r-type fire alarm system - ホーチキ株式会社 · versatile gr-type fire alarm system...

10
Equipped with Automatic Test Function HRK-TYPE GR-TYPE CONTROL PANEL R-TYPE FIRE ALARM SYSTEM R-TYPE FIRE ALARM SYSTEM We are concerned with "Basic Functions" Small • Medium Scale GR-Type Control Panel

Upload: others

Post on 27-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

Equipped withAutomatic Test

Function

HRK-TYPE

GR-TYPECONTROL PANEL

R-TYPE FIREALARM SYSTEM

R-TYPE FIREALARM SYSTEM

Weare

concernedwith

"BasicFunctions"

Small • Medium ScaleGR-Type Control Panel

Page 2: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

1

HRK

1

It provides security for office buildings, apartments, mansions,hotels, departmental stores, hospitals, schools and factories.It has thoroughly explored the fundamental functions of the R-typesystem. More buildings than ever are installed with the R-type FireAlarm system.

Addresses Addresses

Compatible with

Versatile GR-type Fire Alarmsystem (capacity: about 5,000m2

~ 70,000m2)2 types: wall-mounted andfreestanding 8 modelsSimple applicability andoperabilityLow-cost and automatic testfunction-equippedClear LCD and warning alertComform to new specificationfor public addressStandard installation withsmoke control • gas leakagewarning functionConnect up to 39 units of R-type display panel (can connectup to 15 units of annuciators)Enhanced function for signaltransfer at serial port.

Handles 2 system 254 addresses ~16 system 2032 system (1 system 127 addresses)

Highly versatileConnectable with annuciator

Standard installation with monthly log function • Flexible transmission

Standard installation with fire alarm function and analog monitor function

Page 3: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

2

Total extension distance: system km

Comfortable Multiple System MethodComfortable Multiple System Method

R-type

Making

full

use

of

the

basic

functions

of

the

system

The R-type system ofHOCHIKI is not easilyaffected by the noiseinterference generated bymobile phones

Positioning R-type System

Dispersedtype

Centralisedtype

MULTIPLE SYSTEM METHOD(1 SYSTEM 127 ADDRESSES)If the transmission route for the R-type FireAlarm system uses a single system, a singlefailure may affect the entire system. Thus,based on the risk diversification philosophy,HOCHIKI incorporated a multiple-systemdesign, which reduces the impact on thesystem to its minimum should a failure occurs.

TOTAL EXTENSION DISTANCE :2.4KMTo monitor scattered buildings at a site, suchas a factory, for instance, the transmissiondistance will be insufficient on the singlesystem method and multiple control panelsbecome necessary. With the multiple systemdesigned by HOCHIKI, however, a singlesystem can accommodate 2.4km of totalextension distance. Thus, a single unit of thecontrol panel can handle all the monitoringactivities. This method provides much moreroom than the single system method.

HRF III

HRH

HRK

HRG II

HRJ

HRJ

P

No. of addresses (No. of lines) 254 508 762(1,016) 2,032 16,000

Intergrated Control Panel

Analog

GR

-type

Addressable A

nalog Function

Fire Alarm

& Sm

oke Control

PanelFire A

larm C

ontrol PanelR-type

Signal systemR-type Central Panel

Multiple system

Each system

R-type system (single system method)

R-type system (multiple system method)

1 unit of control panel

Insecure Ease ofmind

Relia-bility

Appli-cabi-lity

Cost-efficient

HRK

Page 4: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

HRK

3

Low-cost, clear displayand user-friendy. Thedisplay and operationarea features easilydistinguishable design,colors and big buttonsfor easy operation.“User-friendliness” isthe key idea here.

Display and operation functionsconcentrated in the

L350mm x W420mmWide display and operation area

The reliable

Dual check functionStandard installation (automatic testfunction + self-diagnosis function)

Besides the automatic test function required by the Japan FireService Law, implemented via the use of the automatic testfunction-equipped detector, its standard installation includesthe unique self-diagnosis function which executes “ detectoroperation test”, “detector contamination test” and “standbypower test”. It cuts back on the running cost required bycontrol and operation as well as improves the reliability.

