![Page 1: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/1.jpg)
R. S. KULKARNIHVACR CONSULTING ENGINEERSEST. 1981
COMPANY PROFILE
![Page 2: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/2.jpg)
INTRODUCTION
R.S.Kulkarni HVACR Consultancy organization was established in 1981 and has been merged into R.S. KULKARNI HVACR Consulting Engineers. We work as a Consultant for Heating, Ventilation and Air Conditioning design. We provide ancillary services including CFD analysis, smoke analysis, IES simulations, building evacuations and pressurization.
We also undertake MEP co-ordination with renowned design consultants from PHE/FF and Electrical field.
Meticulous Engineering and Strong Work Ethic with a focus on Customer Satisfaction is our Proficiency.
![Page 3: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/3.jpg)
PRINCIPAL CONSULTANT
MR. R. S. KULKARNI
◼ BACHELOR OF ENGINEERING (MECHANICAL) IN 1969
FROM WALCHAND COLLEGE OF ENGINEERING.
◼ MASTER OF TECHNOLOGY (REFRIGERATION &
AIRCONDITIONING) IN 1971 FROM IIT, MUMBAI.
◼ FELLOW AND LIFE MEMBER OF ASHRAE
◼ OPERATING AS INDEPENDENT CONSULTANT SINCE 1981.
◼ PAPER PUBLISHED: THESIS ON EVAPORATIVE COOLING
FOR M.TECH
![Page 4: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/4.jpg)
TEAM STRUCTURE
![Page 5: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/5.jpg)
CONTACTING US
R.S. KULKARNI HVACR CONSULTING ENGINEERSOFFICE NO. 512 + 513, SIDDHARTH TOWER, SANGAM PRESS ROAD, KOTHRUD, PUNE – 411 029
+91–020–41315512/13/14/15
www.rskhvacr.com
![Page 6: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/6.jpg)
AREAS OF CONSULTANCY
✓ HEATING
✓ VENTILATION
✓ AIR COOLING
✓ HYBRID / INNOVATING
COOLING SYSTEMS
✓ AIR CONDITIONING
✓ PRECOOLING
✓ ENGINE TEST FACILITIES
✓ HIGH PRECISION AIR
CONDITIONING SYSTEMS
✓ BUILDING AUTOMATION
SYSTEMS
✓ CFD ANALYSIS FOR CAR
PARKS AND OTHER
COMFORT APPLICATIONS
✓ PRESSURIZATION SYSTEMS
✓ SMOKE VENTILATION
✓ BUILDING EVACUATION
ANALYSIS
![Page 7: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/7.jpg)
TYPES OF PROJECTS
COMMERCIAL BUILDINGS
HEALTHCARE FACILITIES
RESIDENTIAL TOWNSHIPS
BUNGLOWS & HOTELS
IT INFRA-STRUCTURE
PHARMA-CEUTICAL
CLEANROOMSINDUSTRIAL FACILITIES
INSTITUTES & AUDITORIUMS
LEED CERTIFIED BUILDINGS
WAREHOUSESENGINE TEST FACILITIES
![Page 8: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/8.jpg)
ASSOCIATED ARCHITECTS | BUILDERS
![Page 9: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/9.jpg)
RENOWNED CLIENTS
![Page 10: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/10.jpg)
RENOWNED CLIENTS
![Page 11: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/11.jpg)
RENOWNED CLIENTS
![Page 12: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/12.jpg)
RENOWNED CLIENTS
![Page 13: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/13.jpg)
WHY CHOOSE US?
DETAILED LOAD ANALYSIS USING CARRIER HOURLY ANALYSIS PROGRAM (HAP) FOLLOWED BY LIFE CYCLE COSTING FOR ALTERNATIVE SYSTEM CHOICES
SELECTION OF BEST SUITED SYSTEMS WITH FOCUS ON ENERGY EFFICIENCY, INDOOR AIR QUALITY, COST EFFECTIVENESS, OCCUPANT COMFORT, EASE OF OPERATION, MAINTENANCE AND SERVICEABILITY
COMPREHENSIVE DRAWINGS AND TECHNICAL SPECIFICATIONS. USE OF LATEST TECHNOLOGY & CONTROL SYSTEMS TO INTEGRATE WITH BUILDING MANAGEMENT SYSTEMS
![Page 14: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/14.jpg)
NEED MORE REASONS?
