reference manual - jim cox salesjimcoxsales.com/.../08/reference-manual-ims-mobile.pdf · ims...

50
Reference Manual and User’s Guide 1-800-888-1436 • gethurco.com [email protected] REFERENCE MANUAL mobile Version 1.0.0.6

Upload: others

Post on 31-May-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

www.GETHURCO.com

Reference Manual and User’s Guide

1-800-888-1436 • gethurco.com • [email protected]

R E F E R E N C E M A N U A L

mobile

Version 1.0.0.6

Page 2: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

www.GETHURCO.com

Page 3: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

www.GETHURCO.com

WelcomeThank you for purchasing Hurco’s Infrastructure Management System, IMS, software. IMS was developed to help you manage one of our most important infrastructures, water distribution. The IMS system was designed to be used with Hurco’s Fire Flow Pro for fire flow testing, unidirectional flushing, c-factor testing and Hurco’s Valve Star for valve exercising and management. This IMS software can also be used as a standalone system ready for you to enter data and create reports.

This software has many user friendly features including drop down menus and data selection fields, report editing, security features and much more. This software will give you every function you need to manage your water distribution system including valves, hydrants and mains.

IMS software modules include:• Hydrant and Valve Maintenance, included with base package.• Fire Flow Testing• C-factor Testing • Unidirectional Flushing• Valve Exercising• QSI Integration Module for Valve Star G4 and Fire Flow Pro QSI

This manual will take you through the step by step procedures for using the IMS software. We use simple to understand instructions and photos to assist you in learning how to get the best results from your IMS software. Please follow each step completely to insure you will get the valuable data, management tools and reports you expect.

The IMS system is designed for any size water distribution system and set up so you can generate your own custom reports using Crystal Reports. To get started, please read this manual front to back. If you need help getting started with your new IMS software, the staff at Hurco will be happy to assist you. We can set up training by Webex, telephone, fax, e-mail or even onsite training. Please call to learn more about our training programs. You will have unlimited Webex and telephone support for one year from your purchase date.

In this IMS software program, we give you numerous fields to collect and record important data about your water distribution system. As a general rule, these features are based on the recommendations of the American Water Works Association, (AWWA) and the National Fire Protection Association, (NFPA). It will be your responsibility to read and understand these recommendations. Hurco Technologies, Inc. will not be responsible for the incorrect collection of data or for the failure to follow AWWA and NFPA recommendations. Assign a competent worker with knowledge of your distribution system and capabilities to manage data in a software program. Always verify that the equipment you are using to collect data in the field is properly calibrated and certified.

To set up training or for general information regarding your new IMS software, call Hurco Technolo-gies, Inc. at 1-800-888-1436.

Sincerely,

Lyndon J. HurleyPresident, Hurco Technologies, Inc.

Welcome

Page 4: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

i

Table of Contents Installation ................................................................................................................................................... 1

System Requirements .............................................................................................................................. 1

Minimum System Requirements ..................................................................................................... 1

Installing the Program .............................................................................................................................. 1

Setting Up IMS Mobile ............................................................................................................................... 4

Hardware................................................................................................................................................... 4

Mobile RF Receiver ............................................................................................................................... 4

GPS Receiver ......................................................................................................................................... 4

Software .................................................................................................................................................... 5

Operator ID ........................................................................................................................................... 5

IMS Server Settings .............................................................................................................................. 5

GPS Settings ......................................................................................................................................... 6

Sensor Settings ...................................................................................................................................... 7

Spin Dr Settings .................................................................................................................................... 8

Syncing to IMS By Hurco ............................................................................................................................. 9

Clearing the Handheld ............................................................................................................................... 10

Maintenance .............................................................................................................................................. 12

Hydrant Maintenance ............................................................................................................................. 12

Adding a New Hydrant ....................................................................................................................... 12

Modifying a Hydrant .......................................................................................................................... 13

Valve Maintenance ................................................................................................................................. 12

Adding a New Valve ........................................................................................................................... 13

Modifying a Valve .............................................................................................................................. 14

Mains Maintenance ................................................................................................................................ 14

Adding a New Main ............................................................................................................................ 14

Modifying a Main ............................................................................................................................... 15

Fire Flow Test Maintenance .................................................................................................................... 15

Adding a New Fire Flow Test .............................................................................................................. 15

Modifying a Fire Flow Test ................................................................................................................. 15

C-Factor Test Maintenance ..................................................................................................................... 16

