reduced cost subsea condition monitoring using ‘send and forget’ acoustic communication

41
Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication Andy Smerdon CEO Aquatec Group, UK Wednesday Session Track 1 14 December 2011

Upload: aquatecgroup

Post on 22-Jan-2015

476 views

Category:

Technology


2 download

DESCRIPTION

Presentation given at the Subsea Survey IRM conference 2011 in Houston, describing applications of Aquatec's AQUAmodem 500 'send and forget' underwater communication system.

TRANSCRIPT

Page 1: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Andy SmerdonCEO Aquatec Group, UK

Wednesday Session

Track 1

14 December 2011

Page 2: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case studies• Summary

14 December 2011

Slide 2

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 3: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case studies• Summary

14 December 2011

Slide 3

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 4: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Aquatec Group Ltd

14 December 2011

Slide 4

• Founded in 1990 by Andy Smerdon• Based in UK, 40 miles SW of London• Primary expertise:

• Subsea instrumentation• Underwater acoustics• Low power autonomous systems

• Design and manufacture all products and engineered solutions

• Products sold worldwide

Page 5: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Aquatec Group Ltd

14 December 2011

Slide 5

Customers in the offshore market

Page 6: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case studies• Summary

14 December 2011

Slide 6

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 7: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Acoustic Telemetry: Pros & ConsPros Cons

Long range potential Slow Cheaper than long

cable runs Needs power: even

more for 2-way Cheaper to install

than cable Busy communication

channel Can be more robust

than cable Acoustic path can

be problematic

14 December 2011

Slide 7

Page 8: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

‘Send and Forget’ concept• System Analogies

1. Static meter display - check when passing or on a schedule

2. Heartbeat monitor- periodic tick shows system is healthy- alarm and increased data when faulty

• Measure data at preset rate• Transmit data infrequently if all is well• Increase update rate when alarm conditions are met• Transmission is automatic – no interrogation needed

from the surface• Only powered up when reading data or transmitting

14 December 2011

Slide 8

Page 9: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case studies• Summary

14 December 2011

Slide 9

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 10: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

1st AQUAmodem 500 System• Manufacturer of marine

hoses for offloading– Double carcass– Outer carcass unstressed– Has same rating as inner

hose to contain leak• Needed warning system

– Need to know leak hasoccurred

– Diver operated tap onone-way valve

14 December 2011

Slide 10

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 11: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Slide 11

Concept Development• 1990’s Aquatec underwater comms:

Cathodic protection monitoring with acoustic-linked dataacquisition units Data rates up to 1kbps Long deployment timeHigh power requirementLarge housingsExpensive to build

14 December 2011

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 12: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

14 December 2011

Slide 12

Subsea Survey IRM, Houston Send & Forget Telemetry

Concept Development• Previous Aquatec acoustic

products:AQUAmark marine mammaldeterrent Very low power Long deployment time Semi-random transmission Low cost

Page 13: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Slide 13

Concept Development• Previous Aquatec data acquisition

products:AQUAlogger 520pressure/temperaturedata loggers Very low power Long deployment time Precision measurement Low cost

14 December 2011Subsea Survey IRM, Houston

Send & Forget Telemetry

Page 14: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Slide 14

Concept Development• Combined the AQUAlogger &

AQUAmark to produce theAQUAmodem 500P Low power telemetry Low power pressure

measurement Long deployment time Small size Semi-random

transmissions

14 December 2011Subsea Survey IRM, Houston

Send & Forget Telemetry

Page 15: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Mode of Use• Pressure telemetry

system– Replace tap with

subsea pressure telemetryunit

– Integral pressuretransducer

– Measures pressure and transmits as acoustic signal

– Signal received and decoded at surface

14 December 2011

Slide 15

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 16: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Mode of Use

14 December 2011

Slide 16

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 17: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

AQUAmodem 500P Acoustics• ‘Send and forget’ principle• Read every 5 minutes• Transmit every 30 minutes unless alarm condition is

detected• Transmit every 5 minutes if alarm is detected• Message collision avoidance:

– Two transmissions every update period– Separated by random interval

• Message includes error checking and correction• Decoding includes multiple validation stages to

minimise false alarms• Range up to 400 m14 December 2011

Slide 17

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 18: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Schematic

14 December 2011

Slide 18

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 19: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Surface & Software Schematic

14 December 2011

Slide 19

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 20: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case study 1• Summary

14 December 2011

Slide 20

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 21: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 1: Karan Temperature• Karan jacket

