releasenote sdd converter 8 28march2009

51
1 Upgrade procedure for SDD Converter From MiniSDD Ver1.2(3) and Ver2.1 into SDD-J AP100 CAD- Sheet Works -MiniSDD Data(IGA and BMF) BENDCAM MiniSDD Data(BMF and SQ-BMF) AMNC Ver3.XX Direct/Angle/2D mode MiniSDD data ASTROCAM MiniSDD Data support in NEXT Version.( Now Non-supported ). Release Notes (for EU and US - CANADA) Application name : SDD-J BEND Program Converter Release version : MiniSDD to SDD-J BEND Converter Build Ver Mar05-2009.exe (Install Shield Name) Release date : March/2009 -Release Note modification (New support 18 Page 28 )

Upload: michelle-brown

Post on 10-Nov-2014

101 views

Category:

Documents


3 download

DESCRIPTION

http://metalforming.vn

TRANSCRIPT

Page 1: ReleaseNote SDD Converter 8 28March2009

1

Upgrade procedure for SDD Converter

From MiniSDD Ver1.2(3) and Ver2.1 into SDD-J

AP100 CAD- Sheet Works -MiniSDD Data(IGA and BMF)

BENDCAM MiniSDD Data(BMF and SQ-BMF)

AMNC Ver3.XX Direct/Angle/2D mode MiniSDD data

ASTROCAM MiniSDD Data support in NEXT Version.(Now Non-supported).

Release Notes

(for EU and US - CANADA)Application name : SDD-J BEND Program Converter

Release version :MiniSDD to SDD-J BEND Converter Build Ver Mar05-2009.exe(Install Shield Name)

Release date : March/2009 -Release Note modification (New support 18 Page 28)

Page 2: ReleaseNote SDD Converter 8 28March2009

2

Official Version

Page 3: ReleaseNote SDD Converter 8 28March2009

3

INDEX

>>>First of all

>>>Release Note (Supporting items.)

>>>Procedure of SDD-J Converter steps

>>>Trouble Shooting

Page 4: ReleaseNote SDD Converter 8 28March2009

4

First of all

Page 5: ReleaseNote SDD Converter 8 28March2009

5

First of all

I recommend to convert in respective OS(French-German-Italian-Spanish ) for EU to avoid “SQL convert error”.

Because native character (French-German…) support in respective OS(French-German-Italian-Spanish ) for EU .

(For example MiniSDD comments file-Folder name…)

If you convert in English OS , it does not support EU native character (French-German…) .

Please check now in your target PC as EU Language support.

Page 6: ReleaseNote SDD Converter 8 28March2009

6

First of all

Need software environment

SDD-J BEND Program Converter need MiniSDD (Ver1.23 or Ver2.1 ) and SDD-D mixed environment in One PC.

Please check now your PC environments before execute it.

In Your PC (One PC)

Install MiniSDD Install AP100 SDD-J

Convert

Need software environment

Please check now in your target PC software environment!

Page 7: ReleaseNote SDD Converter 8 28March2009

7

Recommend Hard ware Spec for Converting

It need enough memory inside logic.CPU : Pentium 4 Over 3.8G Hz

Memory : Over 2 GB

HDD : 120 GB

Graphic processor : Quadro FX 540 IRQ 16 – Over 128 MB memory

Direct X 9.0 support

If your PC is NOT Enough inside Memory , sometimes you will have application error during converting…….Take care!

First of all

Page 8: ReleaseNote SDD Converter 8 28March2009

8

Release Note

(Supporting items.)

Page 9: ReleaseNote SDD Converter 8 28March2009

9

<This version support (Version 2006/Jun/01)> New Support (1) MiniSDD Ver 1.2(3) and MiniSDD Ver2.1 Both

Page 10: ReleaseNote SDD Converter 8 28March2009

10

New Support (2) Add all AMNC standalone data support into SDD-J

Page 11: ReleaseNote SDD Converter 8 28March2009

11

New Support (3) Display warning message in case of existing MiniSDD SUB-FOLDER.

