r greeley fire station #2greeleygov.com/docs/default-source/bid-documents/9... · a 201 exterior...

2
VICINITY MAP PROJECT DIRECTORY LOCATION MAP SHEET INDEX SHEET INDEX 100% DESIGN DOCUMENTS 10/21/2019 4:22:04 PM City of Greeley GREELEY FIRE STATION #2 2301 RESERVOIR RD, GREELEY, CO 80634 R SEH Project Checked By Drawn By Project Status Issue Date This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH. Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. Architect/ Civil Engineer/ Structural Landscape Architect Mechanical Engineer Electrical Engineer Owner Short Elliott Hendrickson, Inc. 2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800 Short Elliott Hedrickson, Inc. All Rights Reserved COPYRIGHT © 2019 Technology BCER Engineering Inc 5420 Ward Rd Arvada, CO 80002 303.422.7400 City of Greeley 1000 10th Street Greeley, Colorado 80631 970.350.9777 10/21/2019 4:22:04 PM COVER SHEET G 000 GREELEY FIRE STATION #2 2301 RESERVOIR RD, GREELEY, CO 80634 150268 CS CS/JH/MM/AA City of Greeley 30% DESIGN 75% DESIGN 100% DESIGN 06/26/2019 09/16/2019 10/18/2019 DHM Design 900 South Broadway Denver, Colorado 80209 303.892.5566 The Ballard Group, Inc 2525 South Wadsworth Blvd, Suite 200 Lakewood, CO 80227 303.988.4514 CMO Consulting Eng 11646 Sun Bear TrailGolden, CO 80403 303.875.4037 OWNER ARCHITECT / CIVIL / STRUCTURAL LANDSCAPE ARCHITECT City of Greeley 10th Street Greeley, CO 80631 970.350.9777 Short Elliott Hendrickson, Inc. 2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800 DHM Design Corporation 900 S Broadway #300 Denver, CO 80209 303.892.5566 MECHANICAL ENGINEER The Ballard Group 2525 S Wadsworth Blvd #200 Lakewood, CO 80227 303.988.4514 ELECTRICAL ENGINEER CMO Consulting Engineering 11646 Sun Bear Trail Golden, CO 80403 303.875.4037 GENERAL G 000 COVER SHEET G 001 GENERAL INFORMATION AND ABBREVIATIONS CIVIL C 100 CIVIL GENERAL NOTES C 101 DEMOLITION PLAN PHASE I C 102 DEMOLITION PLAN PHASE II C 201 SITE PLAN PHASE I C 202 SITE PLAN PHASE II C 301 HORIZONTAL CONTROL PLAN PHASE I C 302 HORIZONTAL CONTROL PLAN PHASE II C 401 GRADING PLAN PHASE I C 402 GRADING PLAN PHASE II C 501 EROSION CONTROL PLAN PHASE I C 502 EROSION CONTROL PLAN PHASE II C 601 UTILITY PLAN PHASE I C 701 DETAILS C 702 DETAILS C 703 DETAILS C 704 DETAILS C 705 DETAILS LANDSCAPE LS-1 LANDSCAPE PLAN - PHASE 1 LS-2 LANDSCAPE PLAN - PHASE 2 LS-3 LANDSCAPE SCHEDULE & NOTES LS-4 LANDSCAPE DETAILS ARCHITECTURAL A 001 CODE INFORMATION A 002 ADA DETAILS A 003 ADA DETAILS A 011 PARTITION TYPES AND CONSTRUCTION ASSEMBLIES A 051 ARCHITECTURAL SITE PLAN A 111 FLOOR PLANS A 113 ROOF PLAN A 151 REFLECTED CEILING PLAN - LEVEL 1 A 201 EXTERIOR ELEVATIONS A 301 BUILDING SECTIONS A 302 BUILDING SECTIONS A 311 WALL SECTIONS A 312 WALL SECTIONS A 401 VERTICAL CIRCULATION PLANS AND SECTIONS A 421 ENLARGED PLANS AND INTERIOR ELEVATIONS A 422 ENLARGED PLANS AND INTERIOR ELEVATIONS A 501 EXTERIOR DETAILS A 502 EXTERIOR DETAILS A 503 EXTERIOR DETAILS A 601 DOOR SCHEDULE / DOOR, FRAME AND WINDOW ELEVATIONS A 602 DOOR DETAILS A 603 WINDOW SCHEDULE & LEGEND A 611 ROOM FINISH SCHEDULE A 621 CASEWORK MECHANICAL M 000 MECHANICAL COVER SHEET - LEGEND, GENERAL NOTES & SHEET INDEX M 111 HVAC FLOOR PLANS M 112 HVAC PIPING FLOOR PLANS M 113 ROOF HVAC PLAN M 411 ENLARGED HVAC MECHANICAL ROOM PLAN M 600 HVAC SCHEDULES M 601 HVAC SCHEDULES M 700 HVAC DETAILS M 701 HVAC DETAILS M 800 HVAC CONTROL DIAGRAMS M 801 HVAC CONTROL DIAGRAMS M 900 HVAC OUTSIDE AIR CALCULATIONS M 901 HVAC OUTSIDE AIR CALCULATIONS STRUCTURAL S 001 GENERAL STRUCTURAL NOTES S 002 GENERAL STRUCTURAL NOTES S 101 FOUNDATION PLAN S 102 LOWER ROOF / MEZZANINE PLAN S 103 UPPER ROOF PLAN S 301 SECTIONS S 401 ENLARGED PLANS S 500 FOUNDATION DETAILS S 501 FOUNDATION DETAILS S 510 MASONRY DETAILS S 511 MASONRY DETAILS S 520 STEEL DECK DETAILS S 530 STEEL FRAMING DETAILS S 531 STEEL FRAMING DETAILS S 532 STEEL FRAMING DETAILS S 533 STEEL FRAMING DETAILS S 540 TYPICAL REINFORCING DETAILS S 550 SHEAR WALL DETAILS S 560 STEEL JOIST LOAD DIAGRAM ELECTRICAL E 001 ELECTRICAL LEGEND E 010 ELECTRICAL SITE PLAN E 011 SITE PHOTOMETRICS E 012 EXTERIOR LIGHT CUT SHEETS E 111 LIGHTING PLAN E 211 POWER PLAN E 401 ONE LINE DIAGRAM E 402 PANEL SCHEDULES E 501 ELECTRICAL DETAILS E 502 ELECTRICAL DETAILS E 503 COMCHECK PLUMBING P 000 PLUMBING COVER SHEET - LEGEND, GENERAL NOTES AND SHEET INDEX P 111 PLUMBING FLOOR PLANS P 113 ROOF PLUMBING PLAN P 300 ENLARGED SCALE PLUMBING PLAN P 500 PLUMBING DETAILS P 600 PLUMBING SCHEDULES P 700 PLUMBING ISOMETRICS TECHNOLOGY T 001 COMMUNICATIONS TITLE SHEET T 002 COMMUNICATIONS PROJECT NOTES T 003 COMMUNICATIONS PROJECT NOTES T 004 COMMUNICATIONS SCHEDULES T 005 COMMUNICATIONS SCHEDULES T 051 COMMUNICATIONS SITE PLAN T 111 COMMUNICATIONS FLOOR PLANS T 401 ENLARGED TELECOM ROOM T 501 COMMUNICATIONS ONE-LINE DIAGRAMS T 502 COMMUNICATIONS BACKBONE PATHWAY DIAGRAM T 601 COMMUNICATIONS DETAILS T 602 COMMUNICATIONS DETAILS T 603 COMMUNICATIONS DETAILS 1 TECHNOLOGY BCER Engineering Inc 5420 Ward Rd Arvada, CO 80002 303.422.7400 2 REVISIONS Rev. # Description Date 1 ADDENDUM 01 09/18/2019 2 ADDENDUM 02 10/18/2019