UNBAISED TECHNICAL EXPERTISE, STRONG WORK ETHIC, 38 YEARS OF EXPERIENCE, VERSATILE CONSULTANCY AND ENGINEERING TEAM, GREAT CLIENT RELATIONSHIPS AND EFFICIENT TIME MANAGEMENT SKILLS.
DIFFERENTIAL SERVICES: COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS, BUILDING EVACUATION ANALYSIS, SMOKE ANALYSIS, BUILDING AND STAIRWELL PRESSURIZATION, BUILDING ENERGY SIMULATIONS, AND MORE.
![Page 15: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/15.jpg)
MAJOR EXCELLENCE AWARDS
2008 EMERSON
CUP “GOLD AWARD
KBL GREEN BUILDING PLATINUM
AWARD
LIFETIME CONTRIBUTION
IN: “ENERGY SAVINGS &
ENGINEERING CONSULTANCY
NALCO LAB DESIGN
![Page 16: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/16.jpg)
CUTTING-EDGE SOFTWARE:
❑ Carrier Hourly Analysis Program (HAP)
❑ Autodesk AutoCAD
❑ Autodesk Revit- BIM
❑ IES VE- Building Simulation
❑ Cradle- SE Stream CFD Analysis
❑ PyroSim- Smoke Analysis
❑ Pathfinder- Evacuation Analysis
❑ SFPiping- Pressure Drop
❑ PIPEFLOW- Pipe Flow Analysis
❑ NIST Contam- Building Pressurization
![Page 17: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/17.jpg)
CFD ANALYSIS❑ Computational Fluid Dynamics simulation
helps accurately visualize flow velocity, density,
thermal impact and chemical concentrations.
❑ Simulating fluid flows helps analyze HVAC
performance at design stage, ensuring that
critical problems areas are preempted.
❑ Suitable location and quantity of supply, return &
exhaust outlets can be identified. Temp and flow
rate of supplied air can be optimized to meet and
validate design criteria.
❑ Verification of smoke systems, displacement
ventilation systems, natural ventilation systems,
and raised floor systems. Modification and
improvement of malfunctioning HVAC systems.
![Page 18: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/18.jpg)
SMOKE ANALYSIS
❑ Our Smoke Analysis offerings using simulation
software, enables Architects and Structural
Engineers to evaluate airflow profile.
❑ Enables us to suggest structural improvements
as well as better design in terms of controlled
airflow patterns.
❑ Dead air pockets, throw of jet fans and air
velocities can be estimated with the help of the
simulation.
❑ Smoke concentration data, visibility study, fire
and smoke propagation pathway, temperature
and velocity profile are the major deliverables
from our smoke analysis.
![Page 19: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/19.jpg)
IES SIMULATION❑ Our IES Virtual Environment program allows for
fast and accurate thermal simulation.
❑ It provides data on building performance and
helps preempt problems by optimizing design
requirements.
❑ Through energy modelling, we can demonstrate
compliance, or predict energy consumption.
❑ Energy simulation with alternative building
configurations and designs. Helps determine
configuration for lowest capital and energy cost..
❑ Our IES simulation helps architects design more
energy efficient buildings, with improved
performance and occupant comfort while
minimizing capital and running costs.
![Page 20: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/20.jpg)
BUILDING EVACUATION ANALYSIS
❑ Our building evacuation study analyses the most
effective routes of egress in the event of a fire or any
other emergency that is a threat to life
❑ Using simulations, an occupant evacuation model is
created, which factors in a threat assessment of all
points of origin of the fire and all the potential
blockage points during the evacuation.
❑ The occupant evacuation model simulates evacuation
in static and dynamic blocking situations and records
occupation changes at every section during the
process of egress.
❑ Estimate time required for occupants to exit a
building. Modification required to exit path are
suggested for achieving desire evacuation time.
![Page 21: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/21.jpg)
PRESSURIZATION ANALYSIS
❑ Our pressurization analysis tool can be useful for
assessing the adequacy of ventilation rates in a
building, and for estimating the impact of
envelope air-tightening efforts on infiltration rates
and associated energy implications.
❑ Stairwell pressurization analysis helps Architects
and Structural Engineers to define the right level
of pressurization; sufficient enough to keep
smoke out of the building and not so high that
stairwells are not easy to access during an
evacuation.
❑ Various fire scenarios can be simulated, and
potential catastrophic situations can be easily
preempted.
