reception scheme
TRANSCRIPT
A design and build proposal
for
Reception refurbishment
14-4-15
interior concepts
Reception, visualisation
Orion Business Park
New high quality meeting space to support new customer sales.
Existing suspended ceiling line
New suspended ceiling rafts with green halo led
New led pendant fitting
Vertical cladding panel over existing fire and AC controls in
high gloss laminate
ROSPA display wall, Single framed certificate of latest award
with previous years as applied dates
New wall panel with vinyl/foam core cut signage
Existing door panel painted in eggshell grey
Walls decorated in white vinyl matt paint
Bespoke counter
New vinyl flooring
New entrance matting
interior concepts
Reception, visualisation
Orion Business Park
New high quality meeting space to support new customer sales.
Feature inset in new vinyl flooring, runs in line with wall
cladding
New visitor seating. Single chairs to increase feeling of space.
Single chair upholstered in on brand fabric colour.
New carpet tiles to door line of meeting rooms
interior concepts
Reception, visualisation
Orion Business Park
New high quality meeting space to support new customer sales.
Bespoke art work to create super graphic vinyl printed wall
covering
Power and data connections to desk chased into concrete
screed from existing location on rear wall. Lidded floor box
set flush into floor under desk.
New Task chair in brand colours
interior concepts
Reception, general arrangement
Orion Business Park
New high quality meeting space to support new customer sales.
Simple wall cladding panel displaying framed ROSPA certificate and all
associated dates in vinyl lettering. Descriptor panel about H&S awards with logo
at entry to meeting rooms. Extra space for additional awards.
Existing doors painted in Grey Dulux 10GY 41/600 eggshell. Frames and
architraves in white eggshell.
Existing vinyl flooring replaced with new Amtico spacia tiles in white and grey.
Ref: softline pebble and charcoal.
Existing entrance matting replaced with new Gradus matwell in framed
aluminium and black.
Existing suspended ceiling retained. New floating acoustic rafts suspended
below ceiling line with green led lighting to create halo edge effect. New
aluminium extruded pendant fitting, with led direct and indirect white lighting
suspended above reception desk.
New bespoke reception counter finished in two tone laminate. Formica ref:
Storm F7912 (matt); Crystal F3091; (matt). Power and data fed from wall and
chased into lidded cable tray in concrete screed.
New vertical cladding to box in existing AC controls and Fire panel. Grey tinted
glass access door to fire panel. High gloss laminate finish to cladding, Formica
Storm F7912 (gloss). New wall panel to either side with applied fret cut acrylic
lettering forming client logo.
New simple wall panel with large super graphic applied to face.
New Odyssey soft seating in mixed leather and fabric. Feature green fabric to be
Kvadrat messenger 4 ref:008. Grey leather to be Andrew Muirhead or similar.
Existing door and frames retained.
interior concepts
Reception, brand application
Orion Business Park
Reception counter
Existing suspended ceiling line
New suspended ceiling rafts
New led pendant fitting
Vertical cladding panel over existing controls
New wall panel with vinyl/foam core cut signage
Existing door panel painted in eggshell grey
Walls decorated in white vinyl matt paint
Existing skirting re-painted in white eggshell
Reception rear wall elevation
High section to screen technology on the desk
Sign in shelf for visitors
Desk size section increased to provide greater work space
3005
880
2005
300
10501100
815
585
740
A
A
pedestal byfurniture supplier
10
415
GENERAL NOTES:
MDF construction clad in laminate;Main desk & upstand/visitor shelf inFormica Crystal White F3091 Matte.Privacy Wrap in Formica StormF7912 Matte.
Brushed aluminium cable ports.
740
815
300
195
10501100
30
10
cable port
cable management
100
© TSK group Ltd, 2014. All rights reserved.
The information contained within this media is and shall at all times remain the
property of TSK group Ltd (TSK). It is provided to you only for those purposes
which are specified by TSK on or before the time of disclosure and for no other
purposes whatsoever. Unless TSK specifically agrees otherwise in writing, you
are EXPRESSLY PROHIBITED from (i) using the information for purposes other than
those agreed in advance by TSK, (ii) copying, photocopying or otherwise
reproducing this information; (iii) amending, altering or changing the
information; and (iv) distributing or transmitting it to any other person or entity, in
each case whether in whole or in part and in whatever media. The information
contained within this media is for guidance only. Whilst TSK uses its reasonable
endeavours to provide accurate information it gives no warranty or guarantee
of such and hereby expressly excludes all express and implied warranties and
all liability in respect thereof. Furthermore, TSK accepts no responsibility for the
accuracy of any information provided by third parties.
