references 2013 wide programme · pdf filewvterm has s tŰv certificate ad- merkblatt hp 0 and...
TRANSCRIPT
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
1
WV term
E-mail Adress: [email protected] Predstavitev: www.wvterm.si
TRADE MARKS:
STADLER TVT®
Bioflamm ®
COMPANY PRESENTATION REFERENCES
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
2
WV term
PRESENTATION – OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company’s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT® trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z-9670961. Besides this trademark we are also present in the wood biomass market with Bioflamm® and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on top-class laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors.
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
3
WV term COMPANY IN PICTURES
COMPANY DATA ValueYearly turnover 4,8 mio Number of employees 68 Export 43% IExport in EU 38% Domestic market 57% Turnover with products 81% Turnover with services 19% Employees with high education 8 Employees with middle education 20 Qualified workers 28 Trained workers 12 Technology and development 7 Research and development group 3 ISO 9001 modul B and D yes Service for quality yes
Own boiler testing room up to 50 kW
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
4
WV term MASCHINERY EQUIPMENT
EQUIPMENT/MASCHINERY VALUELaser cutting maschine 3000 V table 2 x 4 m Laser cutting maschine 3000 V table 1,5 x 3 m Plasma cutting maschine 2 x 2000 V table 2 x 8 m Welding robot 2 x table 0,7 ton Welding automat 2 CNC bending maschine 250 ton CNC bending maschine 200 ton CNC curving maschine d=8 mm Curving maschine d=14 mm CNC maschine for cutting tubes and sticks 400 mm
Maschines for forming the tubes 3 Hidraulic bending maschine 250 ton Shears for cuttin up to thickness 12 mm
Boring maschine up to 100 mm 4
Fres maschine 1 Lathmaschine 400 mm L=3 m 2 Puls welding appliance 10 Enamel finish 1 Crane up to 30 tons 2 Crane up to 5 tons 4 Forkmaschineup to 4 tons 4 Trucks up to 5 tons 2 Service vehicles 5 Production surface 4.500 m2
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
5
WV term REFERENCES WVterm has s TŰV certificate AD- Merkblatt HP 0 and certificate TRD 201, tis helps the company to produce tipicaly certified boilers and vessels under higher pressure. The company has become the certificate in accordance to Standard ISO 9001 modul B and modul D, which emphasizes the qualifications of the company for the production of boilers. In accordance with the slovene legislation WVterm has the certificate that it is qualified for boiler welding and production of high pressure vessels. Tha Company ha salso golden sign for the product quality SQ. We have many patents and trade marks protected at the Bureau of industrial property. We produce over 3.000 pieces of boilers yearly, the capacity varries from 12 kW to 6.000 kW, among them there are over 100 pieces of boilers with capacity from 200 kW to 6.000 kW. Lately we encrease the production of boilers for biomass . We V zadnjem času se močneje širi proizvodnja kotlov na biomaso, kar velja tudi za slovenski trg. Through our domestic partner in Germany we cover the markets in all European countries. Our biggest devices from 3 MV up to 6 MV work in Germany, Netherlands, Italy and Russia. The greatest meaning in our economical position has our export, that is why we strive after high business and high quality. Our Sale to former Yugoslav markets is higher from year to year. The trade mark STADLER is on this markets still appreciated. Graf 1 The company exports over 60 % of its yearly production, 55 % is exported to european Union. Special Refference is Projekting and control of Instalation in Hospital in Jakutsk Russia, area over 50.000 m2. Projekt was made throug Biro 71 Ljubljana in the Yaer 1995.