Adding a New C-Factor Test ............................................................................................................... 16

Page 5: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

ii

Modifying a C-Factor Test .................................................................................................................. 17

UDF Test Maintenance ............................................................................................................................ 17

Adding a New UDF Test ..................................................................................................................... 17

Modifying a UDF Test ......................................................................................................................... 18

Report Deficiencies .................................................................................................................................... 19

Adding a Hydrant Deficiencies ............................................................................................................... 19

Adding a Valve Deficiencies ................................................................................................................... 19

Conducting a Test ...................................................................................................................................... 21

Conducting a Fire Flow Test ................................................................................................................... 21

Conducting a Valve Exercise ................................................................................................................... 24

Conducting a Uni-directional Flush ......................................................................................................... 27

Conducting a C-Factor Test ..................................................................................................................... 30

Conducting a Hydrant Flush .................................................................................................................... 33

Conducting a Repair and Maintenance ................................................................................................... 34

Results ........................................................................................................................................................ 36

Exercise Results ...................................................................................................................................... 36

Fire Flow Results .................................................................................................................................... 36

C-Factor Results ...................................................................................................................................... 37

UDF Results ............................................................................................................................................. 37

Hydrant Stickers ...................................................................................................................................... 38

Help ............................................................................................................................................................ 39

About ....................................................................................................................................................... 39

Help Doc ................................................................................................................................................. 40

IMS Mobile Video User Guide ................................................................................................................ 40

Page 6: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

1

Chapter 1

Installation

System Requirements

• 1 gigahertz (GHz) or faster 32-bit (x86) or 64-bit (x64) processor

Minimum System Requirements

• 512 megabyte (MB) RAM (1 gigabyte (GB) Recommended) • 1.5 gigabytes (GB)

• CD-ROM or DVD drive

free hard disc space (application data entered by the user will take up additional space)

• 1 USB 2.0 port • 800 x 600 or higher resolution monitor • .Net framework 2.0 • Windows XP SP2 or higher • Adobe Reader

Installing the Program

1. To begin the installation of IMS Mobile, double click on the “setup.exe” file located on your installation CD (or downloaded file). Also temporarily shut down any antivirus programs to prevent interference during installation.

2. Click Next.

3. Click Install to start the installation process.

Page 7: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

2

4. Patiently wait for the program to install.

5. When installation has finished, click Finish.

6. Congratulations! You have successfully installed IMS Mobile.

Page 8: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

3

7. The first time you log into IMS Mobile you will be prompted for the activation code. Enter the

Activation ID and click Activate. You will need to contact Hurco Technologies, Inc to obtain your activation code if it was not given at the time of purchase.

Page 9: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

4

Chapter 2

Setting up IMS Mobile

Hardware Mobile RF Receiver

1. Plug mobile RF receiver into USB port.

2. If receiver is not recognized, you should be prompted to install the drivers for it. These are located on the disk for IMS Mobile.

3. Continue with next step after drivers have been installed.

4. Go to Control Panel, then System, then Device Manager.

5. Under Ports, find USB Serial Port (COMX). The “X” represents the comport number assigned to your RF receiver. The com port number will need to be remembered as it will be needed in IMS Mobile.

GPS Receiver

The GPS receiver that you used with IMS Mobile must report GPS data in the NMEA format. For best results, we recommend a GPS receiver based on the SiRF Star III GPS chipset.

1. If you intend to use a GPS receiver, plug it into a USB port.

2. If receiver is not recognized, you should be prompted to install the drivers for it. These drivers will need to be obtained from the manufacturer.

3. Once GPS receiver has been installed, follow the above directions to obtain the comport number which will also be needed for IMS Mobile. The name of the port will vary depending on which GPS receiver is being used.

Page 10: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

5

Software

Operator ID

This is the name of the person who will be using the mobile handheld. The setting can be changed at any time based on who is operating the handheld. Operators must be set up in IMS By Hurco.

1. Select the operator from the drop down list. 2. Click Save Data.

IMS Server Settings

IMS server setting is the path and credentials for your IMS by Hurco database. This database is the home of all information that has been entered into IMS by Hurco. For example, it holds all the hydrants that have been entered for use on tests. If you are unsure of any of these settings, please contact your IT administrator to obtain the correct settings.

Page 11: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

6

1. IMSServer – This is the network location of your IMS by Hurco database. By default, this location will be “IP address of PC where IMS by Hurco is installed\IMSBYHURCO”.