Upload: others

Post on 19-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R GREELEY FIRE STATION #2greeleygov.com/docs/default-source/bid-documents/9... · a 201 exterior elevations a 301 building sections a 302 building sections a 311 wall sections a 312

VICINITY MAP PROJECT DIRECTORY

LOCATION MAP

SHEET INDEX

SHEET INDEX

100% DESIGN DOCUMENTS

10/2

1/20

19 4

:22:

04 P

MCity of Greeley

GREELEY FIRE STATION #2

2301 RESERVOIR RD, GREELEY, CO 80634

R

SEH Project

Checked By

Drawn By

Project Status Issue Date

This drawing is an instrument of service and shall

remain the property of Short Elliott Hendrickson, Inc.

(SEH). This drawing, concepts and ideas contained

herein shall not be used, reproduced, revised, or

retained without the express written approval of SEH.

Submission or distribution of this drawing to meet

official or regulatory requirements or for purposes in

connection with the project is not be construed as

publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Sho

rt E

lliot

t Hed

ricks

on, I

nc.

All

Rig

hts

Res

erve

d

CO

PY

RIG

HT

© 2

019

Technology

BCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

10/2

1/20

19 4

:22:

04 P

M

COVER SHEET

G000

GR

EE

LE

Y F

IRE

ST

AT

ION

#2

2301

RE

SE

RV

OIR

RD

, GR

EE

LEY

, CO

806

34

150268

CS

CS/JH/MM/AA

City

of G

ree

ley

30% DESIGN

75% DESIGN

100% DESIGN

06/26/2019

09/16/2019

10/18/2019

DHM Design900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group, Inc2525 South Wadsworth Blvd, Suite 200Lakewood, CO 80227303.988.4514

CMO Consulting Eng11646 Sun BearTrailGolden, CO 80403303.875.4037

OWNER

ARCHITECT / CIVIL / STRUCTURAL

LANDSCAPE ARCHITECT

City of Greeley

10th Street

Greeley, CO 80631

970.350.9777

Short Elliott Hendrickson, Inc.

