regenacr kits - lcrhealcrhea.ro/data/brosura regenlab dermatologie.pdf · en budron b2 ch-1052 le...
TRANSCRIPT
RegenACR® treatment:Revitalizes and regenerates dermisSmoothes out wrinkles and foldsInduces new collagen productionDr Alain Gondinet, Paris
RegenACR® KitsAUTOLOGOUS CELLULAR REGENERATION
Regen Lab SAEn Budron B2CH-1052 Le Mont-sur-LausanneSWITZERLAND
aesthetics
T. +41 21 864 01 11F. +41 21 864 01 10 [email protected]
Product Reference Description Set/Component
0123 - Medical Devices Class IIb
RegenACR® Classic1 Safety–LokTM Butterfly needle 1 Collection holder1 RegenBCT tube1 x 2 ml ampoule of 10% calcium gluconate1 Luer-LokTM syringe 3 ml, 1 red transfer needle. 2 x 30 G needles for injection 2 x 4 mm, 27 G needle for mesotherapy1 Transfer device
R-ACR C1/B
This minimal invasive skin treatment is designed to with-draw blood from the patient and prepare 4 ml of Autologous Platelet Rich Plasma (A-PRP). It’s recommended for meso-therapy, fine wrinkles and alo-pecia treatments.
RegenACR® Extra1 Safety–LokTM Butterfly needle ,1 Collection holder,2 RegenBCT tubes*, 1 x 2 ml ampoule of 10% cal-cium gluconate,2 Luer-LokTM syringes, 1 ml (1) and 5 ml (10),1 Red transfer needle, 3 x 30 G needles for injection, 1 x 4 mm, 27 G needle for me-sotherapy,1 x 80 mm transfer cannula,1 Transfer device,1 Compressed paper mask.
R-ACR C2/B
RegenACR® Extra is designed to prepare 2 x 4 ml of Autologous Platelet Rich Plasma (A-PRP). It’s recommended for expanded mesotherapy as well as fine wrinkles & alopecia treatments.Also includes a compressed pa-per mask for facial application once poured with A-PRP.
RegenACR® Plus1 Safety–LokTM Butterfly needle, 1 Collection holder,2 RegenBCT tubes*,1 RegenATS tube* ,1 Transfer device,1 x 1 ml Luer-LokTM syringe,1 x 80 mm transfer cannula,3 x 30 G needles for injection,1 x 4 mm, 27 G needle for me-sotherapy,1 Red transfer needle,2 x 5 ml Luer-LokTM syringes.
R-ACR C/BA
RegenACR®Plus is designed to prepare 2 x 4 ml Autlogous Plate-let Rich Plasma (A-PRP) and 1 x 4 ml autologous thrombin serum (ATS). It’s recommended for me-sotherapy, fine wrinkle and fold augmentation treatments.
5m
l
4m
l
3m
l
2m
l
1m
l
5m
l
4m
l
3m
l
2m
l
1m
l
1m
l
0.2
0.1
0.3
0.4
0.5
0.6
0.7
0.8
0.9
aesthetics
*Tubes capacity = 8ml
En Budron B2 CH-1052 Le Mont-sur-Lausanne ! Switzerland T. +41 21 864 01 11 F. + 41 21 864 01 10 ! www.regenlab.com
Product Reference Description Set/Component
RegenACR® Cellular Mask Advanced6 x Cream potsAqua, Glyceryl stearate, Hydrogenated polydecene, Stearic acid, Vitis vinifera seed oil, Propylene gly-col, Hydrogenated vegetable oil / Glycine soja oil, Squalane, Persea gratissima oil, Asiaticoside/Madecassic acid / Asiatic acid (centella asiatica), Algin, Triethanolamine, Fragrance (Perfume), Cetyl palmitate, Methylisothiazolinone, Allantoïn, To-copheryl acetate, Disodium EDTA, Retinyl palmi-tate, Dipropylene Glycol, Decylene glycol, Sodium chloride, Citral, Coumarin
*Tubes capacity = 8ml
R-ACR CMC/B
This non-invasive skin treat-ment includes a special cream which can be applied on face, décolleté and hands after be-ing mixed with plasma. Recom-mended post-laser, post peeling and post-mesotherapy.
aesthetics
En Budron B2 CH-1052 Le Mont-sur-Lausanne ! Switzerland T. +41 21 864 01 11 F. + 41 21 864 01 10 ! www.regenlab.com
Mesolift:Firm up skin RegenACR® Plus
Deep wrinklesand folds
RegenACR® Cellular Mask Advanced & RegenACR® Extra paper maskPost laser and hydration
Fine wrinklesand folds
RegenACR® Classic & Extra
Regenlab PRP-Centri RGL-PRP-C
Tabletop centrifuge, max speed: 4000 r/min. Rotor imbalance protective device. Door switch & mechanical safety lock.
Medical Devices
En Budron B2 CH-1052 Le Mont-sur-Lausanne ! Switzerland T. +41 21 864 01 11 F. + 41 21 864 01 10 ! www.regenlab.com
RegenBCT Tube Properties
RegenACRPROCEDURE
Centrifugation: 5 min
2
Plasma supernatant
Cellular sediment
Cell Selector Gel
Red blood cells
3
1point of care, in 10 minutes
IVD
Regulated by EU Directive 98/79/EC
List A and B devices off list
Special symbol IVD required
Not allowed for clinical use
No test required biocompatibility
No clinical assessment
MDD
Regulated by Directive 93/42/EEC
Class I, Is, Im, IIa, IIb, III
Special symbol required CE 0123
Approved for clinical use
Complete required biocompatibility test (ISO 10993)
Clinical evaluation required (MEDDEV 2.7.1)
RegenBCT TUBES COMPARED TO OTHER CONVENTIONAL TUBES FOR IN VITRO DIAGNOSIS (IVD)
PRP VOL PER TUBE
4 to 5 ml
BLOOD VOLPER TUBE
8 ml
PLATELET RECOVERY
> 80 %
RED BLOOD CELL REMNANT
< 0.3 %
PLATELET CONCENTRATION
FACTOR (NATIVE)
1.6 X
SYSTEM SPECIFICATIONS
Simplicity: Only a few steps are required to pre-pare 4 to 5 ml of Autologous Platelet-Rich Plasma (A-PRP).
Low Blood Volume Required: RegenACR® Kit is designed to prepare Autologous Platelet Rich Plasma from only 8 ml of blood. Optimum Platelet Recovery: RegenACR® Kit you recover around 80% of the platelets from the whole blood. Platelets are concentrated in 1
to 5 ml of autologous plasma (depending on the required platelet concentration). Consistent Isolation of PRP: RegenACR® Kit uses a physical barrier (thixotropic gel) to separate the red blood cells from the plasma and the cellular sediment. The preparation is safe and consistent. Red Blood Cell Depletion: The level of Red Blood Cells is drastically reduced, with more than 99,8% of complete Red Blood Cell removal.