2. IMSDatabase – This is the name of the company created in IMS by Hurco. By default IMS by Hurco will remove any spaces that were entered in the company name so that it is all one word.

3. SQL or Windows Authentication – This determines what type of security you are using to access the IMS by Hurco Database. By default, IMS by Hurco uses SQL authentication.

4. IMSUser & IMSPass – If you chose SQL authentication, this will be the user name and password for the IMS by Hurco database. If you chose, Windows authentication, this will be the user name and password for the computer where IMS by Hurco is installed.

GPS Settings

GPS settings is the comport settings that were obtained earlier. If you are unsure of the settings, please reference your GPS manufacturer’s handbook.

Page 12: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

7

1. Com Port Settings a. Port Name – This is the name of the port that was obtained from the GPS when it was

installed. b. Baud Rate – By default, this is set to 9600 unless your GPS requires something else. c. Data Bits – By default, this is set to 8 unless your GPS requires something else. d. Parity – By default, this is set to 0 unless your GPS requires something else. e. Stop Bits – By default, this is set to 1 unless your GPS requires something else. f. Click Save to save the com port settings that were entered.

2. Test GPS Settings – Once the settings have been saved Click Start Test to test that your settings

are correct. Click Stop Test to end the test. If the test doesn’t locate a GPS reading, check your settings and rerun the test.

3. Calculate Distance – This allows you to check distances between two GPS readings. Click the first Capture. Move to the next location you want and click the second Capture button. Once you have both locations, click the Calculate button and it will calculate the distance between the two locations.

Sensor Settings

Sensor Settings is where you can set up all of the sensors that will be used with IMS Mobile.

1. Sensor Settings – This is where you will set up the sensors that will be used with the handheld.

a. Sensor – Choose the color of the sensor. This will be the color of the label on the front of the sensor.

b. SN – This is located on the back of the sensor.

2. Test Sensor – Once you have entered the Sensor and serial number you can test the sensor. Simply power on the sensor you wish to test and click the “Test Sensor” button.

Page 13: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

8

Spin Doctor Settings

Spin Doctor Settings is where you will set up which type of Spin Doctor you will be using with IMS Mobile.

1. Select which Spin Doctor you will be using. a. Type 1 – Your Spin Doctor has a Standard Head. b. Type 2 – Your Spin Doctor has a LCD Readout Head.

2. Select Save. 3. Testing GPS

a. Select Start Test to obtain GPS readings. b. Once you have received readings, you can select Stop Test.

RF Settings

RF Settings is where you will set up the communications port for the RF Receiver.

1. Com Port Settings a. Port Name – This is the name of the port that was obtained from the RF receiver when it was installed.

b. Baud Rate – Should be set to 9600. c. Data Bits – By default, this is set to 8.

Page 14: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

9

d. Parity – By default, this is set to 0. e. Stop Bits – By default, this is set to 1.

Mobile Mode

NOTE: In order to access the Mobile Mode screen and make changes. A password must be setup in IMS by Hurco under “Edit/Mobile Lock-Out Code”. Once you have setup a password in IMS by Hurco, you must first SYNC the handheld to IMS in order for that password to be active on the mobile device.

The Mobile Mode setting is where you will choose to “Lock” (not allow changes or adding of valves, hydrants, or mode to be made by unauthorized users) or “Unlock” (allow changes to be made by anyone). The Mobile Mode setting is also where you choose to place the handheld in Auto or Manual mode.

Auto Mode means that you are setup to use the Auto version of the Spin Dr. Manual Mode means that you will be using the standard Spin Dr.

Page 15: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

10

Chapter 3

Syncing to IMS by Hurco Before taking the handheld to the field for testing, you will need to sync it to IMS by Hurco. This will import the information from the company you selected earlier in IMS Server settings. As a precaution, we recommend backing up IMS by Hurco database before syncing handheld. You will also need to sync the handheld to IMS by Hurco once you return from the field.

WARNING: You must make sure you have the correct company in the IMS server settings before syncing. If you have the wrong company selected and you sync, it will import the information to whatever company you selected in the settings. For example, if you have selected Samplecompany1 in the settings but the information should go to Samplecompany2, it will write that information to Samplecompany1.

1. To start the syncing process, go to Actions. Select Sync to IMS.

2. The following warning will appear once you have selected Sync to IMS. If you wish to continue, select Yes. If you do not want to continue, select No. If you select No, the sync process will not move forward.