(Because SDD-J do NOT support SUB-FOLDER structure ).(Ex.)

Please modify(move) SUB-FOLDER as next PAGE “< STEP Procedure>”. See New Support (7)

page!Already supported.

Page 12: ReleaseNote SDD Converter 8 28March2009

12

New Support (4) Support Metric and Inch data in MiniSDD.

MiniSDDVer1.23

MiniSDDVer2.1

Metric ---For EU

Inch------For US

Metric ---For EU

Inch------For US

Page 13: ReleaseNote SDD Converter 8 28March2009

13

New Support (5) Support automatically setting machine name.

MiniSDDVer1.23

MiniSDDVer2.1

Based on SDD-J spec , it will be rename automatically. SDD-J support only number(1,2,3..) -character(A,B,C…)-Space -”-” .

(Ex)

HFP/1003--------------->HFP-1003

HFP_1030-------------->HFP-1030

HFP/1003*1------------>HFP-1003-1

Bend0(Small character)------->BEND0( Big character)

<Caution> If you have “Bend0”(Small character) or other special character in SDD-J ,you can not load converted parts in BENDCAM-AMNC side correctly.

Page 14: ReleaseNote SDD Converter 8 28March2009

14

New Support (6) Support automatically display rename dialog box for long name parts and special characters and Space character.

SDD-J MAX program name is 32 characters.

Also SDD-J do not support special characters.

(Ex.)

In case of special characters.

Please rename it in rename dialog based on SDD-J spec.

In case of long parts name over 32 characters.

Page 15: ReleaseNote SDD Converter 8 28March2009

15

(Ex.)In case of space characters.(Auto set in SDD-J as Non-space character)

Space character

Non Space character

MiniSDD SDD-J

Page 16: ReleaseNote SDD Converter 8 28March2009

16

New Support (7) Support automatically setting SUB-FOLDER.

New Version Dec/2006

Page 17: ReleaseNote SDD Converter 8 28March2009

17

New Support (8) Support Failed data report (TXT file)

It means “MiniSDD Crash data “ , you can see them by it.

New Version Dec/2006

For example , this is “SAME PARTS existing Error “ in SDD-J.

Page 18: ReleaseNote SDD Converter 8 28March2009

18

New Support (9) Support only AP100 CAD data

New Version Dec/2006

Page 19: ReleaseNote SDD Converter 8 28March2009

19

New Support (10) Support AMNC NOTE and MEMO (Bitmap) data

New Version Dec/2006

Page 20: ReleaseNote SDD Converter 8 28March2009

20

New Support (11) Support Install Shield Project New Version Dec/2006

You can install and Un-install in this time , we support SDD converter as install shield project in control panel.

Page 21: ReleaseNote SDD Converter 8 28March2009

21

New Support (12) Support More Speed up of converting

But you need update installation by new MiniSDD Ver1.23 or 2.1.

New Version Dec/2006

Old SDD Conveter

Ver Build 2006/Jun

Slow Speed by each Program searching in original logic.

New SDD Conveter

Ver Build 2006/Dec

High Speed by MiniSDD Method module at once.

But need MiniSDD updating.

Please see next “Procedure of SDD-J Converter steps” PAGE.

Page 22: ReleaseNote SDD Converter 8 28March2009

22

New Support (13) Support Root Program Auto set

New Version Dec/2006

Page 23: ReleaseNote SDD Converter 8 28March2009

23

New Support (13) Support to avoid BIG MEMORY LEAK

New Version 01/Feb/2007

We find some MEMORY LEAK(BMF) problem in “Sdd-12-12-06-Modif.sdd(Amada SA ROUSSEAU Customer data)”.

(36,873 KB)

We solved this inside error by this version.

if find to fail error , we do not add that into SDD.

But Again, if the data is too big , then there may be a possibility of NOT ENOUGH MEMORY.

Please note that if your MiniSDD data will be too big , it good to divide into two and convert.

