SURVEYINFORMATION
SURVEYED BY:TOTAL SURVEYING SOLUTIONS
DATUM: A.H.D.ORIGIN OF LEVELS: SSM83806 RL180.995
LAST SAVED BY:MSTIMOVA
01 ISSUED FOR CONSTRUCTION CERTIFICATE KR IA 06.09.2019
Date
Scale
Title
Project
Drawing number
Drawn
Checked
Revision
Designed
Approved
This drawing and design remains the property of Henry & Hymas and may not becopied in whole or in part without the prior written approval of Henry & Hymas.
Client
REVISION AMENDMENT DATEREVISION AMENDMENT DATE
Surveyor
DESIGNEDDRAWNDESIGNEDDRAWNhymas&henry
Level 5,
79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
Web
www.henryandhymas.com.au
Qua l
i t y Manag emen t . I SO 9 001
Global-Mark.com.au® 0218380_CC_EX000
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA NSW
COVER SHEET, DRAWING SCHEDULE,NOTES AND LOCALITY SKETCH
J.Knight I.Ahmed
A.Francis A.Francis
AUG 2019
NTS
ADCO CONSTRUCTION PTY LTD
TOTAL SURVEYING SOLUTIONS
DRAWING SCHEDULE18380_CC_EX000 COVER SHEET, DRAWING SCHEDULE, NOTES AND LOCALITY SKETCH
18380_CC_EX100 GENERAL ARRANGEMENT PLAN
18380_CC_EX110 RAISED PEDESTRIAN CROSSING PLAN
18380_CC_EX111 RAISED PEDESTRIAN CROSSING DETAILS AND SECTIONS
18380_CC_EX610 LINEMARKING AND SIGNPOSTING PLAN
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA, NSW
CIVIL ENGINEERING WORKSGENERAL NOTES:1. ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH HORNSBY SHIRE COUNCIL'S
SPECIFICATION. CONTRACTOR TO OBTAIN AND RETAIN A COPY ON SITE DURING THECOURSE OF THE WORKS.
2. ALL NEW WORKS ARE TO MAKE A SMOOTH JUNCTION WITH EXISTING CONDITIONS ANDMARRY IN A 'WORKMANLIKE' MANNER.
3. THE CONTRACTOR IS TO VERIFY THE LOCATION OF ALL SERVICES WITH EACH RELEVANTAUTHORITY. ANY DAMAGE TO SERVICES SHALL BE RECTIFIED BY THE CONTRACTOR ORTHE RELEVANT AUTHORITY AT THE CONTRACTOR'S EXPENSE. SERVICES SHOWN ONTHESE PLANS ARE ONLY THOSE EVIDENT AT THE TIME OF SURVEY OR AS DETERMINEDFROM SERVICE DIAGRAMS. HENRY AND HYMAS CONSULTING PTY. LTD. CANNOTGUARANTEE THE INFORMATION SHOWN NOR ACCEPT ANY RESPONSIBILITY FORINACCURACIES OR INCOMPLETE DATA.
4. SERVICES & ACCESSES TO THE EXISTING PROPERTIES ARE TO BE MAINTAINED INWORKING ORDER AT ALL TIMES DURING CONSTRUCTION.
5. ADJUST EXISTING SERVICE COVERS TO SUIT NEW FINISHED LEVELS TO RELEVANTAUTHORITY REQUIREMENTS WHERE NECESSARY.
6. REINSTATE AND STABILISE ALL DISTURBED LANDSCAPED AREAS.
7. MINIMUM GRADE OF SUBSOIL SHALL BE 0.5% (1:200) FALL TO OUTLETS.
8. ALL TEMPORARY SEDIMENT AND EROSION CONTROL DEVICES ARE TO BE CONSTRUCTED,PLACED AND MAINTAINED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS,EROSION AND SEDIMENTATION CONTROL PLAN AND HORNSBY SHIRE COUNCIL'SREQUIREMENTS WHERE APPLICABLE.