NEMČIJA42%
AVSTRIJA13%
BOSNA4%
SRBIJA2%
HRVAŠKA0%
SLOVENIJA39%
REALIZACIJA PO DRŽAVAH
NEMČIJA
AVSTRIJA
BOSNA
SRBIJA
HRVAŠKA
SLOVENIJA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
6
WV term
REFERENCE LIST OF DEVICES ON BIOMASS FUEL
Type of device Fuel Kapacity in kW Buyer State SR-EB 4 / V4 E pellets 200 PLANINSKI MUZEJ MOJSTRANA SLOVENIJA SR-EB 4 / V4 E wood chip 200 ŽG LJUBLJANA SLOVENIJA SR-EB 5 / V5 E wood chip 300 DETA SLOVENIJA SR-EB 5 / V5 E wood chip 300 TRGOCEV SLOVENIJA SD 5/FLUID Eragon dry sawdust 300 PABLES SLOVENIJA SR-EB 6 / V6 E wood chip 400 KAGER HIŠE SLOVENIJA SR-EB 6 / V6 E pellets 400 DIJAŠKI DOM DRAVA SLOVENIJA SR-EB 6 / V6 E wood chip 400 ŠPORTNI CENTER DRAŠ SLOVENIJA TR-EB 6 / V6 E wood chip 400 COMTRON IN SLOVENIJA TR-EB 6 / V6 E wood chip 400 OŠ PUCONCI SLOVENIJA SR-EB 7 / V7 E wood chip 500 SIRIUS SLOVENIJA VA 7/ FLUID Eragon dry sawdust 600 MIZARSTVO MAKOVEC SLOVENIJA SR-EB 6 / V6 E parni 0,5 bar wood chip 600 / 800 kg pare/ h TOPP SLOVENIJA SR-EB 8 / V8 A wood chip 750 PRELOG SLOVENIJA SR-B8 SW / V8-E wood chip 750 ECOM RUŠE SLOVENIJA TR B8 (N) / V8 A wood chip 750 SOBERNHEIM NEMČIJA SR-EB 8 / V8 E peleti 750 VITEZ BiH SR-EB 8 / V8 A peleti 2 x 750 BRČKO BiH SRF-RKP 750 parni kotel 4,0 bar wood chip 750 / 960 kg pare/ h SIRARNA BOHINJ SLOVENIJA VA 10/ FLUID Eragon dry sawdust 1.100 JOŠT HOTEL SLOVENIJA SRF-RK 860 wood chip 860 KEMIJSKA ŠOLA RUŠE SLOVENIJA TRF-RK 1100 wood chip 1.100 OSL REWE NEMČIJA TRF-RK 1100; SRF-RK 520 wood chip 1.100+520 WVterm SLOVENIJA TR EB 10 / V10 E wood chip 1.100 SESLACH NEMČIJA VA 11/ FLUID Eragon dry sawdust 1.250 CELES SLOVENIJA VA 11/ FLUID Eragon dry sawdust 1.250 RIKO HIŠE SLOVENIJA TREB 11,/ SR-EB 7 / V7 E Mitraka wood chip 1.250+600 AHA EMI SLOVENIJA SR-B11 SW / V11 A 6 bar wood chip 1.250 KREUTH NEMČIJA TRB 11 / V11 A wood chip 1.250 GG NOVO MESTO SLOVENIJA TRF-RK 1250 wood chip 1.250 PROFILES SLOVENIJA SR-EB 11 / V11 E wood chip 1.250 DELNICE HRVAŠKA SR-EB 12 / V12 E wood chip 1.500 SCHLESWAG AVSTRIJA SR-EB 12 / V12 E wood chip 1.500 REMA / TORKIN BELGIJA TR B12 (N) / V 12A wood chip 1.500 RAALTE NIZOZEMSKA TRF-RK 1500 wood chip 1.500 KOZJE daljinsko ogrevanje SLOVENIJA SR-EB 13 / V13 E wood chip 1.750 NAHOMA ROHA FINSKA SR-EB 13 / V13 E wood chip 1.750 MILANO ITALIJA SR-EB 13 / V13 E wood chip 1.750 REFRONTOLO ITALIJA SR-EB 13 / V13 E wood chip 1.750 PIOBESI TORINESE ITALIJA SR-EB 13/ V13 E wood chip 1.750 ETHON VEL. BRITANIJA TREB 13 Eragon 4,5 bar wood chip 1.600 KOPITARNA SLOVENIJA VA 13/ FLUID Eragon 4,5 bar dry sawdust 1.600 TUS KOSI SLOVENIJA TRB 14 / V14 A wood chip 2.000 EFFETTI ITALIJA TRB 14 / V14 A wood chip 2.000 GORENJE MARLES SLOVENIJA TRF-RK 2000 Mitraka wood chip 2.200 TERME OLIMJA SLOVENIJA TRF-RKP 2000 parni kotel 6 bar wood chip 2.000/3000 kg pare/ h VITIVA SLOVENIJA TRB LK 15 wood chip 2.200 SUŠILNICA BIOMASE TRGOVIR BiH TRB 15 / V 15A wood chip 2.250 ILMES SLOVENIJA TRB 15/V 15A wood chip 2.588 ČARDAK daljinsko ogrevanje SLOVENIJA TRB 15/V 15A wood chip 2.588 WARENDORF NEMČIJA TRB 30 /V 30A wood chip 3.000 NIEUWEWEG NEMČIJA TRB /V 30A wood chip 3.000 TAMAI DI BRUNERA ITALIJA TRB 35/V 35A wood chip 3.500 BATTAGLIA ITALIJA TR EB 15 + TR EB 12 wood chip 2.200+1.500 Bolnica MINDEN NEMČIJA TRB 15/V 15+ V 11/TRB 11 wood chip 2.588+1.500 INLES RIBNICA SLOVENIJA TRB 25 wood chip 2.500 SUŠILNICA BIOMASE TRGOVIR BiH TRB 30 / V30 A wood chip 3.000 FIS VITEZ BiH TRB 30 wood chip 3.000 GRAFENEK SUŠILNICA ŽIT AVSTRIJA TRB LK 30 wood chip 2x3.000 OZL SUŠILNICA ŽIT UKRAJINA TRB LK 30 wood chip 3.000 SUŠILNICA ŽIT SLOVENIJA TRB 45 wood chip 4.500 MENEGOLO ITALIJA TRB 60 / V 60 wood chip 6.000 BAUTEX RUSIJA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
