r-410a multi digital scroll system - acson international selling kit/catalog/ap... · comsumption =...

29
All Product Brochure R-410A Multi Digital Scroll System

Upload: hadung

Post on 27-Mar-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

All Product Brochure

R-410A Multi Digital Scroll System

Page 2: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Central America• Barbados •

Oceania• Australia • Fiji • New Caledonia • Papua New Guinea •

Middle East• Jordan • Kuwait • Lebanon • Oman • Qatar • Saudi Arabia • Syria • UAE • Tunisia •

Europe• Austria • Czech Republic • Croatia • Denmark • England • Finland • Germany •

• Greece • Hungary • Italy • Kazakhstan • Netherlands • Poland •• Portugal • Romania • Russia • Spain • Sweden • Turkey •

With products available in more than 55 countries spread across 7 continents around the world, Acson is truly international. Backed by an advanced research and development team, state-of-the-art manufacturing facilities as well as highly-trained and extensive service network, Acson International has the key to provide ideal solution for any air-conditioning system.

With more than 25 years of manufacturing experience, Acson International has the proficient skills to continue to strive for quality excellence. Meanwhile, we devote our energy and effort to fulfil world wide customer satisfaction.

Even in light of our past efforts and success, we are as determined as ever to keep bringing our products and services to every corner of the world. Acson International is indeed “a global force with local presence”.

About Acson International

Asia• Bangladesh • India • Indonesia • Malaysia • Myanmar • Nepal • Pakistan • Sri Lanka •

GL

OBAL D

ISTRIBUTION NETWORK

Page 3: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

PRODUCT LINE-UP

9,000

15,000

20,000

25,000

30,000

40,000

50,000

60,000

100,000

200,000

300,000

400,000

450,000

500,000

OTHERS

Pg.4 Pg.10 Pg.20

System Features Application Accessories

Bu i ld ing Type : House / Apar tment / Condomin ium

Bu i ld ing Type :Schoo l / Co l l ege / Un ive rs i t y

Bu i ld ing Type : Depar tment S to re / Res tauran t

Pg.21

Job Reference

Pg.19

Software

2 3

Specification Pg.S2

Features

MDS-B Series(Single Condensing

Fan)

Pg.S1

Pg.12

MDS-B Series(Double Condensing

Fan)

MDS-B Series(Triple Condensing

Fan)

MDS-B Series(Quadruple

Condensing Fan)

Pg.S1

Pg.12

Wall MountedG Series

Pg.S4

Pg.13

Ceiling CassetteA Series

Pg.S5

Pg.14

Ceiling CassetteC Series

Pg.S5

Pg.14

Ceiling ConcealedC Series

Pg.S7

Pg.17

Ceiling ConvertibleE Series

Pg.S6

Pg.15

Ceiling ConvertibleD Series

Pg.S6

Pg.16Pg.12

Pg.S3

Pg.12

Cap

acity

(B

tu/h

r)

Cooling only ModelHeat Pump Model

Temp.

Time1 2 3 4

Tr

Ts

The temperature fluctuation range of traditional air conditioning system

The temperature fluctuation range of A5MDS system

Tr = Room TemperatureTs = Set Temperature

MDS100BR IPLV Testing

2

2.5

3

3.5

4

4.5

0 20 40 60 80 100

IPLV(C) = 3.56

IPLV(H) = 3.71

Capacity (%)

Cooling

Heating

COP (W/W)

IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoor and 27°C DB outdoor

Heating cycle: 20°C DB / 15°C WB indoor and 7°C DB / 6°C WB outdoor

Page 4: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

PRODUCT LINE-UP

9,000

15,000

20,000

25,000

30,000

40,000

50,000

60,000

100,000

200,000

300,000

400,000

450,000

500,000

OTHERS

Pg.4 Pg.10 Pg.20

System Features Application Accessories

Bu i ld ing Type : House / Apar tment / Condomin ium

Bu i ld ing Type :Schoo l / Co l l ege / Un ive rs i t y

Bu i ld ing Type : Depar tment S to re / Res tauran t

Pg.21

Job Reference

Pg.19

Software

2 3

Specification Pg.S2

Features

MDS-B Series(Single Condensing

Fan)

Pg.S1

Pg.12

MDS-B Series(Double Condensing

Fan)

MDS-B Series(Triple Condensing

Fan)

MDS-B Series(Quadruple

Condensing Fan)

Pg.S1

Pg.12

Wall MountedG Series

Pg.S4

Pg.13

Ceiling CassetteA Series

Pg.S5

Pg.14

Ceiling CassetteC Series

Pg.S5

Pg.14

Ceiling ConcealedC Series

Pg.S7

Pg.17

Ceiling ConvertibleE Series

Pg.S6

Pg.15

Ceiling ConvertibleD Series

Pg.S6

Pg.16Pg.12

Pg.S3

Pg.12

Cap

acity

(B

tu/h

r)

Cooling only ModelHeat Pump Model

Temp.

