    Bottoming ORC Power Plant

    Davide Occello

    Introduction

    This report is about the construction of a model and the design of an OrganicRankine Cycle (ORC) Power Plant, bottoming an Internal Combustion Engine,which produces a hot mixture of water and glycol. The ORC has to be designed

    in order to maximize the economic benefit of the plant, and the following aimshave to be reached:

    1. Construction of the plants model and determination of the degrees offreedom

    2. Choice of the organic working fluid

    3. Imposition of some thermodynamic constraints

    4. Optimization of the cycle

    5. Calculation of the efficiencies

    6. Analysis of the effect of a different Water-Glycol mixture

    1

  • 7/27/2019 Relazione ORC

    2/17

    1 ORC Power Plant Scheme

    2

  • 7/27/2019 Relazione ORC

    3/17

    2 Construction of the plants model

    The idea used in the construction of the model is explained in the flow chartin figure 2. The coloured tiles express particular stages of the process such asinput parameters (purple) , constrained variables (yellow) and the optimizationfunction (green).

    As can be seen the different input variables have an effect only on some ofthe calculations, leaving the other untouched, this permits to run a more directoptimization.

    Now an detailed analysis of each peace of the plant will be done.

    Evaporation and Condensation pressuresUsing the tables extracted from SOLKANE for a given working fluid, an inter-polating function was written, so that any thermodynamic property could bedetermined using two variables in the superheated vapour zone and only onein the wet zone. In this way the calculation of the working pressures is shrunk to:

    Pevap = P(Tevap,wet)

    Pcond= P(Tcond,wet)

    Turbine

    Known the plants working pressures and the TIT (Turbine inlet temperature),

    which is the evaporation temperature (input parameter), the specific work canbe calculated as follows:

    Lturb = h2 h1 = iso(h2s h1)

    Obviously the enthalpyh1 = h, the saturated vapour enthalpy at the evap-

    oration temperature, while the h2s is calculated this way:

    h1 = h(Tevap, = 1)

    s1 = s(Tevap, = 1)

    h2s= h(s1, Pcond)

    The TOT (Turbine outlet temperature) can be now calculated:

    TOT =T(h2, Pcond)

    3

  • 7/27/2019 Relazione ORC

    4/17

    Figure 1: ORC Model Flow diagram

    4

  • 7/27/2019 Relazione ORC

    5/17

    Pump

    Similar calculations can be done also for the pump (isoentropic):

    Lpump= v1(Pevap Pcond)

    Where :

    v1= v(Tcond, = 0)

    The POT (Pump outlet temperature) can be now calculated:

    POT =Tcond+LpumpCp

    Heat exchanger notation

    In order to simplify the notation of the heat exchanger formulas the graph infigure 2 will be taken as a model.

    Figure 2: Heat Exchanger Scheme

    5

  • 7/27/2019 Relazione ORC

    6/17

    Evaporator

    The following procedure was used for the calculations in the evaporator:

    On the hot side (Water Glycol Mixture):

    Th2 = Th1 ( mhv)

    mwg Cpwg

    Where hv is the latent heat of evaporation a the given evaporation tempera-ture (input parameter), m is the ORC mass flow (input parameter) and w gsubscript indicates the Water-glycol mixture parameters.

    On the cold side (Evaporating organic fluid):

    Tc2 = Tc1

    So the graph in figure 2 can be plotted and the heat exchanger characteris-tics can be calculated:

    evap =Th1 Th2Th1 Tc1

    NTUevap = log(1 evap)

    Uevap = 2500 [W/m2K]

    ;

    Aevap =NTUevapCpwg mwg

    Uevap

    Condenser

    The condenser is composed of two sections, one in which the fluid is outside thewet zone, and one in which the fluid condenses, for this reason the calculationis a little bit more complex.

    Condensation zone

    On the cold side (Cold water):

    Tc2 = Tc1+ ( mhv)mw Cpw

    Where hv is the latent heat of evaporation a the given condensation temper-ature (input parameter), m is the ORC mass flow (input parameter) and wsubscript indicates the Cold Water parameters. Tc1 = 28 [C]

    6

  • 7/27/2019 Relazione ORC

    7/17

    Figure 3: Evaporator T-x diagram

    On the hot side (Condensing organic fluid):

    Th3 = Th2 = Tcond

    Cooling zone

    For the cooling zone we have different border conditions, such as:

    Tc3 = Tcond 2

    Tc2 andTh2 are known, so:

    Th1 = Th2+mwCpwmCp

    (Tc3 Tc2)

    Constraints The value ofTh1 calculated this way has to be lower than theTurbines outlet temperature. This constraint was applied because the modeldoesnt guarantee it and it is thermodynamically impossible to have the oppositecondition in a real plant.

