50°C 0 TO 180°F 0 TO 180°F -20 TO 80°C 0 TO 150°F 0 TO 150°F -15 TO 65°C 20 TO 220°F 20 TO 220°F 0 TO 105°C 40 TO 240°F 40 TO 240°F 0 TO 115°C 0 TO 250°F 0 TO 250°F -20 TO 120°C 30 TO 300°F 30 TO 300°F 0 TO 150°C100 TO 350°F 100 TO 350°F 40 TO 175°C200 TO 450°F 200 TO 450°F 100 TO 230°C

°F and °C Ranges

Table 5 --Process

Connection

ThermowellsFor VaporActuated

Bulbs(except M2)

CAPILLARY PLAIN BULB UNION CONNECTION THERMOWELL BENDABLE EXT.LENGTH L D U S D U S D L S D

1-10 ft. (bulb #1)21/2 (1-5ft.)

37/16 (6-10ft)

11-25 ft. (bulb #2) 37/163/8 21/2 31/4 7/16 25/8 33/8 9/16 37/16 4 - 14 3/8

26-50 ft. (bulb #3) 47/8 3/8 41/2 51/4 7/16 45/8 53/8 9/16 47/8 5 - 15 3/8

51-75 ft. (bulb #4) 77/8 3/8 61/2 71/4 7/16 65/8 73/8 9/16 77/8 8 - 18 3/8

76-100 ft. (bulb #5) 107/8 3/8 81/2 91/4 7/16 85/8 93/8 9/16 107/8 11- 21 3/8

3/8 113/16 23/8 7/16 115/16 21/2 9/163/8

21/2 (1-5ft.) 3 - 1337/16 (6-10ft) 4 - 14

20303272498050566068*70*

213133737981515761*66*71*

ACDE

J1J2J3K2L2M2

Code Connection Type MaterialNone (Plain Bulb)

Jam Nut Only Brass - (For Existing Brass Well)Jam Nut Only 316 SS - (For Existing Stainless Well)

1/2" NPT Union Brass 1/2" NPT Union 316 SS

1/2" NPT Sliding Union on Bendable Extension 316 SS - (Only Avail. with 316 SS Capillary)

Note: Capillary Lengths over 5 feet affect bulb length. See table at bottom of page.

12B

22B

32B

42B

52B

Union ConnectionPlain Bulb ThermowellBendable Extension

Bulb Configurations

Standard Bulb Dimensions (inches)

Specify Length in feet.Standard Length = 5 Ft.

Available Capillary Length: 1-100Ft.

&&&&&&&&&&&&

*Ranges over 300° come with316SS Capillary only.

1/2 NPT 3/4 NPT 1/2 NPT 3/4 NPTFor 1-10 ft. Capillary (bulb #1)

For 11-25 ft. Capillary (bulb #2)

For 26-50 ft. Capillary (bulb #3)

For 51-75 ft. Capillary (bulb #4)

For 76-100 ft. Capillary (bulb #5)

316 SSBrass

13B

23B

33B

43B

53B

12S

22S

32S

42S

52S

13S

23S

33S

43S

53S

L

DU

D

SU

D

SL D12"

S

R E G I S T E R E DR E G I S T E R E D

20

Filled System ThermometersVapor Actuated

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

No. 21

No. 61

No. 73

No. 31

No. 66

No. 79

No. 51

No. 81

Dial FacesTypical dial faces shown below; complete list shown on page 19.

Operating temperatures should be in upper 2/3 of selected range.

For Temperatures above or below those shown, ask for information on REOTEMP Gas Actuated Thermometers.

Front Flange U-Clamp Rear Flange

Case and Mounting Dimensions (inches)

Dial Sizes A B C D E F G H J2" 2.94 2.25 2.94 1.28R 2.05 0.98 1.28R 2.3 0.14

2 1/2" 3.69 2.81 1.66R 2.56 1 0.17

3 1/2" 4.75 3.97 4.75 2.16R 3.59 1.41RF.75UC, FF 2.16R 3.69 0.16

2.69R 4.69 0.224 1/2" 5.88FR6.31FL

5.88RR,RB5.83TB 2.69R

4.59FR47RR,RB, FL

1.41RF.75UC, FF

2.56TB1.63FL

CF C

FC

F

CF

CF

CF

CF

CF

21

Filled System ThermometersGas Actuated

REOTEMP Gas Actuated Thermometerscombine advanced gas coil technology with astate-of-the-art adsorbent (Class IV) thermalsystem, producing superior temperature mea-surement instrument that can be fitted to awide variety applications

Features include high accuracy, low ambienterror, no head error, and a high degree ofover-range protection. The compact (3/8” dia.x 3” active length) bulb, and a wide range ofcase styles and thermal systems, allow greatflexibility in installation.

