reclaimed water system details
TRANSCRIPT
City of Orlando Wastewater Division
Reclaimed Water System Design and Construction Specifications
Index of Sheets
Sheet No. Title /Description
RGN-1 Reclaimed – General Notes RGN-2 Reclaimed – General Notes (Cont’d) RGN-3 Reclaimed – General Notes (Cont’d) RGN-4 Reclaimed – General Notes (Cont’d) RGN-5 Reclaimed – General Notes (Cont’d) R-01 Sign Post Installation R-02 Typical Residential Utility Layout – Single Service Connections R-03 Residential Service Connections R-04 Commercial Above Ground 2” Reclaim Water Meter Installation Detail R-05 Commercial Service Connection – Above Grade – 3” And Larger R-05A Commercial Service Connection – Above Grade – 2” Or Smaller R-06 General Slab Design & Bollards R-07 Pipe Supports R-08 Pressure Gage Installation R-09 Trenching with Type A Bedding R-10 Trenching with Type B Bedding R-1 1 Trenching in Paved Areas R-12 Concrete Pipe Encasement R-13 Casing Pipe Spacers R-14 Casing Pipe R-15 Horizontal Separation Requirements (F.A.C. Rule 62-555.314) R-16 Vertical Separation Requirements R-17 Crossings or Obstructions R-18 Utility Conflicts R-19 Air Release Valve Installation – Above Grade R-20 Combination Air and Vacuum Release Valve – Below Grade R-21 Buried Valve Box Setting R-22 Valve Box Collar R-23 Detector Ball Location Detail R-24 Pipe Identification R-25 Pipe Warning Tape R-26 Restrained Ductile Iron Joints R-27 3” - 24” Standard Tapping Assembly R-28 Dead End Blow-Off Valve Installation R-29 Temporary Blow-Off Installation R-30A Silt Fence R-30B Curb and Gutter Sediment Barrier R-30C Silt Fence Drop Inlet Sediment Barrier R-30D Curb Inlet Sediment Barrier R-30E Attaching Two Silt Fences / Proper Placement of Straw Bale Barrier in Drainage Way R-30F Straw Bale Barrier R-30G Drop Inlet Sediment Barriers R-30H Filter Fabric Drop Inlet Sediment Filter R-NEW Non-Commercial Reclaim Water Meter Installation Detail for 2”
COMMERCIAL ABOVE GROUNDRECLAIM WATER METER
INSTALLATION DETAIL FOR 2"
Fig 264: Loads (lbs) * Weight (lbs) * Dimensions (in)
Pipe Size
2.533.5456810121416182024303236
9.2
40.2
249.0181.0170.0137.0104.870.853.2
29.025.220.217.716.715.09.4
9.05.0
38.0
229.0161.1150.0110.085.051.042.0
21.617.812.810.38.37.65.2
4.82.5
3
4
6
AComplete Saddle Only
WeightD
1.5
2.5
3
4
3.5
BE
Min MaxWidth C
4.625
6.75
8.75
3.625
33.75
10.9375
24.522.521.312517.937515.37513.87512.375
9.93758.56.8755.58.8754.254
3.5
16.2517.7519.52123.752728.2530.25
9.258.58.25
1010.511.7513.515
8
20.7522.252425.528.2531.532.7534.75
1413.513.25
14.7515.2516.518.2519.75
13
* The special cast iron reducer may be furnished with a hexed shaped smaller end.
CONSULT MANUFACTURER FOR RESTRAINED LENGTHS FOR PVC PIPE.