renal 11th annual vascular noninvasive testing symposium ... · 11/27/2018 10 patent bilateral...

34
11/27/2018 1 11 TH ANNUAL VASCULAR NONINVASIVE TESTING SYMPOSIUM NOVEMBER 10, 2018 RENAL ARTERY DISEASE AND RENOVASCULAR HYPERTENSION

Upload: others

Post on 26-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

1

11TH ANNUAL VASCULAR NONINVASIVE TESTING

SYMPOSIUMNOVEMBER 10, 2018

RENAL ARTERY DISEASE AND RENOVASCULAR HYPERTENSION

Page 2: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

2

WHAT IS RENOVASCULAR HYPERTENSION?

https://my.clevelandclinic.org/health/diseases/16459-renovascular-hypertension

RENAL ARTERY STENOSIS ~ RENOVASCULAR HTN

https://my.clevelandclinic.org/health/diseases/16459-renovascular-hypertension

Page 3: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

3

ATHEROSCLEROSIS, OR HARDENING OF THE ARTERIES, IS THE MOST

COMMON CAUSE OF RENAL ARTERY STENOSIS

CRITERIA FOR DIAGNOSIS OF RENAL ARTERY STENOSIS

BROAD CATEGORIES BASED UPON RENAL AND AORTA PSV:

0-59% STENOSIS: RENAL PSV < 200 CM/SECRENAL-AORTIC RATIO (RAR) < 3.5

60-99% STENOSIS: RENAL PSV > 200 CM/SECRAR > 3.5> 80% STENOSIS IF EDV >150 CM/SEC

OCCLUDED ABSENT FLOW

SENSITIVITY 84-98%; SPECIFICITY 62-99% VARIABLE BYPUBLISHED SERIES

Slide provided by Heather Gornik MD

Page 4: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

4

PERFORMANCE OFRENAL DUPLEX ULTRASOUND FOR DIAGNOSIS

OF RAS

•Olin JW, et al. Ann Intern Med 1995;122:833

Slide provided by Heather Gornik MD

RESISTIVE INDEX (RI)

RI = PSV-EDV/PSV=19-5.3/19=0.72

Slide provided by Heather Gornik MD

Page 5: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

5

NORMAL VS. HIGH RESISTIVE RENAL DOPPLER SIGNALS

RI=0.54RI=0.82

Normal Signal High Resistive Signal

Unhealthy kidney!

Slide provided by Heather Gornik MD

ONE MORE PARAMETER: ACCELERATION TIME

•Slide provided by Heather Gornik MD

Page 6: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

6

DUPLEX EVALUATION FORRENAL ARTERY STENOSIS

•Slide provided by Heather Gornik, MD

USE CAUTION WITH RAR WHEN AORTIC VELOCITY IS NOT NORMAL

Page 7: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

7

RENAL ARTERY STENOSIS

•Slide provided by Esther Soo Hyun Kim MD

Page 8: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

8

LRA STENT

Instent stenosis > 80% EDV > 150

RAR 6.2

Normal Renal Aortic Ratio is < 3.5

Page 9: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

9

Page 10: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

10

Patent Bilateral Stent

INTERPRETATION FOR STENTED RENAL ARTERY

OUR LAB CURRENTLY FOLLOWS THE CRITERIA DISCUSSED EARLIER WHENEVALUATING STENTING IN AN ISOLATED RENAL ARTERY.

PSV < 200 CM/SEC (RAR) < 3.5 0-59% STENOSIS

PSV >200 CM/SEC (RAR) > 3.5 60-99% STENOSIS

> 80% STENOSIS IF EDV >150 CM/SEC

STENTS, VELOCITIES MAY BE ELEVATED WITHIN A WIDELY PATENT STENT. IF NOPOST-STENOTIC TURBULENCE IS NOTED. REPORT: PATENT. ELEVATED VELOCITIES NOTED WITHIN THE STENT, BUT NOTURBULENCE SEEN.

