radiant panels - smartair diffusion · a range of radiant panels are available for countless...

11
A range of radiant panels are available for countless applications. www.price-hvac.com for additional product information, including product videos and brochures. Price Radiant Panels are designed to provide radiant heating and cooling. The superior thermal comfort and high capacity achieved with radiant heating and cooling, as well as the flexibility and customization of the product, makes it suitable for use in almost any application. Radiant Panels RP Series Both linear and modular panels are available Available with smooth finish, perforation, silk-screening and custom paint finishes Customizable for integration into architectural designs Mounting options include free hang, surface and wall mount

Upload: vongoc

Post on 20-Jul-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

A range of radiant panels are available for countless applications.

www.price-hvac.com for additional product information, including product videos and brochures.

Price Radiant Panels are designed to provide radiant heating and cooling. The superior thermal comfort and high capacity achieved with radiant heating and cooling, as well as the flexibility and customization of the product, makes it suitable for use in almost any application.

Radiant PanelsRP Series

Both linear and modular panels are available

Available with smooth finish, perforation, silk-screening and custom paint finishes

Customizable for integration into architectural designs

Mounting options include free hang, surface and wall mount

Page 2: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-51

RP SeriesPriceRadiantPanels,RP,aredesignedtoprovideradiantheatingandcoolingtoazone.Theyaredesignedwithalowprofiletointegrateintoamultitudeofdifferentinstallations,fromstandardsuspended ceiling systems to free hanging applications andsurfacemountedapplicationsonwallsorceilings.Thesuperiorthermalcomfortperformanceandhighcapacityachievedwithradiantpanelsmakethemsuitableforuseinalmostanyapplication.Theyaretypicallyinstalledalongperimeters,corridors,hallwaysandaisleways,orininteriorspaces.RadiantPanelshandlethesensibleportionofabuildingloadandmustbepairedwithanairventilationsystemsuchasFanCoils(SectionF1),Underfloor(SectionI),Displacement(SectionJ),orActiveBeams(SectionL),forventilationandlatentloadremoval.

RPMThestandardPriceModularRadiantPanel,RPM, is suitable for exposedapplication,typicallyinaT-Barceiling.TheRPMcanalsoberecessedorflushmountedonadrywallceiling.Thismodelismostidealforinteriorspacesandgridceilings,thoughtheycanbeusedforperimeterapplicationaswell.Itisalsoavailableinategularfinish.

RPLThe standard Price Linear Radiant Panel,RPL, is suitable for exposedapplication,typicallyinaT-Barceiling.TheRPLcanalsoberecessedorflushmountedonadrywallceiling.Thismodelismostidealforperimeterareasandexcellentforwindowtreatment,thoughtheycanbeusedininteriorspacesaswell.

RPLAThePriceExposedLinearRadiantPanel,RPLA,providesalternatesolutionsforutilizingradiantpanelswhentheceilingspaceisnotavailable,aradiantpanelinstalledorrecessedintotheceilingisnotfeasible,ortheradiantpanelistobeplacedinanareawithhighceilings.Itcanalsobechosentoadddesignelementsintoaspacetoprovidebothapracticalfunctionandaestheticappeal.Threedifferenttypesofmountinginstallationsareavailable:wallmount,surfacemountandfreehang,aswellasavarietyoffinishoptions.

RadiantPanelsRP Series

Cooling

Heating

Panel

Panel

RPM

RPL

RPLA

Product Overview

Page 3: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-67

RadiantPanelsRPM

Models

ModularRadiantPanel RPMThePriceModularRadiantPanel,RPM, isdesigned to integrate intoa standardortegularsuspendedceilingsystemandprovideradiantheatingand/orcoolingtoa zone.

TheRPM featuresheat sinkson thebackofarigidceilingtiletoeffectivelytransferheatfromcoppertubestothepanelface.Additionally,non-hardeningthermalpastebetween the tubingand theheatsink,aswellasbetweentheheatsinkandthepanel,maximizes heat transferwhich increasesperformance.ThesuperiorthermalcomfortachievedwithradiantpanelsmaketheRPMsuitableforuseinalmostanyapplication.