Time1 2 3 4

Tr

Ts

The temperature fluctuation range of traditional air conditioning system

The temperature fluctuation range of A5MDS system

Tr = Room TemperatureTs = Set Temperature

MDS100BR IPLV Testing

2

2.5

3

3.5

4

4.5

0 20 40 60 80 100

IPLV(C) = 3.56

IPLV(H) = 3.71

Capacity (%)

Cooling

Heating

COP (W/W)

IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoor and 27°C DB outdoor

Heating cycle: 20°C DB / 15°C WB indoor and 7°C DB / 6°C WB outdoor

Page 5: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

S y s t e m F e a t u r e s

Better Part Load EfficiencyMost air-conditioning system operates in the 30%~70% region. Integrated with the digital scroll compressor technology, A5MDS is capable to modulate its supply capacity to meet most indoors requirement closely.

This modulating capability enable the A5MDS system to offer higher IPLV (Integrated Part Load Value).

Utilising the digital scroll compressor technology, the R410A Acson Multi Digital Scroll System (A5MDS) is seen as the next generation products for high-efficiency air conditioning.

More Economical OperationWith higher IPLV, A5MDS is able to operate with lower power consumption.

A5MDS 100B System

100%

5%

FixedCompressorOperating

DigitalOperating

DigitalOperating

Loading Unloading

4

No Conversion LostComparing to the traditional inverter drive air-conditioner, A5MDS has eliminated the possibility of lost of energy during the conversion of power signal.

AC Converted Frequency InverterCompressor

Capacity Controller

TransformationConcumption = 0%

MotorConsumption

= 5-10%

DCAC DCTransformer

AC DCFrequency Conversion

DigitalCompressor

AC PWM valve

Capacity Controller

TransformationComsumption = 0%

T rad i t i ona l I n ve r t e r Sys temA5MDS Sys tem

A5MDS100BR IPLV Testing

2

2.5

3

3.5

4

4.5

0 20 40 60 80 100

IPLV(C) = 3.56

IPLV(H) = 3.71

Capacity (%)

Cooling

Heating

COP (W/W)

IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoor and 27°C DB outdoor

Heating cycle: 20°C DB / 15°C WB indoor and 7°C DB / 6°C WB outdoor

Page 6: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Improved Electromagnetic CompatibilityUnlike variable speed compressors air conditioners, A5MDS runs at a constant speed throughout the operation, thus there is lower electromagnetic interference. This unique feature reduces the need for expensive electromagnetic suppression electronics required to ensure electromagnetic compatibility.

5th

7th

11th

13th

17th

19th

0 1 2 3 4 5

A5MDS System EMC Standard Inverter System

EMC comparison during development stage

Tighter Temperature ControlThe ambient of the outdoor and indoor change frequently and this will affect the indoor cooling and heating load. With A5MDS system, using an improved control algorithm, the temperature is kept closer to the set temperature.

Temp.

Time1 2 3 4

Tr

Ts

The temperature fluctuation range of traditional air conditioning system

The temperature fluctuation range of A5MDS system

Tr = Room TemperatureTs = Set Temperature

Better Dehumidifying PerformanceThe continuously operating compressor in the A5MDS system provides better dehumidifying performance, and hence able to reduce the indoor RH to a more desired level. With lower RH in the interior, the growth of the bacteria and fungus are inhabited.

5

Page 7: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Better

PERFORMANCEBetter

CHOICEBetter

SOLUTIONS

t1 t2Time

InitialTemperature

SettingTemperature

Traditional Air ConditioningA5MDS System

Wider Opera t ing RangeA5MDS system undergo rigorous test to ensure that the system can operate within -15ºC to 43ºC.

Rap id Coo l ing and Heat ing Capab i l i t yThe improved heat-exchanger combining with the better efficiency compressor promotes rapid exchange between refrigerant and air, ensuring set temperature to be achieved faster compared to traditional air-conditioning system.

In te l l igen t Capac i ty Modu la t ionThe A5MDS system operates in a stepless capacity modulation ranging from 10~100%. The modulation will closely match the demand capacity whereby contributing higher IPLV.

Temperature °C

43°CDB

0°CDB

16°CWB

-15°CWDB

50

40

30

20

10

0

-10

-20

Cooling C

ycle

Heating Cycle

6

Page 8: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Long Piping Design For FlexibilityPiping length between outdoor and indoor unit can be extended up to 175 meters. The height between outdoor unit and indoor unit can be extended up to 50 meters. The height difference between indoor units can be as high as 15 meters. This greatly reduces constraint and offers more flexibility in system design.