The linear dial on all REOTEMP gas thermom-eters provides a consistent 1% accuracyacross the full span of each range. This,combined with over twenty Fahrenheit anddual ranges, from -320 F to +1200 F, providescomplete coverage of all normal temperaturerequirements.

SpecificationsAccuracy: +/- 1 % of full scale. Calibration to NISTtraceable standards.

Ranges: Twenty °F and °F & °C ranges available from-320°F to 1200°F.

Overrange: Minimum 50% of span above top of range,or 1300°F, whichever is less.

Ambient Error: 1/4% of span per 25°F change in am-bient temperature at midscale.

Dial Sizes: 41/2"& 6". Dials are white with black mark-ings.

Case Materials: Stainless steel, Phenolic,or Aluminum.

Case Styles: Panel Mount, Surface Mount, or Direct(stem) Mount.

Windows: Glass is standard. Shatterproof glassand acrylic are optional.

Pointers: Slotted adjustable type to permit zero-set adjustments.

Bulbs: 316 Stainless Steel, 3/8" dia. x 3" activelength. Other diameters and lengths are available.

Process Connections: Plain bulb; 1/2" NPTsliding union; 1/2" NPT fixed (on All-Angle); orthermowell. Note: Thermowells should be usedwhenever the bulb would be exposed to pressure,fluid velocity, or corrosive or abrasive media.

Thermal Systems: Stainless steel capillary withstainless steel spring armor (up to 40ft).Over 40 feet, stainless steel interlock armor is stan-dard. Direct mount stems, 316 SS, 4" to 48".

R E G I S T E R E DR E G I S T E R E D

22

Gas Actuated - How to Order

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Filled System Thermometers

Table 1Case Size

& Style

Table 2Thermal System

& Bulb

Table 4Temperature

Table 5Options

Table 3Capillary Length

(feet)

G 4 5 E R – 8 7 – L 1 5 – F B – X A W

Table 1-Case StyleWall Mount (“E” or “K” case)

Direct Mount (“D” case)

Panel Mount (“F”, “S” or “U” case)

“S” CaseS.S.,

Semi-FlushFront

Flange

“K” CaseS.S.,BackFlange

“D” CaseS.S.,All-AngleDirectMount

A

C

B

.75

A

C

B

D

3 HOLES G DIA. ONH BOLT CIRCLE

3 HOLESG DIA. ON

H BOLTCIRCLE

F

.44

3 HOLES GDIA. ONH BOLTCIRCLE

F

A B

D

180°ROTATION

BE

A

360°ROTATION

PANEL .5 MAX THK.88

DA

“U” CaseS.S.,

U-Clamp

“F” CaseAluminum

Front FlangeHinge Ring

B

F

E

D

C

A“E” CasePhenolicTurretMount

CASE CASECODE DIAMETER CONNECTION

G45ER 41/2" REARG45EL 41/2" LOWER

G45FR 41/2" REARG60FR 6" REAR

G45UR 41/2" REARG60UR 6" REAR

G45DA 41/2" ADJUSTG60DA 6" ADJUST

G45SR 41/2" REARG60SR 6" REAR

G45KR 41/2" REARG45KL 41/2" LOWERG60KR 6" REARG60KL 6" LOWER

41/2" “E” Turret Phenolic 5.83 2.56 5.08 2.62 1.0 .20 .24 5.3941/2" “F” Front Flange 6.31 1.63 - 4.88 - 1.35 .19 5.3841/2" “K” Back Flange 5.88 2.15 5.04 - - - 0.22 5.3841/2" “S” Semi-Flush 5.88 2.15 5.04 4.51 - 1.00 0.22 5.3841/2" “D” All Angle 5.04 2.00 - - 1.70 - - -41/2" “U” U-Clamp 5.04 - - 4.51 - - - -6" “F” Front Flange 7.87 1.59 - 6.34 - 1.75 0.19 6.696" “K” Back Flange 7.50 2.15 6.38 - - - 0.25 6.846" “S” Semi-Flush 7.50 2.15 6.38 5.88 - 1.00 0.25 6.846" “D” All Angle 6.38 2.15 - - 1.70 - - -6" “U” U-Clamp 6.38 - - 5.88 - - - -

Case Size Case Type A B C D E F G H

3 HOLES G DIA. ONH BOLT CIRCLE

G L X

Case Dimensions

23

Gas Actuated

CODE °F RANGES DIV.

Table 4-Temperature Ranges

FB -320/100°F 5°FE -120/120°F 2°FG -40/180°F 2°FH 0/120°F 1°FJ 60/120°F 1°FL 20/240°F 2°FN 0/300°F 5°FP 50/550°F 5°FR 50/750°F 5°FT 400/1200°F 10°

CODE °F & °C RANGES DIV.