3. After selecting Yes, you will be taken to the sync screen. To begin syncing to IMS, click the Sync Now button.

Page 16: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

11

4. When the syncing process has completed it will say “IMS Sync. Finished”. Click the Finish button to complete the sync process.

Page 17: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

11

Chapter 4

Clearing the Handheld If you are changing companies or databases in the IMS server settings, you will need to select Clear handheld from the Utilities Menu.

1. After selecting Clear Handheld, the following warning will appear. Once you select Yes, it will clear all data from the handheld. If you select No, it will stop the process.

2. Once the handheld has been cleared, you will receive the following message. Click OK to complete. After clearing the handheld, you will need to check the company name and re-sync the handheld to IMS by Hurco to obtain that company’s information.

Page 18: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

12

Chapter 5

Maintenance Under Edit on the main menu, you can add or modify devices or tests.

Hydrant Maintenance

Adding a New Hydrant

1. Select Add New. Enter the following information.

a. Hyd ID – This ID will identify the hydrant in the work orders. b. Model Name – The model of the hydrant. c. Manuf Name – Manufacturer of the hydrant. d. Open Dir – Select the direction for opening the hydrant. e. Addr1 & Addr2 – Address of the hydrant f. General Loc – This is the general location of where the hydrant is located on the street.

Page 19: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

13

2. Once all of this information has been entered, click Save Data. 3. Adding GPS Information – If you have a GPS receiver connected, select Start GPS. Once it has

located the information, select Capture GPS. Select Save Data after you have captured your GPS location.

Modifying a Hydrant 1. Change the information that needs to be modified. Once all changes have been entered,

select Save Data.

Valve Maintenance

Adding a New Valve

1. Select Add New. Enter the following information.

a. Valve ID – This ID will identify the valve in the work orders. b. Val Open Dir – This is the direction the valve opens. It will be either left or right. c. Val Pos – This acknowledges whether the valve is open or closed. d. Valve Size. e. Set Rev. f. Set Torque. g. Set Speed. h. Addr1 & Addr2 – Address of the valve. i. General Loc – This is the general location of where the valve is located on the street.

2. Once all of this information has been entered, click Save Data.

Page 20: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

14

3. Adding GPS Information – If you have a GPS receiver connected, select Start GPS. Once it has located the information, select Capture GPS. Select Save Data after you have captured your GPS location.

Modifying a Valve

1. Change the information that needs to be modified. Once all changes have been entered, select Save Data.

Mains Maintenance

Adding a New Main

1. Select Add New. Enter the following information.

a. Main ID – This name will identify the main in the work orders. b. Main Desc – Enter a description of the main. c. Pipe Type – Select the type of pipe that the main is d. Max Size – Enter the maximum diameter of the main. e. Min Size – Enter the minimum diameter of the main. f. Main Length – Enter the length of the main. g. Conn Type – Select the type of connection for the main. h. Install Date – This is the date the main was installed in its location. i. Status – Is the main active or non-active. j. Loc Notes – This is the general location of where the valve is located on the street. k. Select the device types and devices that are located on the main. Then select Add

Device.