2000 South Colorado

Boulevard

Tower One, Suite 6000

Denver, Colorado 80222

720.540.6800

DHM Design Corporation

900 S Broadway #300

Denver, CO 80209

303.892.5566

MECHANICAL ENGINEERThe Ballard Group

2525 S Wadsworth Blvd #200

Lakewood, CO 80227

303.988.4514

ELECTRICAL ENGINEERCMO Consulting Engineering

11646 Sun Bear Trail

Golden, CO 80403

303.875.4037

GENERAL

G 000 COVER SHEET

G 001 GENERAL INFORMATION AND ABBREVIATIONS

CIVIL

C 100 CIVIL GENERAL NOTES

C 101 DEMOLITION PLAN PHASE I

C 102 DEMOLITION PLAN PHASE II

C 201 SITE PLAN PHASE I

C 202 SITE PLAN PHASE II

C 301 HORIZONTAL CONTROL PLAN PHASE I

C 302 HORIZONTAL CONTROL PLAN PHASE II

C 401 GRADING PLAN PHASE I

C 402 GRADING PLAN PHASE II

C 501 EROSION CONTROL PLAN PHASE I

C 502 EROSION CONTROL PLAN PHASE II

C 601 UTILITY PLAN PHASE I

C 701 DETAILS

C 702 DETAILS

C 703 DETAILS

C 704 DETAILS

C 705 DETAILS

LANDSCAPE

LS-1 LANDSCAPE PLAN - PHASE 1

LS-2 LANDSCAPE PLAN - PHASE 2

LS-3 LANDSCAPE SCHEDULE & NOTES

LS-4 LANDSCAPE DETAILS

ARCHITECTURAL

A 001 CODE INFORMATION

A 002 ADA DETAILS

A 003 ADA DETAILS

A 011 PARTITION TYPES AND CONSTRUCTION ASSEMBLIES

A 051 ARCHITECTURAL SITE PLAN

A 111 FLOOR PLANS

A 113 ROOF PLAN

A 151 REFLECTED CEILING PLAN - LEVEL 1

A 201 EXTERIOR ELEVATIONS

A 301 BUILDING SECTIONS

A 302 BUILDING SECTIONS

A 311 WALL SECTIONS

A 312 WALL SECTIONS

A 401 VERTICAL CIRCULATION PLANS AND SECTIONS

A 421 ENLARGED PLANS AND INTERIOR ELEVATIONS

A 422 ENLARGED PLANS AND INTERIOR ELEVATIONS

A 501 EXTERIOR DETAILS

A 502 EXTERIOR DETAILS

A 503 EXTERIOR DETAILS

A 601 DOOR SCHEDULE / DOOR, FRAME AND WINDOW ELEVATIONS

A 602 DOOR DETAILS

A 603 WINDOW SCHEDULE & LEGEND

A 611 ROOM FINISH SCHEDULE

A 621 CASEWORK

MECHANICAL

M 000 MECHANICAL COVER SHEET - LEGEND, GENERAL NOTES & SHEET INDEX

M 111 HVAC FLOOR PLANS

M 112 HVAC PIPING FLOOR PLANS

M 113 ROOF HVAC PLAN

M 411 ENLARGED HVAC MECHANICAL ROOM PLAN

M 600 HVAC SCHEDULES

M 601 HVAC SCHEDULES

M 700 HVAC DETAILS

M 701 HVAC DETAILS

M 800 HVAC CONTROL DIAGRAMS

M 801 HVAC CONTROL DIAGRAMS

M 900 HVAC OUTSIDE AIR CALCULATIONS

M 901 HVAC OUTSIDE AIR CALCULATIONS

STRUCTURAL

S 001 GENERAL STRUCTURAL NOTES

S 002 GENERAL STRUCTURAL NOTES

S 101 FOUNDATION PLAN

S 102 LOWER ROOF / MEZZANINE PLAN

S 103 UPPER ROOF PLAN

S 301 SECTIONS

S 401 ENLARGED PLANS

S 500 FOUNDATION DETAILS

S 501 FOUNDATION DETAILS

S 510 MASONRY DETAILS

S 511 MASONRY DETAILS

S 520 STEEL DECK DETAILS

S 530 STEEL FRAMING DETAILS

S 531 STEEL FRAMING DETAILS

S 532 STEEL FRAMING DETAILS

S 533 STEEL FRAMING DETAILS

S 540 TYPICAL REINFORCING DETAILS

S 550 SHEAR WALL DETAILS

S 560 STEEL JOIST LOAD DIAGRAM

ELECTRICAL

E 001 ELECTRICAL LEGEND

E 010 ELECTRICAL SITE PLAN

E 011 SITE PHOTOMETRICS

E 012 EXTERIOR LIGHT CUT SHEETS

E 111 LIGHTING PLAN

E 211 POWER PLAN

E 401 ONE LINE DIAGRAM

E 402 PANEL SCHEDULES

E 501 ELECTRICAL DETAILS

E 502 ELECTRICAL DETAILS

E 503 COMCHECK

PLUMBING

P 000 PLUMBING COVER SHEET - LEGEND, GENERAL NOTES AND SHEET INDEX

P 111 PLUMBING FLOOR PLANS

P 113 ROOF PLUMBING PLAN

P 300 ENLARGED SCALE PLUMBING PLAN

P 500 PLUMBING DETAILS

P 600 PLUMBING SCHEDULES

P 700 PLUMBING ISOMETRICS

TECHNOLOGY

T 001 COMMUNICATIONS TITLE SHEET

T 002 COMMUNICATIONS PROJECT NOTES

T 003 COMMUNICATIONS PROJECT NOTES

T 004 COMMUNICATIONS SCHEDULES

T 005 COMMUNICATIONS SCHEDULES

T 051 COMMUNICATIONS SITE PLAN

T 111 COMMUNICATIONS FLOOR PLANS

T 401 ENLARGED TELECOM ROOM

T 501 COMMUNICATIONS ONE-LINE DIAGRAMS

T 502 COMMUNICATIONS BACKBONE PATHWAY DIAGRAM

T 601 COMMUNICATIONS DETAILS

T 602 COMMUNICATIONS DETAILS

T 603 COMMUNICATIONS DETAILS

1

TECHNOLOGYBCER Engineering Inc

5420 Ward Rd

Arvada, CO 80002

303.422.7400

2

REVISIONS

Rev. # Description Date

1 ADDENDUM 01 09/18/2019

2 ADDENDUM 02 10/18/2019

Page 2: R GREELEY FIRE STATION #2greeleygov.com/docs/default-source/bid-documents/9... · a 201 exterior elevations a 301 building sections a 302 building sections a 311 wall sections a 312

LAMINATED PLASTICL.P.

CONT. CONTINUOUS

CONTRACTORCONTR.COORDINATECOOR.

CORRIDORCORR.

CLEAN OUT TO GRADEC.O.T.G.CARPETCP.

CLOSET RODC.R.

CONCRETE RUBBLEC.R.M.

CERAMIC TILEC.T.

CENTERCTR.

COUNTERSUNKCTSK.CUSTOMCUST.

COLD WATERC.W.

COLD WATER RETURNC.W.R.

PENNY (NAILS)d

DEEP/DEPTH/DRYERD.DOUBLE ACTINGD.A.

DOUBLEDBL.

DECK DRAIND.D.DEPARTMENTDEPT.

DETAILDET.

DRINKING FOUNTAIND.F.

DIAMETERDIA.DIAGONALDIAG.

DIMENSIONDIM.

DISPENSERDISP.DOWNDN.

DOOR OPENINGD.O.

DEMOUNTABLE PARTITIOND.PTN.DOORDR.

DOWNSPOUTDS.

DRY STANDPIPED.SP.DISHWASHERDW.

DRAWINGDWG.

DRAWERDWR.

EASTE.

EACHEA.

EXHAUST AIR REGISTERE.A.R.ELASTOMERIC COATING/E.C.