DB -320/100°F / -200/40°C 5°/2°DE -120/120°F / -85/50°C 2°/1°DG -40/180°F / -40/80°C 2°/2°DH 0/120°F / -15/50°C 1°/1°DJ 60/120°F / 15/5°0C 1°/1/2°DL 20/240°F / -5/110°C 2°/1°DN 0/300°F / -10/150°C 5°/1°DP 50/550°F / 10/290°C 5°/5°DR 50/750°F / 0/400°C 5°/5°DT 400/1200°F / -200/650°C 10°/5°

Note: °C Ranges available on request

Specify Armored Capillary Length in Feet, up to 99 ft. (omit for “D” case).L05 = 5 feet L10 = 10 feet L15 = 15 feet…etc.Note: Stainless steel spring armor is standard protection on all capillary. Capillary over 40 feet requires XSI Spiral Interlock Armor option.

Table 3-Capillary Length

Filled System Thermometers

Table 2-Thermal Systems (all bulbs & capillaries are 316 SS)

All Angle Bulb

#11 bulb

#12 bulb

12"

.38 DIA. EXT/316, S.S.

BULB/316, S.S.

ARMOR

ARMOR 3"Active Length

.38 DIA.

.38 DIA.

.38 DIA.

REINFORCINGSPRING, S.S

Bendable Extension1/2" NPT

.38 DIA.

Stem Length

1/2" NPT

3"Active Length

3"Active Length

Extension Length

CODE DESCRIPTIONAll Angle Direct Mount with 1/2” NPT

(with “D” case only)4” stem x 3/8” diameter6” stem x 3/8” diameter9” stem x 3/8” diameter12” or longer stem x 3/8” dia. - specify stem lengthEXAMPLE: G45DA - 0X - 12” FB

0406090X

Plain Bulbs

Plain bulb, 3/8” x 3” active, + 12” rigidextension

Plain bulb, 3/8” x 3” active

11

12

Sliding 1/2” NPT onBendable Extension

3/8” x 3” active, 12” bendable extension

3/8” x 3” active, 18” bendable extension

3/8” x 3” active, over 18” bendable (Specify)

87

88

8X

3"Active Length

R E G I S T E R E DR E G I S T E R E D

24

XAW Acrylic Window (41/2" Cases only; not available in “F” Case).

XSG Safety Glass Window (41/2" Cases only; not available in “F” Case).

XMH Maximum or Minimum Hand.

XMM Maximum and Minimum Dual Hands.

XFR Flush Mounting Ring for “E” Case.

XBF 1/2" NPT Fitting for #11 Bulb - Fits on Bulb or extension.

XCF 1/2" NPT Fitting - Fastens on spiral interlock armor (requires XSI option).

XSI Spiral Interlock Armor (required over 40 feet).

XVD Vibration Dampening feature (dampens vibration - available in all rear connected models).

XTW Thermowell (see thermowell table below for order codes).

Code Description

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Gas Actuated

Table 5 - Accessories & Options

Thermowells for 3/8” dia. Elements

Filled System Thermometers

4 2 1/2 046 1466 4 1/2 047 147

3/4" NPT 9 7 1/2 048 14812 10 1/2 049 14915 13 1/2 050 15018 16 1/2 051 15124 22 1/2 052 152

4 2 1/2 053 1536 4 1/2 054 154

1" NPT 9 7 1/2 055 15512 10 1/2 056 15615 13 1/2 057 15718 16 1/2 058 15824 22 1/2 059 159

External Stem Insert OrderThread length Length Code

P A" U" 304 s.s. 316 s.s.

External Stem Insert Lag OrderThread length Length Ext. Code

P A" U" T" 304 s.s. 316 s.s.

Specify “TW” Plus Order CodeExample: TW-146

Lagging WellsStandard Wells

1/2" NPSM

STEM LENGTH A

3/4” NPT 6912151824

2 1/24 1/27 1/210 1/213 1/216 1/2

233333

247248249250251252

347348349350351352

1/2" NPSM

.385 DIA

STEM LENGTH A

How to Order

25

Filled Systems ThermometersDirect Drive Gas Actuated

Available in Four styles45GW WALL MOUNTED45GF FLUSH MOUNTED45GFF FRONT FLANGE45GAW ADJUSTABLE WALL

00 -200/100°C01 -100/100°C02 -30/60°C04 -10/80°C05 -30/120°C06 -10/150°C07 0/100°C08 0/200°C09 0/240°C10 0/300°C11 0/400°C12 100/400°C13 0/500°C14 0/600°C39 0/50°C

16 -350/150°F17 -100/100°F19 -40/120°F20 -40/200°F21 0/100°F23 0/150°F24 25/125°F25 0/200°F26 0/240°F27 0/300°F30 0/400°F31 0/500°F32 0/600°F33 150/750°F34 0/800°F36 0/1200°F38 20/240°F

Temperature Ranges

Celsius Ranges Fahrenheit Ranges

NITROGEN FILLEDDIRECT DRIVE SYSTEM

Specifications

Micrometer Adjustment Type

CASE:DIAL FACE:

LENS:POINTER:CAPILLARY:

ACTUATION:ACCURACY:

BULB:

Stainless Steel (SS)

+/- 1 % of Range Span

4 1/2" Satin Finish Aluminum, Black Lines andNumbers.Gasket Sealed Glass (Plexi Glass Optional)

Nitrogen thru SS Direct Drive Bourdon CoilSS Welded Construction

SS Protected by 1/4" Dia. Flexible SS Armor or3/16" Dia. Plain Armor

REOTEMP’s Rugged Direct Drive System makes our 45G seriesgas – actuated series the right choice for temperature indication inheavy duty or high vibration applications.