The modular radiant panel can be silkscreenedtosimulateawidevarietyofnon-texturedandminimallytexturedceilingtilepatterns.

Features

• Integratedaluminumheatsinksfor optimalheattransfer• Non-hardeningthermalpastebetween tubingandheatsink,aswellas betweenheatsinkandpanel• Choiceof2facefinishes:smooth, perforated(21%freearea)• Choiceofpanelmaterial: aluminum, steel• Choice of sweat or NPT connections• Choiceofpipesystem:2-or4-pipe, inactivesection,doublesaddle

Options

• Insulation (acousticalorfoilbackedinsulation)• Specialcustomcolorfinishesand silkscreening• Tegularpanel

Construction / Finish

• HeatSinks–ExtrudedAluminum• PanelMaterial–Aluminum or Steel sheet metal• Piping–ASTMB75Copper

• 5/8”OD(1/2”nominal)coppertubes• Finish–StandardWhite(B19)

Product Information

.500 (13) or 1” (25) varies with nom. size

L - 1/4” (6)

W - 1/4” (6)

Dimensional Data - Imperial (inches)

Nom. Size L W2 x 2 24 242 x 4 48 242 x 5 60 242 x 6 72 244 x 4 48 48

Dimensional Data - Metric (mm)

Nom. Size L W2 x 2 600 6002 x 4 1200 6002 x 5 1500 6002 x 6 1800 6004 x 4 1200 1200

RPM

Page 4: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

H-68 All Metric dimensions ( ) are soft conversion. © Copyright Price Industries Limited 2011. Imperial dimensions are converted to metric and rounded to the nearest millimetre.

Aluminum Plaster Frame

Tegular Edge

Mud Frame

Panel Options

Product Options

RadiantPanelsRPM

Finished

Rough

Piping Options

2 Pipe 4 Pipe Inactive Section

Page 5: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-69

Performance Data - Heating-MetricUnits

Performance Data - Heating-ImperialUnits

RadiantPanelsRPM

Panel Dimensions (ft)

# of Passes

Mean Water Temperature (°F)

120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210

2 x 2Even 320 380 440 470 500 540 580 620 660 700 740 780 840 880 920 980 1040 1100 1160

Odd 270 290 320 350 380 410 440 480 520 560 600 640 680 720 770 820 870 925 960

2 x 4Even 640 760 880 940 1000 1080 1160 1240 1320 1400 1480 1560 1680 1760 1840 1960 2080 2200 2320

Odd 540 580 640 700 760 820 880 960 1040 1120 1200 1280 1360 1420 1540 1640 1740 1850 1920

2 x 5 Odd 870 970 1060 1160 1250 1350 1450 1540 1640 1740 1840 1950 2110 2230 2350 2450 2570 2690 2810

4 x 4 Even 1280 1520 1760 1880 2000 2160 2320 2480 2640 2800 2960 2120 3360 3520 3680 3920 4160 4400 4640

Panel Dimensions

(mm)# of

PassesMean Water Temperature (°C)

48.9 51.7 54.4 57.2 60.0 62.8 65.6 68.3 71.1 73.9 76.7 79.4 82.2 85.5 87.8 90.6 93.3 96.1 98.9

600 x 600Even 94 111 129 138 147 158 170 182 194 205 217 229 246 258 270 287 305 323 340

Odd 79 85 94 103 111 120 129 141 152 164 176 188 199 211 226 240 255 271 281

600 x 1200Even 188 222 258 276 294 316 340 364 388 410 434 458 492 516 540 571 610 646 680

Odd 158 170 188 206 222 240 258 282 304 328 352 376 398 422 452 480 510 542 562

600 x 1500 Even 255 284 311 340 367 396 425 452 481 510 540 572 619 654 689 718 754 789 824

500 x 1500 Odd 212 236 258 282 304 328 352 375 400 425 451 477 502 527 549 571 596 621 646

1200 x 1200 Even 376 444 516 552 588 632 680 728 776 820 868 916 984 1032 1080 1148 1220 1292 1360

Outputs expressed in Btu/h*panel and are based on 70°F Room Temperature. Derate 7% for perforated panels.