7
WV term
COMPLIENCE WITH THE REGULATIONS FOR BIOMASS BOIKERS Stack gas emissions The design of the boiler control "Bioflamm-Lambdamatika or Optimatik +" by the lambda probe and multiciklon ensure that the device will operate with high efficiency, emission of flue gases will be in accordance with the requirements (Official Gazette 34/07, Official Gazette of RS 73/94, 105 / 00, 84/02 and amedments of the Official Gazette of RS 51/98). emitted substance MEV v mg/m3 pri 11% O2 vol. total dust 1 Heat loss from the flue gases 175 Total dust 20 – 60 v odvisnosti od moči kotla carbon monoxide (CO) at rated power 150 Nitrogen oxides (NOx) expressed as NO2 250 Sulphur oxides (SOx), expressed as SO2 1000 Organic compounds expressed as total organic carbon (TOC)
10
Konstruktional implementation Safety Technical derivation of Bioflamm combustion plant according to TRD 414 section 1.6 and 1.7: Devices that are licensed and are operating from a TÜV-tested, are equipped with guards metering of electrical drives with self-control, safety buffer. For closed heating installations according to DIN 4751 and TRD 702 device meets the prescribed implementation of district heating system, which has proven parts. • The two-step temperature controller and • Safety temperature limiter according to DIN 3440 • The safety valve according to TRD 721 and • sensor min. and max. pressure
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
8
WV term STUDENT HOME DRAVA MARIBOR
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
9
WV term STUDENT HOME DRAVA MARIBOR
Technical Data Type of device SREB6/VE6Kapacity of boiler 400 kWType of fuel pelletsFuel moisture max. 12%Emission of dust in smoke gases 60 mg/m3
Transport of the fuel Worm convayorPellets silo 90 m3
Consumption of fuel out of the tank with movable base
Hidravlic cylinder � 160 mmHot water acumulator 2x3000 lYear of installation 2012
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
10
WV term
BOILER HOUSE GORENJE MARLES Maribor
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
11
WV term BOILER HOUSE GORENJE MARLES Maribor
Technical Data Type of device TRB14/VA14Kapacity of boiler 2.000 kWType of fuel Wood chipsFuel moisture max. 45 %Chip size G 50Emission of dust in smoke gases 80 mg/m3
Transport of the fuel conveyorThe fuel storage room 180 m3
Consumption of fuel out of the tank with movable base
Hidravlic cylinder �2x�200 mmHot water acumulator 30.000 lYear of installation 2009
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
12
WV term
ALP MUSEUM MOJSTRANA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
13
WV term ALP MUSEUM MOJSTRANA
Technical Data Type of device SREB4/VE4Kapacity of boiler 200 kWType of fuel pelletsFuel moisture max. 12%Emission of dust in smoke gases 60 mg/m3
Transport of the fuel z polžiThe fuel storage room 50m3
Consumption of fuel out of the tank spring coverHidravlic cylinder Hot water acumulator 2x3000 lYear of installation 2010
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
14
WV term
DISTRICT HEATING ČRNOMELJ - ČARDAK
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
15
WV term DISTRICT HEATING ČRNOMELJ - ČARDAK
Technical data
Type of device TRB15/VA15Kapacity of the boiler 2.200 kWType of fuel Wood chipsFuel moisture max. 45%Chip size G 50Emission of dust in smoke gases 80 mg/m3
Transport of the fuel conveyorThe fuel storage room 250 m3
Consumption of fuel out of the tank