Its all-stainless steel case and internals, alongwith the direct drive system, result in superiorinstrument life in severe environments.

R E G I S T E R E DR E G I S T E R E D

26

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Filled Systems ThermometersDirect Drive Gas Filled Remote

Case Specifications

45GW =

45GF =

45GFF =

45GAW =

05 =

06 =

10 =

Other =

G112 =

G118 =

G212 =

G224 =

EC =

MP =

SG =

PC =

3/8” dia. bulb with 3/8” extension up to 48” withoptional 1/2” NPT compression fitting; All SS

3/8” dia. bulb with 3/16” bendable complete with 1/2” NPTcompression fitting; All SS

G2G1

Model 45GW

Model 45GF

Model 45GAWWall Mounted

Complete with Bracket

Flush Mounted Completewith U - Bracket

Adjustable Wall MountedComplete with Flange

45GW 06 08 G118 45SG

Model 45GFF

Bulbs

12”

Temperature Range

Wall Mount 5 Feet 12" Bendable Extension with 1/2" NPT Union Electrical Contacts

Flush Mount 6 Feet 18" Bendable Extention with 1/2" NPT Union Max Hand Pointer

Front Flange 10 Feet 12" Plain Bulb with Rigid Extension Tempered Glass

Adjustable Wall Mount

Specify Lengthin Feet

24" Bendable Extension with 1/2" NPT Union

Polycarbonate Crystal

Armored Capillary Length

See chart on Page 25.

Accessoriesfor Thermowells see pg. 24

Bulb TypeModel

Flush Mounted Completewith U - Bracket

How to Order

27

Filled Systems ThermometersDirect Drive Gas & Liquid Filled

Specifications:

Micrometer Adjustment Type

CASE:DIAL FACE:LENS:POINTER:

ACTUATION:

ACCURACY:

BULB:

Stainless Steel (SS)

+/- 1 % of Range Span

4 1/2" Satin Finish Aluminum, Black Lines and NumbersGasket Sealed Glass (Polycarbonate Optional)

45 LR - Inert Liquid thru SS Direct Drive Bourdon Coil (For*ranges, Nitrogen thru SS), Direct Drive Bourdon Coil.45GR - Nitrogen thru SS Direct Drive Bourdon Coil.

SS Welded Construction

45GR 06 08 ST6 316

45GR =

45LR =

02 =04 =06 =09 =12 =15 =

ST4316ST6316ST9316

EC =MP =

MODEL45GR

MODEL45LR

EVERY ANGLE

REOTEMP’s Rugged Direct Drive Systemmakes our 45GR and 45LR the right choice fortemperature indication in heavy duty or highvibration applications. Its all-stainless steelcase and internals, along with the direct drivesystem, result in superior instrument life insevere environments.

How to Order

Temperature Range

2 1/2" (LR Only)

4" "U" 3/8" 6" Dim. element9" 2.5"12" 4.5"15" 7.5"

p. 24 )

Tempered GlassPlastic Crystal

(More wells on:

Elec. ConnectionMax Pointer

p. 14

Accessories

4"6"9"

StemLength

Standard Thermowells (3/4"NPT, 316SS)1/4"

element

Gas Actuated3/8" Stem

Model

See chart on Page 25.

Armored Capillary Length

Inert LiquidActuated, 1/4" Stem

GXTW146GXTW147GXTW148

SG =PC =

R E G I S T E R E DR E G I S T E R E D

28

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Digital ThermometersHand-Held Thermometers

Model TM99A(with disposable battery)Model TC100A(with rechargeable battery)

Features• All Solid State• High Stability• Cold Junction Compensation• Wide Temperature Ranges

Features• All Solid State• High Accuracy• Detachable Probes• Wide Temperature Ranges

Probes for Models: HI 9063 and 701KFThermocouple Probes (intermediate sizes, orindustrial configurations avalaible on application)Probes have 4” handle and min. 36” lead, exceptwhere noted.

10K Thermistor ProbesAll but 2010 and 7041 have 3”handle and 48” coiled lead.