Outputs expressed in Watts/panel and are based on 21°C Room Temperature. Derate 7% for perforated panels.

Page 6: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

H-70 All Metric dimensions ( ) are soft conversion. © Copyright Price Industries Limited 2011. Imperial dimensions are converted to metric and rounded to the nearest millimetre.

Performance Data -Cooling-ImperialUnits

Room DesignationRoom Air Temperature minus Mean Water Temperature (°F)

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28A

(Interior Room) 17 19 21 22 24 26 28 30 31 33 35 37 39 40 42 44 46 48 49

B (Perimeter) 21 23 25 27 28 30 32 34 36 38 40 42 43 45 47 49 51 53 55

Room DesignationRoom Air Temperature minus Mean Water Temperature (°C)

5.5 6.1 6.7 7.2 7.8 8.3 8.9 9.4 10.0 10.6 11.1 11.7 12.2 12.8 13.3 13.9 14.4 15.0 15.6A

(Interior Room) 54 60 66 69 76 82 88 95 98 104 110 117 123 126 132 139 145 151 155

B (Perimeter) 66 73 79 85 88 95 101 107 114 120 126 132 136 142 148 154 161 167 174

Performance Notes:1. Outputs expressed in Btu/h*square foot of panel.2. Values are based on BSRIA BS3528:1977.3. ASHRAE A138 values are available as per DIN14037 (Heating) and DIN14240 (Cooling).

Performance Notes:1. Outputs expressed in Watts/square meter of panel.2. Values are based on BSRIA BS3528:1977.3. ASHRAE A138 values are available as per DIN14037 (Heating) and DIN14240 (Cooling).

Performance Data - Cooling-MetricUnits

RadiantPanelsRPM

Page 7: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-73

RPLandRPLApanelscomewithtwotofivecrossbraces(basedonlength)forbracingandprovideastructureiftheunitistobehung or suspended. RPLA comes withmountingbracketsthataretobeinstalledtothewallordrywallceiling.RPMpanelsare installedsimilar to lay-in tiles.RPMSpanelsareinstalledbyconnectingthepaneltoangleiron(suppliedbyothers)withthesecurityscrewsandbushings.

RPLandRPLApanelsareconstructedofextrudedaluminumandhaveafemaleandmaleedge.Thefemaleedgeisrequiredtobeinstalledagainst/towardtheexteriorwall.Pleasenotethatallpanelsaremadewitharedlabelindicatingfemaleedge.

When handling the radiant panels, it isrecommendedthatcleanwhiteglovesbeusedtoavoidsmudgingandmarkingtheunit. Hanging or suspended panels areinstalledusing threaded rod, carabineer,hangerwire,wirerope,chainlinkorgripple(by others) as per local building codes.Allradiantpanelsmusthaveatleastonehangerwireoneachcrossbrace.

Anypanelinstalledagainstexteriorwallsshouldhavethefirsttubesuppliednearestthe wall. Connection to the water coil can bemadewithsoftcopper,male/femaleNPTconnection,orwithpush-onconnectors.Use a heat pad between Radiant Panelandcopperpipewhenmakingsolderingconnections.Excessiveheatcandamagethepaintfinish.

When panels require site cutting, use acircularsawwithcarbidetippedblade.Cutwiththefinishsurfacefacingthesawandensureyouprotectthefinishsurfacebeforecuttingbegins.