9. CONTRACTOR TO CHECK AND CONFIRM SITE DRAINAGE CONNECTIONS ACROSS THEVERGE PRIOR TO COMMENCEMENT OF SITE DRAINAGE WORKS.
10. PROPERTIES AFFECTED BY THE WORKS ARE TO BE NOTIFIED IN ADVANCE WHEREDISRUPTION TO EXISTING ACCESS IS LIKELY.
EXISTING SERVICES & FEATURES· THE CONTRACTOR SHALL ALLOW FOR THE CAPPING OFF, EXCAVATION AND REMOVAL (IF
REQUIRED) OF ALL EXISTING SERVICES IN AREAS AFFECTED BY WORKS WITHIN THECONTRACT AREA OR AS SHOWN ON THE DRAWINGS UNLESS DIRECTED OTHERWISE BYTHE SUPERINTENDENT.
· THE CONTRACTOR SHALL ENSURE THAT AT ALL TIMES SERVICES TO ALL BUILDINGS NOTAFFECTED BY THE WORKS ARE NOT DISRUPTED.
· PRIOR TO COMMENCEMENT OF ANY WORKS THE CONTRACTOR SHALL GAIN APPROVAL OFHIS PROGRAM FOR THE RELOCATION/ CONSTRUCTION OF TEMPORARY SERVICES.
· CONTRACTOR SHALL CONSTRUCT TEMPORARY SERVICES TO MAINTAIN SUPPLY TOEXISTING BUILDING REMAINING IN OPERATION DURING WORKS TO THE SATISFACTION ANDAPPROVAL OF THE SUPERINTENDENT. ONCE DIVERSION IS COMPLETE ANDCOMMISSIONED, THE CONTRACTOR SHALL REMOVE ALL SUCH TEMPORARY SERVICES ANDMAKE GOOD TO THE SATISFACTION OF THE SUPERINTENDENT.
· INTERRUPTION TO SUPPLY OF EXISTING SERVICES SHALL BE DONE SO AS NOT TO CAUSEANY INCONVENIENCE TO THE PRINCIPAL. CONTRACTOR TO GAIN APPROVAL FROM THESUPERINTENDENT FOR TIME OF INTERRUPTION.
· EXISTING SERVICES, BUILDINGS, EXTERNAL STRUCTURES AND TREES SHOWN ON THESEDRAWINGS ARE EXISTING FEATURES PRIOR TO ANY DEMOLITION WORKS.
· EXISTING SERVICES UNLESS SHOWN ON SURVEY PLAN HAVE BEEN PLOTTED FROMSERVICES SEARCH PLANS AND AS SUCH THEIR ACCURACY CANNOT BE GUARANTEED. IT ISTHE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETE A 'DIAL BEFORE YOU DIG'SEARCH AND TO ESTABLISH THE LOCATION AND LEVEL OF ALL EXISTING SERVICES PRIORTO THE COMMENCEMENT OF ANY WORK. ANY DISCREPANCIES SHALL BE REPORTED TOTHE SUPERINTENDENT. CLEARANCES SHALL BE OBTAINED FROM THE RELEVANT SERVICEAUTHORITY.
· ALL BRANCH GAS AND WATER SERVICES UNDER DRIVEWAYS AND BRICK PAVING SHALL BELOCATED IN Ø80 uPVC SEWER GRADE CONDUITS EXTENDING A MINIMUM OF 500mmBEYOND EDGE OF PAVING.
SITEWORKS NOTES· DATUM : A.H.D.
· ORIGIN OF LEVELS : REFER TO BENCH OR STATE SURVEY MARKS WHERESHOWN ON PLAN.
· CONTRACTOR MUST VERIFY ALL DIMENSIONS AND EXISTING LEVELS ON SITEPRIOR TO THE COMMENCEMENT OF WORK.
· ALL WORKS TO BE UNDERTAKEN IN ACCORDANCE WITH THE DETAILS SHOWNON THE DRAWINGS & THE DIRECTIONS OF THE SUPERINTENDENT.