Better Place UtilisationA5MDS uses the single outdoor multiple indoors combination. This concept has greatly reduced outdoor units and enhances flexibility during installation.

Comparing to conventional chilled water system, A5MDS required far less equipment. Boilers, cooling tower are things in the past with A5MDS. Thus, A5MDS is a better solution for new projects or even retrofit purposes.

Height15m

PipingLength175m

Height50m

Conventional ChilledWater System

A5MDS System

Only a common 2-core, screen cable wire is required to enable communication between outdoor and indoors.

The refnet joint is provided by the factory in accordance with different indoor units, which will reduce the work force at site.

Easier InstallationIn-house designed piping joints and wiring connection make it possible to install A5MDS systemfaster and easier.

7

Better Solution

Page 9: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Floor by F loor Ins ta l la t ion*The optional outdoor fan with external static pressure of 50Pa is suitable for short-discharge ductwork application. With this feature, an outdoor unit can be placed on each floor, thus allowing installation to be performed floor by floor.* Please contact your local sales office for more information.

8

A la rm and D iagnos is Sys temThe A5MDS system is built in with an alarm system, alerting owners or users for abnormal operation.

A user-friendly diagnosis system helps to identify the problems, ensuring continuous operation of the A5MDS system.

Adapts Eas ie r to Any F loor P lanThe wide indoor models can meet the needs of building size and interior design easier. Incorporate with the flexible piping design, the A5MDS systemis suitable for most type of floor layout and various applications.

AUTOAUTO

Page 10: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Cent ra l Cont ro l Sys temThe A5MDS System Management Software is designed with user-friendly interface, enable simple monitoring and control of the system via a computer.

9

Auto-Random Restar tAfter power failure, the A5MDS system will automatically restart operation base on the last state memory. Setting of the unit will not be lost, thus eliminating the needs for re-programming.

Var ie ty o f IndoorsThe A5MDS indoors come with a variety of design and capacity which can be selected to suit most air conditioning needs.

Large Capac i tyA5MDS-B series is capable to connect up to 48 units of indoors.Total indoor units capacity can range from 50% to 120% of theoutdoor capacity.

Page 11: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

With a l l these advantages , i t i s very c lear tha t A5MDS is a be t te r so lu t ion fo r cen t ra l i sed a i r -cond i t ion sys tem. What wou ld be the cons idera t ion fac to r to se lec t A5MDS? Here are some o f the main cons idera t ion fac to rs and examples .

Fac tor 1 - Locat ion fo r ou tdoor i s l im i ted . A5MDS can be used due to the ab i l i t y to coup le mul t ip le indoors w i th on ly 1 ou tdoor . Bet te r space u t i l i za t ion .

Fac tor 2 - Var ious type o f indoor un i t w i th separa te tempera ture requ i rementA5MDS sys tem can be coup le w i th var ious type o f indoors . Each indoor can be des ign to supp ly to a spec i f i c a rea on ly and the tempera ture se t t ing is base on ind iv idua l indoor se t t ing .

Fac tor 3 - Heat load o f the same a i r -cond i t ioned area var iesA5MDS is ab le to match the indoor load requ i rement w i th i t s par t load ing capab i l i t y .

Fac tor 4 - Cent ra l i zed Cont ro lA5MDS outdoors and indoors can be l inked together and cont ro l us ing the AMDS Cont ro l & Mon i to r ing Sof tware . The so f tware can a lso per fo rm schedu l ing o f the indoor un i ts base on the opera t ing dura t ion .

Fac tor 5 - P laces tha t requ i re low or no EMC in te r fe renceThe A5MDS modu la t ion is con t ro l by mechan ica l par ts . No change in power supp ly ( f requency or cur ren t ) , thus lower e lec t romagnet ic in te r fe rence.

10

A p p l i c a t i o n

Consideration:• Location for outdoor is limited.• Various type of indoor unit with separate temperature requirement.• Heat load of the same air-conditioned area varies

Bui ld ing Type: House / Apartment / Condominium

Considerat ion:• Heat load of the same air-condi t ioned area var ies.• Var ious type of indoor uni t wi th separate temperature requirement • Central ized Control

Bui ld ing Type: Exhibi t ion / Concert Hal l

Page 12: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Considerat ion:• Places that require low or no EMC interference • Heat load of the same air-condi t ioned area var ies.• Var ious type of indoor uni t wi th separate temperature requirement • Central ized Control

Bui ld ing Type: Hospi ta l

Considerat ion:• Heat load of the same air-condi t ioned area var ies.• Var ious type of indoor uni t wi th separate temperature requirement • Locat ion for outdoor is l imi ted• Central ized Control

Bui ld ing Type:Off ices

Considerat ion:• Heat load of the same air-condi t ioned area var ies.• Var ious type of indoor uni t wi th separate temperature requirement • Central ized Control

Bui ld ing Type: Department Store / Restaurant

11

Page 13: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Smal l Footpr in tThe outdoor unit of A5MDS system is designed as package, the structure occupies less space and is easier to move.