RadiantPanelsInstallationLinear&Modular

Installation

Female Edge

Radiant Panel Widths and Finished Openeings

Radiant Panel Widths and Finished Openings

Panel Width (in) Fiinished Opening (in) Panel Width (mm) Fiinished Opening (mm)6 6 1/4 154 160

8 1/4 8 1/2 208 21410 10 1/4 256 26212 12 1/4 804 31015 15 1/4 383 389

16 1/8 16 3/8 410 41617 3/4 18 1/8 454 46019 7/8 20 1/8 506 51223 3/4 24 604 61029 5/8 29 7/8 754 76035 1/2 35 3/4 902 908

Crossbrace Quantity

Length 0 - 47 (0 - 1200)

48 - 114 (1221 - 2900)

115 - 162 (2901 - 4112)

163 -192 (4113 - 4885)

Quantity 2 3 4 5

Page 8: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

H-74 All Metric dimensions ( ) are soft conversion. © Copyright Price Industries Limited 2011. Imperial dimensions are converted to metric and rounded to the nearest millimetre.

RadiantPanelsInstallationLinear&Modular

Radiant Panel Height Above Finished Floor/Average Water Temperature. For radiantpanels toperformefficiently,Pricerecommendsthattheaveragewatertemperature used with its panels bebetween110°F[43°C]and190°F[88°C]forceilingheightsupto10ft(3m).

Thistablegivesthede-rationpercentageforceilingheightsexceeding13ft(3900mm).

Aswestartmovingawayfromtheoccupiedzone,theradiativeenergyisabsorbedandequalizedwiththecoolsurfaceshigherupintheceilingarea,reducingtheamountofradiativeenergyremainingbythetimeitreachestheoccupiedzone.Theincreaseinceilingheightalsoreducestheviewfactoroftheradiantpaneltothepeopleintheroom.Thus,ade-rationfactormustbeaccountedforwhenmountingpanelsathighceilingheights.

PanelhandingisrequiredwhenorderingRPL, RPLA, RPM (odd pass), and RPMS(oddpass).ForRPLandRPLA,orientationistakenwithrespecttolookingatthewalloranimaginarywallanddeterminingwhichendthesupplyislocatedon.

RPLandRPLAareconstructedofextrudedaluminumpanelsthathaveafemaleandmaleedge.Thefemaleedgeforacastellatedfinish is required tobe installedagainst/toward theexteriorwall inorder tohidetheseamthatiscreatedwhentheplanksare assembled together. RPL andRPLApanelscomewitharedlabelindicatortoshowwhichsideisthefemaleedge.

Anypanelinstalledagainstexteriorwallsshouldhavethefirsttubesuppliednearestthewall.Theinitialtemperaturedifferencebetweenthefirstpassofthepanelandthecoldersurfaceislargest.Thetemperaturedifferencebetweenthepanelandroomwillbecomemoreuniformasitmovestowardtheinterior.Imagesontheleftshowleft-handed even and odd pass panels withsupplyconnectionlocatedontheleftside,closesttothewall.Imagesontherightshowright-handedevenandoddpasspanelswithsupplyconnectionlocatedontherightside,closest to the wall.

ForoddpassRPMandRPMS, the imageontheleftshowsaleft-handedpanelwithsupplyconnectionlocatedinthetopleft,andtheimageontherightshowsright-handedpanelwithsupplyconnectionlocatedinthetopright.

Pipinglayoutisavailableineither2or4pipeconfiguration.Allconnectionsare½”nom.coppersweat,maleNPTorfemaleNPT.

Ceiling Height De-ration Data

Panel Handing / Coil Connection

Panel Height A.F.F. ft (mm) De-ration %

14 (4200) 3

15 (4500) 6

16 (4800) 9

17 (5100) 12

18 (5400) 15

19 (5700) 18

20 (6000) 21

Female Edge

RPL, RPLA

RPM, RPMS

Left Handing Right Handing

Supply

Return

Supply

Supply

Return

Return Return

Supply

L - Left (Even Pass: supply and return are located on left-hand side) (Odd Pass: supply is located on left-hand side, closest to wall)

R - Right (Even Pass: supply and return are located on right-hand side) (Odd Pass: supply is located on right-hand side, closest to wall)

Page 9: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-75

Installation - ModularPanelinT-BarCeiling

RadiantPanelsInstallationRPMSeries

Page 10: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

© Copyright Price Industries Limited 2011. All Metric dimensions ( ) are soft conversion. Imperial dimensions are converted to metric and rounded to the nearest millimetre. H-109