EXPOSED CONSTRUCTION

EXHAUST FANE.F.EXTERIOR FINISH SYSTEME.F.S.

EXTERIOR GYPSUME.G.C.B.

CEILING BOARDEXTERIOR GYPSUME.G.S.B.

SHEATHING BOARD

MASONRY

EXTERIOR INSULATIONE.I.F.S.& FINISH SYSTEM

EXPANSION JOINTE.J.

ELEVATIONEL.

ELASTOMERICELAS.ELECTRICALELEC.

ELEVATORELEV.

EMERGENCYEMER.ENCLOSUREENCL.

EDGE OF SLABE.O.S.

ELECTRIC PANELE.P.EQUALEQ.

EQUIPMENTEQPT.

EACH WAYE.W.ELECTRIC WATER COOLERE.W.C.

EXHAUSTEXH.

EXPANSIONEXP.

EXPOSEDEXPO.EXISTINGEXIST.

EXTERIOREXT.

FEMALEF.

FIRE ALARMF.A.

FABRICATEFAB.FLUID APPLIED MEMBRANEF.A.M.

FLAT BARF.B.

FLOOR CLEAN OUTF.C.O.FAN COIL UNITF.C.U.

FLOOR DRAIN/F.D.

FIRE DAMPERFIRE EXTINGUISHERF.E.

FIRE EXTINGUISHERF.E.C.

CABINET

K.D. KNOCK DOWN

KG. KILOGRAMKIT. KITCHEN

KM. KILOMETER

K.O. KNOCK-OUTKW. KILOWATT

L. LENGTH/LONGLAB. LABORATORY

LAM. LAMINATE/LAMINATED

LAV. LAVATORYLB. POUND

L.F. LINEAL FOOT

LIQ. LIQUORLKR. LOCKER

LOC. LOCATION

LTG. LIGHTINGLVR. LOUVER

M. MALEMAT'L. MATERIAL

MAX. MAXIMUM

M.B. MACHINE BOLTM.C. MEDICINE CABINET

MECH. MECHANICAL

MEMB. MEMBRANEMET. METAL

MFR. MANUFACTURER

MH. MANHOLEMIN. MINIMUM

MIR. MIRROR

MISC. MISCELLANEOUS

MLDG. MOULDINGMM. MILLIMETER

M.O. MASONRY OPENING

MOD. MODULARM.R. MOISTURE RESISTANT

MTD. MOUNTED

MTG. MOUNTING

N. NORTH

N.I.C. NOT IN CONTRACTN.L. NIGHT LIGHT

NO. NUMBER

NOM. NOMINAL

N.S. NO SCALEN.T.S. NOT TO SCALE

O. OVERO.C. ON CENTER

OA. OVERALL

O.A.G. OUTSIDE AIR GRILLEOBS. OBSCURE

O.D. OUTSIDE DIAMETER

(DIMENSION)O.F./C.I. OWNER FURNISHED/

CONTRACTOR INSTALLED

OFD. OVERFLOW DRAINOFF. OFFICE

O.F./O.I. OWNER FURNISHED/

OWNER INSTALLED

OPNG. OPENINGOPP. OPPOSITE

OPQ. OPAQUE

OPR. OPERABLEOVHD. OVERHEAD

PASSAGEPASS.POST CONTRACTP.C.

POST CONTRACTP.C.A.

ARCHITECTURAL

PLANTER DRAINP.D.

PERIMETERPERIM.PERPENDICULARPERP.

PENTHOUSEPH.

POURED-IN-PLACEP.I.P.

STORAGESTOR.STRUCTURE/STRUCTURALSTRUCT.

SURROUNDSURR.

SUSPEND/SUSPENDEDSUSP.

SERVICESVC.SWITCHSW.

SYMETRICALSYM.

SYSTEMSYS.

TREADT.

TONGUE AND GROOVET&GTUB/SHOWERT./S.

TACKBOARDTACKBD.

TOWEL BART.B.TRENCH DRAINT.D.

TELEPHONETEL.

TEMPERED/TEMPORARYTEMP.TERRAZZOTER.

TRANSFORMERTFMR.

THICK/THICKNESSTHK.

THRESHOLDTHR.TOILETTLT.

TOP OF ...T.O.

TOP OF CURBT.O.C.TOP OF FLOORT.O.F.

TOP OF PARAPET/T.O.P.

TOP OF PAVEMENTTOP OF STEEL/T.O.S.

TOP OF SLAB

TOP OF WALLT.O.W.TELEPHONE POWERT.P.B.

BOARD

TOILET PAPER DISPENSERT.P.D.TOILET PAPER HOLDERT.P.H.

TRANSITIONTRAN.

TRANSPARENTTRANS.

TUBE STEELT.S.TOILET SEATT.S.C.D.

COVER DISPENSER

TOWEL SHELFT.SH.TELEVISIONTV.

TYPICALTYP.

UNDERCUTUC.

UNDERWRITERSU.L.LABORATORIES, INC.

PIECEPC.

UNFINISHEDUNF.

U.N.O. UNLESS NOTED OTHERWISEU.P. UPHOLSTERED PANELS

UR. URINAL

VAL. VALANCE

VAR. VARIES

V.C.T. VINYL COMPOSITION TILEVERT. VERTICAL

VEST. VESTIBULE

VLV. VALVE

VOL. VOLUMEV.P. VENEER PLASTER

V.T.R. VENT THROUGH ROOF

W. WEST/WIDTH/WIDE/WASHER

W/ WITHW/O WITHOUT

W.C. WATER CLOSET

WC. WALLCOVERINGWD. WOOD

WD.P. WOOD PANELING

WDW. WINDOWW.GL. WIRE GLASS

W.H. WATER HEATER

WARNOCK HERSEYW.O. WHERE OCCURS/

WINDOW OPENING

WP. WATERPROOFWP.M. WATERPROOF MEMBRANE

W.S. WOOD SCREWS

W.R. WATER RESISTANT

WRB. WARDROBEWSCT. WAINSCOT

W.S.P. WET STAND PIPE

WT. WEIGHTW.W.F. WELDED WIRE FABRIC

PLATE

PLASTER

PLASTIC LAMINATE

PLUMBINGPLYWOOD

PANEL

PRECAST

PAIR

PROPERTY

PREFABRICATEDPREPARATION

PRESSURE REDUCING

BACK FLOW PREVENTER

FOOT

PAINT/POINT

& RECEPTACLEPARTITION

PAPER TOWEL

RECEPTACLE

QUARRY TILE

PRESSURE RELIEF VALVEPOUNDS PER SQUARE

PAPER TOWEL DISPENSER

PAPER TOWEL DISPENSER

POLY VINYL CHLORIDE

PL.PLAM.