Un i fo rm Des ignThe outdoor units can be located on the rooftop. The uniform outlook and dimension allows side by side installation.

Qu ie t Opera t ionThe condensing unit utilises an advanced spiral fan blades. The smooth material and fan blade design help to reduce the turbulent flow and thus reduce the air flow noise. Besides that, a in-house designed compressor jacket also contributes in reducing the noise from the compressor.

Unique Return Oil Technology

The brain of the A5MDS system is the compressor which is incorporated in theoutdoor condensing unit. With this technology, the outdoor is constructed in a uniform and solid design

and focusing on smaller footprint to provide better space utilisation.

O u t d o o r F e a t u r e s

12

Rel iab le Techno logyA5MDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly. • A5MDS system has better oil return performance even at low capacities, which will make sure that all of the removable parts of the compressor can be lubricated and cooled down. • It reduces the start/stop times, which will reduce the attack to the electricity supply net. • The PWM (Pulse Width Modulation) valve has the longevity of 40 million times. • The design is simple and there is no requirment for bypass valve.

Page 14: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

NanoPhotocatalyst -deVOCs & deodorization(150 times stronger than highperformance activated carbon)

NanoSilver-bacteria &germs elimination

Pre Filter

Wal

l Mou

nted

G S

erie

sI n d o o r F e a t u r e s

Acson is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoShield combines powerful sterilizing and deodorizing effect of NanoSilver and Nano-Photocatalyst.

Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into anti-bacterial applications ever since. Modern nanotechnology provides through full-infusion onto the filters and larger coated surface area.

13

A5WMD 09/10/15/20/25 G

Cool ing 8,500 Btu/h – 22,200 Btu/h2.5 kW – 6.5 kW

Heat ing 9,600 Btu/h – 25,200 Btu/h2.8 kW – 7.4 kW

Double Louver This new louver design together with its automatic air swing function fully optimizes the room comfort by distributing the air evenly to every corner of the room.

3-Fold Heat Exchanger The compact design of this 3-fold structure providesa large surfacearea for better &efficient heatexchange.

New Aesthetically Outlook A smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design. The centrally located LED light makes it easier for user to check the operating conditions.

Page 15: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

4 Way A i r D ischarge And A i r SwingIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.

Sty l i sh And S l im Pane lThe slim panel can be blended easily into most interiordecoration and design.

700mm

Bui l t - In H igh Head Dra in PumpThe unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.

Cei

ling

Cas

sette

A a

nd C

Ser

ies

14

A5CKD 10/15/20 CA5CKD 20/25/30/40/50 ACool ing 9,600 Btu/h – 47,800 Btu/h

2.8 kW – 14.0 kW

Heat ing 10,900 Btu/h – 54,600 Btu/h3.2 kW – 16.0 kW

Page 16: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Cei l ing and F loor Ins ta l la t ion Opt ionThe A5CMD is designed with the option to install either below the ceiling or mounted at low wall position to suit most interior design requirement.

700mm

F lex ib le Ins ta l la t ion The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.

Cei

ling

Con

vert

ible

E S

erie

s

15

A5CMD 15/20/25/28 E

Cool ing 12,300 Btu/h – 27,300 Btu/h3.6 kW – 8.0 kW

Heat ing 13,600 Btu/h – 30,700 Btu/h4.0 kW – 9.0 kW

Wall bracket supplied as optional item

Bet te r Serv iceab i l i t yThe washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access.

• Fan Motor• Blower• Wiring Connection

• Control Box• Piping Connection

Page 17: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

16

Automat ic A i r SwingThe swing mode enables the air flow to be evenly distributed into the room from the front discharge area.

Cei

ling

Con

vert

ible

D S

erie

s

Two Way A i r D ischargeEquipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.

Ce i l ing And F loor Ins ta l l ing Opt ionThe unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit most interior design requirements.

R5CMD 40/50 DR5CMD 62 CCool ing 38,200 Btu/h – 56,000 Btu/h

11.2 kW – 16.4 kW

Heat ing 42,700 Btu/h – 63,100 Btu/h12.5 kW – 18.5 kW

Page 18: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Primary Drain PanPolysterene (Ps) With Height Impact Polystyrene (Hips) Cover

Secondary Drain Pan With Insulation

Doub le Pro tec t ion Dra inage Sys temThe primary drain pan is designed with higher thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.

