This guide provides procedures for setting up and configuring the Extron RCP 2000 Remote Control Panel with ISS 506 Support. IP Setup The RCP 2000 is delivered with a factory default IP address of 192.168.254.253. If you want to change this address, or need to enter other information required for Ethernet or serial communication, follow these steps: 1. Press the Color/Tint, Cont/Bright, Size, and Center picture control buttons simultaneously and hold them until the Cut button lights (about 2 seconds). The RCP's MAC address is displayed on the LCD screen. 2. Press the Cut or Take button repeatedly to step through the IP Setup menu options to access the item to be changed. 3. If adjusting one of the four IP settings (RCP IP address, switcher IP address, subnet mask, or Gateway), press the Color/Tint, Cont/Bright, Size, or Center button to select an address block (octet) to change. The selected octet on the LCD screen blinks. 4. Rotate the H Adjust knob to change the selected value. 5. When finished, press the Detail button to save the configuration and exit IP Setup. Press Default Cycle CUT Press CUT Step 1 Step 3 Step 5 Press CUT Press Color/Tint, Cont/Bright, Size, and Center and hold for 2 sec. Rotate the H knob to change the selected IP address segment, set the baud rate, or turn DHCP on and off. Press each Picture Control button to select the next IP address segment. Step 2 Step 4 A6-00-B7 00-0F-2B Press the Detail button to save the configuration and exit IP Setup. CENTER SIZE CONT BRIGHT COLOR TINT I 010.056 P142.008 MAC address RCP’s IP address S010.056 I 003.212 Switcher’s IP S255.255 M255.000 Subnet mask Press CUT DHCP Off CENTER SIZE CONT BRIGHT COLOR TINT Select 1st octet Select 3rd octet Select 2nd octet Select 4th octet H 000-255 G010.056 M000.100 Gateway IP RCP Baud 9600 Press CUT Press CUT Press CUT Sw Baud 9600 Press CUT H 9600-115,200 H 9600-115,200 Press the Cut button to cycle through the IP Setup menu options. Press simultaneously. DETAIL 68-1608-01 Rev. A 08 08 RCP 2000 with ISS 506 Support Setup Guide 2 3 4 5 6 7 8 CUT CONT BRIGHT H V COLOR TINT WIPE DISSOLVE TAKE 2 3 4 5 6 7 8 PROGRAM ADJUST PICTURE CONTROLS PREVIEW ION LOGO 1 /BLACK LOGO 2 /BLACK LOGO 1 /BLACK LOGO 2 /BLACK SIZE CENTER DETAIL AUTO IMAGE Press and hold all four buttons. The CUT button lights. A6-00-B7 00-0F-2B After 2 seconds, the display shows the MAC address. 01 = Dissolve (PIP only) 10 = S 02 = Soft Right 11 = S 03 = Soft Left 12 = S 04 = Soft Up 13 = S 05 = Soft Down 14 = 06 = Soft Center In 15 = 07 = Soft Center Out 16 = 08 = Soft Curtain In 17 = 09 = Soft Curtain Out Wipe an Step 1

Upload: vuongxuyen

Post on 04-Oct-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

This guide provides procedures for setting up and configuring the Extron RCP 2000 Remote Control Panel with ISS 506 Support.

IP SetupThe RCP 2000 is delivered with a factory default IP address of 192.168.254.253. If you want to change this address, or need to enter other information required for Ethernet or serial communication, follow these steps:

1. Press the Color/Tint, Cont/Bright, Size, and Center picture control buttons simultaneously and hold them until the Cut button lights (about 2 seconds). The RCP's MAC address is displayed on the LCD screen.

2. Press the Cut or Take button repeatedly to step through the IP Setup menu options to access the item to be changed.

3. If adjusting one of the four IP settings (RCP IP address, switcher IP address, subnet mask, or Gateway), press the Color/Tint, Cont/Bright, Size, or Center button to select an address block (octet) to change. The selected octet on the LCD screen blinks.

4. Rotate the H Adjust knob to change the selected value.

5. When finished, press the Detail button to save the configuration and exit IP Setup.

Press

DefaultCycle

CUT

Press

CUT

Step1

Step3

Step5

Press

CUT

Press Color/Tint, Cont/Bright, Size, and Center and hold for 2 sec.

Rotate the H knob to change the selected IP address segment, set the baud rate, or turn DHCP on and off.

Press each Picture Control button to select the next IP address segment.

Step2

Step4

A6-00-B700-0F-2B

Press the Detail button to save the configuration and exit IP Setup.

CENTERSIZECONTBRIGHT

COLORTINT

I 010.056P142.008

MAC address RCP’s IP address

S010.056I 003.212

Switcher’s IP

S255.255M255.000

Subnet mask Press

CUT

DHCPOff

CENTERSIZECONTBRIGHT

COLORTINT

Select1st octet

Select3rd octet

Select2nd octet

Select4th octet

H 000-255

G010.056M000.100

Gateway IP

RCP Baud9600

Press

CUT

Press

CUT

Press

CUT

Sw Baud9600

Press

CUT

H

9600-115,200

H

9600-115,200

Press the Cut button to cycle through the IP Setup menu options.