Page 11: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

11

RENAL DISEASE IN THE VASCULAR LAB

FIBROMUSCULAR DYSPLASIA “FMD”

WHAT IS FMD? PATHOLOGICALCLASSIFICATIONS

Page 12: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

12

CRITERIA FOR DIAGNOSIS OF RENAL ARTERY FMD

TURBULENT FLOW AND ELEVATED VELOCITIES AT

MID OR DISTAL VESSEL ARE EVIDENCE OF

FIBROMUSCULAR DYSPLASIA

BeadingString of beads appearance

Page 13: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

13

ANGIOGRAPHY

Slide provided by www.emorypulse.com

Page 14: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

14

WHO IS OUR FMD PATIENT?

••

•Slide provided by Heather Gornik MD

SAME DAY ADD-ON

Page 15: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

15

INITIAL SCAN

INTERPRETATION

Page 16: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

16

VASCULAR SURGERY CONSULT

Decubitus LRA

Repeat study Fasting

Page 17: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

17

TWO RRAS??

Decubitus Position

CT W/CONTRAST

Page 18: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

18

DUS & CT RESULTS

CO2 ANGIOGRAPHY LRA PTA

Page 19: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

19

RRA BALLOON X2MID NARROWING /

POST DILATATIONPATENT POST BALLOONING

TWO MONTH POST PTA LRA

Page 20: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

20

2 MONTH POST PTA RRA

No change in right renal artery: 60-99% stenosis; EDV may suggest greater than 80% stenosis.Left renal artery: is now 0-59% stenosis.Patient to return for six month follow up DUS

RRA >80% stenosis

Abnormal RI

4 months later ~ 6 mo f/uNO REAL CHANGERight renal artery: 60-99% stenosis; EDV may suggest greater than 80% stenosis.Vessel bifurcates at mid.Recommended repeat PTA of the RRA

Page 21: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

21

CO2 ANGIOGRAPHY W/PTABASED ON VAS LAB FINDINGS

RIGHT RENAL ARTERY

STENOSIS OF ABOUT 80%

WITH A GOOD

RESOLUTION FOLLOWING

SERIAL BALLOON

ANGIOPLASTIES

ONE MONTH S/P 2ND RRA PTA

Page 22: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

22

SUCCESS !!!!

RENAL ARTERY ANEURYSM “RAA”

• Rare

• Asymptomatic

• Usually found incidentally on other imaging

• Common in women age 40-60

• Can be associated with atherosclerosis, hypertension, and Fibromuscular Dysplasia (FMD)

• Rupture can be fatal

• Can experience abdominal pain

• 98% occur outside of the kidney

http://health.clevelandclinic.org/2012/12/renal-aneurysm

Page 23: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

23

Page 24: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

24

TREATMENT

••

STENTING & COIL EMBOLIZATION

Page 25: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

25

ARTERIOVENOUS FISTULA VS ARTERIOVENOUS MALFORMATION OF THE KIDNEY

WHO IS OUR PATIENT

Page 26: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

26

NORMAL AORTIC VELOCITY

COLOR DOPPLER ALIASING

Page 27: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

27

POWER ANGIO BEADING???

DILATED LRV W/ TURBULENCE

Page 28: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

28

Fistula Signal

VAS LAB INTERPRETATION

Page 29: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

29

CT SCAN

RECONSTRUCTED CTA

AP VIEW PA VIEW

Page 30: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

30

CT RESULTS OFLEFT KIDNEY

TREATMENT

Page 31: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

31

CO2 ANGIOGRAPHY W/ COIL EMBOLIZATION

Successful Post coil embolization

Page 32: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

32

RENAL AVM AND AVF

BOTTOM LINE

Page 33: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

33

DUPLEX ULTRASOUND

REFERENCES

1.

2.

3.

4.

5.

6.

7.

8.

Page 34: Renal 11th Annual vascular Noninvasive Testing Symposium ... · 11/27/2018 10 patent bilateral stent interpretation for stented renal artery our lab currently follows the criteria

11/27/2018

34

1931

THANK YOU

JEAN STARR MD, RPVIDENNIS KISER BS, RVT

HEATHER GORNIK MD, RPVI