![Page 22: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/22.jpg)
NICHE PROJECTS
NATURAL COOLING WITH RADIANT
◼ IITM CCCR Pune
Radiant Cooling (Maintaining 27°C) for over 8500 sq. ft. of Research Center in conjunction with a Centralized Chiller Water System.
Pre-cooling of fresh air intake with earth pipe heat exchanger 4 meters below earth’s surface
◼ AOL Meditation Hall Markal
Radiant Cooling with Cooling Tower Water for over 9000 sq. ft. meditation hall area
2-stage Evaporative Cooling for additional conditioning of room air
Use of HVLS fans for further cooling effect within the area
![Page 23: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/23.jpg)
NICHE PROJECTS
RADIANT COOLING
◼ Bajaj Auto Industries Akurdi
▪ Radiant Cooling in conjunction with a Centralized Chilled Water System + Treated Make Up Air / Supplementary Cooling
▪ Toilet, EPR, Locker Room and Parking Ventilation.
◼ Macbrout Goa
▪ Radiant Cooling for Production Areas in conjunction with a Centralized Chilled Water System
◼ Mahindra Towers Chakan
▪ Radiant cooling in conjunction with Centralized Chilled Water System + Treated Make Up Air / Supplementary Cooling
▪ Data Center 24 x 7 AC with DX units (1W + 1S)
▪ Basement Parking Ventilation
![Page 24: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/24.jpg)
SELECT COMMERCIAL PROJECTS
◼ Cummins Balewadi
◼ Tech Park II
◼ Intas Office
◼ Cello Mall
◼ Kalpataru Pune Office
◼ Balewadi Properties
◼ EON Kharadi Phase II
◼ WTC Building 1
◼ Aker Power Gas
◼ SP Infocity
◼ The Pavillion Mall
◼ Pheonix Marketcity Pune
![Page 25: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/25.jpg)
SELECT HOTEL PROJECTS
◼ JW Marriott, Pune.
◼ Courtyard, Hinjewadi
◼ Ritz Carlton, Pune
![Page 26: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/26.jpg)
SELECT HOSPITAL PROJECTS
◼ Satara Diagnostic Centre
◼ Asian Eye Clinic
◼ Rotary Global Hospital
◼ Surya Hospital
◼ Sahyadri Hospital
◼ Ruby Hall Clinic Sasoon Road all Upgradations
◼ Ruby Hall Clinic Wanoerie | Hinjewadi
◼ Cure-all Cancer Hospital
◼ Sancheti Hospital
![Page 27: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/27.jpg)
PROOF CONSULTANCY PROJECTS
◼ Taj Dwarka
◼ Cipla Sikkim Plant 2
◼ Sunpharma Guwahati
◼ Swiss Garnier Sikkim
![Page 28: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/28.jpg)
PRECISION AC UNIT PROJECTS
◼ Tech Mahindra
◼ IITM – Data Centre for full
facility
◼ Persistent Data Centre
◼ Q- Logic Pune
◼ Times of India (Hyderabad)
◼ Times of India (Kandivali)
◼ Times of India (Sahibabad)
◼ UGS Pune
◼ Cummins Global Tech Centre
◼ Cyquator Technology
◼ Iradium (Pune)
![Page 29: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/29.jpg)
SELECT RESIDENTIAL PROJECTS
◼ Castel Royale 8 Towers Pune – ABIL Group
◼ Kunal Residential Township
◼ Kalpataru Residential Baner
◼ Elite Residential Baner
◼ Avanti Residential – ABIL Group
◼ Hyde Park Phase 1A
◼ Wagholi Township
◼ Rohan Builders
![Page 30: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/30.jpg)
KEY INDUSTRIAL PROJECTS
◼ Sonatape Goa
◼ Intas R&D Centre Matoda
◼ Cummins CIL Training Center
◼ Cummins HCC
◼ Cummins TCL3 Phaltan
◼ Times Of India (8 Plants)
◼ Cummins BCL
◼ Cummins PGBU
◼ Cummins Pithumpur
◼ Kilitch Drugs (4 Plants)
◼ Cipla Verna (9 Plants)
◼ Cipla Sikkim (3 Plants)
◼ Cipla Indore (3 Plants)
◼ Cipla Baddi / Cipla Bangalore
![Page 31: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/31.jpg)
NICHE IT PROJECTS
◼ KPIT Cummins Hinjewadi
◼ PSPL Nagpur
◼ PSPL Karve Road
◼ PSPL Senapati Bapat Road
◼ BMC Software
![Page 32: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/32.jpg)
KEY PHARMACEUTICAL PROJECTS
◼ Sun Pharma OSD & Injectable,
Guwahati
◼ Cipla Sikkim II
◼ Cipla – Patalganga II Pharma
Manufacturing Expansion
◼ Intas Pharmaceuticals Ltd. –
Matoda
◼ Sun Pharmaceutical Industries
Ltd., Halol
◼ Kilitch NBZ Pharma
◼ Cipla – Baddi
◼ Cipla – Indore (3 Plants)
◼ Cipla – Bangalore
◼ Cipla – Verna (9 Plants)
◼ Okasa Pharma Ltd., Satara
◼ Pharma Access - Asia Pharma QC
Lab, Syria
◼ Cipla Limited, Goa
![Page 33: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/33.jpg)
PHARMACEUTICAL PROJECTS CONTD.