Duct Accessor ies (Opt iona l )A set duct accessories specifically designed to fit and to suit the A5CCD-C model is being created. Thus offers a one stop solution to installing the unit.

Available for A5CCD 10-25 C/CR only.

Cei

ling

Con

ceal

ed C

Ser

ies

Discharge Adaptor

Square GrilleAssembly c/w Adaptor

Secondary Drain Pan with Insulation

Primary Drain Pan

Square Return Grille Assembly

c/w Adaptor & Filter

FlexibleRound Duct(field supply)

Ceiling Concealed Unit

ACC Return AssemblyBracket c/w Adaptor

FlexibleRound Duct

(field supply)

F lex ib i l i t y In Sys tem Des ignThe unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system.

17

A5CCD 10/15/20/25/28/30/ 38/40/50/60 CCool ing 9,600 Btu/h – 56,000 Btu/h

2.8 kW – 16.4 kW

Heat ing 10,900 Btu/h – 63,100 Btu/h3.2 kW – 18.5 kW

Page 19: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

18

As a system provider, Acson R410A 5MDS system is equipped together with a collection of customized software to provide system design & selection and individual units control & monitoring.

I n t e g r a t e d S o f t w a r e

A5MDS Sys tem Management Sof twareFor central monitoring and control purposes, the A5MDS offers a real time system. This software is the system to human interface, allowing users or owners to monitor and to control the A5MDS system.

With this software, user or owners is able to ;• Monitor & control any A5MDS indoor & outdoor unit• Zoning & grouping capabilities• Alarming alert• Scheduling option

Des ign Sof twareThis software is incorporated with data on indoor models. This allow the designers to choose the appropriate indoors model to suit they needs. Besides that, this software will determine the required quantity of refnet joints, pipes and other accessories base on the design. With this software, most designs can be completed with just a few simple clicks.

Page 20: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

19

C o n t r o l l e r & A c c e s s o r i e s

Standard Controller

Optional Controller and Accessories

PC Control Refnet & Distributors Joint

A5MDS Central Monitoring Software (known as Smart Commander) act as the system to human interface. A communication gateway is inclusive

for the wiring connection.

Piping joint design for the A5MDS system. A total of 6 types of refnet joint is available for different

piping combination.

Optional Item. To providewireless control for wiredcontroller. Basic controlsuch as ON/OFF, modesetting, temperaturesetting and others.

AC 5300Optional Item. To providegroup or individual control to indoors within the same outdoor unit. Basic control such as ON/OFF, mode setting, temperature setting and others.

Central Controller

Wired ControllerWireless G12 Wireless G8

Standard wireless controller for A5WMD-G and A5CMD-E.

Basic control such as ON/OFF, mode setting, temperature

setting and others.

Standard wireless controller for A5CKD-A/C and R5CMD-D/C. Basic control such as ON/OFF,

mode setting, temperature setting and others.

Standard wired controller for A5CCD-C. Basic control such

as ON/OFF, mode setting, temperature setting and others.

Page 21: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

Shenzhen Xi Yuan, ChinaResidential SectorIndoor Type: Ceiling Concealed

Chendu Tian Fu Software Park, ChinaCommercial SectorIndoor Type: Ceiling Concealed

Pahang IKM Institute, MalaysiaEducation SectorIndoor Type: Ceiling Cassette, Wall Mounted

A5MDS systems has proven to be reliable and a system of choice.Many projects, whether government or privately own premises had chosen A5MDS as their comfort provider:

J o b R e f e r e n c e

Solar Alert Sdn. Bhd., MalaysiaCommercial SectorIndoor Type: Ceiling Cassette, Wall Mounted

20

Page 22: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

S1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

Outdoor Specifications

A5MDS 80BR A5MDS 100BR A5MDS 120BR A5MDS 140BR

Btu/h 85,300 95,536 112,596 129,656

W 25,000 28,000 33,000 38,000

Btu/h 95,536 109,184 126,244 143,304

W 28,000 32,000 37,000 42,000

COOLING W 7,200 8,000 9,700 11,300

HEATING W 7,000 7,900 9,400 10,900

A5MDS 80B A5MDS 100B A5MDS 120B A5MDS 140B

Btu/h 85,300 95,536 112,596 129,656

W 25,000 28,000 33,000 38,000

W 7,200 8,000 9,700 11,300

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A R-410A

l/s / cfm 3056 / 6474 3056 / 6474 3056 / 6474 3333 / 7063

dB(A) 56 57 60 60

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 290 / 639 300 / 661 305 / 672 350 / 771

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 9.52 / 3/8 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2