Unit B - Reception Desk
CDM 2015 - RESIDUAL RISKDesign Feature : Joinery
Hazard: manual handlingHazard: risk from cutting, sanding &
drilling MDF, hardwoods & softwoods
for c
onst
ruct
ion
The TSK Group LtdE : [email protected] : www.tskgroup.co.uk
no dimensions to be scaled from this drawing unless otherwise stated.all dimensions to be checked on site.
drawing no.
critical design control points :check 1 check 2 check 3
drawing title
original issue date
drawn by
location
brief
client
revision description
scale sheet size
checked by
chec
ked
by
dra
wn
byd
ate
revision
proj
ect s
tatu
s
brief & survey established client design freeze / output verification as built / design validation
project manager
building surveyed by TSK by date
Draw
ing
Stat
us ManchesterM50 2UWT : +44(0)161 872 0298
LondonEC2V 6JPT : +44(0)20 7489 7656
joinery drawing of reception desk
Landis & GyrOrion Business Park
Stockport
OJ TW S. Langshaw
1:20 A2 13-05-15
Unit BGround Floor
Reception Desk Detail
150103 FG0-JN01
. PSC
.Approved By..................................... Date........................Approved By..................................... Date........................Approved By..................................... Date........................
KITCHENFWCWC
A
eqeq
50
1500
eqeq
+ 2690
+ 2560A
+ 2560A
25602690
eq eq
eq eq
LED Strip Lighting above ceiling raft
© TSK group Ltd, 2015. All rights reserved.
The information contained within this media is and shall at all times remain the
property of TSK group Ltd (TSK). It is provided to you only for those purposes
which are specified by TSK on or before the time of disclosure and for no other
purposes whatsoever. Unless TSK specifically agrees otherwise in writing, you
are EXPRESSLY PROHIBITED from (i) using the information for purposes other than
those agreed in advance by TSK, (ii) copying, photocopying or otherwise
reproducing this information; (iii) amending, altering or changing the
information; and (iv) distributing or transmitting it to any other person or entity, in
each case whether in whole or in part and in whatever media. The information
contained within this media is for guidance only. Whilst TSK uses its reasonable
endeavours to provide accurate information it gives no warranty or guarantee
of such and hereby expressly excludes all express and implied warranties and
all liability in respect thereof. Furthermore, TSK accepts no responsibility for the
accuracy of any information provided by third parties.
CDM 2015 - RESIDUAL RISKDesign Feature : Lighting
Hazard: contact with live servicesHazard: falls from height
The TSK Group LtdE : [email protected] : www.tskgroup.co.uk
no dimensions to be scaled from this drawing unless otherwise stated.all dimensions to be checked on site.
drawing no.
critical design control points :check 1 check 2 check 3
drawing title
original issue date
drawn by
location
brief
client
revision description
scale sheet size
checked by
chec
ked
by
dra
wn
byd
ate
revision
proj
ect s
tatu
s
brief & survey established client design freeze / output verification as built / design validation
for a
ppro
val
project manager
building surveyed by TSK by date
Dra
win
g St
atus Manchester
M50 2UWT : +44(0)161 872 0298
LondonEC2V 6JPT : +44(0)20 7489 7656
Produce Ceiling Raft Layout
Landis & GyrOrion Business Park
Stockport
LH MBR S Langshaw
1:50 A3 14-05-15
Unit B - ReceptionGround Floor
Ceiling Raft Layout
150103 FG0-AR05
. P.S.C 11.05.15
.Approved By..................................... Date........................Approved By..................................... Date........................Approved By..................................... Date........................
ELEVATION A
A - Ecophon Solo Rectangle Panel (orsimilar) 2400 x 1200
KITCHENFWCWC
℄
Laid brick pattern
Matwell
Amtico Spacia tile
Satin Anodised Matwell frame
Satin AnodisedThreshold trim
Existing floor finish
© TSK group Ltd, 2015. All rights reserved.