PLAS.

PLBG.PLYWD.

PROP.

PNL.

PR.P.R.B.P.

PRCST.

PREFAB.PREP.

& EQUIPMENT

FLAT HEAD

FINISH

FOLDING

FIXTURE

FLOOR

FEMININE NAPKIN

FLASHING

FLOORING

FLUORESCENT

FURNITURE, FIXTURE

FINISH FLOOR SEPARATION

FIRE HOSE CABINET

P.R.V.P.S.F.

PT.P.T.D.

P.T.D.R.

PTN.

P.T.R.

PVC

Q.T.

VENDOR

FOUNDATION

DISPOSAL

FEMININE NAPKIN

FACE OF ...

FACE OF FINISH

FRAME

GYPSUM

FACE OF SLAB/

FACE OF STUD

FACE OF WALL

FIBERGLASS REINFORCED

FACE OF CONCRETE

FACE OF MASONRY

FIBER REINFORCED

F.F.&E.

F.F.S.

F.H.

F.H.C.

F.N.D.

FIN.

FIXT.

FLASH.

FLDG.FLG.

FLR.

FLUOR.

AT

AND

CENTERLINE

DIAMETER/ROUNDEXISTING

ABOVE

POUND/NUMBER

PLUS OR MINUS

ANCHOR BOLT

PROPERTY LINESQUARE

AIR CONDITIONING

FND.

F.N.V.

F.O.F.O.C.

F.O.F.

F.R.P.

F.O.M.F.O.S.

F.O.W.

FR.F.R.G.

ACCESSIBLE

ACOUSTICAL

AREA DRAINACCESS DOOR

ADDENDUM

ADJUSTABLE

ANGLE

ADJACENT

ACCESS FLOOR

AGGREGATE

ALUMINUM

ASPHALTIC CONCRETE

ABOVE FINISH FLOOR

AIR HANDLING UNIT

ALTER OR ALTERNATE

#

&

@

O(E)

ABV.

+/-

A/CA.B.

PSQ

A.C.ACC.

ACOUS.

A.D.

ADD.

ADJ.

ANG.

ADJA.

A.F.

A.F.F.

AGGR.A.H.U.

ALUM.

ALT.

ROOFING

RAILING

ROOM

RECESSED WASTE

REGISTERROUND HEAD

ROUGH OPENING

SOUTH

RECEPTACLEREDWOOD

SINGLE ACTING

SOLID CORE

RESILIENT FLOORING

RAIN WATER LEADER

POLYESTER

FIRE RETARDANT

TREATED WOODFREEZER

FOOT/FEET

FOOTING

FUTURE

GAGEGALLON

FURRING/FURRED

GAS (PIPE)

FLOOR SINK/FULL SIZE

FACIAL TISSUE DISPENSER

R.F.

R.W.R.

RFG.

RGTR.R.H.

RLG.

RM.R.O.

RWD.

R.W.L.

S.S.A.

S.C.

GLASS

GALVANIZED

GRAB BARGENERATOR

GROUND FAULT

INTERCEPTORGLASS FIBER

GROUND

GYPSUM

REINFORCED CONCRETE

GLUED LAMINATED WOOD

GALLONS PER HOURGYPSUM SHEATHING BOARD

SCUPPER

SECTION

SCALESCHEDULE

SMOKE DETECTOR

SQUARE FEET

SEALANT

SHELFSHOWER

SHEET

SIMILAR

SLOPE

SLIDING

SHEATHING

SHOWER CURTAIN ROD

SQUARE METER

SEWER MANHOLESANITARY NAPKIN

DISPENSER

SANITARY NAPKIN

RECEPTACLESOLID PLASTIC

SQUARE

STONE

SPECIFICATIONS

SPEAKERSPRINKLER

SERVICE SINKSTAINLESS STEEL

SCHED.

SCP.

S.C.R.S.D.

SECT.

S.F.

SC.

SLNT.

SH.SHR.

SHT.

SHTG.SIM.

SL.

SLDG.

HEAD

HEIGHT/HIGH

HOSE BIB

HOLLOW COREHANDICAPPED

HARDWOODHARDWARE

HOUR

HEIGHT

HEATER

HOLLOW METAL

HORIZONTAL

HAND SINK

AND AIR CONDITIONING

HEATING, VENTILATION

S.M.

S.MH.S.N.D.

S.N.R.

S.P.

SPEC.

SPKR.SPRK.

SQ.

S.SK.S.STL.

ST.

INCH

HOT WATER

INSIDE DIAMETER(DIMENSION)

INVERT

JANITOR

INCLUDING

INSULATION

INTERIOR

JALOUSIE

HOT WATER RETURN

INCLUDED/INCLUSIVE/

F.R.T.

FRZ.

F.S.

F.T.D.FT.

FTG.

FURR.

FUT.

G.

GA.GAL.

ANODIZED

ACCESS PANELAPPROXIMATE

ARCHITECTURAL

ACOUSTIC TILE

ARCHITECTURAL

BOARD

BLOCK

BITUMINOUS

BUILDING

BLOCKING

WOODWORK

ASPHALT (PAVING)

GALV.

GL.

G.B.GEN.

G.F.I.

G.F.R.C.

GND.

G.P.H.

G.S.B.

GYP.