◼ Aarti Industries – Tarapur
◼ Aarti Industries - Pithampur
◼ Cipla – PFS Pithampur
◼ Glenmark Pharmaceuticals, Goa
◼ Okasa, Kundaim, Goa
◼ Pharma Access 2 & 4 , Syria
◼ Pharma Access 6, Romania
◼ Pharma Access, Sunny Medical,
Egypt
◼ Kilitch Drugs (I) Limited , Mumbai
◼ Cipla – Kurkumbh
◼ Pharma Access 14, Algeria
◼ Cipla – Sikkim, Golden cross,
Betalactum
◼ Cipla – Sikkim, Golden cross,
Liquid Ointment
◼ Kilitch drugs , Phase I & Phase II,
H.P.
◼ Pharma Access, Sanofi Aventis,
Egypt
◼ Medex Specialities, Kundaim
◼ Medispray, Kundaim
◼ Meditab Specialities, Kundaim
![Page 34: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/34.jpg)
PROJECTS IN HAND
OFFICE - SURVEY NO. 20, BALEWADI
▪ Area : 20,80,921 Sq. Ft.
▪ Capacity : 6500 TR
▪ Type of System :
➢ VRV\VRF System
➢ Ventilation System
➢ Smoke Exhaust System
![Page 35: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/35.jpg)
PROJECTS IN HAND
WAGHOLI TOWNSHIP & HIGHRISE, PUNE
▪ Area : 12,46,800 Sq. Ft.
▪ Capacity : 6800 TR
▪ Type of System :
➢ VRV for Villas, Club House,
Highrise Building
➢ Basement Ventilation
![Page 36: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/36.jpg)
PROJECTS IN HAND
OFFICE AT VIMANNAGAR, PUNE
▪ Area : 14,50,000 Sq. Ft.
▪ Capacity : 4600 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ventilation System
➢ Pressurization System
![Page 37: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/37.jpg)
PROJECTS IN HAND
PHOENIX MARKET CITY MALL, PUNE
▪ Area : 14,11,308 Sq. Ft.
▪ Capacity : 6750 TR
▪ Type of System :
➢ Chilled Water System
➢ Ventilation System
![Page 38: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/38.jpg)
PROJECTS IN HAND
WAGHOLI OFFICE TOWER, PUNE
▪ Area : 27,99,117 Sq. Ft.
▪ Capacity : 8800 TR
▪ Type of System :
➢ VRV/VRF System
➢ Pressurization System
➢ Ventilation System
![Page 39: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/39.jpg)
PROJECTS IN HAND
MAHINDRA CHAKAN, PUNE
▪ Area : 1,56,142 Sq. Ft.
▪ Capacity : 315 TR
▪ Type of System :
➢ Radiant Cooling System
➢ Pressurization System
➢ Ventilation System
![Page 40: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/40.jpg)
PROJECTS IN HAND
HOTEL TIP TOP INTERNATIONAL, PUNE.
▪ Area : 3,16,900 Sq. Ft.
▪ Capacity : 1264 TR
▪ Type of System :
➢ AC Chiller System
➢ Heat Pump System
➢ Ventilation System
![Page 41: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/41.jpg)
PROJECTS IN HAND
GREEN FIELD MANUFACTURING PLANT, CHAKAN
▪ Area : 10,120 Sq. Ft.