with movable base
Hidravlic cylinder 4 x 200 mm
Hot water acumulator 40.000 lYear of installation 2007
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
16
WV term
STEAM BOILER HOUSE VITIVA MARKOVCI
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
17
WV term STEAM BOILER HOUSE VITIVA MARKOVCI
Techical data Type of device TRF RKP 2000Kapacity of boiler 2.200 kWKapacity of steam 3,500 kg/hSteam operating pressure 8 barEmission of dust in smoke gases
20 mg/m3
Fuel type Wood chipsFuel moisture max. 45%Chip size G 50Transportation of fuel conveyorThe fuel storage room 2x250 m3
Consumption of fuel out of the tank with movable base
Hidraulic cylinder 2 x 3 x 200 mm
Year of installation 2012
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
18
WV term
CEREAL DRYING HOUSE ŠKAPER VANEČA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
19
WV term CEREAL DRYING HOUSE VANEČA
Technical data Type of the device TRB LK 30Kapacity of boiler 1.980 kWEmission of dust in smoke gases 80 mg/m3
Kapacity of drying 15 ton/hTemperature of drying 120 °CVertikal heat exchanger 1.980 kWAir flow through the exchanger 65.000 m3/hType of fuel Wooden chipsFlue moisture max. 45%Chip size G 50Transportation of the fuel conveyorThe fuel storage room 190 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 3 x 200 mm
Reserve fuel Natural gasYear of installation 2013
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
20
WV term
PRIMARY SCHOOL PUCONCI
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
21
WV term PRIMARY SCHOOL PUCONCI
Technical data Type of the device TRB6/V6EKapacity of the boiler 400 kWFuel type Wooden chipsFuel moisture max. 45%Chip size G 30Emission of dust in smoke gases
80 mg/m3
Transportation of fuel conveyorThe fuel storage room 120 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 2 x 200 mm
Year of installation 2013
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
22
WV term BOILER HOUSE OLIMIA SPA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
23
WV term BOILER HOUSE OLIMIA SPA
Tehnični podatki Type of the device TRF RK 2000Kapacity of the boiler 2.000 kWFuel type Wooden chipsFuel moisture max. 60%Chip size G 50Emission of dust in smoke gases
20 mg/m3
Transportation of fuel conveyorThe fuel storage room 300 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 3 x 200 mm
Warm water acumulator 50.000 lYear of the instalation 2011
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
24
WV term DISTRICT HEATING KOZJE
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
25
WV term DISTRICT HEATING KOZJE
Technical data Type of the device TRF RK 1500Kapacity of the boiler 1.500 kWFuel type Wooden chipsFuel moisture max. 60%Chip size G 50Emission of dust in smoke gases
20 mg/m3
Transportation of fuel conveyorThe fuel storage room 350 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 3 x 200 mm
Warm water acumulator 50.000 lYear of the instalation 2013
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
26
WV term BOILER HOUSE FIS VITEZ BOSNA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
27
WV term BOILER HOUSE FIS VITEZ BOSNA
Technical data Type of the device TRB 30/VA 30Kapacity of the boiler 3.000 kWFuel type lesni sekanciFuel moisture max. 80%Chip size G 50Emission of dust in smoke gases
80 mg/m3
Transportation of fuel transportni trakThe fuel storage room 450 m3
Consumption of fuel out of the tank pomična dna
Hidraulic cylinder 3 x 200 mm
Warm water acumulator Year of the instalation 2011
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