· EXISTING SERVICES UNLESS SHOWN ON THE SURVEY PLAN HAVE BEENPLOTTED FROM SERVICES SEARCH PLANS AND AS SUCH THEIR ACCURACYCANNOT BE GUARANTEED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOESTABLISH THE LOCATION AND LEVEL OF ALL EXISTING SERVICES PRIOR TOTHE COMMENCEMENT OF ANY WORK. ANY DISCREPANCIES SHALL BEREPORTED TO THE SUPERINTENDENT. CLEARANCES SHALL BE OBTAINEDFROM THE RELEVANT SERVICE AUTHORITY.
· WHERE NEW WORKS ABUT EXISTING THE CONTRACTOR SHALL ENSURE THAT ASMOOTH EVEN PROFILE, FREE FROM ABRUPT CHANGES IS ACHIEVED.
· THE CONTRACTOR SHALL ARRANGE ALL SURVEY SETOUT TO BE CARRIED OUTBY A REGISTERED SURVEYOR.
· CARE IS TO BE TAKEN WHEN EXCAVATING NEAR EXISTING SERVICES. NOMECHANICAL EXCAVATION IS TO BE UNDERTAKEN OVER TELSTRA ORELECTRICAL SERVICES. HAND EXCAVATE IN THESE AREAS.
· CONTRACTOR TO OBTAIN AUTHORITY APPROVALS WHERE APPLICABLE.
· MAKE SMOOTH TRANSITION TO EXISTING SURFACES AND MAKE GOOD.
· THESE PLANS SHALL BE READ IN CONJUNCTION WITH APPROVED LANDSCAPE,ARCHITECTURAL, STRUCTURAL, HYDRAULIC AND MECHANICAL DRAWINGS ANDSPECIFICATIONSOR WRITTEN INSTRUCTIONS THAT MAY BE ISSUED RELATINGTO DEVELOPMENT AT THE SITE.
· TRENCHES THROUGH EXISTING ROAD AND CONCRETE PAVEMENTS SHALL BESAWCUT TO FULL DEPTH OF CONCRETE AND A MINIMUM OF 50mm INBITUMINOUS PAVING.
· ALL BRANCH GAS AND WATER SERVICES UNDER DRIVEWAYS AND BRICKPAVING SHALL BE LOCATED IN Ø80 uPVC SEWER GRADE CONDUITS EXTENDINGA MINIMUM OF 500mm BEYOND EDGE OF PAVING.
· GRADES TO PAVEMENTS TO BE AS IMPLIED BY RL'S ON PLAN . GRADE EVENLYBETWEEN NOMINATED RL'S. AREAS EXHIBITING PONDING GREATER THAN 5mmDEPTH WILL NOT BE ACCEPTED UNLESS IN A DESIGNATED SAG POINT.
· ALL COVERS AND GRATES ETC TO EXISTING SERVICE UTILITIES ARE TO BEADJUSTED TO SUIT NEW FINISHED SURFACE LEVELS WHERE APPLICABLE.