Easy monitoring and control bymeans of

Detector data(analog value)

Log functionstandard installation

Equipped with monthly loggingfunction for automatic testfunction-equipped detector data(analog value). When necessary,analog values of up to a monthcan be generated for displayand printing. A more accuratecontrol and operation (detailedknowledge of indoor environment condition) is achieved withlower unwanted alarm and appropriate sensitivity check.

VARIOUS WARNING DISPLAY

ANALOG MONITOR

WARNING DISPLAY

Page 5: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

4

The user-friendliness of the R-typesystem taken into consideration.

Flexible system building

Multi-line modulesand monitormodules

The system’s flexible setupallows various combinations ofterminal devices via the use ofvarious modules. For example,to install a conventionaldetector or connect anIntruder detection sensor, usethe multi-line modules ormonitor modules which allowsthe connection of 1 addressand 4 lines. This arrangementprovides the building with adelicate system.

A wide scope of uses

Used for various purposes5 display lamps

The standard installation includes 5 display lamps whichcan display the fire hydrant, sprinkler, smoke controland air-condition, etc., individually. The condition ofthe equipment to bemonitored can beconstantly displayedwithout switching over tothe LCD. Direct input can beexecuted from the contact orinput can be executed from therelay.

Easy to understand

5.6 inch LCD

With the bright back-lit screen, the display is highlyvisible and easy to undestand. 16 characters of“English, numeric, Kana, Kanji” or 13 characters+ line number are adopted forthe message display. Theseparate function furthersplits the screen into upperand lower part for fastchecking and operation.

Conform to current needs

Conform to the newspecification forPublic AddressStandard installation

This system conforms to the newJapanese public address standardsuch as the signal transfer for fireverification (2nd fire alarm • ManualCall Point • fire identification).

Early detection of fire

Pre-Alarm functionStandard installation

Aggressive adoption of handyfunctions

Built-in printerwhich records systemoperation data

This function is handy as it recordsand prints detail data for eachoperation, including fire alarm,operation records of automatic testresult, and manual inspection. It isuseful for control and operation.

Design with theadministrator in mind

Illustratedoperation display

This system also conforms to the evaluationcriteria for the comprehensive control panel(operation console). It is further integratedwith the CRT display and can be used fordetailed management of equipmentinformation for the entire building.

Easy to understand

Compatible with thelatest comprehensivecontrol panel.

Easily understood illustrations are usedfor daily operations as well as emergency.The adminstrator needs not panic in anemergency.

The pre-alarm functionconstantly monitors thesignals received from theanalog function-equippeddetector. It issues warning(pre-alarm) before thesituation develops into afire.

Multi-line modules

Smoke detector x 17

Heat detector x 30 ormore

x 4 lines

* Screen Display may differ according to the version of the system.

Page 6: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

5

AddressableManual Call

Point

Photoelectricbeam

type detector

Fixed-temperature

spot-typedetector

Rate of Risespot-typedetector

Photoelectricspot-typedetector

Fire monitormodule

Map • lamp display

Annuciator

R-type display panel+ annuciatorUp to 39 units

Bell module

Gas leakage module

Standard contactmonitor module

Smoke control module

RS-485 x 1 chR-type display panel

Fire monitor module1 system 127addresses Upto 16 systems2032 addresses

RS-232 x 2 ch

HRK control panel

CRT system

Centralised monitorpanel, etc.

PC (data setup etc.) Addressprogrammer

: Automatic test function device

HRK

Page 7: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

6

The system handles differenttypes, scales, purposes anduses of building with ease.

This system provides flexible setup using moduleswhich matches the types of equipment information,such as automatic fire alarm, gas leakage, SmokeControl and general monitor equipment, etc., andallows flexible combination of connection withterminals. When combined with other facilities, itprovides the base for building a complete Fire Alarmenvironment which caters to the specific conditionsof buildings.