GAS mm/in 22.23 / 7/8 22.23 / 7/8 22.23 / 7/8 28.6 / 1 1/8

kg/lb 7.9 / 17.4 10.0 / 22.0 10.6 / 23.4 12.2 / 26.9

A5MDS 160BR A5MDS 180BR A5MDS 200BR A5MDS 220BR

Btu/h 143,304 160,364 180,836 197,896

W 42,000 47,000 53,000 58,000

Btu/h 160,364 180,836 201,308 221,780

W 47,000 53,000 59,000 65,000

COOLING W 12,900 14,500 16,200 17,700

HEATING W 11,900 13,800 14,700 16,900

A5MDS 160B A5MDS 180B A5MDS 200B A5MDS 220B

Btu/h 143,304 160,364 180,836 197,896

W 42,000 47,000 53,000 58,000

W 12,900 14,500 16,200 17,700

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A R-410A

l/s / cfm 3333 / 7063 3472 / 7357 3056 X 2 / 6474 X 2 2778 X 2 / 5886 X 2

dB(A) 60 61 61 62

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 1290 / 50.8 1290 / 50.8 1990 / 78.3 1990 / 78.3

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 360 / 793 370 / 816 590 / 1301 590 / 1301

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 12.7 / 1/2 12.7 / 1/2 15.88 / 5/8 15.88 / 5/8

GAS mm/in 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8

kg/lb 13.4 / 29.5 14.8 / 32.6 18.0 / 39.7 19.6 / 43.2

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY.

THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

SOUND PRESSURE LEVEL

UNIT DIMENSION

MODEL OUTDOOR UNIT

TYPE (LIQUID/GAS)

SIZE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

UNIT WEIGHT

AIR FLOW

PIPE CONNECTION

NOMINAL TOTAL INPUT POWER

POWER SOURCE

REFRIGERANT TYPE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

OU

TD

OO

R U

NIT

Page 23: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

S2

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY.

THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

A5MDS 240BR A5MDS 260BR A5MDS 280BR A5MDS 300BR

- A5MDS 120BRM + A5MDS 140BRS

A5MDS 120BRM + A5MDS 160BRS

A5MDS 120BRM + A5MDS 180BRS

Btu/h 218,368 242,252 255,900 272,960

W 64,000 71,000 75,000 80,000

Btu/h 242,252 266,136 279,784 296,844

W 71,000 78,000 82,000 87,000

COOLING W 19,800 21,000 22,600 24,200

HEATING W 18,500 20,300 21,300 23,200

A5MDS 240B A5MDS 260B A5MDS 280B A5MDS 300B

- A5MDS 120BM + A5MDS 140BS

A5MDS 120BM + A5MDS 160BS

A5MDS 120BM + A5MDS 180BS

Btu/h 218,368 242,252 255,900 272,960

W 64,000 71,000 75,000 80,000

W 19,800 21,000 22,600 24,200

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A R-410A

l/s / cfm 3056 X 2 / 6474 X 2 3056 + 3333 / 6474 + 7063 3056 + 3333 / 6474 + 7063 3056 + 3472 / 6474 + 7357

dB(A) 62 62 62 62

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 1990 / 78.3 2290 / 90.2 2290 / 90.2 2290 / 90.2

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 600 / 1323 655 / 1444 665 / 1466 675 / 1488

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8

GAS mm/in 28.6 / 1 1/8 34.9 / 1 3/4 34.9 / 1 3/4 34.9 / 1 3/4

kg/lb 21.5 / 47.4 22.8 / 50.3 24.0 / 52.9 30.0 / 66.1

A5MDS 320BR A5MDS 340BR A5MDS 360BR A5MDS 380BRA5MDS 180BRM + A5MDS 140BRS

A5MDS 180BRM + A5MDS 160BRS

A5MDS 180BRM + A5MDS 180BRS

A5MDS 240BRM + A5MDS 140BRS

Btu/h 290,020 303,668 320,728 348,024

W 85,000 89,000 94,000 102,000

Btu/h 324,140 341,200 361,672 385,556

W 95,000 100,000 106,000 113,000

COOLING W 25,800 27,400 29,000 31,100

HEATING W 24,700 25,700 27,600 29,400

A5MDS 320B A5MDS 340B A5MDS 360B A5MDS 380BA5MDS 180BM + A5MDS 140BS

A5MDS 180BM + A5MDS 160BS

A5MDS 180BM + A5MDS 180BS

A5MDS 240BM + A5MDS 140BS

Btu/h 290,020 303,668 320,728 348,024

W 85,000 89,000 94,000 102,000

W 25,800 27,400 29,000 31,100

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A R-410A

l/s / cfm 3472 + 3333 / 7357 + 7063

3472 + 3333 / 7357 + 7063 3472 X 2 / 3753 X 2 3056 X 2 + 3333 / 6474 X 2 + 7063

dB(A) 63 63 63 64

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 2590 / 102.0 2590 / 102.0 2590 / 102.0 3290 / 129.5