2. Once all of this information has been entered, click Save Data.

Page 21: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

15

Modifying a Main

1. Change the information that needs to be modified. Once all changes have been entered, select Save Data.

Fire Flow Test Maintenance

Adding a New Fire Flow Test

1. Select Add New. Enter the following information. a. Enter Test Name b. Enter Test Notes

2. Once this information has been entered, click Save Data.

3. Select Test Hydrant and click Add Hydrant.

4. Select Flow Hydrant and Flow Device. Click Add Hydrant. 5. Once all hydrants have been selected, click Save Data.

Modifying a Fire Flow Test

1. Change the information that needs to be modified. Once all changes have been entered, select Save Data.

Page 22: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

16

C-Factor Test Maintenance

Adding a C-Factor Test

1. Select Add New. Enter the following information. a. Enter Test Name b. Enter Test Notes

2. Once this information has been entered, click Save Data.

3. Select the Test Main and click Add Test Main.

4. Select Flow Hydrant. Click Add Hydrant.

5. Select the Residual Hydrants tab. Select the Residual Hydrant(s) and click Add Hydrant.

6. Select the Isolation Valves tab. Select the Isolation valves and click Add Valve.

Page 23: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

17

7. Once all items have been selected, click Save Data.

Modifying a C-Factor Test

1. Change the information that needs to be modified. Once all changes have been entered, select Save Data.

UDF Test Maintenance

Adding a UDF Test

1. Select Add New. Enter the following information. a. Enter Test Name b. Enter Test Notes

2. Once this information has been entered, click Save Data.

3. Select the Test Main and click Add Test Main.

4. Select Flow Hydrant. Click Add Hydrant.

Page 24: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

18

5. Select the Residual Hydrants tab. Select the Residual Hydrant(s) and click Add Hydrant.

6. Select the Isolation Valves tab. Select the Isolation valves and click Add Valve.

7. Once all items have been selected, click Save Data.

Modifying a C-Factor Test

1. Change the information that needs to be modified. Once all changes have been entered, select Save Data.

Page 25: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

19

Chapter 6

Report Deficiencies

Under Actions on the main menu, you can add deficiencies to hydrants and valves.

Adding a Hydrant Deficiency

To add a deficiency to a hydrant, select Hydrant Deficiency.

1. Select the hydrant that has a deficiency from the dropdown menu.

2. Select the deficiency that was found.

3. Select the priority of the deficiency.

4. Select the required action for the deficiency.

5. Add any notes that are pertinent to the hydrant deficiency.

6. Click Add Deficiency.

Page 26: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

20

7. A confirmation will appear to let you know that the deficiency has been added.

Adding a Valve Deficiency

To add a deficiency to a valve, select Valve Deficiency.

1. Select the valve that has a deficiency from the dropdown menu.

2. Select the deficiency that was found.

3. Select the priority of the deficiency.

4. Select the required action for the deficiency.

5. Add any notes that are pertinent to the valve deficiency.

6. Click Add Deficiency.

7. A confirmation will appear to let you know that the deficiency has been added.

Page 27: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

21

Chapter 7

Conducting a Test From the main screen of the program, you can choose which test you would like to conduct.

Conducting a Fire Flow Test

1. Click the Fire Flow Testing button.

2. Select the work order ID or the Fire Flow Test. Once you have selected the test or work order, click the Next button under the test that you want to conduct.

3. Select the sensor from the drop down menu for each hydrant.

Page 28: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

22

4. If GPS capable, click the GPS Find button. Once the GPS is found, click GPS Lock. If you have GPS information for the hydrants in IMS by Hurco, the program will check this information against your GPS information. The red box next to the hydrant you are closest to will change to green if you are within 50 feet of the hydrant.

5. Once all information has been entered, click the next button. 6. The next screen that will populate will pull the static PSI at your test hydrant. Once the

Sensor status has turned to green, the sensor has a valid PSI reading.

7. Click the Lock Static PSI button. The Sensor Reading Status will change from Reading Static PSI to Static PSI Locked.

Page 29: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

23

8. Click Start Test. Open Flow Hydrants.

9. Once the information has been collected, click Capture Results.

10. Close all flow hydrants. Once flow hydrants are completely closed, click Finish Test.

Page 30: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

24

11. To ensure the most accurate water usage has been collected, the test duration and Total

Gallons Used will continue to run until all Flow Hydrants have been closed and Finish Test has been clicked.

12. After clicking Finish Test, the Test Finish Details screen will appear. a. Select the Test Hydrant from the drop down menu. b. Add any deficiencies that were seen. c. Add any field notes. d. Click Save.

13. When the information has been completed, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a Valve Exercise In Manual Mode

1. Click the Valve Exercising button.

Page 31: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

25

2. Select the Work Order ID or the Exercise Valve Selection. Once you have selected the valve or work order, click the Next button under the test that you want to conduct.

3. Select the following information and click Save. This information comes directly from the valve/hydrant record. a. Open direction. b. Set Revolutions. c. Set Torque. d. Set Speed.

4. Turn the Valve exerciser on. You will need to adjust the torque settings on the valve exerciser in order to get close to the Set Torque. Once the torque is close to the Set Torque number the red circle will turn green.

5. Once this is green, select Start Exercise button.

6. If you select the Start Exercise button, you may get the above error. If this error appears you must go back to the Settings menu and configure your Spin Dr.

Page 32: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

26

7. Once the valve is completely seated in the open position, select the Start button.

8. If a torque log is desired for the test, then select the Start Log button. 9. While the test is in progress, you will see the valve picture change colors as the valve is

opened and closed.