SURVEY NOTESTHE EXISTING SITE CONDITIONS SHOWN ON THE FOLLOWING DRAWINGS HAVEBEEN INVESTIGATED BY THE SURVEYOR SPECIFIED IN THE TITLE BLOCK.THE INFORMATION IS SHOWN TO PROVIDE A BASIS FOR DESIGN. HENRY AND HYMASPTY. LTD. DOES NOT GUARANTEE THE ACCURACY OR COMPLETENESS OF THESURVEY BASE OR ITS SUITABILITY AS A BASIS FOR CONSTRUCTION DRAWINGS.SHOULD DISCREPANCIES BE ENCOUNTERED DURING CONSTRUCTION BETWEENTHE SURVEY DATA AND ACTUAL FIELD DATA, CONTACT HENRY AND HYMAS PTY.LTD. THE FOLLOWING NOTES HAVE BEEN TAKEN DIRECTLY FROM ORIGINALSURVEY DOCUMENTS.ORIGIN OF LEVELS SSM 83806 RL180.995DATUM AHD
PROPOSED SITE
LOCALITY SKETCHNTS
02 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 22.11.2019
MYRA STREET
EXISTING DRIVEWAYS
EXISTING FOOTPATH TO BE RETAINED
RAISED PEDESTRIAN CROSSINGREFER TO DWG EX110 FORDETAILS
EXISTING DRIVEWAY
EXISTING KERB INLETPIT TO BE RETAINED
EXISTING TREE TO BERETAINED
RECONSTRUCT FOOTPATHTO SUIT NEW LEVELS
RECONSTRUCT FOOTPATHTO SUIT NEW LEVELS
KERB BLISTERS. REFER TODWG EX110 FOR MORE DETAILS
EXISTING SERVICE PIT TO BE RETAINED
LANDING
LAST SAVED BY:MSTIMOVA
01 ISSUED FOR CONSTRUCTION CERTIFICATE KR IA 06.09.2019
Date
Scale
Title
Project
Drawing number
Drawn
Checked
Revision
Designed
Approved
This drawing and design remains the property of Henry & Hymas and may not becopied in whole or in part without the prior written approval of Henry & Hymas.
Client
REVISION AMENDMENT DATEREVISION AMENDMENT DATE
Surveyor
DESIGNEDDRAWNDESIGNEDDRAWNhymas&henry
Level 5,
79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
Web
www.henryandhymas.com.au
Qua l
i t y Manag emen t . I SO 9 001
Global-Mark.com.au® 0418380_CC_EX100
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA NSW
GENERAL ARRANGEMENT PLAN
K.Rom I.Ahmed
A.Francis A.Francis
AUG 2019
1:100@A1
ADCO CONSTRUCTION PTY LTD
TOTAL SURVEYING SOLUTIONS
10m864
SCALE 1:100
20
12
GENERAL ARRANGEMENT PLANSCALE 1:100
LEGEND
EXISTING BOUNDARY
EXISTING ELECTRICAL MAINS LINE
SURVEYINFORMATION
SURVEYED BY:TOTAL SURVEYING SOLUTIONS
DATUM: A.H.D.ORIGIN OF LEVELS: SSM83806 RL180.995
02 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 22.11.2019
LIMIT OF WORKS
PROPOSED KERB ONLYKO
03 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 30.01.2020
04 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 13.03.2020
1EX111
RL181.6
5
RL181.75
3600 10001000
EX K&G
KEBR RAMPS TO PEDESTRIANCROSSING TO BECONSTRUCTED INACCORDANCE WITH RMSMODEL DRAWING R0300-11
EXISTINGFOOTPATH TORETAIN
MYRA STREET
RL181.7
8
RL181.86
RL181.83
RL181.88
RL181.91
RL182.00
RL181.90
RL181.77
RL181.79
RL181.65
RL181.89
RL181.92
RL181.62
RL181.8
7
RL182.1
0
RL182.0
0
RL181.7
2
RL181.6
3
RL181.8
1
RL181.8
4
FOOTPATH TO TIEIN WITH EXISTINGLEVELS
LANDING
RL181.77
RL181.87 RL181.8
5
1500
1 in 1
2
FOOTPATH TO BERECONSTRUCTEDTO SUIT NEWLEVELS
LIMIT OF WORKS LIMIT OF WORKS
RE-CONSTRUCTEXISTING FOOTPATHTO SUIT NEW LEVELS
KERB RAMP TO PEDESTRIAN CROSSINGTO BE CONSTRUCTED IN ACCORDANCEWITH RMS MODEL DRAWING R0300-11
EXISTING GUTTERTO REMAIN
1 in 1
2
1500
EXISTINGLINEMARKING TOREMAIN
RAMP TO KERB RAMPEXISTING TREETO REMAIN
RAMP TO KERB RAMP
4066
4016
RL181.7
9
RL181.7
6
EX K&GIJ
IJ
EXISTING GUTTER TOREMAIN
RL181.94 RL181.9
9
RL182.0
2FALL
450mm GAP FORSTORMWATER FLOW TOGUTTER
450mm GAP FOR STORMWATERFLOW TO GUTTER
450
450
LAST SAVED BY:MSTIMOVA
01 ISSUED FOR CONSTRUCTION CERTIFICATE KR IA 06.09.2019
Date
Scale
Title
Project
Drawing number
Drawn
Checked
Revision
Designed
Approved
This drawing and design remains the property of Henry & Hymas and may not becopied in whole or in part without the prior written approval of Henry & Hymas.
