DESCRIPTION
ABL800 FLEX Introduction. RTC, December 2004. Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com. Agenda. Front view Rear view Modular design Parameters Analyzer configurations Specifications Sampler types AutoCheck Screen design. - PowerPoint PPT PresentationTRANSCRIPT
1Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com
RTC, December 2004
ABL800 FLEXIntroduction
2
Agenda
• Front view• Rear view• Modular design• Parameters• Analyzer
configurations• Specifications• Sampler types• AutoCheck• Screen design
3
Front view
1
2
4
3
7
6
5
1. Aspiration inlet2. Barcode reader 3. Color touch screen4. Printer5. Solutions (cleaning
calibration, rinse and waste containers)
6. AutoCheck7. CD-RW drive8. Window to electrode
modules
5
8
4
Rear view
1. Screen, rear2. Gas containers 3. Communication ports 4. Power switch5. Fan
1
3
2 2
54
5
Communication ports
• The two USB communication ports provide connection to external devices, e.g. network, keyboard, USB storage device
• The two other communication ports provide connection to mouse and keyboard
• Furthermore there is a printer port, a network connector, a serial port and a port for an external CRT VG monitor
2 31
1 USB2 Mouse/keyboard3 Network connections
6
Modular design
• Allows flexibility in parameter availability
1 Inlet2 pH/BG3 Met/Lyt4 Oximetry
2 31 4
7
Parameters
• There are 10 electrode slots in the two electrode modules• One electrode slot for the reference electrode• Nine other electrodes available for the following
parameters:
pHpH, , ppCOCO22, , ppOO22, , ccKK++, , ccNaNa++, , ccCaCa2+2+, , ccClCl–– , , ccGlucoseGlucose, , ccLactateLactate
8
Oximetry parameters
ctHb = concentration of total hemoglobin
sO2 = oxygen saturation %
FO2Hb = fraction of oxyhemoglobin
FCOHb = fraction of carboxyhemoglobin
FHHb = fraction of deoxyhemoglobin
FMetHb = fraction of methemoglobin
FHbF = fraction of fetal hemoglobin
ctBil = concentration of bilirubin
9
Analyzer configuration
BG OXI ctHb/sO2 ctBIL/FHbF LYT MET
835 830 825 820 815 810 805 800
Models ABL835, ABL830 and ABL800 of the ABL800 FLEX analyzers are not available at the time of the release
10
Specifications – analysis details
• Sample volumes Macromodes 195 L (all parameters) Micromodes 35-95 L (all parameters)
• Measuring time Macromodes 80 sec., cycle time 150 sec., approx. 24 samples/hr Micromodes 80-135 sec., cycle time 145-200 sec., approx. 18 samples/hr
• Derived parameters 47 different derived parameters to choose from. See the types and definition in
teh ABL800 FLEX Specification sheet
11
Specifications - communications
• Computer specification Intel Celeron Processor Windows XP embedded
• True multi-tasking system Intel Celeron processor for DMS software Dedicated 80386 CPU for wet section
• Communication LIS/HIS communication based on ASTM and HL7 Network communication – Ethernet (TCP/IP protocol as communication protocol) True two-way communication
12
Customizable
• Very comprehensive setup programs More functions than ever can be customized Examples: operators and passwords, corrective actions, reference and critical
ranges etc.
• Automatic restart after replacements• On-line help systems
Video tutorials Help troubleshooting
• Connection to RADIANCE Especially analyzer remote control module
13
Sampler types
Syringe QC with adapterCapillary tube
Expired air Test tube
14
AutoCheck
• Automated QC measurements • Eliminates user-to-user
variance - results only reflect analyzer performance
• Time-saving• Holds 20 ampoules
15
Color touch screen
• Operation and management of the analyzer are performed via the color touch screen
• The screen is divided into three sections
1. Top section/status bar varies slightly according to the status of the analyzer and setup
2. Center section contains the main information and interaction area
3. Bottom section contains navigation buttons and varies slightly according to the screen in question
1
3
2
1 Top section2 Center section3 Bottom section
16
Top section
• The status bar describes the current task
E.g. calibration, rinse, aspiration The time bar is present when the
analyzer is performing a task
• The parameter bar lists all the measured parameters available and activated
• The traffic light gives an overview of various analyzer activities and the traffic light color shows the overall status of the analyzer – see the “02 What is what” presentation for a further description
1
3
2
1 Status bar2 Parameter bar3 Traffic light
17
Center section
• The center section is the main information and interaction area
• Each screen is identified by an icon and a name that matches the button that gives access to it
• The screen may contain text, check buttons, scroll bars, a screen keypad or screen keyboard
18
Bottom section
• The bottom section changes with the different options, depending on the screen in question
1. In the Ready screen Access various information, e.g. the
current time, next QC, if connected to RADIANCE
The buttons can be selected to give access to e.g. Logon/Log Off, the Menu
2. General navigation buttons “Close” – close actual window “Back” – go one step backwards
3. Other navigation buttons Results, ID, messages, print, etc.
Quality Control Result screen:
1 Main menu2 General navigation buttons3 Other navigation buttons