Page 24: ReleaseNote SDD Converter 8 28March2009

24

New Support (14) Support an estimation time of conversion by the advancing bar New Version 09/May/2007

Page 25: ReleaseNote SDD Converter 8 28March2009

25

New Support (15) Support BEND0 default(MiniSDD) machine name changing New Version 09/May/2007

If we will find BEND0-BEND1-BEND…machine name (MiniSDD used name) ,Other machine name is same spec on auto renaming .We can change Machine name in Auto dialog box for your any machine name into SDD-J.

<SDD-J Machine name spec in DrABE-BEND –AP100 >

please enter “Within 20 characters with only “-(Hyhon)” and “.(dot) number (1,2--) and characters (A,B,C--).

Page 26: ReleaseNote SDD Converter 8 28March2009

26

New Support (16) Support auto set EU OS (IT-GE-SP-FR) program Files path New Version 09/May/2007

Page 27: ReleaseNote SDD Converter 8 28March2009

27

New Support (17) Support & symbol

Not Yet

Page 28: ReleaseNote SDD Converter 8 28March2009

28

New Support (18) Bug fixed AMNC Data (Angle/Direct/2D Shape ) after converting New Version 05/Mar/2009

In previous version,

After converting into SDD,

If you load

AMNC Angle/Direct/2D Shape programs , you had material missing dialog every time..

By 05/Mar/2009 version, it fixed.

Fixed

Page 29: ReleaseNote SDD Converter 8 28March2009

29

Procedure of SDD-J Converter steps

Page 30: ReleaseNote SDD Converter 8 28March2009

30

<STEP No-1>BACKUP MiniSDD Ver1.23 or Ver2.1 Data for safety.BACKUP Copy MiniSDD Folders for safety.

Page 31: ReleaseNote SDD Converter 8 28March2009

31

<STEP No-2>Install new MiniSDD Client Update Ver1.23(EU-US) or MiniSDDClient Update Ver2.1(US) in same installation place.Because we use new MiniSDD Method module for speed up or export error file(TXT).

Page 32: ReleaseNote SDD Converter 8 28March2009

32

<STEP No-3>Move-Copy MiniSDD ROOT programs.( Because SDD-J do not have ROOT folder. )

No need this operation.

New Support (13) Support Root Program Auto set, already it is OK!

Page 33: ReleaseNote SDD Converter 8 28March2009

33

<STEP No-4>Delete un-necessary FOLDER and PROGRAMS in SDD-J.

Page 34: ReleaseNote SDD Converter 8 28March2009

34

<STEP No-5> After version Up AP100 over Ver3.30-SP2

Restore AP100 parameter backup (Bend deduction –Material )

in AP100-Maitenance Center

If you have already it , you do not need this operation.<Caution>

If customer use MiniSDD Bend deduction table , please memo it in current version. And next please enter same bend deduction value in AP100-Simple mode bend deduction manager.

Page 35: ReleaseNote SDD Converter 8 28March2009

35

< STEP No-6> Check MiniSDD inside for SDD converter

<CAUTION>

SDD Converter does not support “Folder Inside Folder “ for SDD spec.

Page 36: ReleaseNote SDD Converter 8 28March2009

36

Page 37: ReleaseNote SDD Converter 8 28March2009

37

Page 38: ReleaseNote SDD Converter 8 28March2009

38

< STEP No-9> BENDCAM (SDD-J) License set.

Please check your BENDCAM License.

BENDCAM(SDD-J) do not need security block(Dongle).

Please contact new License with AESC stuffs.

Page 39: ReleaseNote SDD Converter 8 28March2009

39

< STEP No-10> BENDCAM Ver4.3(SDD) machine setting

Please set same machine name and spec in “Parameter

Machine registration – Machine Selection “ dialog.

Page 40: ReleaseNote SDD Converter 8 28March2009

40

< STEP No-11> Please set Dr.Abe parameter for customer setting.

Page 41: ReleaseNote SDD Converter 8 28March2009

41

About current miniSDD TOOLS(some fel files) , please copy it into SDD-J tool path.

<Tool Path>

MiniSDD tool path ---” C:¥Program Files¥Amada¥Tools¥UserFel”

SDD-J tool path-------”C:¥Asis1v11¥DATA¥BNDTOOL¥CURRENT”

If you copy them from MiniSDD path to SDD-J path, please backup original fel files for safety.

