rapid emergency methods for actinides and sr-89/90

14
Rapid Emergency Methods for Actinides and Sr-89/90 Sherrod L. Maxwell, III Westinghouse Savannah River Company

Upload: jorn

Post on 12-Jan-2016

26 views

Category:

Documents


0 download

DESCRIPTION

Rapid Emergency Methods for Actinides and Sr-89/90. Sherrod L. Maxwell, III Westinghouse Savannah River Company. Background. Radiological Preparedness Exercise (NRIP’04) Kenneth Inn, NIST spoke at RRMC-2004 of “need to improve efficiency and effectiveness of radioanalytical capabilities” - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Rapid Emergency Methods for Actinides  and Sr-89/90

Rapid Emergency Methods for Actinides and Sr-89/90

Sherrod L. Maxwell, III

Westinghouse Savannah River Company

Page 2: Rapid Emergency Methods for Actinides  and Sr-89/90

Background

• Radiological Preparedness Exercise (NRIP’04)– Kenneth Inn, NIST

– spoke at RRMC-2004 of “need to improve efficiency and effectiveness of radioanalytical capabilities”

• Need for faster actinide and Sr-89/90 analyses for Homeland Security reasons

• Current water/air filter methods may take 1-2 days • Need for fast, reliable methods (< 8 hours)

Page 3: Rapid Emergency Methods for Actinides  and Sr-89/90

Developments at SRS

• Water/Air Filters Method– Streamline calcium phosphate precipitation

(water)– Dissolve air filters– Collect and prepare Sr-89/90 with actinides– No ashing of Am/Cm or Th fractions

• Eichrom prefilter cartridges/Resolve filters

Page 4: Rapid Emergency Methods for Actinides  and Sr-89/90

Developments at SRS• Streamline calcium phosphate precipitation

– Eliminate heat step for volumes less than 200 mL/add Ba to complex carbonate

– Use 200 mL (or less) sample volumes in centrifuge tubes– Prep time: ~1-1.5 hours-12 samples

• Stack TEVA (Pu, Np, Th) + TRU (Am,Cm, U) + Sr Resin (Sr-89/90)– Collect Sr-89/90 at same time– Prep time: <4 hours-12 samples

• Count time– actinides-1 hour (or as needed)– Sr-89/90-10 minutes (or as needed)

Page 5: Rapid Emergency Methods for Actinides  and Sr-89/90

Rapid TEVA-TRU-Sr Separations(Pu, Np, Am, Cm, U, Sr)

Page 6: Rapid Emergency Methods for Actinides  and Sr-89/90

Remove Sr on Sr Resin, Pu from TEVA and Am-Cm/U from TRU

Page 7: Rapid Emergency Methods for Actinides  and Sr-89/90

Am Strip with Prefilters Below TRU

Page 8: Rapid Emergency Methods for Actinides  and Sr-89/90

Performance

• 20 groundwater samples • 200 mL volume/ 6 hour counts *• Sr carrier recoveries: 98.1% (3.9% rsd)• Pu-242 recoveries: 104% (4.9% rsd)• Am-243 recoveries: 92.6% (6% rsd)• U-232 recoveries: 85.6% (5.4% rsd)

*count less time in emergency when high levels expected

Page 9: Rapid Emergency Methods for Actinides  and Sr-89/90

Other Efficiency Improvements

• Eliminate ashing steps used for extractant bleed-off that affects alpha resolution

• Prefilter cartridge(~$5) with Resolve filters– Saves time, labor, better FWHM– faster TAT– improved alpha resolution– less rework

Page 10: Rapid Emergency Methods for Actinides  and Sr-89/90

Resolution with Filters from “Bad” Lot

Page 11: Rapid Emergency Methods for Actinides  and Sr-89/90
Page 12: Rapid Emergency Methods for Actinides  and Sr-89/90
Page 13: Rapid Emergency Methods for Actinides  and Sr-89/90
Page 14: Rapid Emergency Methods for Actinides  and Sr-89/90

Summary

• Need to share radioanalytical methods-Ken Inn• Faster actinide and Sr-89/90 methods developed

– Quality and Speed– Streamlined precipitation for water samples– Collect Pu, Am, Cm, U, Sr in a single stacked column– High recoveries, good resolution, no interferences

• Applicable to radiological emergency analyses– Improved efficiency and effectiveness– Short count as needed– Analysis time < 8 hours