Probes for Models:TM99A and TC100A

Durable, shockresistant ABSplastic carryingcase

Model HI 9063Water Resistant Min - Max, °F/°C

Model 701K - Pocket SizeMagnet on back - stick it anywhereIn Stock in °F; Also available °C.Sealed

membranetouch pad

Easy-to-read,backlighted

LCD displaysboth °F

and °C

Model Description Probe Dimensions

S/S Immersion(comes standard) .142" x 4"

S/S PiercingTip Probe .041" x 2.8"

Fast Surface ProbeAir Probe .125" x 4"General Purpose Probe .18" x .6"

Model Description Probe Dimensions

Immersion/General Purpose .156" x 5"

Fast Response (no handle) 1/16" x 12"

Fast Response 1/16" x 4"Piercing Tip .156" x 4"Soft-wire Disposable (no handle) exposed tip 48"

Surface Temperature

Gas TemperatureHeavy Duty General Purpose 1/4" x 12"

Heavy Duty Penetration (pointed) .40" x 36", 48" or 60"

1075

1052

4040

50052010

LPK5

XPK2

FRK4HPK2REK1

LPK12LPKA

SPK1

MRK36,48,60

Specifications: TM99ATC100A HI 9063 701KF

Range & Resolution

-40F TO +300F(-40C TO +150C)0.1F or C Resolution

C/LO Mode: -50 TO 150C with 0.1C ResolutionC/HI Mode: -50 TO 950C with 1C ResolutionF/LO Mode: -58 TO 302F with 0.1F ResolutionF/HI Mode: -58 TO 1742F with 1F Resolution

-50 To 1,000F with 1F Resolution

Accuracy Greater of ±0.3F, or ±0.5% of reading ±0.3% Full Scale / ±3C (hi), ±0.6C (lo) ±.25%* (±1 Digit)Ambient Range 0 To 150F max, RH -90%, noncondensing -10 TO 50C (14 To 122F) RH 100% 32 TO 104FDisplay Backlighted .4" LCDProbe #1075 10K Thermistor, detachable Type K Thermocouple Type K Thermocouple (Optional)

Power TM99A - 9V alkaline battery (provided)TC100A - 9V NiCad battery with 110V charger 4 - 1.5V AAA batteries 1 - 9V battery

Size 9 1/2" x 6 1/2" x 2 1/2" (case closed) 7.7" x 3.1" x 2.4" (196 x 80 x 60mm) 3.1" x 2.4" x 1.1" (80 x 60 x 33.5mm)

TM99ATC100A

1. Specify Model #.2. Specify Probe. 701K SPK1

Model # Probe

Hand-HeldThermometer Models

701KHI9063

Disposable Battery

Rechargable Battery

Compact

Full Functioned

"K" ThermocoupleModels

ThermistorModels

How to Order

29

Thermocouples & RTD’s

TABLE D Resistance Temperatures Detectors

How to Order: Construct part number from table D below.

For Thermowell Assembly: Insert part number obtained below into assembly part number on page 31.

Insert single-digit number designated below. 1 (standard) -200 / +400°F (-130 TO +200°C) 2 (hi temp) -200 / +1100°F (-130 To +600°C)

Insert two-digit number designated be designated below. 18 = .188 dia. 25 = .250 dia. 37 = .375 dia.

Insert single-digit number designated below. 1 = 316 SS 3 = 304 SS 5 = INC 600

Insert single-digit number designated below.(STD) Platinum - 1 = 100 Ohms 2 = 200 Ohms 5 = 500 Ohms Nickel - 7 = 120 Ohms Copper - 8 = 10 Ohms

Specify lead length “B” in inches.(Omit for T/W assemblies, or where N/A)Need something you don’t see?

Call REOTEMP for information.•1-800-648-7737•

Choose from “Styles” table. Insert letter below. (for thermowell assemblies, specify style “A”)

STEP 3 - Temperature

STEP 4 - Sheath Diameter

STEP 5 - Sheath Material

STEP 6 - Resistance 32°F (0°C) Ohms ±.5% (#1 IS STANDARD)

STEP 7 - Determine the required length “L” in inches

STEP 9 - Lead Length

STEP 2 - Sensor Material (Px is standard)

STEP 1 - RTD Style

Insert letter designated below. Px - Platinum 0.00385 Ω/Ω/°C P - Platinum 0.00392 Ω/Ω/°C Pl - Platinum 0.00390 Ω/Ω/°C

N - Nickel 0.06725 Ω/Ω/°CC - Copper 000421 Ω/Ω/°CBa - Balco

For Thermowell assemblies, specify “AR” (as required)

Special Ranges available onapplication

RTD’s (Resistance Temperature Detectors)

RTD Styles

A

B

C

D

E

H

1/2 NPT Std.

B

B

Welded

Spring Loaded 1/2 NPT Std.

B

A standard RTD Assembly may be supplied withan adjustable compression fitting. Specify.

A standard 1/2 x 1/2 NPT stainless bushing is welded tothe element sheath. 1/4 x 1/4 and 3/4 x 3/4 are available.Specify.