10. When you are finished with the test click Finish. If you need to restart the test for some reason, click restart and you will need to re-click the Start button to move forward with the test.

Page 33: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

27

11. Once the test is finished, you will be taken to the Valve Exercise Finish details screen. a. Add any deficiencies that were seen. b. Add any field notes. c. Click Save.

12. When the information has been completed, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a Valve Exercise In Auto Mode

1. Click the Valve Exercising button.

2. Select the Work Order ID or the Exercise Valve Selection. Once you have selected the valve

or work order, click the Next button under the test that you want to conduct.

3. Select the following information and click Save. This information comes directly from the valve/hydrant record.

Page 34: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

28

a. Open direction. b. Set Revolutions. c. Set Torque. d. Set Speed. e. Set Cycle.

4. Turn the Valve exerciser on with the engine running at about half its full RPM. Make sure the Spin Dr is not connected to the valve wrench at this point (it should be able to free spin).

5. No click on the “Auto-Set Torque/Speed” button and the Spin Dr. Auto will configure its max torque and speed in accordance to what you have in the valve details. NOTE: Torque and Speed can be set manually from this screen as well but Torque MUST be set first when setting this manually.

6. When finished, you will receive a popup telling you that torque and speed were set successfully.

7. Now we are ready to place the Spin Dr. onto the valve. To do this, click the “Valve Jog” button on the lower left side of your screen. This places the Spin Dr. in Jog mode and you can now use the onscreen buttons OR the Mode/Reset buttons on the front of the Spin Dr. to move the wrench back and forth to get it in place on the valve.

8. After you have the Spin Dr. on the valve, close the jog window and click the “Start Exercise” button on the lower right side of your screen.

Page 35: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

29

9. From this screen you have the option to check the “Scrub Mode” check box or the “Start Log” button before you start the test. (Both of these are optional) Scrub Mode – when the valve is seated in the fully closed position during an exercise, the Spin Dr. will slowly open the valve for a few seconds and then stop for a few seconds to allow high pressure water to scrub out the valve seat of any debris that may be present. This (partial open then stop) function runs three times, each opening the valve a bit further before continuing on to complete the cycle of the current exercise. Start Log – is the option to turn on if you would like a full log report on your valve exercise. This option is data intensive and should be used when exercising troubled valves.

10. You are now ready to click the “Start” button on the lower left of your screen. When this button is pressed, the Auto Spin Dr. will first fully open your valve. Once open, it will

automaticly reset the counters and exercise the valve fully closed then fully open for as many cycles as you have set on your “Set Cycle” setting in the valve record.

11. Upon reaching the end of all the set cycles in your current exercise, the Auto Spin Dr. will

spin in the close direction for a few seconds to be sure the valve is not fully seated in the open position.

12. The auto valve exercise is finished at this point and you can now click on the “Finish” button on the lower right of your screen to capture and save the results of this test.

13. When you are finished with the test click Finish. If you need to restart the test for some

reason, click restart and you will need to re-click the Start button to move forward with the test.

Page 36: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

30

14. Once the test is finished, you will be taken to the Valve Exercise Finish details screen. a. Add any deficiencies that were seen. b. Add any field notes. c. Click Save.

15. When the information has been completed, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a Uni-directional Flush

1. Click the Uni-directional Flushing button.

2. Select the Work Order ID or the UDF Test Selection. Once you have selected Flush test or work order, click the Next button under the test that you want to conduct.

Page 37: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

31

3. Select the sensor color for each hydrant of the test.

4. If GPS capable, click the GPS Find button. Once the GPS is found, click GPS Lock. If you have GPS information for the hydrants in IMS by Hurco, the program will check this information against your GPS information. The red box next to the hydrant you are closest to will change to green if you are within 50 feet of the hydrant.

5. Click the Next button once all hydrants have sensors.

6. The next screen that will populate will pull in static PSI at you test hydrant. Once the Sensor status has turned to green, the sensor has a valid PSI reading.

Page 38: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

32

7. Click the Lock Static PSI button. The Sensor Reading Status will change from Reading Static PSI to Static PSI Locked.

8. Click Start Test. Open Flow Hydrant(s).

9. Once the information has been collected, click Capture Results.

10. Close all flow hydrants. Once flow hydrants are completely closed, click Finish Test.

11. To ensure the most accurate water usage has been collected, the test duration and Total Gallons Used will continue to run until all Flow Hydrants have been closed and Finish Test has been clicked.

