readout of temperature monitor with seabas 11 10/12 y. takubo (kek) 1
DESCRIPTION
Operation signals SDA SCL CONVB 3 We have no output from ADC. We investigated the response more carefully.TRANSCRIPT
![Page 1: Readout of Temperature Monitor with SEABAS 11 10/12 Y. Takubo (KEK) 1](https://reader036.vdocuments.mx/reader036/viewer/2022082910/5a4d1b8e7f8b9ab0599c0508/html5/thumbnails/1.jpg)
Readout of Temperature Monitor with SEABAS
’11 10/12 Y. Takubo (KEK)
1
![Page 2: Readout of Temperature Monitor with SEABAS 11 10/12 Y. Takubo (KEK) 1](https://reader036.vdocuments.mx/reader036/viewer/2022082910/5a4d1b8e7f8b9ab0599c0508/html5/thumbnails/2.jpg)
Setup
2
AD7887
SMB
SEABAS
Module
BCC board
• Two ADCs are mounted on SMB to read 16 temperature monitors.• SDA and SCL are pulled up by FPGA on SEABAS.
![Page 3: Readout of Temperature Monitor with SEABAS 11 10/12 Y. Takubo (KEK) 1](https://reader036.vdocuments.mx/reader036/viewer/2022082910/5a4d1b8e7f8b9ab0599c0508/html5/thumbnails/3.jpg)
Operation signals
SDA
SCL
CONVB
3
We have no output from ADC. We investigated the response more carefully.
![Page 4: Readout of Temperature Monitor with SEABAS 11 10/12 Y. Takubo (KEK) 1](https://reader036.vdocuments.mx/reader036/viewer/2022082910/5a4d1b8e7f8b9ab0599c0508/html5/thumbnails/4.jpg)
Response from ADCSDA
SCL
CONVB
Address byte: 01000100with write mode
4
This bit must be pulled down by the ADC.
If you have any suggestions, please let me know.