A quick-disconnect male plug is mounted on the coldend of the element. Two or three prong standard plugsare available. Two prong miniature plugs areavailable. Specify.

A quick-disconnect female jack is mounted on thecold end of the element. Two or three prong standardjacks are available. Two prong miniature jacks areavailable. Specify.

This RTD is terminated with an “O” ring seal.Canister Head.

A standard 1/2 x 1/2 NPT stainless hex bushing allowsthe element to be spring-loaded up to 1/2.

STEP 8 - Number of Leads/RTD’sSingle RTD Leads/RTD Duplex RTD W 2-wire WW X 3-wire XX Y 4-wire YY

How to Order

R E G I S T E R E DR E G I S T E R E D

30

Mineral Insulated Thermocouples

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Thermocouples & RTD’s

Need something you don’t see?Call REOTEMP for information.

•1-800-648-7737•

Insert 2 digit number designated below.12 = .125in. 18 = .188in 25 = .250 in. 37 = .375in.

Insert single-digit number designated below. 1 = 316 SS 1700°F (927°C) 3 = 304 SS 1650°F (899°C) 2 = 310 SS 2100°F (1149°C) 5 = Inconel 600 2100°F (1149°C)

S = Single element assemblyD = Dual element assembly

Elements: G = Grounded U = Ungrounded

Length “L” in inches. For complete assembly withthermowell specify “AR” (as required).

“B” in inches (omit for thermowellassemblies, or where n/a)

TABLE C Thermocouples

Metal Sheathed Thermocouple Assembly - Insert “M”STEP 1

STEP 2 - Sheath Diameter

STEP 3 - ANSI Type Thermocouple Element

STEP 4 - Type of Sheath Material

Choose style from “Styles Table”. Insert letter(s) below. (For thermowellassemblies specify “A”)

STEP 6 - Number of Element

STEP 7 - Type of Junction

STEP 8 - Probe Length

STEP 9 - Specify Lead Length

M

Spring Loaded 1/2 NPT Std.

B

D

H

Thermocouple Styles

How To Order:Construct part number

from table “C”.

For Thermowell Assembly:

Insert part numberobtained below into

assembly part numberon page 31.

Thermocouple Styles

A

B

C

1/2 NPT Std.

B

B

Welded

Insert designation below.K = Chromel Alumel T = Copper ConstantanJ = Iron Constantan E = Chromel Constantan

Plain sheath with wire leads. Cold end epoxy sealed.Choose this style for Thermowell assemblies.

A standard 1/2 x 1/2 NPT stainless bushing is welded tothe element sheath.

Male Mini-plug is mounted to cold end of sheath. Standardsize plug available (specify).

A standard 1/2 x 1/2 NPT stainless bushing allows theelement to be Spring Loaded up to 1/2".

STEP 5 - Style

Female Mini-plug is mounted to cold end of sheath.Standard size plug available (specify).

How to Order

31

1 5/8"*L

Thermowell AssembliesThermocouples & RTD’s

ScrewCover Head

Table ABelow

ThreadedConnection

Table BBelow

ThermowellTable E (p.32) optional

2-1/2"* L

3"*L

5"*L

1L 1T

2L 2T

3L 3T

4T

Also Available:• Thermocouple Wire• Transmitters• Multipoint Thermocouple Assemblies• Protection Tubes• Stainless Steel Fittings

Example:

TABLE B Threaded Connection Configuration

CONFIGURATION: Dimen-sions are approximate.(with thermowell, sheathlength “L” does not have tobe specified)

StandardSteel

Fittings

Probe ElementThermocouples - Table C (pg.30)

or RTD’s - Table D (pg.29)

B – 1 L – M 25 K 3 A S G AR – S T 4 3 0 4

Head-Bushing

(Nom.)21/2"

Head-Nipple

Head-Nipple-Union

Head-Nipple-Union-Nipple

3" (Nom.)

UNIVERSAL CAST IRON TYPE A

UNIVERSAL CAST ALUMINUM TYPE B

FDA WHITE POLY TYPE S

EXPLOSION PROOF TYPE E

• Universal head• Cast iron• Heavy Duty• 1/2 NPT process with 3/4 NPT

conduit is standard

• Universal head• Cast aluminum• 1/2 NPT process with 3/4 NPT

conduit is standard

• Screw cover Poly head• Impervious to most

corrosive media• 1/2 NPT process with 3/4 NPT

conduit• SS Chain & Screws

• Explosion Proof• Cast aluminum

body & cap• For use with two wire transmitter• Rated for Class I, Groups C, D,

Class II, Groups E, F, G, Class III• 1/2 NPT process with 1/2 NPT

conduit is standard

TABLE A Screw Cover Heads

5”(Nom.)

(Nominal)1 5/8"

Transmitters - Specify 4-20mA transmitter by adding “X” to head type.Example: Type B head with Transmitter = BX (specify Temp. Range)Terminal Blocks - Standard in all heads.