Page 39: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

33

14. After clicking Finish Test, the Test Finish Details screen will appear. a. Select the Start Clarity. b. Select the During Clarity. c. Select the Final Clarity. d. Add any Field Notes. e. Click Save.

15. When the information has been completed, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a C-Factor Test

1. Click the C-Factor Testing button.

2. Select the Work Order ID or the C-Factor Test Selection. Once you have selected C-Factor Test or work order, click the Next button under the test that you want to conduct.

Page 40: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

34

3. Select the sensor color for each hydrant of the test.

4. If GPS capable, click the GPS Find button. Once the GPS is found, click GPS Lock. If you have GPS information for the hydrants in IMS by Hurco, the program will check this information against your GPS information. The red box next to the hydrant you are closest to will change to green if you are within 50 feet of the hydrant.

5. Click the Next button once all hydrants have sensors.

6. The next screen that will populate will pull in static PSI at you test hydrant. Once the Sensor status has turned to green, the sensor has a valid PSI reading.

Page 41: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

35

7. Click the Lock Static PSI button. The Sensor Reading Status will change from Reading Static PSI to Static PSI Locked.

8. Click Start Test. Open Hydrant(s).

9. Once the information has been collected, click Capture Results.

10. Close all hydrants. Once hydrants are completely closed, click Finish Test.

11. To ensure the most accurate water usage has been collected, the test duration and Total Gallons Used will continue to run until all Hydrants have been closed and Finish Test has been clicked.

Page 42: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

36

12. After clicking Finish Test, the Test Finish Details screen will appear. a. Select the Start Clarity. b. Select the During Clarity. c. Select the Final Clarity. d. Add any Field Notes. e. Click Save.

13. When the information has been completed, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a Hydrant Flush

1. Click the Hydrant Flush button.

2. Select the Work Order ID or the Hydrant. Once you have selected hydrant or work order, click the Next button under the test that you want to conduct.

Page 43: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

37

3. Select the sensor color for the hydrant that is being flushed and click “Next”.

4. The flush begins as soon as the screen loads and you can now start flushing your hydrant. When finished flushing, click on “Capture Results”, this will insure all your flushing activity is saved.

5. When the information has been captured, click Finish. This will take you back to the main

screen to complete any further testing.

Conducting a Repair or Maintenance

1. Click the Repair and Maintenance button.

Page 44: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

38

2. Select the work order that needs to be completed. Then select Next.

3. Add the field notes to the work order you have selected. Once the work order has been completed, check the box next to Mark Completed. Then click Save Data.

4. The work order has been fulfilled.

Page 45: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

39

Chapter 8

Results You can view the test results by selecting the test you want to view under Results on the Main Menu. The test results cannot be modified in these screens.

Exercise Results

To view results of Valve exercises completed, select Exercise Results.

Fire Flow Results

To view results of Fire Flow Test completed, select Fire Flow Results. You may need to use the scroll bar to view all of the details for the test.

Page 46: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

40

C-Factor Results

To view results of C-Factor Test completed, select C-Factor Results. You may need to use the scroll bar to view all of the details for the test.

UDF Results

To view results of UDF Test completed, select UDF Results. You may need to use the scroll bar to view all of the details for the test.

Page 47: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

41

Hydrant Stickers

Once a Fire Flow test has been run, you have the option to print a sticker to apply to the hydrant to show the test results.

1. Select the Fire Flow test for the sticker and press Next.

2. The sticker will appear to be printed. Once printed, you will need to affix the correct color reflective strip for the NFPA rating in the appropriate box.

Page 48: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

42

Chapter 9

Help Here is where you can find the help documentation and information about IMS Mobile.

About

This screen gives the information about IMS Mobile. It gives the current version that may be required when calling for technical assistance.

Page 49: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

43

Help Doc

This option gives you this file in a readable PDF format.

IMS Mobile Video User Guide

This takes you to the internet to view helpful videos in regards to IMS Mobile and the test process. You can view various videos to assist you with understanding and running tests available on IMS Mobile.

Page 50: REFERENCE MANUAL - Jim Cox Salesjimcoxsales.com/.../08/Reference-Manual-IMS-Mobile.pdf · IMS server setting is the path and credentials for your IMS by Hurco database. This database

1-800-888-1436 • gethurco.com •

Rev: 07-30-2012Part No. IMS MOBILE-OM

[email protected]