Press simultaneously.

DETAIL

68-1608-01 Rev. A08 08

RCP 2000 with ISS 506 Support Setup Guide

2 3 4 5 6 7 8

CUT

CONTBRIGHT

H

V

COLORTINT

WIPE DISSOLVE

TAKE2 3 4 5 6 7 8

PROGRAM

ADJUST

PICTURE CONTROLS

PREVIEW ION

LOGO 1/BLACK

LOGO 2/BLACK

LOGO 1/BLACK

LOGO 2/BLACK

SIZE CENTER DETAIL

AUTOIMAGE

Press and holdall four buttons.

The CUT button lights.

A6-00-B700-0F-2B

After 2 seconds, the display shows the MAC address.

01 = Dissolve (PIP only) 10 = S02 = Soft Right 11 = S03 = Soft Left 12 = S04 = Soft Up 13 = S05 = Soft Down 14 = 06 = Soft Center In 15 =07 = Soft Center Out 16 = 08 = Soft Curtain In 17 =09 = Soft Curtain Out

Wipe an

Step

1

RCP 2000 with ISS 506 Support • Setup Guide2

RCP 2000 with ISS 506 Support Setup Guide (cont'd)

RS-232 SetupTo configure an RS-232 connection to the switcher,

1. Plug the supplied 12' RS-232 cable into the RCP's rear panel To Switcher port and the switcher's RS-232/422 port.

2. Press and hold the Color/Tint, Cont/Bright, Size, and Center buttons simultaneously until the Cut button lights and the MAC address appears in the LCD window.

3. Press Cut two times, until the switcher IP address is displayed in the LCD window. The Color/Tint button flashes.

4. Set the switcher's IP address to 000.000.000.000 as follows:

a. Press one of the picture control buttons to access the desired octet of the switcher's IP address. Access the address blocks as follows:

Select 1st octet Select 2nd octet Select 3rd octet Select 4th octet

b. When the desired octet is blinking in the LCD window, rotate the H knob all the way to the left to set the address block to 000.

c. Repeat steps a and b as needed for each address block that needs to be set to 000.

5. If you need to change the switcher's baud rate, press Cut repeatedly until the Sw Baud screen appears.

Rotate the H knob to set the switcher's baud rate.

6. Press Detail to exit the setup menu.

Selecting Transition EffectsSelecting wipe, PIP, and title effects

To select a wipe, PIP, or title effect,

1. Press and hold the Wipe button.

2. While holding the Wipe button, press the Dissolve

button repeatedly to cycle through the Wipe, Pip, and Title menus.

For Title, press Wipe + Dissolve until Title Lvl is displayed on the LCD screen, then skip to step 4.

3. When the desired function (Wipe or Pip) is displayed in the LCD window, continue to hold down the Wipe button while turning the Adjust knob to select the number of the desired sub-effect (02 through 25 for Wipe; 01 through 25 for PIP). See the label in the upper-right corner of the RCP front panel for a list of available effects.

N You can not select a cut sub-effect while in Wipe or PIP mode. To perform a cut in these modes, select the desired preview input, then press the Cut button.

4. Release the Wipe button (it should remain lit), and rotate the Adjust knob to select the duration of the sub-effect (0.0 to 5.0 seconds) or the intensity level (Lvl) of the preview image that will become transparent in Title mode (000 to 255).

N If you want to control the duration of the wipe and PIP effects manually, move the T handle up or down at the desired rate.

5. Press the Take button to implement your effect on the selected preview input.

WIPE DISSOLVE

Pressand hold

Press to step through menu

+

WIPE

Hold

Rotate to select wipe

+ADJUST

Press Press

ADJUST

Press

02-25

ADJUST

01-25

DISSOLVE DISSOLVE

DISSOLVE

Wipe #030.5 Sec

Pip #030.5 Sec

Title Lvl 150

DefaultCycle

WIPE

Press and hold

ADJUST

0.0-5.0 Sec.

ADJUST

0.0-5.0 Sec.

ADJUST

0-255WIPE

WIPE

Release

WIPE

Release

Release

COLORTINT

Press

CONTBRIGHT

Press

SIZE

Press

CENTER

Press

S 000.000I 000.000

HRotate to set blinking octet to 000.

Sw Baud9600

H

9600-115,200

Selecting a cut (full screen program/preview swap)To select a full screen cut transition (immediate and seamless replacement of the program image with the preview image),

1. With the RCP in Wipe or Dissolve mode, select a preview input.

2. Press the Cut button. The selected preview image immediately becomes the program image.

Selecting a dissolveTo select a dissolve effect (the program image fades out while the preview image fades in),

1. Select a preview input.

2. Press the Dissolve button, which lights.

3. While the Dissolve button is lit, rotate the Adjust knob to select the duration in seconds (0.0 through 5.0) of the dissolve effect.