The system is useful for buildings of various scalesand uses, include areas where an indefinite numberof guests may visit, staff areas and parking spaces,etc. It helps to minimize confusion, which may ariseduring a fire, by its interlocked operations, such asthe administrator emergency guidance feature andsmoke control devices, etc.

This system caters to various types of buildingenvironment, uses and management systems (madepossible via the automatic test function using devicessuch as indoor detectors which operate when theoccupants are not around), such as the location andscale of buildings from a single block of high-risemansion to multiple-block apartments. It is a FireAlarm system designed with cost-effectiveness inmind.

The automatic test function allows the heat andsmoke tests to be omitted during the inspection,which allows a more comfortable environment forpatients. In addition, R-type display panel, whichprovides identification information on locations faraway from the control room, and annuciators, whichdisplay maps or lamps, can be installed in the nursecentres on every floor. As such, every floor will havea monitor system which runs 24-hours a day.

With the combined use of multi-signal detectorsand fire monitor modules, etc., a flexible monitorsystem can be built for guest rooms and publicrooms, etc. The privacy of your guests will bemaintained with the use of the automatic testfunction.

In the case of schools and factories, where variousfacilities are scattered around in the estates, acomfortably wide area monitor system can beconstructed with the R-type system characterisedby the multiple-system method, or the single-systemmethod characterised by its extension distance of2.4km/ system. It can also incorporate a centralisedcontrol using the CRT system.

Office Building •Tenant Building

Mansion •Apartment

Departmental Store• Shopping Centres

Hospital • Research Institute

School • FactoryHotel •Resort

Page 8: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

7

2000

600450

1100

550160

WALL-MOUNTED TYPE

Flexible system configuration,with free incorporation of

variable modules that are...

(Unit : mm)

FREESTANDING TYPE

(Unit : mm)

Type Product code No. of No. of Capacity of External dimension Weightsystem address standby W x H x D kg

powerHRK- 2 254 3.5AH Approx.

ACW254FGA 34Wall HRK- 4 508 550 x 1100 x 160 Approx.

mounted ACW508FGA 38type HRK- 8 1016 6.0AH Approx.

ACW1016FGA 40HRK- 8 1016 6.0AH Approx.

Free- ACS1016FGA 127standing HRK- 12 1524 600 x 2000 x 450 Approx.

type ACS1524FGA 10.0AH 133HRK- 16 2032 Approx.

ACS2032FGA 135

Type GR-type Control Panel (Time Delay) with automatictest function

Product code HRK-ACW FGA HRK-ACS FGA(Wall-mounted type) (Freestanding type)

Main Power AC 220V 50/60HzPower consumption Maximum 6AStandby power DC24V Nickel Cadmium batteryNo. of main lines System line : HP 1.2-4C/system

Control line : HP 1.2-10PTransmission Polling • selecting (with interrupt function)systemLength of main Total extension distance 2.4kmsignal line Max distance 1.56km/systemAllowable line Main signal line : 30ΩresistanceDisplay Digital display LED 7 segment display

Fire : 6 digits x 2 windowsGas leakage : 6 digits x 2 windows

Message display Back-lit LCD (5.6 inch)Message : 16 characters or 13characters + lines number(JIS 1” and 2nd level Kanji)

Operation Section Menu, keypad, switchesRecord Built-in printerSignal transfer Various representative signal transfer : 10

Individual signal transfer : 15 (in-board : up to 60 points<option>)Serial port signal transfer : RS-232C (2 ch)

RS-485 (1 ch)Nominal time delay 50 seconds (smoke detector : 50 seconds;

heat detector : 20 seconds)Gas leakage time 40 secondsdelayMain sound • Synthetic sound, electronic sound and buzzerfailure soundMaterial Steel plate (1.6mm thick) baking paintColor Door, main set, : color closed to Munsell value :

2.5Y9/1 (100% glossy available)Operation, display panel : color closed to Munsell value5Y6/0.5 (30% glossy available)

Page 9: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

8

PHOTOELECTRIC SPOT-TYPESMOKE DETECTOR (multi- signal)

...compatible with the variousinformation needs.