28
WV term BOILER HOUSE FIS BRČKO BOSNA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
29
WV term BOILER HOUSE FIS BRČKO BOSNA
Technical data Type of the device SREB 8/VE8Kapacity of the boiler 2x750 kWFuel type pelletsFuel moisture max. 10%Chip size Emission of dust in smoke gases
80 mg/m3
Transportation of fuel conveyorThe fuel storage room 250 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 2 x 200 mm
Warm water acumulator Year of the instalation 2010
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
30
WV term BOILER HOUSE GG NOVO MESTO
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
31
WV term BOILER HOUSE GG NOVO MESTO
Technical data Type of the device TRB 12/VA 12Kapacity of the boiler 1.250 kWFuel type lesni sekanciFuel moisture max. 80%Chip size G 50Emission of dust in smoke gases
80 mg/m3
Transportation of fuel transportni trakThe fuel storage room 450 m3
Consumption of fuel out of the tank pomična dna
Hidraulic cylinder 3 x 200 mm
Warm water acumulator 30.000 lYear of the instalation 2009
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
32
WV term GRAMMAR SCHOOL RUŠE
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
33
WV term GRAMMAR SCHOOL RUŠE
Technical data Type of the device STRF RK 860Kapacity of the boiler 860 kWFuel type Wooden chipsFuel moisture max. 40%Chip size G 50Emission of dust in smoke gases
60 mg/m3
Transportation of fuel transportni polzThe fuel storage room 210 m3
Consumption of fuel out of the tank krožno zajemalo
Hidraulic cylinder Warm water acumulator 10.000 lYear of the instalation 2013
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
34
WV term AHA EMMI SLOVENSKA BISTRICA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
35
WV term AHA EMMI SLOVENSKA BISTRICA
Technical data Type of the device TREB 11+ SREB /VE8 Kapacity of the boiler 1.250+600 kWFuel type Wooden chipsFuel moisture max. 45%Chip size G 50Emission of dust in smoke gases
80 mg/m3
Transportation of fuel conveyorThe fuel storage room 310 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 3 x 200 mm
Warm water acumulator 30.000 lYear of the instalation 2009
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
36
WV term PRIMARY SCHOOL DELNICE CROATIA
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
37
WV term PRIMARY SCHOOL DELNICE CROATIA
Technical data Type of the device SREB 12/VE12Kapacity of the boiler 1.250 kWFuel type pelletsFuel moisture max. 10%Chip size G 50Emission of dust in smoke gases
60 mg/m3
Transportation of fuel transportni polzThe fuel storage room 190 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 2 x 200 mm
Warm water acumulator 10.000 lYear of the instalation 2012
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
38
WV term BOILER HOUSE PROFILES RAZDRTO
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
39
WV term BOILER HOUSE PROFILES RAZDRTO
Technical data Type of the device TRF RK 1250Kapacity of the boiler 1.250 kWFuel type Wood chipsFuel moisture max. 60%Chip size G 50Emission of dust in smoke gases
80 mg/m3
Transportation of fuel augerThe fuel storage room 280 m3
Consumption of fuel out of the tank Movable base
Hidraulic cylinder 3 x 200 mm
Warm water acumulator Year of the instalation 2012
STADLER TVT ® d .o.o.
Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279
40
WV term BOILER HOUSE PLANINA KRANJ
Technical data Type of the device Hot warter ZV Kapacity of the boiler 10.000+7.000 kWFuel type zemeljski plinTemperature regime 130/60 °CCNS for system Attached to cogeneration Year of installation 2012