4L

316 SSFittings

Stems are spring loaded*for positive contact withbottom of thermowell.

* For welded SS fittings, substitute”F” for “T” Example: 1F

R E G I S T E R E DR E G I S T E R E D

How to Order

32

Finished Assemblies - Ready to Go

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com

Thermocouples, RTD’s & Accessories

• Type K or J Thermocouple (single element, ungrounded)• Weatherproof Cast Aluminum Screw Cover Head, with Terminal Block• 316 SS Bushing, or steel Nipple• 1/4" dia. 316 SS Spring-loaded Stems, 4"’ 6"’ 9"’ or 12 “• Available for fast delivery

B1TM25K1ASU4B1TM25K1ASU6B1TM25K1ASU9B1TM25K1ASU12

B1TM25J1ASU4B1TM25J1ASU6B1TM25J1ASU9

B1TM25J1ASU12

B1TAPX125114XB1TAPX125116XB1TAPX125119XB1TAPX1251112X

Thermocouples

RTD’s (3-wire, 100 ohm)

Table E

Stem (L) Model #4"6"9"12"

Stem (L) Type K Type J4"6"9"12"

Popular Thermocouple & RTD Assemblies

B2LM25K1ASU4B2LM25K1ASU6B2LM25K1ASU9B2LM25K1ASU12

B2LM25J1ASU4B2LM25J1ASU6B2LM25J1ASU9

B2LM25J1ASU12

B2TAPX125114XB2TAPX125116XB2TAPX125119XB2TAPX1251112X

Thermocouples

RTD’s (3-wire, 100 ohm)Stem (L) Model #

4"6"9"12"

Stem (L) Type K Type J4"6"9"12"

TCX 001 T2TCX 001 T3TCX 001 T4

Other Accessories:

1 5/8"*L 5"*

L

Model # Description Model # DescriptionCast Iron Head Terminal Block, 2-wireCast Aluminum Head Terminal Block, 3-wireSpring loaded Bushing Terminal Block, 4-wire2 Wire Temperature Transmitter, 4-20 mA (specify calibration)

Head-Bushing Assemblies Head-Nipple-Union-Nipple Assemblies

Thermowells - Common Threaded Thermowells (3/4"NPT external thread).

For other similar wells, see complete listing, p. 14.

Field- Cuttable Thermocouples & RTD’s• Adjustable probe length, 2.5" to 18"• Probe is cut with simple tube cutter• One size fits many - simplify inventory.

TCX 006 ATCX 006 B

TCX BSL 22TCXT4

Thermocouples, Specify:1. Model (TC-1350 or RTD-1340)2. Sensor type (K, J, T, E, Etc.)3. G (grounded) or U(ungrounded)Example: TC-1350-K-G

For other similar wells, see complete listing, p. 24.

ST4304ST6304ST9304

GTXW046GTXW047GTXW048

GTXW146GTXW147GTXW148

ST4316ST6316ST9316

304 SS 316 SS4" 2 1/2"6" 4 1/2"9" 7 1/2"

StemLength

1/4" DIA. ELEMENTS"U"Dim 304 SS 316 SS

4" 2 1/2"6" 4 1/2"9" 7 1/2"

StemLength

3/8" DIA. ELEMENTS"U"Dim

R E G I S T E R E DR E G I S T E R E D

How to Order

How to OrderRTD’s, specify Model only.Example: RTD-1340

33

CIP Sanitary RTD’sThermocouples & RTD’s

ROETEMP’s Santary RTD’s are de-signed for temperature sensing in food,dairy, beverage and pharmaceuticalapplications where sensor corrosionand product contamination are critical factors.

Features:

Ideal for CIP (Clean-in-Place) All Sensors Highly Polished to Exceed 3A Requirements Quick-Connect Tri-Clamp Design Fast Response Tip Available Variety of Stem and Termination Options

Stem Options Termination Options

Standard Stem Type A

3”Immersion

X1/2”

1/4” OD, 316L SS

Sensitive Portion

S/S Sanitary Cap

3”Immersion

X1 1/4”

316L SS

S/S Sanitary Cap

Reduced Tip Stem Type B, C, E

4 1/2”

5/32” OD

X3/4”Tri-Clamp

Type D Mini-Stem with T-75 Mini-Cap

Connection Head Types S, Y (or Type T w/transmitter)FDA Compliant

White Polypropy-lene Screw CoverHead (Standard)

Type L (with Teflon Leads)

Type N (with Teflon Leads)

2 1/4”

1/2” NPT

ELead Length(STD. = 6”)

2 1/4”E

Lead Length(STD. = 6”)

All Stems are Polished 316L SS Other Options Available

See Easy “How to Order” guide on page 34.