4. Press Take to execute the dissolve effect.

N If you want to control the duration of the dissolve manually, move the T-bar handle up or down at the desired rate.

Using Picture ControlsThe Picture Controls buttons, located near the top of the front panel, let you adjust settings on the preview output.

1. Select a Preview input.

2. Select a transition effect (wipe, PIP, title, or dissolve).

3. Press a picture control button.

4. Rotate the H and/or V adjustment knobs, located to the right of the buttons, to select the values, as shown below.

Color/Tint

COLORTINT

V

HPress

Adjust color

Adjust tint

Col Tint064 064

Contrast/ brightness

CONTBRIGHT

V

H

Press

Adjust contrast

Adjust brightness

Con Brt 064 064

Detail

DETAIL

V

HPress

Adjust sharpness

Detail064

or

Pip Det064

Image size

SIZE

V

HPress

Adjust width

Adjust height

Hsz 1024Vsz 0786

H W 0513V W 0386

Wipe, dissolve, and title modes

PIP mode

H I 0513V I 0386

Window size Image size

In PIP mode: Press the Size button again to toggle between window size and image size adjustment.

The Size button stays lit steadily during window size adjustment and blinks during image size adjustment.

Centering

CENTER

V

H

PressAdjust horizontalposition

Adjust vertical position

Hsh 2048Vsh 2048

H W 0640V W 0480

Wipe, dissolve, and title modes

PIP mode

H I 0640V I 0480

Window position Image position

In PIP mode: Press the Center button again to toggle between window position and image position.

The Center button stays lit during window position adjustment and blinks during image position adjustment.

RCP 2000 with ISS 506 Support Setup Guide (cont'd)

COLORTINT

CONTBRIGHT

SIZE CENTER DETAIL

PICTURE CONTROLSH

V

DISSOLVE

Press

Rotate to select dissolveduration.

+ADJUST

CUT

Press

RCP 2000 with ISS 506 Support • Setup Guide 3

N Picture controls affect only the current preview input.

N If the current PIP or Title preview input is active on the program output, no picture control adjustment is possible.

TAKE

Press

© 2008 Extron Electronics. All rights reserved.

Other Button ControlsThe following additional functions are accessed via the Program and/or Preview buttons:

1 2 3 4 5 6 7 8

2 3 4 5 6 7 8

PROGRAM

ADJUS

PREVIEWCOMMUNICATION

LOGO 1/BLACK

LOGO 2/BLACK

LOGO 1/BLACK

LOGO 2/BLACK

AUTOIMAGE

1 2

2

FREEZE BLACK

FREEZE BLACK

1

a Auto Image — Press this Preview button to perform an immediate auto image adjustment on the preview input. Auto Image enables you to automatically size and center the selected preview input to fill the screen.

b Logo — Press the Logo 1/Black or Logo 2/Black Preview or Program button to display a logo on the screen. If a logo has been assigned, the button lights steadily when pressed.

N Logos must be set up/assigned on the ISS 506 switcher. If no logo is assigned, pressing a Logo button has the same effect as pressing the Black button — a black screen is displayed and the Logo button flashes. (To switch to or from the black screen, apply a cut or other effect.)

Preview User PresetsUser presets save color, tint, contrast, brightness, detail, sizing, and centering settings on the ISS 506. Up to three presets can be saved on each input. You can recall a preset that was saved to an input button on the ISS 506 by pressing the equivalent Preview input button on the RCP.

2 3 4 5 6 7 8PREVIEW

COMMUNICATION

LOGO 1/BLACK

LOGO 2/BLACK

AUTOIMAGE

FREEZE BLACK 1

Preview Input Buttons

To recall a preset,

1. Press the desired Preview input button twice to place the RCP in preset mode and start the presets cycle. The first preset name is displayed in the LCD window.

2. Press the input button repeatedly until the desired preset name is displayed.

To exit preset mode, press another Preview input button.

N If no user presets have been saved, additional presses of the current preview input button have no effect.

RCP 2000 with ISS 506 Support Setup Guide (cont'd)

UserPreset 1

Extron USA - West Headquarters

+800.633.9876Inside USA / Canada Only

+1.714.491.1500+1.714.491.1517 FAX

Extron USA - East

+800.633.9876Inside USA / Canada Only

+1.919.863.1794+1.919.863.1797 FAX

Extron Europe

+800.3987.6673Inside Europe Only

+31.33.453.4040+31.33.453.4050 FAX

Extron Asia

+800.7339.8766Inside Asia Only

+65.6383.4400+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655+81.3.3511.7656 FAX

Extron China

+400.883.1568Inside China Only

+86.21.3760.1568+86.21.3760.1566 FAX

Extron Dubai

+971.4.2991800+971.4.2991880 FAX