    So the graph in figure 5 can be plotted and the heat exchanger characteristicscan be calculated:

    cond = Tc1 Tc2Th1 Tc1

    7

  • 7/27/2019 Relazione ORC

    8/17

    Figure 4: Condenser Model

    precond=Th1 Th2

    Th1 Tc2

    NOTE In the calculation of the efficacy of the heat exchangers, the formulais written in a way that permits to simplify the heat capacity.

    NTUcond = log(1 cond)

    precond(1 eNTUprecond(1Cr)

    (1 Cr eNTUprecond(1Cr) = 0 (Implicit calculation)

    Ucond= 2500 [W/m2K] Uprecond= 50 [W/m

    2K]

    Acond=NTUcondCpw mw

    UcondAprecond=

    NTUprecond(Cp m)minUprecond

    8

  • 7/27/2019 Relazione ORC

    9/17

    Figure 5: Condenser T-Q diagram

    Regenerator

    The regenerator was approached as every other heat exchanger, with the simpli-fication of the face that the mass flow is the same on both sides of the exchanger.

    The border conditions were the following:

    Th1 = TOT(Turbine outlet temperature)

    Tc1 = POT (Pump outlet temperature)

    Th2 = P re CIT (Pre-Condenser inlet temperature)

    And so with a simple energy balance the Tc2 can be calculated:

    Tc2 = Tc1+ (CphCpc

    )(Th1 Th2)

    And the heat exchanger characteristics are:

    reg (1 e

    NTUreg(1

    Cr)

    (1 Cr eNTUreg(1Cr) = 0 (Implicit calculation)

    Ureg = 50 [W/m2K] Areg =

    NTUreg(Cp m)minUreg

    9

  • 7/27/2019 Relazione ORC

    10/17

    Figure 6: Regenerator T-x Diagram

    Pre-Heater

    The pre-heater works between the following border conditions:

    Th1 = EOTh (Evaporator Outlet Temperature - Hot side)

    Tc1 = ROTc (Regenerator Outlet Temperature - Cold Side)

    Tc2 = Tevap (Evaporation Temperature)

    And so with a simple energy balance the Th2 can be calculated:

    Th2 = Th1 ( mCp

    mwCpw)(Tc2 Tc1)

    And the heat exchanger characteristics are:

    PH(1 eNTUPH(1Cr)

    (1 Cr eNT UPH(1Cr) = 0 (Implicit calculation)

    UPH= 600 [W/m2K] Areg = NTU

    PH(Cp m)minUPH

    10

  • 7/27/2019 Relazione ORC

    11/17

    Figure 7: Preheater T-x Diagram

    3 Choice of the organic fluid

    In order to maximize the economic benefit of the plant, the choice of the work-ing fluid is crucial. The choice was run over a wide range of candidates fromthe SOLKANE database, and a comparison of the various characteristics of thedifferent fluids was analysed.The fluid has to comply to the following characteristics:

    In the wet zone atTevap andTcond

    High ratio (High turbine specific work)

    Possibly small evaporation pressure (< 20 bar) for mechanical reasons

    Possibly condensation pressure around 1 bar

    The first condition is the most important because without is the cycle cannotwork, so a first selection of fluids was done on that criteria.

    Then a comparison of the remaining fluids was done on the basis of the secondcriteria, and was chosen the fluid which had the maximum , the R365mfc. Infact, choosing two mock evaporation and condensation temperatures within themaximum range (93 - 28) the pressure ratio = Pevap/Pcondwas maximum forR365mfc.

    11

  • 7/27/2019 Relazione ORC

    12/17

    Moreover the fluid complied to the other conditions also, and so it was chosenas the best candidate to test.

    4 Thermodynamic Constraints

    Because of the fact that the model has 4 degrees of freedom, it could go alsoin places where there is no thermodynamic meaning, and so in order to keep acertain degree of realism in the simulation the following constraints were intro-duced:

    All the [0;1]

    All Areas < 100m2

    Pre-CIT TOT (as said before)

    Mass flows under 25 [kg/s]

    5 Optimization

    The optimization was conducted manually, aiming to maximize the economicbenefit of the plant. The optimization function (Back time) was calculated asfollows:

    Pnet= m(Lturbgeninv mec Lpump

    pumpelp,gen) Paux

    Pturb = m(Lturbgeninvmec)

    Ppump= m( Lpump

    pumpelp,gen )

    Data

    Capital cost Se=200000 [euro]

    Electricity Selling price Sen= 0.28 [euro/kWh]

    Electricity Buying price Sst = 0.11 [euro/kWh]

    Water price Cw=1.7 [euro/h]