The information contained within this media is and shall at all times remain the
property of TSK group Ltd (TSK). It is provided to you only for those purposes
which are specified by TSK on or before the time of disclosure and for no other
purposes whatsoever. Unless TSK specifically agrees otherwise in writing, you
are EXPRESSLY PROHIBITED from (i) using the information for purposes other than
those agreed in advance by TSK, (ii) copying, photocopying or otherwise
reproducing this information; (iii) amending, altering or changing the
information; and (iv) distributing or transmitting it to any other person or entity, in
each case whether in whole or in part and in whatever media. The information
contained within this media is for guidance only. Whilst TSK uses its reasonable
endeavours to provide accurate information it gives no warranty or guarantee
of such and hereby expressly excludes all express and implied warranties and
all liability in respect thereof. Furthermore, TSK accepts no responsibility for the
accuracy of any information provided by third parties.
FLOORING NOTES
Flooring installation to comply withBS8203: 2001
Floor tiling to comply withBS8000-11.2: 1990
All flooring to comply withmanufacturers specifications asstated in manufacturers literature
All seams on vinyl flooring to be heatwelded
Adhesives to be approved bymanufacturer
FLOORING KEY
Manufacturer: AmticoRange: SpaciaReference: SS5A3802Colour: Softline Pebble (cream/l.grey)Size:457.2 x 457.2mmThickness: 2.5mm (with 0.55mm wear layer)Quantity: 21.8 m2
The TSK Group LtdE : [email protected] : www.tskgroup.co.uk
no dimensions to be scaled from this drawing unless otherwise stated.all dimensions to be checked on site.
drawing no.
critical design control points :check 1 check 2 check 3
drawing title
original issue date
drawn by
location
brief
client
revision description
scale sheet size
checked by
chec
ked
by
dra
wn
byd
ate
revision
proj
ect s
tatu
s
brief & survey established client design freeze / output verification as built / design validation
for a
ppro
val
project manager
building surveyed by TSK by date
Dra
win
g St
atus Manchester
M50 2UWT : +44(0)161 872 0298
LondonEC2V 6JPT : +44(0)20 7489 7656
flooring detail drawing.
Landis & GyrOrion Business Park
Stockport
LH MBR S Langshaw
1:50 A3 14-05-15
Unit B - ReceptionGround Floor
Flooring Layout
150103 FG0-FS01
. P.S.C 11.05.15
.
CDM 2015 - RESIDUAL RISKDesign Feature : Flooring Installation
Hazard: manual handlingHazard: exposure to harmful &
flammable adhesivesHazard: risk of cuts during installation
note: All Quantities to be checked byflooring contractor, no allowance forcuts / waste are in m2 quantities above
Manufacturer: AmticoRange: SpaciaReference: SS5A2803Colour: Softline Charcoal (d.grey/black)Size: 457.2 x 457.2mmThickness: 2.5mm (with 0.55mm wear layer)Quantity: 3.4 m2
Manufacturer: TBCRange: Entrance Matting TBCReference: TBCColour: Black with MetalSize: TBCThickness: TBCQuantity: 6.7 m2
Note: All flooring to level finish
Approved By..................................... Date........................Approved By..................................... Date........................Approved By..................................... Date........................
KITCHENFWCWC
1575
eqeq
A
eq eq
eq eq
2690
2250
200
© TSK group Ltd, 2015. All rights reserved.
The information contained within this media is and shall at all times remain the
property of TSK group Ltd (TSK). It is provided to you only for those purposes
which are specified by TSK on or before the time of disclosure and for no other
purposes whatsoever. Unless TSK specifically agrees otherwise in writing, you
are EXPRESSLY PROHIBITED from (i) using the information for purposes other than
those agreed in advance by TSK, (ii) copying, photocopying or otherwise
reproducing this information; (iii) amending, altering or changing the
information; and (iv) distributing or transmitting it to any other person or entity, in
each case whether in whole or in part and in whatever media. The information
contained within this media is for guidance only. Whilst TSK uses its reasonable
endeavours to provide accurate information it gives no warranty or guarantee
of such and hereby expressly excludes all express and implied warranties and
all liability in respect thereof. Furthermore, TSK accepts no responsibility for the
accuracy of any information provided by third parties.