Radiant Panels

SECTION 23 82 43 – RADIANT PANELS

PART 1 – GENERAL1.1 Summary

A. Thissectionincludesthefollowing:

1. RadiantPanels

1.2 Related DocumentsA. 230100–OperationandMaintenanceofHVACSystems

B. 230500–CommonWorkResultsforHVAC

C. 230900–InstrumentationandControlforHVAC

D. 232000–HVACPipingandPumps

E. 233000–HVACAirDistribution

1.3 SubmittalsA. ProductData:Foreachtypeofproductindicated,include

ratedcapacities,furnishedspecialties,andaccessories.

B. Shop Drawings: Detail equipment assemblies andindicateddimensions,requiredclearances,methodoffieldassembly,components,andlocationsandsizeofeachfieldconnection.

1. Includeascheduleshowinguniquemodeldesignation,room location, model number, size, and accessories furnished.

2.WiringDiagrams:Power,signal,andcontrolwiring.

C. CoordinationDrawings:Reflected ceilingplans,drawnto scale, onwhich the following itemsare shownandcoordinatedwitheachother,basedoninputfrominstallersoftheitemsinvolved:

1. Ceilingsuspensionassemblymembers.

2.Methodofattachinghangerstobuildingstructure.

3.Size&locationofinitialaccessmodulesforacousticaltile.

4 Ceiling-mounted items including lighting fixtures,diffusers,grilles,speakers,sprinklers,accesspanels,andspecialmoldings.

D. OperationandMaintenanceData:Forradiantpanels,tobeincludedinemergency,operationandmaintenancemanuals.

1.4 Quality AssuranceA. ProductOptions:Drawingsindicatingsize,profiles,and

dimensionalrequirementsofradiantpanelsandarebasedonthespecificsystemindicated.

B. ElectricalComponents,DevicesandAccessories:ListedandlabeledasdefinedinNFPA70,Article100,byatestingagencyacceptabletoauthoritieshavingjurisdiction,andmarkedforintendeduse.

C. Radiantpanelsandaccessoriesshallberatedandtestedforpressureasshownonthedrawings.

1.5 CoordinationA. Coordinatelayoutandinstallationofradiantpanelsand

suspensionsystemwithotherconstructionthatpenetratesceilingsorissupportedbythem,includinglightfixtures,HVACequipment,fire-suppressionsystem,andpartitionassemblies.

PART 2 – PRODUCTS2.1 Manufacturers

A. InPart2articleswhere titlesbelowintroduce lists, thefollowingrequirementsapplytoselection:

1.Manufacturers:Subjecttocompliancewithrequirements,provideproductsbyoneofthemanufacturersspecified.

2.2 Modular Radiant PanelsA. ApprovedManufacturers:

1. Price

2.Alternates:Alternatesorapprovedequalsareacceptableifandonlyifamock-upandwitnesstestisperformedtodemonstratethatthesubstitutionmeetsdesigncriteria.

B. Modularradiantpanelsshalluseheatsinksonthebackofarigidceilingtiletotransferheatbetweencoppertubesandthepanelface.Themodularradiantpanelsaretoradiateor absorb heat from or to the zone below.

C. WaterTubes:TubesshallconsistofASTMB75½”nominalcoppertubing.Waterconnectionsshallbeoneendonly.Waterconnectionsshallbesuitableforsolder,compressionfittings,push-onfittingsorthreadedconnection.

D. HeatSinks:Heatsinksshallbeextrudedaluminumandcopperpipewillbemechanicallyfastenedtotheheatsink.Anon-hardeningheattransferpasteisrequiredbetweenthetubingandtheheatsinkandbetweentheheatsinkandthepanel.

E. Face:Thepanelfaceshallbeconstructedof18or14ga.aluminum

F. Paint Finish:All visible components shall be powder-coatedwithhighlyemissivepowdercoatpolyesterpaintforoptimalradiativepropertiesaswellasdurabilityandeasycleaning.ManufacturershallprovidewaterpressuredropdataaswellasheatandcooloutputdataderivedfromtestsinaccordancewithDIN14037(heating)andDIN14240(cooling).