    Working time tw=7500 [h/year]

    Fixed costs Oemc=3500 [euro/year]

    Variable costs Oemv=0.03 [euro/KWh]

    Paux= 6 [kW]

    12

  • 7/27/2019 Relazione ORC

    13/17

    Economic Balance

    IncomeI=Sen Pturb tw [euro/year]

    CostsOem = Oemv Pnet tw [euro/anno]Oaux= (Paux+ Ppump) tw Sst [euro/anno]Ow = tw Cw

    Annual EarningsR= I (Oemc +Oemv+ Oaux+Ow)

    Backtimetritorno = Se/R

    Free variables

    The free variables chosen for the model are :

    Tevap Evaporation Temperature

    Tcond Condensation Temperature

    mMass flow of the main cycle

    mw Mass flow of the cooling water

    Temperature range In order to optimize the cycle the Temperature rangewas extended as possible, until the area of the heat exchangers began to be toohigh. This because the higher the temperature range is, the higher the powerand the efficiency of the cycle could be.

    Main cycle mass flow The mass flow of the main cycle acted directly tochange the power of the plant, so increasing it was wanted, but the problemwas that with too high mass flow the other constraints were not met, mainlythe 3rd one (Pre-CIT TOT), but also the areas exploded.

    Cooling Water Mass flow This mass flow was one of the only parametersthat could permit to increase the plant power, by permitting to increase themain cycle mass flow, and so it was brought to the maximum.

    13

  • 7/27/2019 Relazione ORC

    14/17

    The final values

    Tevap = 89 [C]

    Tcond = 32 [C]

    m= 1.05 [kg/s]

    mw = 25 [kg/s]

    Results

    Pnet= 14.7 [kW]

    tritorno = 10.24 [years]

    Areas and efficiencies

    Evaporator Aevap = 35.6 [m2] evap = 0.83

    Condenser Acond= 27.1 [m2] cond = 0.48

    Pre-Condenser Aprecond= 43.0 [m2] precond= 0.77

    Regenerator Areg = 49.5 [m2] reg = 0.75

    Pre-Heater APH= 10.9 [m2] PH= 0.98

    6 Calculation of the efficiencies

    Carnot Efficiency

    carnot= 1(TcondTevap

    ) = 1305.15

    362.15= 15.7%

    Limit Efficiency

    lim=a Qa+ b Qb+ c Qc

    Qa+ Qb+ Qc= 14.2%

    Where:

    i = 1 i TcondTevap

    i=

    i

    i

    i = T

    m

    Tmin

    i = T

    m

    Tmax

    14

  • 7/27/2019 Relazione ORC

    15/17

    Figure 8: ORC Cycle T-s Diagram

    Qi are the absorbed heats

    As can be seen in the cycle in figure 8 the following simple relations:

    B = 1 TcondTevap

    A= 1

    A= (T2+T1)/2

    Tevap

    B = (T

    5+T5)/2Tcond

    B = 1

    And for the heat part, the following ones:

    QA= h2 h1

    QB =hBC h2

    QC=h3 hBC

    15

  • 7/27/2019 Relazione ORC

    16/17

    Real Efficiency at shaft

    re = 1 QoutQin

    = 13, 7%

    Where:

    Qin= h3 h1

    Qout= h5 h6

    Real Electrical Efficiency

    el=LnetQin

    = 7, 02%

    Where:

    Qin= 209, 87500 = 1.57 [GWh/anno] is the inlet heat

    Lnet = 14, 7 7500 = 0.11 [GWh/anno] is the work after the efficiencychain

    Combined Plant Efficiency

    Because of the fact that this is a bottoming ORC cycle, the overall efficiencyof the plant will be defined by the following equation, given a certain efficiency

    of the topping cycle:

    comb = LtotQin,ICE

    = LICE+ LORC

    LICE+ Qcool+ Qrad+ Qth= 43, 6%

    WhereICE= 42, 5%,LICE= 5827500,LORC= 14, 77500,Qth= 4967500,Qcool= 2357500 , Qrad = 567500

    16

  • 7/27/2019 Relazione ORC

    17/17

    7 Analysis of the effect of the water-glycol mix-

    tureThe glycol mass fraction in the hot source had an effect on the cycle overall.This was because the glycol is fairly less dense and has also a lower cp thanwater. So leaving the MATLAB routine unchanged, increasing the glycol massfraction, the overall heat capacity of the hot flow lowered imposing a moreefficient heat exchanger to compensate. This led to an increase in the area ofboth the Evaporator and the Pre-Heater, as showed in figure 9.

    Figure 9: Effect of the Glycol mass fraction in the hot source water

    On the other hand

    17