BEAM

BASEMENT

BACK OF HOUSE

BOTTOM

BEDROOMBEARING

BRACKET

BOTH SIDES

BETWEEN

CABINET

CATCH BASINCEMENTITIOUS

BUILT-UP ROOFING

CHORD/COMPACT

ANOD.

A.P.

ARCH.

ASPH.A.T.

A.W.

BD.

BITUM.

BLDG.BLK.

BLKG.

BM.

BSMT.

B.O.H.

BOT.

BR.BRG.

BRKT.

B.S.

BTWN.

B.U.R.

C

CAB.

C.B.C.B.B.

APPROX.

H.

H.B.

H.C.HCP.

HD.

HDWD.HDWE.

H.M.

HORIZ.HR.

H.S.

HT.

HTR.H.V.A.C.

CEILING DIFFUSER

BACKER BOARD

CLOSED CIRCUITTELEVISION

CEMENTCERAMIC

CAST-IN-PLACE

CORNER GUARD

CHANNEL

CAST IRON

CONTRACTOR FURNISHED

CONTRACTOR INSTALLEDCUBIC FEET PER MINUTE

CHILLED WATER RETURNCHILLED WATER SUPPLY

H.W.H.W.R.

I.D.

IN.

INCL.

INSUL.

INT.

INV.

JAL.

JAN.

CLEAR

CIRCULATING

CONTROL JOINT

CEILINGCLOSET

CENTIMETER

COUNTER

COLUMN

COMMUNICTATION

COMPARTMENTCONCRETE

CONCRETE MASONRY UNIT

CLEANOUT/CASED OPENING/CONCRETE OPENING

C.C.T.V.

C.D.

CEM.CER.

C.F./C.I.

C.I.P.

C.F.M.

C.G.

CHAN.

CH.W.R.CH.W.S.

C.I.

CIRC.

C.J.

CLNG.CLO.

CLR.

CM.C.M.U.

CNTR.

C.O.

COL.

COMM.

COMP.CONC.

GLU-LAM

STATION

STEEL

STANDARDSTA.STD.

STL.

JOIST

JOINT

JUNCTION BOXJ.B.JST.

JT.

CONDITION

CONNECTIONCONSTRUCTION

COND.

CONN.CONSTR.

L

l

CL

ANGLEL

RISERR.

RADIUSRESILIENT BASE

ROOF DRAIN

REINFORCING BAR

REFERENCE/REFER

ROBE HOOK

REFLECTORREFRIGERATOR

REQUIREDRESILIENT

RESTROOM

REVISED/REVISION

REFLECTED CEILING PLAN

REINFORCED/REINFORCING

RAD.R.B.

R.C.P.R.D.

REBAR

REF.

RB.HK.

REFL.REFR.

REINF.

REQ.RESIL.

REST.

REV.

SOIL

BASE COURSE, SUB-BASE, GRAVEL, CRUSHED ROCK

CONCRETE

BRICK MASONRY

CUT STONE, SAND, MORTAR, PLASTER

CONCRETE MASONRY UNITS

STONE, MARBLE, SIMULATED,MARBLE, TERRAZZO

STEEL

ALUMINUM (OMIT IN THIN MATERIAL)

BRONZE, BRASS, COPPER

INSULATION BOARD

RIGID INSULATION

WOOD, FINISH

WOOD FRAMING THROUGH

MEMBER

WOOD FRAMING

INTERRUPTED MEMBER

METAL LATH

PLYWOOD

GYPSUM BOARD

PARTICLE BOARD

GLASS BLOCK

GLASS

CARPET

CERAMIC TILE, QUARRY TILE,

OR RESILIENT FLOORING

(SHOWN PROFILE ONLY)

ASPHALTIC CONCRETE OR A.C. PAVING(SHOWN PROFILE ONLY)

BATT INSULATION

EX

DE

MO

NEW DOOR REPRESENTATION

NEW DOOR TAG

EXISTING DOOR REPRESENTATION

"EX" TEXT LABEL

DEMO DOOR REPRESENTATION

"DEMO" TEXT LABEL

WINDOW REPRESENTATION

WINDOW TAG

LOUVER REPRESENTATION

LOUVER TAG

100

?

?

NEW CONSTRUCTION NON-RATED

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.

DIMENSION TO FACE OF WALL OR PARTITION

DIMENSION TO CENTER OF WALL OR PARTITION

INTERNATIONAL SYMBOL: FIXTURE OR SPACE DESIGNED ACCESSIBLE

CONCRETE MASONRY PARTITION

CONCRETE PARTITION

(FOW)

A101

1SIM

1

A101

SIM

1

A101

SIM

1

A101

SIM

A101

#

# #

#

ROOMNAME

000

150 SF

LEVEL 1100'-0"

XXX

XX

XXXX

A

F#

R#

1

ELEVATION NUMBER

ELEVATION SHEET

DETAIL NUMBER

DETAIL SHEET

REVISION CLOUD

REVISION NUMBER

ELEVATION SHEET

ROOM AREA

ROOM NUMBER

ROOM NAME

ELEVATION NUMBER

LEVEL NAME

ELEVATION

WINDOW TAG

DOOR TAG

WALL TAG

SPECIAL EQUIPMENT TAG

KEYNOTE TAG

FLOOR TAG

ROOF TAG

WALL SECTION NUMBER

WALL SECTION SHEET

BUILDING SECTION NUMBER

BUILDING SECTION SHEET

1

A101

SIM

DETAIL NUMBER

DETAIL SHEET

1

A101

SIM

XX.XX

R

SEH Project

Checked By

Drawn By

Project Status Issue Date

This drawing is an instrument of service and shall

remain the property of Short Elliott Hendrickson, Inc.

(SEH). This drawing, concepts and ideas contained

herein shall not be used, reproduced, revised, or

retained without the express written approval of SEH.

Submission or distribution of this drawing to meet

official or regulatory requirements or for purposes in

connection with the project is not be construed as

publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Sho

rt E

lliot

t Hed

ricks

on, I

nc.