Client
REVISION AMENDMENT DATEREVISION AMENDMENT DATE
Surveyor
DESIGNEDDRAWNDESIGNEDDRAWNhymas&henry
Level 5,
79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
Web
www.henryandhymas.com.au
Qua l
i t y Manag emen t . I SO 9 001
Global-Mark.com.au® 0418380_CC_EX110
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA NSW
RAISED PEDESTRIAN CROSSING PLAN
K.Rom I.Ahmed
A.Francis A.Francis
AUG 2019
AS NOTED
ADCO CONSTRUCTION PTY LTD
TOTAL SURVEYING SOLUTIONS
5000mm3000 400010000
2006001000
2000
SCALE 1:50
LEGEND
EXISTING BOUNDARY
EXISTING ELECTRICAL MAINS LINE
EXISTING GAS LINE
EXISTING TELSTRA LINES
EXISTING WATER LINE
DEMOLITION
EXISTING KERB
PAVEMENT TYPE 1CONCRETE LANDING & FOOTPATH
100mm THICK 25MPa CONCRETE WITH SL72 TOP,30mm COVER ON WATERPROOF MEMBERANE50mm THICK DGB 20 OR APPROVED EQUIVALENT
PAVEMENT TYPE 2KERB BLISTERS
180mm THICK 25MPa CONCRETEWITH SL72 50 TOP COVER
EXISTING SUBGRADE
EXISTING PAVEMENT
SURVEYINFORMATION
SURVEYED BY:TOTAL SURVEYING SOLUTIONS
DATUM: A.H.D.ORIGIN OF LEVELS: SSM83806 RL180.995
02 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 22.11.2019
RAISED PEDESTRIAN CROSSING PLANSCALE 1:50
LIMIT OF WORKS
ISOLATION JOINTIJ
03 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 30.01.2020
04 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 13.03.2020
TYPICAL CROSS SECTION ON RAISED THRESHOLDS
3600
SECTIONSCALE:
1EX1101:25
1000
COMPACTED SUB BASE
200 EXISTING AC PAVEMENT
10001010
DEEP LIFT AC BACKFILL FOR DISTURBEDPAVEMENT (AC14 WEARING COURSE).
30050 AC 14 OVER DEEPLIFT AC BACKFILL
200
EXISTING AC PAVEMENT
SL82 MESH, 50 TOP COVER
SL82 MESH, 75 BTM COVER
32 MPa CONCRETE
150
N16 TIE BAR, 800 LONG @ 400 c/cPLACE AT MID-DEPTH (TYPICAL)400 400
SL82 MESH, PLACED CENTRALLY
NOTES: 1. SURFACE COLOUR TO BE SPECIFIED BY THE SUPERINTENDENT 2. LIGHT BROOM FINISH TO ALL CONCRETE SURFACES
300
300
EXISTING KERB BEHIND 1000
SAWCUT
TYPICAL AT ALL WALLS AND COLUMNSISOLATION JOINT
SCALE 1:20
NOTE:1. ALL JOINTS TO BE SILICON
SEALED. REFER TO DETAILS.2. EXTERNAL SLAB TO HAVE
GALVANISED DOWELS
10
12
PARBURY'SROADSEAL SL OREQUIVALENET
'ABELFLEX' ORAPPROVEDEQUIVALENTDETAIL
N.T.S.