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 720 / 1587 730 / 1609 740 / 1631 950 / 2094

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 19.05 / 3/4 19.05 / 3/4 19.05 / 3/4 19.05 / 3/4

GAS mm/in 34.9 / 1 3/4 34.9 / 1 3/4 34.9 / 1 3/4 41.3 / 1 5/8

kg/lb 32.0 / 92.6 34.0 / 75.0 34.0 / 75.0 38.0 / 83.4

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

REFRIGERANT CHARGE

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

POWER SOURCE

REFRIGERANT TYPE

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

AIR FLOW

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

OU

TD

OO

R U

NIT

OU

TD

OO

R U

NIT

Page 24: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

S3

A5MDS 400BR A5MDS 420BR A5MDS 440BR

A5MDS 240BRM + 5MDS 160BRS A5MDS 240BRM + 5MDS 180BRS A5MDS 240BRM + 5MDS 200BRS

Btu/h 361,672 378,732 399,204

W 106,000 111,000 117,000

Btu/h 402,616 423,088 443,560

W 118,000 124,000 130,000

COOLING W 32,700 34,300 36,000

HEATING W 30,400 32,300 33,200

A5MDS 400B A5MDS 420B A5MDS 440B

A5MDS 240BM + 5MDS 160BS A5MDS 240BM + 5MDS 180BS A5MDS 240BM + 5MDS 200BS

Btu/h 361,672 378,732 399,204

W 106,000 111,000 117,000

W 32,700 34,300 36,000

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A

l/s / cfm 3056 X 2 + 3333 / 6474 X 2 + 7063 3056 X 2 + 3472 / 6474 X 2 + 7357 3056 X 4 / 6474 X 4

dB(A) 65 65 65

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 3290 / 129.5 3290 / 129.5 3990 / 129.5

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 960 / 2116 970 / 2138 1190 / 2624

Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 19.05 / 3/4 19.05 / 3/4 19.05 / 3/4

GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8

kg/lb 40.0 / 88.2 42.0 / 92.6 44.0 / 97.0

A5MDS 460BR A5MDS 480BR A5MDS 500BR

A5MDS 240BRM + 5MDS 220BRS A5MDS 240BRM + 5MDS 240BRS A5MDS 250BRM + 5MDS 250BRS

Btu/h 416,264 436,736 457,208

W 122,000 128,000 134,000

Btu/h 464,032 484,504 504,976

W 136,000 142,000 148,000

COOLING W 37,500 39,600 41,800

HEATING W 35,400 37,000 39,000

A5MDS 460B A5MDS 480B A5MDS 500B

A5MDS 240BM + 5MDS 220BS A5MDS 240BM + 5MDS 240BS A5MDS 250BM + 5MDS 250BS

Btu/h 416,264 436,736 457,208

W 122,000 128,000 134,000

W 37,500 39,600 41,800

V/Ph/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

R-410A R-410A R-410A

l/s / cfm 3056 X 4 / 6474 X 4 3056 X 4 / 6474 X 4 3056 X 4 / 6474 X 4

dB(A) 65 65 65

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 3990 / 129.5 3990 / 129.5 3990 / 129.5

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 1190 / 2624 1200 / 2646 1220 / 2690

Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 19.05 / 3/4 19.05 / 3/4 19.05 / 3/4

GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8

kg/lb 46.0 / 101.4 48.0 / 105.8 50.0 / 110.2

NOMINAL TOTAL INPUT POWER

AIR FLOW

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

REFRIGERANT CHARGE

REFRIGERANT TYPE

OUTDOOR UNIT

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

AIR FLOW

POWER SOURCE

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

UNIT DIMENSION

UNIT WEIGHT

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

PIPE CONNECTION

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OUTDOOR UNIT

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY.

THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

OU

TD

OO

R U

NIT

OU

TD

OO

R U

NIT

Page 25: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

S4

Indoor SpecificationsIN

DO

OR

UN

ITIN

DO

OR

UN

ITA5WMD-G

A5WMD 09G A5WMD 10G A5WMD 15G

Btu/h 8500 9600 12300

W 2500 2800 3600

Btu/h 9600 10900 13600

W 2800 3200 4000

24 26 29W

V/Ph/Hz

HIGH l/s / cfm 130 / 275 142 / 300 163 / 345

MEDIUM l/s / cfm 106 / 225 118 / 250 135 / 285

LOW l/s / cfm 83 / 175 94 / 200 104 / 220

dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29

HEIGHT mm/in

WIDTH mm/in 799 / 31.5

DEPTH mm/in

kg/lb 10/22.05

LIQUID mm/in

GAS mm/in 12.7 / 1/2

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.

