realpresence medialign slimline base wall bracket assembly ... · floor level (ffl) dimensions in...

5
IMPORTANT SAFETY NOTICE Before beginning the installation process, it is important to check that the designated area is suitable for the system. If you have any doubts, contact your retailer / supplier who can answer any questions. This installation guide explains the procedure for installing this product. Please read this guide carefully to ensure thorough understanding of the details of this product before installation. Some items are fragile or heavy and require a minimum of two persons for certain tasks. Ensure that suitable help is provided. Do NOT attempt to move equipment alone or unsupervised. Ensure that all personal protective equipment required for installation is used and operation instructions are followed. Ensure that the system is level before securing to the wall brackets. A number of adjustable feet are located on each base section which can be individually adjusted to ensure that the system is level to the floor. The number of feet will differ between product models. FRAGILE HEAVY Ensure that the wall partition(s) is suitably secure to support the brackets and that all materials are suitable prior to starting the installation process. Polycom® RealPresence® Medialign TM Slimline Base Wall Bracket ASSEMBLY INSTRUCTIONS 1 1725-84209-001

Upload: others

Post on 21-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RealPresence Medialign Slimline Base Wall Bracket Assembly ... · FLOOR LEVEL (FFL) DIMENSIONS IN MM DIMENSIONS IN MM Anchor Locations - RealPresence Medialign 170 Anchor Locations

IMPORTANT SAFETYNOTICE

Before beginning the installation process, it is important to check that the designated area is suitable for the system. If you have any doubts, contact your retailer / supplier who can answer any questions.

This installation guide explains the procedure for installing this product. Please read this guide carefully to ensure thorough understanding of the details of this product before installation.

Some items are fragile or heavy and require a minimum of two persons for certain tasks. Ensure that suitable help is provided. Do NOT attempt to move equipment alone or unsupervised.

Ensure that all personal protective equipment required for installation is used and operation instructions are followed.

Ensure that the system is level before securing to the wall brackets. A number of adjustable feet are located on each base section which can be individually adjusted to ensure that the system is level to the floor. The number of feet will differ between product models.

FRAGILE HEAVY

Ensure that the wall partition(s) is suitably secure to support the brackets and that all materials are suitable prior to starting the installation process.

Polycom® RealPresence® MedialignTM Slimline Base Wall Bracket

ASSEMBLY INSTRUCTIONS

11725-84209-001

Page 2: RealPresence Medialign Slimline Base Wall Bracket Assembly ... · FLOOR LEVEL (FFL) DIMENSIONS IN MM DIMENSIONS IN MM Anchor Locations - RealPresence Medialign 170 Anchor Locations

2

Wall anchors and fasteners are not supplied with the wall bracket kit and will need to be locally sourced. You must use fasteners appropriate for your specific wall structure to ensure that the brackets may be securely anchored.

5

The wall bracket kit consists of a pair of wall plates (a), four thumb screws (b), eight chrome caps (c), and two brackets (d).

b

b

d

a

1

The wall bracket kit is supplied with any Medialign system fitted with a slimline base. The slim format reduces the footprint of the system maximising office space.

RealPresence Medialign 155/255Slimline Base

RealPresence Medialign 170/270Slimline Base

2

The wall bracket kit is designed to prevent any of the Medialign solutions fitted with slimline bases from toppling over. The wall brackets are NOT designed to support heavy objects and are NOT load bearing.

3

It is beneficial to install the wall bracket kit BEFORE the screen solution is completely assembled. The wall bracket kit is referred to in all assembly instructions.

4

R

R

PSU

x2

CODECx2

RPG500 BRACKET

PSU BRACKET

x2

PSU

x2

x2

3

8

11

9

A S H T O N B E N T L E Y

TM

TM

x2

10

x2

Refer to the anchor location drawings at the end of this document. Using the dimensions supplied for your specific system, carefully position a wall plate on the wall ensuring that it is level. Use a pencil to mark all four fastener holes for the plate. Repeat for the second plate.