G.StandardColorProtechPX622W457.

H.ModularradiantpanelcapacityshallbetestedandcertifiedbymanufacturerinaccordancewithDIN14037(heating)andDIN14240(cooling)tomeettheperformancelistedontheschedule.Shouldanyperformancerating,chilledwatersupplytemperature,waterpressuredrop,etc.deviatefromtheschedule,manufacturershallsubmitupdatedcapacityas described in Section 1.3, aswell as computationalfluiddynamicmodelingdemonstratingthatanychangesdonotimpacttheairdistributioninaroomthatwouldcauseadetrimenttothePMVandADPIratingfromthedesignconditions.Manufacturershallhavefactorytestingfacilityavailabletoperformperformancetestofunitsinaccordancewithsaidstandard,asrequired.Uponrequest,upto1%ofunitsfortheprojectcanbetestedinaccordancewiththestandard.Requestwillbemadewithorderandpriortoshipmentofchilledsails.Engineerwillhavetheoptionofwitnessingthistest.

I. Water connections shall be shipped sealed to limitthe introduction of dust and dirt during shipping andconstruction.

J. Accessories:

1.Manufacturershallsupplyuponrequest12”/18”stainlesssteelbraidedhosewithisolationballvalvesasrequired.

2.3 Linear Radiant PanelsA. ApprovedManufacturers:

1. Price

2.Alternates:Alternatesorapprovedequalsareacceptable ifandonlyifamock-upandwitnesstestisperformedtodemonstratethatthesubstitutionmeetsdesigncriteria.

RadiantProductsSuggested Specifications

Page 11: Radiant Panels - Smartair Diffusion · A range of radiant panels are available for countless applications. for additional product information, including product videos and brochures

RA

DIA

NT

PR

OD

UC

TS

H-110 All Metric dimensions ( ) are soft conversion. © Copyright Price Industries Limited 2011. Imperial dimensions are converted to metric and rounded to the nearest millimetre.

Radiant Panels

RadiantProductsSuggested Specifications

B. Linearradiantpanelsshalluseextrudedaluminumwithintegratedheatsinksonthebacktotransferheatbetweencoppertubesandthepanelface.Thelinearradiantpanelis to radiate or absorb heat from or to the zone below.

C. WaterTubes:TubesshallconsistofASTMB75½”nominalcoppertubing.Waterconnectionsshallbeoneendonly.Waterconnectionsshallbesuitableforsolder,compressionfittings,push-onfittingsorthreadedconnection.

D. HeatSinks:Heatsinksshallbeextrudedaluminumandcopperpipewillbemechanicallyfastenedtotheheatsink.Anon-hardeningheattransferpasteisrequiredbetweenthetubingandtheheatsink.

E. ExtrudedAluminumPlank:Thepanelshallbeconstructedof1.2mmthickextrudedaluminum

F. Paint Finish:All visible components shall be powder-coatedwithhighlyemissivepowdercoatpolyesterpaintforoptimalradiativepropertiesaswellasdurabilityandeasycleaning.ManufacturershallprovidewaterpressuredropdataaswellasheatandcooloutputdataderivedfromtestsinaccordancewithDIN14037(heating)andDIN14240(cooling).

G.StandardColorProtechPX622W457.

H. LinearradiantpanelcapacityshallbetestedandcertifiedbymanufacturerinaccordancewithDIN14037(heating)andDIN14240(cooling)tomeettheperformancelistedontheschedule.Shouldanyperformancerating,chilledwatersupplytemperature,waterpressuredrop,etc.deviatefromtheschedule,manufacturershallsubmitupdatedcapacityas described in Section 1.3, aswell as computationalfluiddynamicmodelingdemonstratingthatanychangesdonotimpacttheairdistributioninaroomthatwouldcauseadetrimenttothePMVandADPIratingfromthedesignconditions.Manufacturershallhavefactorytestingfacilityavailabletoperformperformancetestofunitsinaccordancewithsaidstandard,asrequired.Uponrequest,upto1%ofunitsfortheprojectcanbetestedinaccordancewiththestandard.Requestwillbemadewithorderandpriortoshipmentofchilledsails.Engineerwillhavetheoptionofwitnessingthistest.