Page 42: ReleaseNote SDD Converter 8 28March2009

42

< STEP No-12> Please set same machine name in SDD-J(Data manager-Machine Manager) and DrABE parameter ( Machine registration).

Page 43: ReleaseNote SDD Converter 8 28March2009

43

After setting machine mane in SDD-J,

You can see and load converted data in AMNC Ver5 side.

Page 44: ReleaseNote SDD Converter 8 28March2009

44

CautionAfter MiniSDD to SDD converting…,

Please set SDDJ Connect Parameter (Input same machine name by converted SDDJ programs )in AMNC side. After it , You can load them by “All Machine “ sorting in AMNCV 5.

This is only SDDJ connect parameter without default machine type parameter . We recommend that you should load converted programs by “SDD Machine Name (Ex .HFP-1003 )“ sorting in AMNC V5. After re-saving in AMNC V5 with correct machine type , you can load them by “All Machine “ sorting in AMNCV 5.

You can use “All machine”correctly in AMNC V5 .

(Ex. In This case only “HFP-8025” by “All Machine” )

SDDJ Converted programs in Data manager. AMNC V5

AMNC V5 SDDJ Connect Parameter

(Ex. In This case only “HFP-8025”on SDDJ)

For other machine name ,please select correct machine name here without “All Machine”.

Page 45: ReleaseNote SDD Converter 8 28March2009

45

< STEP No-13> Please check converted BENDCAM programs as “Repeat” . And in AMNC side ,please check it.

Page 46: ReleaseNote SDD Converter 8 28March2009

46

< STEP No-14>

Remove SDDServer Service and Client (MiniSDD Ver1.23-Ver2.1)

Remove ToolEditor and Tools (MiniSDD)

MiniSDD Ver2.1 version up in AP100 PC.

Please copy all data to AMNC PC(Ver5) for Safety.

I recommend that you should remove MiniSDD Server and Client in AP100 PC. Because it is better to set one DB (SDD-J) in AP100 PC.

AP100 PCServer

(SDD-J)

AP100 PCClient

(SDD-J)

AMNC PCVer5

(MiniSDD Ver2.1)

No MiniSDD No MiniSDD

Page 47: ReleaseNote SDD Converter 8 28March2009

47

Trouble Shooting

Page 48: ReleaseNote SDD Converter 8 28March2009

48

<Trouble shooting>(1)CAN NOT start SDD-covert tool.

If you can not start SDD-J covert tool , first please check miniSDD register information.Sometimes it will be changed by any reason.

Also could you replace converter tool in Disk Top ? If you copy it in some folder places , it will have some

error and give application error message sometimes.

Page 49: ReleaseNote SDD Converter 8 28March2009

49

<Trouble shooting>(2)During converting into SDD-J , if you have “SQL error into SDD-J” , it means that some miniSDD data

will not be linked or will be crashed by some reason. In this case , it does not matter.

For example , after delete or move operation in MiniSDD some link will be crashed. In this case that I

recommend it is better to re-restore miniSDD (SDD file extension ) in “Program-AMADA-miniSDD

-Maintenance Utility”.

Please see New Support (8) Support Failed data report (TXT file)….You can see it by report file.

Page 50: ReleaseNote SDD Converter 8 28March2009

50

<Trouble shooting>(3) Error case of MiniSDD Ver1.23.

If you have application error in MiniSDD ver1.23 on converting , maybe some registry setting will be set .

Maybe Ver2.1 and ver1.23 both setting will be remained in your PC. In this case please delete “2.1” key in registry editor .

Page 51: ReleaseNote SDD Converter 8 28March2009

51

<Trouble shooting>(4) Error case of “AP100 AMNC and BENDCAM BACK-UP IS OVER”.

If you convert again in same environments , this error may be come as error message.

Causing is based on mixed environments on MiniSDD Ver1.2 and Ver2.1 in your PC.

In this case please delete “2.1” key in registry editor .