▪ Capacity : 90 TR
▪ Type of System :
➢ VRV/VRF System
➢ AHU System
➢Cooling Tower System
![Page 42: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/42.jpg)
PROJECTS IN HAND
GADKARI WADA
▪ Area : 20,326 Sq. Ft.
▪ Capacity : 111 TR
▪ Type of System :
➢Natural Cooling System
➢ VRV/VRF System
➢ Ventilation System
![Page 43: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/43.jpg)
COMPLETED PROJECTS
BAJAJ AUTO LTD. AKURDI, PUNE.
▪ Area : 2,25,006 Sq. Ft.
▪ Capacity : 532 TR
▪ Type of System :
➢ Radiant Cooling System
➢ Embedded PEX Piping
![Page 44: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/44.jpg)
COMPLETED PROJECTS
MARKAL AOL MEDITATION HALL, MARKAL
▪ Area : 9,383 Sq. Ft.
▪ Type of System :
➢ Radiant Cooling System
➢ Embedded PEX Piping
➢ AHU System
![Page 45: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/45.jpg)
COMPLETED PROJECTS
WTC-02, 03 & 04, PUNE
▪ Area : 21,52,000 Sq. Ft.
▪ Capacity : 4000 TR
▪ Type of System :
➢ VRV/VRF System
➢ Pressurization System
➢ Ventilation System
![Page 46: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/46.jpg)
COMPLETED PROJECTS
KSB – URJA AT SHIRWAL
▪ Area : 25,84,56 Sq. Ft.
▪ Capacity : 90 TR
▪ Type of System :
➢ Evaporative Cooling
➢ VRV/VRF System
➢ Ventilation System
![Page 47: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/47.jpg)
COMPLETED PROJECTS
CURE-ALL HOSPITAL, NAGPUR
▪ Area : 36,022 Sq. Ft.
▪ Capacity : 251 TR
▪ Type of System :
➢ Chilled Water System
➢ VRV/VRF System
➢ Hot Water Generation
➢ Evaporative Cooling System
![Page 48: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/48.jpg)
COMPLETED PROJECTS
TRUMP TOWER, PUNE (TOWERS A & B)
▪ Area : 2,50,000 Sq. Ft.
▪ Capacity : 160 TR
▪ Type of System :
➢ VRV/VRF System
➢ Pressurization System
➢ Ventilation System
![Page 49: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/49.jpg)
COMPLETED PROJECTS
PERSISTENT SYSTEM PVT. LTD. PUNE
▪ Area : 5,00,000 Sq. Ft.
▪ Capacity : 2000 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ozone Treatment System
➢ Ventilation System
![Page 50: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/50.jpg)
COMPLETED PROJECTS
TECH MAHINDRA LTD. HINJEWADI, PUNE.
▪ Area : 8,53,988 Sq. Ft.
▪ Capacity : 3000 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ozone Treatment System
➢ Pressurization System
![Page 51: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/51.jpg)
COMPLETED PROJECTS
JOTUN
▪ Area : 8,420 Sq. Ft.
▪ Capacity : 73 TR
▪ Type of System :
➢ VRV/VRF System
➢Chilled Water System
➢ Air Cooled Chiller System
![Page 52: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/52.jpg)
COMPLETED PROJECTS
MACBROUT ENGG. PVT. LIMITED, GOA
▪ Area : 46,000 Sq. Ft.
▪ Capacity : 258 TR
▪ Type of System :
➢ VRV/VRF System
➢ Radiant Cooling System
➢ Precision AC System
![Page 53: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/53.jpg)
COMPLETED PROJECTS
KIRLOSKAR BROTHER LTD., PUNE.
◼ Certified PLATINUM by IGBC
▪ Area : 1,11,633 Sq. Ft.
▪ Capacity : 400 TR
▪ Type of System :
➢ Water Cooled VRV/VRF
➢ Heat Recovery System
![Page 54: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/54.jpg)
COMPLETED PROJECTS
THE PAVILLION MALL, PUNE
▪ Area : 4,37,800 Sq. Ft.
▪ Capacity : 1739 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ozone Treatment System
➢ Pressurization System
➢ Heat Recovery System
➢ Ventilation System
![Page 55: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/55.jpg)
COMPLETED PROJECTS
CIPLA LIMITED, INDORE.
▪ Area : 1,77,755 Sq. Ft.