EXISTING GUTTER
PAVEMENT AS SPECIFIED
LAST SAVED BY:MSTIMOVA
Date
Scale
Title
Project
Drawing number
Drawn
Checked
Revision
Designed
Approved
This drawing and design remains the property of Henry & Hymas and may not becopied in whole or in part without the prior written approval of Henry & Hymas.
Client
REVISION AMENDMENT DATEREVISION AMENDMENT DATE
Surveyor
DESIGNEDDRAWNDESIGNEDDRAWNhymas&henry
Level 5,
79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
Web
www.henryandhymas.com.au
Qua l
i t y Manag emen t . I SO 9 001
Global-Mark.com.au® 0118380_CC_EX111
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA NSW
RAISED PEDESTRIAN CROSSING SECTIONSAND DETAILS
K.Rom I.Ahmed
A.Francis A.Francis
AUG 2019
AS NOTED
ADCO CONSTRUCTION PTY LTD
TOTAL SURVEYING SOLUTIONS
2000mm1200 16004000
200400
800
SCALE 1:20
2500mm1500 20005000
100300500
1000
SCALE 1:25
SURVEYINFORMATION
SURVEYED BY:TOTAL SURVEYING SOLUTIONS
DATUM: A.H.D.ORIGIN OF LEVELS: SSM83806 RL180.995 01 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 22.11.2019
R5-400 (L)
15000360024000
R5-400 (R) R3-1 R3-1
R3-1 R3-1R5-400 (L) R5-400 (R)
24000360015000
80000
80150
EXISTING BB LINE EXISTING BB LINE
CHILDREN CROSSING POST & FLAGREFER TO DETAIL
CHILDREN CROSSINGPOST & FLAGREFER TO DETAIL
TF
TF
6000
6000
W6-2 W6-3 W8-22
PP
TEL
W6-2W6-3W8-22
1.8m
CHILDREN CROSSING POST & FLAGSCALE 1:20
0.3m
0.3m
R3 - 3
POST: ALTERNATERED AND WHITEBANDS 300mm WIDE
LAST SAVED BY:MSTIMOVA
01 ISSUED FOR CONSTRUCTION CERTIFICATE KR IA 06.09.2019
Date
Scale
Title
Project
Drawing number
Drawn
Checked
Revision
Designed
Approved
This drawing and design remains the property of Henry & Hymas and may not becopied in whole or in part without the prior written approval of Henry & Hymas.
Client
REVISION AMENDMENT DATEREVISION AMENDMENT DATE
Surveyor
DESIGNEDDRAWNDESIGNEDDRAWNhymas&henry
Level 5,
79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
Web
www.henryandhymas.com.au
Qua l
i t y Manag emen t . I SO 9 001
Global-Mark.com.au® 0418380_CC_EX610
RAISED PEDESTRIAN CROSSING PROJECTMYRA STREET, WAHROONGA NSW
LINEMARKING AND SIGNPOSTING PLAN
K.Rom I.Ahmed
A.Francis A.Francis
AUG 2019
AS NOTED@A1
ADCO CONSTRUCTION PTY LTD
TOTAL SURVEYING SOLUTIONS
10m864
SCALE 1:100
20
12
LINEMARKING AND SIGNPOSTING PLANSCALE 1:100
LEGEND
EXISTING BOUNDARY
EXISTING ELECTRICAL MAINS LINE
EXISTING GAS LINE
EXISTING SEWER LINE
EXISTING TELSTRA LINES
EXISTING WATER LINE
PROPOSED SIGNPOST
EXISTING SIGNPOST
SURVEYINFORMATION
SURVEYED BY:TOTAL SURVEYING SOLUTIONS
DATUM: A.H.D.ORIGIN OF LEVELS: SSM83806 RL180.995
02 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 22.11.2019
TF STOP LINE WHITE0.30
DIMENSIONS (m)LINETYPE
USE COLOUR
03 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 30.01.2020
2000mm1200 16004000
200400
800
SCALE 1:20
04 ISSUED FOR CONSTRUCTION CERTIFICATE MS IA 13.03.2020