6

Page 3: RealPresence Medialign Slimline Base Wall Bracket Assembly ... · FLOOR LEVEL (FFL) DIMENSIONS IN MM DIMENSIONS IN MM Anchor Locations - RealPresence Medialign 170 Anchor Locations

3

57

3

Some power tools are required so ensure all equipments safety guidelines are followed.

Ensure no electrical cables or other services are run beneath the walls surface prior to drilling.

Minor adjustments to the unit’s position can be made via the thumb screws. When adjustments are complete and the system is securely fastened to the wall, use the supplied chrome caps to conceal the fasteners and holes to complete the installation.

x8

Install anchors or otherwise prepare the attachment points for the fasteners.

Use eight fasteners (not supplied) to securely anchor the plates to the wall. You must use fasteners appropriate for your specific wall structure to ensure that the plates may be securely anchored.

Be sure to use all four anchor points for eachwall plate to secure the plate to the wall.

x8

Use a thumb screw to attach each of the L-brackets to the system chassis. Once in place and attached, ensure that the chassis is plumb. Fully tighten the thumb screws, both at the chassis and at the wall plate, to secure the system to the wall.

Locate the two L-brackets. Slide them into the wall plates and use a thumb screw to hold each in place. Leave the thumb screws somewhat loose for now.

x2

Be sure to use fasteners appropriate foryour wall structure.

x8

If your chosen fasteners require holes to be drilled, use the eight pencil marks as a guide.

x2

7

8

7a

8a

7b

9

Page 4: RealPresence Medialign Slimline Base Wall Bracket Assembly ... · FLOOR LEVEL (FFL) DIMENSIONS IN MM DIMENSIONS IN MM Anchor Locations - RealPresence Medialign 170 Anchor Locations

4

The RealPresence Medialign 255 has two attachment points on the top outer corners of the chassis. Use the L-brackets and thumb screws to secure the chassis to the wall plates.

DIMENSIONS IN MM DIMENSIONS IN MM

Anchor Locations - RealPresence Medialign 255Anchor Locations - RealPresence Medialign 155

FLOOR LEVEL (FFL)

SYMMETRIC

2.75"(70.0 mm)

21"(532.0 mm)

FLOOR LEVEL (FFL)

SYMMETRIC

The RealPresence Medialign 155 has two attachment points on the top outer corners of the chassis. Use the L-brackets and thumb screws to secure the chassis to the wall plates.

x2 x2

2"(5

0.0

mm

)55

.25"

(140

3.0

mm

)

2"(5

0.0

mm

)55

.25"

(140

3.0

mm

)

2.75"(70.0 mm) 71.5"

(1816.0 mm)

Page 5: RealPresence Medialign Slimline Base Wall Bracket Assembly ... · FLOOR LEVEL (FFL) DIMENSIONS IN MM DIMENSIONS IN MM Anchor Locations - RealPresence Medialign 170 Anchor Locations

5© 2016, Polycom, Inc. All rights reserved. POLYCOM® and the names and marks associated with Polycom's products are trademarks and/or service marks of Polycom, Inc. and are registered and/orcommon law marks in the United States and various other countries. All other trademarks are property of their respective owners.

2"(5

0.0

mm

)63

"(1

599.

2 m

m)

2.75"(70.0 mm)

59.2"(1504.0 mm)

2"(5

0.0

mm

)63

"(1

599.

2 m

m)

2.75"(70.0 mm)

122.8"(3120.0 mm)

SYMMETRIC

FLOOR LEVEL (FFL)

SYMMETRIC

FLOOR LEVEL (FFL)

DIMENSIONS IN MM DIMENSIONS IN MM

Anchor Locations - RealPresence Medialign 270Anchor Locations - RealPresence Medialign 170

The RealPresence Medialign 270 has two attachment points on the top outer corners of the chassis. Use the L-brackets and thumb screws to secure the chassis to the wall plates.

The RealPresence Medialign 170 has two attachment points on the top outer corners of the chassis. Use the L-brackets and thumb screws to secure the chassis to the wall plates.