All

Rig

hts

Res

erve

d

CO

PY

RIG

HT

© 2

019

Technology

BCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

10/2

1/20

19 4

:22:

07 P

M

GENERAL INFORMATION ANDABBREVIATIONS

G001

GR

EE

LE

Y F

IRE

ST

AT

ION

#2

2301

RE

SE

RV

OIR

RD

, GR

EE

LEY

, CO

806

34

150268

CS

CS/JH/MM/AA

City

of G

ree

ley

30% DESIGN

75% DESIGN

100% DESIGN

06/26/2019

09/16/2019

10/18/2019

DHM Design900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group, Inc2525 South Wadsworth Blvd, Suite 200Lakewood, CO 80227303.988.4514

CMO Consulting Eng11646 Sun BearTrailGolden, CO 80403303.875.4037

ABBREVIATIONS MATERIAL SYMBOLS CALLOUT SYMBOLS

OPENING SYMBOLS GENERAL SYMBOLS

GENERAL NOTES

1. THESE DRAWINGS ARE LEGAL INSTRUMENTS OF SERVICE FOR THE USE OF THE OWNER AND ITSAUTHORIZED AGENTS AND VENDORS ON THE DESIGNATED PROJECT ONLY.

2. GC RESPONSIBLE FOR KNOWLEDGE OF RELATIVE INFORMATION CONTAINED IN THESEDOCUMENTS AND THE CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED.

3. CAREFULLY AND THOROUGHLY EXAMINE THE PROJECT SITE, FIELD VERIFY ALL CONDITIONS,GRADES, ELEVATIONS AND DIMENSIONS OF THE VARIOUS FEATURES OF THE SITE ANDCOMPARE DRAWINGS WITH THE EXISTING CONDITIONS. ANY DISCREPANCIES AND/ORCONDITIONS NEEDING CLARIFICATION SHALL BE REPORTED IN WRITING TO THE ARCHITECTBEFORE STARTING WORK.

4. ALL CONSTRUCTION, FABRICATION AND INSTALLATION SHALL CONFORM TO THE LATESTLOCALLY ADOPTED EDITIONS OF THE IBC, IPC, IMC, NEC, NFPA, OSHA AND ANY FEDERAL, STATEAND LOCAL CODES, REGULATIONS, STANDARDS AND ORDINANCES OF GOVERNING AGENCIESHAVING JURISDICTION. SUCH APPLICABLE CODES, ETC. ARE THOSE WHICH ARE IN EFFECT ATTHE TIME THE PROJECT PERMIT APPLICATION IS RECORDED.

5. ALL TRADES ARE CONSIDERED SPECIALISTS IN THEIR RESPECTIVE FIELD/TRADE AND SHALL,BEFORE SUBMISSION OF BID OR PERFORMANCE OF WORK, NOTIFY THE CONTRACTOR INWRITING OF ANY WORK ON THE DRAWINGS OR IN THE SPECIFICATIONS WHICH CANNOT BEFULLY WARRANTED OR CONSTRUCTED AS DETAILED OR SPECIFIED. THE CONTRACTOR WILLNOTIFY THE ARCHITECT OF SUCH CONDITIONS IN WRITING.

6. DUE TO REPRODUCTION PROCESSES, DRAWINGS MAY NOT BE ACCURATE TO SCALE. ALLDIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN AND IN NO CASE SHALL WORKINGDIMENSIONS BE SCALED FROM PLANS, SECTIONS, ELEVATIONS OR DETAILS.

7. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS ARESUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. DISCREPANCIES BETWEEN THEVARIOUS DRAWINGS SHALL BE REPORTED BY THE CONTRACTOR TO THE ARCHITECT INWRITING.

8. BEFORE STARTING WORK, COORDINATE WITH THE OWNER'S REPRESENTATIVE FORINSTALLATION OF EQUIPMENT INDICATED N.I.C. ON DRAWINGS. VERIFY EQUIPMENT LOCATIONSWITH THE OWNER'S PRESENTATIVE. VERIFY DIMENSIONS, UTILITIES, ETC, WITH EQUIPMENTMANUFACTURERS ROUGH -- IN DATA PRIOR TO FORMING THE SLAB.

9. PRODUCTS AND MANUFACTURED ITEMS SHALL BE PROVIDED AS SPECIFIED. SUBSTITUTIONSWILL BE PERMITTED IN ACCORDANCE WITH THE PROCEEDURES OUTLINED IN THESPECIFICATIONS.

10. WHERE DETAILS ARE NOT SHOWN OR NOTED, GC IS TO PROVIDE A WRITTEN REQUEST FORINFORMATION TO CLARIFY SPECIFIC DETAIL CONDITIONS.

11. ALL INDICATED EXISTING UTILITIES OR STRUCTURES ARE BASED ON INFORMATION OF RECORD.TAKE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES NOT OF RECORD OR NOTSHOWN. BE RESPONSIBLE FOR ANY AND ALL DAMAGE WHICH MAY OCCUR DUE TO FAILURE TOLOCATE AND PROTECT ALL CONCEALED UTILITIES.

12. COMPLY WITH ALL JURISDICTIONAL AGENCY REQUIREMENTS AND REGULATIONS. PERFORM ALLWORK ON THIS PROJECT IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTHSTANDARDS 29 CFR 1910 AND 1926 OF THE U.S. DEPARTMENT OF LABOR AND THE AMERICANSWITH DISABILITIES ACT ACCESSIBILITY GUIDELINES.

13. FINAL CONNECTIONS TO EQUIPMENT SHALL BE AS PER MANUFACTURER'S WIRING DIAGRAMS,DETAILS AND INSTRUCTIONS. BE RESPONSIBLE TO PROVIDE MATERIALS AND EQUIPMENTCOMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.

14. PROVIDE PERMITS AND INSPECTIONS REQUIRED BY JURISDICTIONAL AGENCIES.

15. PROVIDE SET OF RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL INCLUDE ALLADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC.

16. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. PROVIDEPORTABLE GENERATORS, CABLES, OUTLETS ETC., TO MAINTAIN CONTINUITY OF SERVICEPLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL.

17. COORDINATE CONSTRUCTION PHASING WITH THE OWNER. TEMPORARY PARTITIONS,LOCATIONS & CONSTRUCTION DETAILS IN PUBLIC SPACES SHALL BE SUBMITTED TO THEOWNER FOR APPROVAL PRIOR TO START OF CONSTRUCTION.

18. PATCH AND MATCH ALL NEW WORK W/ EXISTING WHERE NEW TO EXISTING INTERFACEOCCURS.

19. RESTORE ALL REMOVED OR DAMAGED STRUCTURAL STEEL CEMENTITIOUS FIRE PROOFING TOREQUIRED FIRE RESISTIVE STANDARD.

20. SUBMIT SAMPLES OF ALL EXPOSED PRODUCTS, MATERIALS, PAINTING SYSTEMS, ETC. FORARCHITECT'S REVIEW, COLOR SELECTION OR COLOR VERIFICATION PRIOR TO ORDERING ITEMS.

21. SEAL ALL DUCTS, LOUVERS, VENTS, OPENINGS AND CEILING SPACES BETWEEN CONSTRUCTIONAREA AND REMAINDER OF SHELLED SPACES TO PREVENT DUST, DIRT, CONTAMINATION ORDEBRIS FROM ENTERING.

22. DO NOT ALLOW DIRT, DEBRIS OR DISCARDED MATERIALS TO ACCUMULATE ON SITE. REMOVEPROMPTLY EACH DAY.

23. VERIFY SERVICES TO BE ABANDONED, REMOVED OR CUT HAVE BEEN PROPERLY AND SAFELYSHUT OFF, CAPPED OR SEALED.

24. KEEP NOISE AND VIBRATION PRODUCING ACTIVITIES AT A MINIMUM WHEN WORKING WITHIN ORON THE EXISTING BUILDING. APPROPRIATE TIMES OF SUCH ACTIVITIES SHALL BECOORDINATED WITH OWNER IN WRITING AT BEGINNING OF PROJECT.

25. IN THE EVENT THAT NOISE AND VIBRATION PRODUCING ACTIVITIES WILL OCCUR DURING TIMESOTHER THAN THOSE NOTED ABOVE, OBTAIN PERMISSION FROM THE OWNER IN WRITING AMINIMUM OF 72 HOURS PRIOR TO COMMENCEMENT OF ACTIVITIES.

26. KEEP UTILITY AND SERVICE OUTAGES TO A MINIMUM. MAKE WRITTEN OUTAGE REQUESTS ATLEAST FIVE DAYS BEFORE DATE OF PROPOSED OUTAGE. STATE IN THE REQUEST HOURS OFOUTAGE. CONFIRM DATE 48 HOURS IN ADVANCE OF STARTING DATE.

27. ASSIGN THE WORK OF MOVING, REMOVAL, CUTTING, PATCHING AND REPAIR TO TRADES UNDERCONTRACTOR SUPERVISION TO CAUSE THE LEAST DAMAGE TO EACH TYPE OF WORKENCOUNTERED.

28. PATCHING OF FINISH MATERIALS TO MECHANICS SKILLED IN THE WORK OF THE FINISH TRADEINVOLVED.

29. PROTECT REMAINING FINISHES, EQUIPMENT AND ADJACENT WORK FROM DAMAGE CAUSED BYCUTTING, MOVING AND REMOVAL AND PATCHING OPERATIONS. PROTECT SURFACES WHICHWILL REMAIN A PART OF THE FINISHED WORK.

30. PROTECT EXISTING AND NEW WORK FROM WEATHER DURING CUTTING, MOVING, REMOVALCONSTR. PROVIDE WEATHER PROTECTION AND OTHER FACILITIES AND PROTECTION ASNEEDED TO PREVENT DAMAGE TO NEW WORK AND TO REMAINING OLD WORK.

31. PROVIDE ADEQUATE SUPPORT OR SUBSTRATE FOR PATCHING FINISHES.

32. USE OF HAZARDOUS MATERIALS SHALL CONFORM WITH 29 CFR 1910.120 AND 1926.65 OF THEOSHA CODE.

33. REMOVAL OF HAZARDOUS WASTE SHALL COMPLY WITH CURRENT FEDERAL, STATE AND LOCALREGULATIONS, STANDARDS, LAWS AND REQUIREMENTS.

34. THE WET SIDE FIRE PROTECTION CONTRACTOR SHALL PROVIDE TO THE ARCHITECT, THROUGHTHE NORMAL SUBMITTAL PROCESS, SPRINKLER PLANS SHOWING PIPING PLANS, POINTS OFCONNECTIONS, HEAD LOCATIONS, VALVE LOCATIONS, CALCULATIONS, AND HEAD TYPES ANDFINISHES PRIOR TO SUBMISSION TO THE FIRE DEPARTMENT FOR THE ARCHITECT'S REVIEW ANDAPPROVAL. DO NOT SUBMIT DRAWINGS TO ANY JURISDICTION PRIOR TO GAINING THIS REVIEWAND APPROVAL.

35. THE ELECTRONIC FIRE PROTECTION CONTRACTOR SHALL PROVIDE TO THE ARCHITECT,THROUGH NORMAL SUBMITTAL PROCESS, PLANS SHOWING THE SIZE, LOCATION, MOUNTINGHEIGHTS, AND FINISH OF ALL STROBES, SPEAKERS, AND SPEAKER STROBES AS WELL ASSHOWING ALL CONDUIT RUNS, CONDUIT SIZES, AND POINTS OF CONNECTION FOR ARCHITECT'SREVIEW AND APPROVAL. DO NOT SUBMIT DRAWINGS TO ANY JURISDICTION PRIOR TO GAININGTHIS REVIEW AND APPROVAL.

1

REVISIONS

Rev. # Description Date

1 ADDENDUM 01 09/18/2019