34

CIP Sanitary RTD’s

REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com

Thermocouples & RTD’s

• Alternate Wire Termination• Alternate Sanitary Cap Styles• Digital Indicating Meters (Suitable for Washdown)• Thermocouple Sensors (Sanitary & Industrial)

• RTD’s with CIP Sanitary Connected Wells• Penetration Probes• Chemical Resistant Thermocouples• Stainless Steel Tags

Other Available Options:

Other REOTEMP CIP Sanitary Products

L3 030 A T15 L 12

Description1.5" (Standard)2"3"3/4" Fractional (with "D" stem only)

Other Cap Styles Available - Please Specify

Description

Std. White Polypropylene Connection Head (FDA Compliant)

White Polypropylene Connection Head with 4-20ma Transmitter

White Epoxy Coated Aluminum Head

1/2" OD 316SS transition with (E") Teflon Leads (Specify Length, e.g. 12" = )1/2" NPT 316SS Threaded Fitting with Teflon Lead (Specify Length, e.g. 6" = )

T15 =T20 =T30 =T75 =

S =

T =

Y =

L =

N =

R

Table 1 - RTD Type

Accuracy # Elements0.10% 10.01% 10.10% 20.01% 2

100 ohm; .00385µ; 3 wire

Maximum temperature: 400°F (204°C)

L3 =H3 =L6 =H6 =

Table 2 - Immersion Length (X)Length Length

2" 6"3" 9"4" 12"

Long or intermediate lengths OKPlease specify length

020 =030 =040 =

060 =090 =120 =

Description1/4" Diameter

Reduced Tip (3/16" tip OD X 3/8" sheath OD)

Reduced Tip (1/4" tip OD X 1/2" sheath OD)

5/32" Diameter Tip (with T75 mini-cap only) Single Element Only

Special HTST Fast Response Reduced Tip (3/16 tip OD X 3/8" sheath OD, response time 3 to 3.5 sec.) Available in H3 & H6 RTD Type Only.

A =

B =

C =

D =

E =

Table 3 - Stem Style (All stems hightly polished to exceed 3-A#09-08).See stem options table pg. 33

Table 4 - Sanitary CapTri-Clamp Caps (Triclover 16 AMP Type)

Table 5 - Termination(See Termination Options pg. 33)

L12

N6

Sanitary PressureGauges

Sanitary Thermowells Sanitary PressureTransmitters

Sanitary BimetalThermometers

α

How to Order

35

Bimetal ThermometersSurface Thermometers

Bimetal ThermometersPocket Thermometers

Model # Temperature Ranges

K-79-2 -40 to 160°FK-79-3 0 to 220°FK-79-4 25 to 125°FK-79-5 50 to 550°F

K-79-7 -10 to 110°CK-79-8 0 to 150°CK-79-9 0 to 250°C

D-450 -40 to 450°FD-302 -58 to 302°F

Specifications

Accuracy - 1% of ScaleHead - 1” Diameter (25mm)Dial - White Background with crispletters, marks, and numbers.Stem - .142 OD, 5” long, pointed(3.6mm x 127mm)Reset Nut - 7/16” Hex (11mm)Pocket Case - Stainless Steel orPlastic with Clip and Holder LoopWeight - .65 ounces (18.5G)Packed - 1 per box, 12 per carton

Digital Pocket Thermometer

Model D-450

Resolution 0.1°F Stainless Steel Stem, .14 x 5” Accuracy 1% of span Comes with Pocket Case 1/4” High LCD Display

Also Available: D-302, -58 to 320°F

Analog (Dial) Models

Model K-79

Accurate & Rugged Quick Response Shock Resistant Sensitive Bimetal Element External Reset Adjustment Waterproof and Dustproof Stainless Steel or Plastic Pocket Case

Front View

Back View

Magnets

BimetalSensingElement

ProtecitiveCover andHeat Collector

How to Order

Digital Specifications

D-450 D-302

Range -40/450° F -58/302° FResolution 0.1° F 0.1° FAccuracy ± 0.8% of span ± 1% spanDisplay ¼” LCD ¼” LCDOFF Function 50 Min. Auto ManualUpdate 10 Seconds 4 Seconds

Specifications

Accuracy - Within 2% of full scaleHead - 2” (5.08cm)Dial - White Background, blue marks &numbersHeight - 1/2” (1.27cm)Weight - 2 ounces (56.7G) approx.Case - aluminum with optically clearcrystalSensing Element - precision calibratedbimetal coilResponse Time - approximately 1 minuteMounting - two Alnico magnets on back

Model # Temperature Ranges

SUR-15 0 to 150°F/-20 to 65°CSUR-50 0 to 500°F/-20 to 260°CSUR-25 0 to 250°F/-20 to 120°CSUR-75 50 to 750°F/10 to 400°C

Measures Temperature of any Horizontal Surface Magnetic Feet hold to any Ferrous Surface Used on Griddles, Ovens, Motors, Piping, Tanks, etc..

How to Order

How to

Analog

Digital

R E G I S T E R E DR E G I S T E R E D