LIGHTING NOTES
To comply with:BS EN60598-1:2004Building Regulations 2006 Part B2Building Regulations 2010 Part LBS EN 1838:1999, BS 526607:1999Health & Safety (Display Screen Equipment) Regulations 1992and accompanying Guidance Notes.Workplace (Health, Safety and Welfare) Regulations 1992.CIBSE Code for Lighting 2009.Emergency lighting to comply with BS 5266-1:2005.
CDM 2015 - RESIDUAL RISKDesign Feature : Lighting
Hazard: contact with live servicesHazard: falls from height
The TSK Group LtdE : [email protected] : www.tskgroup.co.uk
no dimensions to be scaled from this drawing unless otherwise stated.all dimensions to be checked on site.
drawing no.
critical design control points :check 1 check 2 check 3
drawing title
original issue date
drawn by
location
brief
client
revision description
scale sheet size
checked by
chec
ked
by
dra
wn
byd
ate
revision
proj
ect s
tatu
s
brief & survey established client design freeze / output verification as built / design validation
for a
ppro
val
project manager
building surveyed by TSK by date
Dra
win
g St
atus Manchester
M50 2UWT : +44(0)161 872 0298
LondonEC2V 6JPT : +44(0)20 7489 7656
Produce Lighting Layout
Landis & GyrOrion Business Park
Stockport
LH MBR S Langshaw
1:50 A3 14-05-15
Unit B - ReceptionGround Floor
Lighting Layout
150103 FG0-EL01
. P.S.C 11.05.15
.Approved By..................................... Date........................Approved By..................................... Date........................Approved By..................................... Date........................
Reception Area Linear Lighting Optelma (or similar)M2M Axis-Y colour TBCSize 3000 x 200
ELEVATION A
New Spotlights
Existing 600 x 600 recessed luminaire(E = with emergency pack; X = existing to beremoved;
X
X
KITCHENFWCWC
A
h-TBC
15001400
1000
Existing boxing out around column
to be extended, patressedand boarded to support AV screen
1900
TBC
1400
TBC
© TSK group Ltd, 2015. All rights reserved.
The information contained within this media is and shall at all times remain the
property of TSK group Ltd (TSK). It is provided to you only for those purposes
which are specified by TSK on or before the time of disclosure and for no other
purposes whatsoever. Unless TSK specifically agrees otherwise in writing, you
are EXPRESSLY PROHIBITED from (i) using the information for purposes other than
those agreed in advance by TSK, (ii) copying, photocopying or otherwise
reproducing this information; (iii) amending, altering or changing the
information; and (iv) distributing or transmitting it to any other person or entity, in
each case whether in whole or in part and in whatever media. The information
contained within this media is for guidance only. Whilst TSK uses its reasonable
endeavours to provide accurate information it gives no warranty or guarantee
of such and hereby expressly excludes all express and implied warranties and
all liability in respect thereof. Furthermore, TSK accepts no responsibility for the
accuracy of any information provided by third parties.
ELECTRICAL SERVICES NOTES
Installation to comply with current BS7671 IEEWiring Regulations
CDM 2015 - RESIDUAL RISKDesign Feature : Electrical SystemsHazard: contact with live services
Hazard: fall from heightsHazard: trips and falls
The TSK Group LtdE : [email protected] : www.tskgroup.co.uk
no dimensions to be scaled from this drawing unless otherwise stated.all dimensions to be checked on site.
drawing no.
critical design control points :check 1 check 2 check 3
drawing title
original issue date
drawn by
location
brief
client
revision description
scale sheet size
checked by
chec
ked
by
dra
wn
byd
ate
revision
proj
ect s
tatu
s
brief & survey established client design freeze / output verification as built / design validation
for a
ppro
val
project manager
building surveyed by TSK by date
Dra
win
g St
atus Manchester
M50 2UWT : +44(0)161 872 0298
LondonEC2V 6JPT : +44(0)20 7489 7656
Produce Small Power Layout
Landis & GyrOrion Business Park
Stockport
LH MBR S Langshaw
1:50 A3 14-05-15
Unit B - ReceptionGround FloorSmall Power
150103 FG0-EL02
. P.S.C 11.05.15
.
KEY
Double switched socket outlet
Double RJ45 data outlet
Floorbox - Contents tbc
Approved By..................................... Date........................Approved By..................................... Date........................Approved By..................................... Date........................
ELEVATION A
Aerial - tbc