▪ Capacity : 3000 TR
▪ Type of System :
➢ Chiller Water System
➢ Clean Room
MORE THAN 20 PLANTS
FOR CIPLA PAN INDIA
![Page 56: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/56.jpg)
COMPLETED PROJECTS
BANER PORTIA, PUNE
▪ Area : 60,751 Sq. Ft.
▪ Capacity : 312 TR
▪ Type of System :
➢ VRV/VRF System
➢ Hot water Generation
➢ Pressurization System
![Page 57: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/57.jpg)
COMPLETED PROJECTS
CENTER FOR CLIMATE CHANGE RESEARCH (CCCR), PUNE
▪ Area : 12,000 Sq. Ft.
▪ Capacity : 100 TR
▪ Type of System :
➢ Radiant Cooling System
![Page 58: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/58.jpg)
COMPLETED PROJECTS
AIC RESIDENCE
▪ Area : 14,808 Sq. Ft.
▪ Capacity : 105 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ventilation System
![Page 59: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/59.jpg)
COMPLETED PROJECTS
RUBY HALL AT WANOWRIE, PUNE.
▪ Area : 1,01,423 Sq. Ft.
▪ Capacity : 500 TR
▪ Type of System :
➢ Chilled Water System
➢ VRF/VRV System
➢ Ventilation System
![Page 60: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/60.jpg)
COMPLETED PROJECTS
EON FREE ZONE, KHARADI, PUNE
▪ Area : 40,00,000 Sq. Ft.
▪ Capacity : 15000 TR
▪ Type of System :
➢ Evaporative Cooling System
➢ VRF/VRV System
➢ Pressurization System
➢ Ventilation System
![Page 61: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/61.jpg)
COMPLETED PROJECTS
EON OFFICE BUILDING AT SURVEY NO.72, KHARADI PUNE
▪ Area : 31,13,602 Sq. Ft.
▪ Capacity : 9210 TR
▪ Type of System :
➢ VRV\VRF System
➢ Ventilation System
➢ Smoke Exhaust System
➢ Pressurization System
![Page 62: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/62.jpg)
COMPLETED PROJECTS
RUBY HALL HOSPITAL AT HINJEWADI, PUNE.
▪ Area : 34,877 Sq. Ft.
▪ Capacity : 220 TR
▪ Type of System :
➢ Heat Pumps for Hot water
generation.
➢ VRV\VRF System
➢ Basement Ventilation
![Page 63: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/63.jpg)
COMPLETED PROJECTS
HOTEL RITZ CARLTON AT TECH PARK II, PUNE
▪ Area : 2,72,404 Sq. Ft.
▪ Capacity : 750 TR
▪ Type of System :
➢ Chilled Water System
➢ Smoke Exhaust System
➢ Pressurization System
➢ Basement Ventilation
![Page 64: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/64.jpg)
COMPLETED PROJECTS
KANSAI NEROLAC PAINTS LTD
▪ Area : 35,800 Sq. Ft.
▪ Capacity : 65 TR
▪ Type of System :
➢ VRV/VRF System
➢ Ventilation System
![Page 65: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/65.jpg)
COMPLETED PROJECTS
CUMMINS TECHNICAL CENTRE INDIA, PUNE
▪ Area : 3,99,151 Sq. Ft.
▪ Capacity : 2140 TR
▪ Type of System :
➢ Chilled Water System
➢ VRV/VRF System
➢ Precision Units
➢ Ventilation System
![Page 66: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/66.jpg)
COMPLETED PROJECTS
AXALTA
▪ Area : 57,642 Sq. Ft.
▪ Capacity : 55 TR
▪ Type of System :
➢ Evaporative Cooling System
➢ VRV/VRF System
➢ Ventilation System
![Page 67: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/67.jpg)
COMPLETED PROJECTS
SAHYADRI HOSPITAL HADAPSAR-PUNE
▪ Area : 68,730 Sq. Ft.
▪ Capacity : 419 TR
▪ Type of System :
➢Chilled Water System
➢ VRV/VRF System
➢ Ventilation System
![Page 68: R. S. KULKARNI HVACR CONSULTANT · contacting us r.s. kulkarni hvacr consulting engineers office no. 512 + 513, siddharth tower, sangam press road, kothrud, pune –411 029 +91–020–41315512/13/14/15](https://reader036.vdocuments.mx/reader036/viewer/2022062414/5f1d81d45b2f1131b25622dc/html5/thumbnails/68.jpg)
FROM TEAM RSK