RATE OF RISE SPOT-TYPEHEAT DETECTOR

FIXED-TEMPERATURE SPOT-TYPEHEAT DETECTOR

MODULE

* Fire monitor modules (CHT-K4)

R-TYPE DISPLAY PANEL

Product code HEX-1PETransmission Up to 1km (from control panel)distanceDisplay Back-lit LCDAlarm Buzzer (option : synthetic sound)External (W) 300 x (H) 380 x (D) 70mmdimensionWeight Approx. 6kg (including battery)

SYSTEM DEVICES

Product name (type) Productcode

Fire monitor 4 lines CHT-K4

1 line CHP-KL

Gas leakage 4 lines CHT-G4

Standard 4 lines CHT-S4

contact monitor

Smoke Control 4 lines CHT-R4

(without

reset)

2 lines CHT-D2

(with reset)

Bell (with auto- 1 line CHT-BY

test function)

Addressable PRF-1

manual call point

R-type display HEX-1PE

panel

Annuciator * main units HEX-1PD

* Power, input/output and display units arerequired separately.

M Please refer to Hochik i main productcatalogue for exact requirement.

Modules

Manualcall point

DisplayPanel

Product code ALG-123LYRated power DC 39.5V 30mA

Product code ASA-2RLYRated power DC 26V 30mA

Product code ATG-TA60LYRated power DC 26V 30mA

SERVICE DEVICES

Product name Product code

Photoelectricspot-type smoke ALG-123LY

detector (multi-signal)

Photoelectricbeam-type smoke ABB-12Y

detector (dual-signal)

Rate of risespot-type ASA-2RLY

heat detector

Fixed-Temperaturespot-type ATG-TA60LY

heat detector

Photoelectricspot-type SLR-M

smoke detector

Ionisationspot-type SIJ-M

smoke detector

Fixed-Temperaturespot-type DFJ-M

heat detector

Combinedspot-type DCD-M

heat detector

Rate of risespot-type DSC-M

heat detector

Aut

o-te

st fu

nctio

neq

uipp

ed d

etec

tor

(with

ana

log

func

tion)

Purpose Fire monitor Leakage Standard contact Smoke control Bell

monitor monitor control

Product CHT-K4 CHT-G4 CHT-S4 CHT-R4 CHT-D2 CHT-BY

Current 620µA 270µA Contact a:320µA 280µA 220µA

consumption Contact b:680µA

Applicable wire ø0.8mm ~ ø1.6mm (single line)

Temperature -10˚C ~ 50˚C (for indoor)

range

Material Self-extinguish resin

Color Grey

External (W) 30 x (H) 200 x (D) 72mm

dimension

Weight Approx. 160g Approx. 140g Approx. 140g Approx. 170g Approx. 140g

Con

vent

iona

l Det

ecto

r

Page 10: R-TYPE FIRE ALARM SYSTEM - ホーチキ株式会社 · Versatile GR-type Fire Alarm system (capacity: about 5,000m2 ~ 70,000m2) 2 types: wall-mounted and freestanding 8 models Simple

HOCHIKI CORPORATIONHEAD OFFICE2-10-43, Kamiosaki,Shinagawa-ku,Tokyo 141-8660, JAPANTelephone : 81-3-3444-4116Facsimile : 81-3-3444-4167

SINGAPOREBRANCH OFFICE629 Aljunied Road, #03-16Cititech Industrial BuildingSingapore 389838Telephone : 65-6841-9728Facsimile : 65-6841-9781Email : [email protected]

HOCHIKI AMERICA CORPORATIONTelephone : 1-714-898-0795Facsimile : 1-714-892-2809

HOCHIKI EUROPE (U.K.) LIMITEDTelephone : 44-1634-260133Facsimile : 44-1634-260132