I. Water connections shall be shipped sealed to limitthe introduction of dust and dirt during shipping andconstruction.

J. Accessories:

1.Manufacturershallsupplyuponrequest12”/18”stainlesssteelbraidedhosewithisolationballvalvesasrequired.

2.4 Source Quality ControlA. Identification:Labeleachradiantpanelwithappropriate

tagnumber.

B. Verification of Performance: Rate radiant panels inaccordancewithDIN14037forheatingorDIN14240forcooling.

PART 3 – EXECUTION3.1 Pre-Design Services

A. BidshallincludethecoststocompletefinalselectionsandcoordinationwiththeEngineerat theEngineersoffice.Allowforaminimumofthree(3)days.

3.2 Installation – GeneralA. Installradiantpanellevelandplumb.Maintainsufficient

clearance for normal services, maintenance, or inaccordancewithconstructiondrawings.

B. Complete installation and startup checks according tomanufacturer’s written instructions and perform thefollowing:

1. Verifythatcontrolsandcontrolenclosureareaccessible.

2.Verifythatcontrolconnectionsarecompletetocontrolvalvesasneeded.

3.Verifythatanyidentificationtagsarevisible.

4.Verifythatcontrolsrespondtoinputsasspecified.

3.3 ConnectionsA. Piping installation requirements are specified in other

Division 23 Sections. Drawings indicated generalarrangementofpiping,fittings,andspecialties.

B. Installpipingadjacenttoradiantpanelstoallowforserviceand maintenance.

C. InadditiontoDivision23Section“HydronicPiping”,connectcoppertubingtosupplywithshut-offvalve,strainer,controlvalve,andunionorflange,andtoreturnwithbalancingvalveandunionorflange.

D. ConnectwiringaccordingtoDivision26Section“Low-VoltageElectricalPowerConductorsandCables”.

E. Tightenelectricalconnectorsandterminalsaccordingtomanufacturer’spublishedtorque-tightening.

3.4 Field Quality ControlA. Perform the following field tests and inspections and

preparetestreports:

1. LeakTest:Afterinstallation,fillwatertubesandtestforleaks.Repairleaksandretestuntilnoleaksexist.

2.OperationalTest: After electrical circuitry has beenenergized,startunitstoconformtoproperunitoperation.

3.Testandadjustcontrolsandsafeties.Replacedamagedandmalfunctioningcontrolsandequipment.

B. Manufacturer’sFieldService:Engageafactory-authorizedservicerepresentativeto inspect, test,andadjustfield-assembled components and equipment installation,includingconnections,andtoassistinfieldtesting.Reportanyfindingsinwriting.

C. Removeandreplacemalfunctioningunitsandretestasspecifiedabove.

3.5 Cleaning and ProtectionA. Cleanallvisiblesurfacesofequipment;touchupasrequired.

B. Protect all units before, during and after installation.Damagedmaterialsduetoimproperprotectionshallbecause for rejection.

3.6 Construction Phase ServicesA. Installershallvisit theradiantpanelfactory,orfactory-

authorizedrepresentative,priortothearrivaloftheproductonsite,tobecomefamiliarwiththepanels.Manufacturershallincludethecostofsuchavisitforone(1)installerinthe bid.

B. Manufacturerorfactory-authorizedrepresentativeshallvisitthesiteregularlyduringtheinstallationprocesstoensurepropermeansandmethodsarebeingemployed.Bidshallincludethecostofaminimumoftwo(2)suchvisits.

C. Manufacturerorfactory-authorizedrepresentativeshallprovide start-up and training services to owners/staffto adjust, operate, andmaintain radiant panels. Referto Division 01 Section “Demonstration andTraining”.Aminimumofeight(8)hoursofsuchservicesshallbeincluded in bid.