– Gas production platform– Offshore Saudi Arabia– Seabed (pipeline) temperature used in pipeline

gas leak detection system calculations– Avoidance of cable use provided simpler and

less expensive solution for customer• Specification

– Monitor temperature at bed (-50m LAT) to ±0.1°C

– Transfer to DCS as 4-20 mA signal

14 December 2011

Slide 21

Page 22: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

• Karan gas platform• Offshore Saudi Arabia• Sea bed temperature

monitoring requiredfor pipeline gas leakdetection system

Case Study 1: Seabed Temperature

14 December 2011

Slide 22

Page 23: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 1: Seabed Temperature• Temperature

measurement of waternear mud line

• Transmission of data tosurface for relay toplatform computersystem

14 December 2011

Slide 23

Page 24: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 1: Seabed Temperature

14 December 2011

Slide 24

• Measurement is transmitted from acquisition system clamped to 24” member every 10 minutes.

• Receiver is mounted on flanged I-tube then cabled to DCS as 4-20 mA signal

Page 25: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case study 2• Summary

14 December 2011

Slide 25

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 26: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 2: Pipeline Temperature• Asian subsea installation

– Retrofit heated pipe in pipe– 50 to 60m water

14 December 2011

Slide 26

Page 27: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 2: Pipeline Temperature• Semi-remote temperature feedback required to

– Maintain flow assurance– Calibrate field production operations

• 8” and 4” pipes to be monitored

14 December 2011

Slide 27

Page 28: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 2: Pipeline Temperature

4” temperature monitor & surface receiver

14 December 2011

Slide 28

Page 29: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 2: Pipeline Temperature• Temperature sensor in

base of instrument• Insulation layer to allow

pipe temperature to be measured

• Custom saddle for each pipe

• Saddle strapped on to pipe

• Transmits every 5 mins

14 December 2011

Slide 29

Page 30: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry14 December 2011

Slide 30

Page 31: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry14 December 2011

Slide 31

Page 32: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

14 December 2011

Slide 32

Page 33: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case study 3• Summary

14 December 2011

Slide 33

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 34: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 3: CP Monitoring• UK North Sea platform• 25 years old• New impressed current

cathodic protectionsystem installed

• Require near real-timecathodic protectionpotentials for closedloop control

14 December 2011

Slide 34

Page 35: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 3: CP Monitoring

14 December 2011

Slide 35

CP5

CP6

CP3 CP4

CP2CP1

CP9CP8

CP7

Cathodic Protection PSU

& Control Software

Anode Sleds

Hydrophone

Page 36: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Case Study 3: CP Monitoring• 9 AQUAmodem 500CP

modules• Steel case in contact with

jacket through clamparrangement

• Monitor jacket potential withrespect to Zinc electrode &Silver/Silver Chloride cell

• Transmit data every 15 mins

14 December 2011

Slide 36

Page 37: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Other Applications• Leak detection• Hydrotest monitoring• Level or attitude sensors• Intelligent pig pingers• …

14 December 2011

Slide 37

Page 38: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Overview• Introduction to Aquatec Group• Acoustic telemetry

– pros and cons– ‘Send and forget’ concept

• AQUAmodem 500 system• Case studies• Summary

14 December 2011

Slide 38

Subsea Survey IRM, Houston Send & Forget Telemetry

Page 39: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Present Limitations• Range versus Power

– Smallest instruments 400m– Maximum range 3-4 km with appropriate power

• Acoustic Path– Cannot bend the laws of physics, or acoustic rays

• Data– Typically 1 or 2 values measured and transmitted

• Number of Units– 64 maximum

• Update Rate– Aim for not more than one unit per 20s

14 December 2011

Slide 39

Page 40: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

Summary• Measurement and transmission

integrated into one unit• Low power, long life• Multi-point data acquisition• Removes need for unreliable or costly

cabling• Cheaper and more efficient than

general purpose acoustic modems

14 December 2011

Slide 40

Page 41: Reduced cost subsea condition monitoring using ‘Send and Forget’ acoustic communication

Subsea Survey IRM, Houston Send & Forget Telemetry

14 December 2011

Slide 41Slide 41

Thank you.Any questions?

Andy Smerdon: [email protected] www.aquatecgroup.com

Manufacturers of:Hydrotest Instrumentation - Temperature and Pressure Data Loggers

Leak Detection Systems – Vibration Monitoring InstrumentsCathodic Protection and Monitoring Systems

Acoustic and Optical Suspended Sediment Profilers and InstrumentsUnderwater Acoustic Data Telemetry