A5WMD-G

A5WMD 20G A5WMD 25G

Btu/h 19100 22200

W 5600 6500

Btu/h 21500 25200

W 6300 7400

47 66W

V/Ph/Hz

HIGH l/s / cfm 231 / 490 397 / 630

MEDIUM l/s / cfm 193 / 410 231 / 490

LOW l/s / cfm 160 / 340 208 / 440

dBA 43 / 40 / 35 49 / 44 / 42

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb

LIQUID mm/in

GAS mm/in 12.7 / 1/2

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.

16 / 35.27

FLARE VALVE

6.4 / 1/4

15.9 / 5/8

220-240/1/50

304 / 12.0

1062 / 41.8

222 / 8.7

INDOOR MODEL

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

220-240/1/50

FLARE VALVE

SIZE9.5 / 3/8

12/26.46

899 / 35.4

POWER SOURCE

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

6.4 / 1/4

UNIT DIMENSION

AIR FLOW

INDOOR MODEL

260 / 10.2

198 / 7.8

PIPE CONNECTION

TYPE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

POWER SOURCE

AIR FLOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

Page 26: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

S5

A5CKD-C

A5CKD 10C A5CKD 15C A5CKD 20C

Btu/h 9600 12300 19100

W 2800 3600 5600

Btu/h 10900 13600 21500

W 3200 4000 6300

W 16 18 22

V/Ph/Hz

l/s / CFM 189 / 400 194 / 410 212 / 450

l/s / CFM 184 / 390 184 / 390 203 / 430

l/s / CFM 175 / 370 170 / 360 194 / 410

dBA 44 / 43 / 42 44 / 42 / 41 47 / 46 / 44

mm/in

mm/in

mm/in

kg/lb 22 + 2 / 48.5 + 4.4 23.2 / 50.7 + 4.4 23 + 2 / 50.7 + 4.4

FLARE VALVE

LIQUID mm/in 6.4 / 1/4

GAS mm/in 9.5 / 3/8 12.7 / 1/2 12.7 / 1/2

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.

UNIT WEIGHT (UNIT + PANEL)

PIPE CONNECTION

TYPE

220 - 240 / 1 / 50

250 (295) / 9.8 (11.6)

570 (640) / 22.4 (25.2)

570 (640) / 22.4 (25.2)

FLARE VALVE

SIZE

DEPTH

LOW

UNIT DIMENSION ( ) - WITH PANEL

IND

OO

R U

NIT

IND

OO

R U

NIT

POWER SOURCE

AIR FLOW

HIGH

SOUND PRESSURE LEVEL (H/M/L)

HEIGHT

WIDTH

INDOOR MODEL

MEDIUM

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

A5CKD-A

A5CKD 20A A5CKD 25A A5CKD 30A A5CKD 40A A5CKD 50A

Btu/h 19100 22200 30700 38200 47800

W 5600 6500 9000 11200 14000

Btu/h 21500 25200 34100 42700 54600

W 6300 7400 10000 12500 16000

W 35 45 60 83 120

V/Ph/Hz

l/s / CFM 349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040

l/s / CFM 297 / 630 311 / 660 349 / 740 406 / 860 448 / 950

l/s / CFM 283 / 600 283 / 600 321 / 680 359 / 760 411 / 870

dBA 42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50

mm/in

mm/in

mm/in

kg/lb 31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8

LIQUID mm/in 6.4 / 1/4 6.4 / 1/4 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8

GAS mm/in 12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) FOR A5CK 20/25 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA. FOR A5CK 30/40/50 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.

820 (930) / 32.2 (36.6)

NOMINAL TOTAL INPUT POWER

220-240/1/50

335 (363) / 13.2 (14.3)

820 (930) / 32.2 (36.6)

HIGH

MEDIUM

INDOOR UNIT

HEIGHT

SOUND PRESSURE LEVEL (H/M/L)

DEPTH

PIPE CONNECTION

TYPE

SIZE

FLARE VALVE

INDOOR MODEL

LOW

POWER SOURCE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

WIDTH

AIR FLOW

WEIGHT (UNIT + PANEL)

UNIT DIMENSION ( ) - WITH PANEL

Page 27: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

S6

IND

OO

R U

NIT

IND

OO

R U

NIT

A5CMD-E

A5CMD 15E A5CMD 20E A5CMD 25E A5CMD 28E

Btu/h 12300 19100 22200 27300

W 3600 5600 6500 8000

Btu/h 13600 21500 25200 30700

W 4000 6300 7400 9000

W 79 101 109 150

V/Ph/Hz

l/s / CFM 240 / 508 245 / 520 274 / 580 293 / 620

l/s / CFM 182 / 386 217 / 460 250 / 530 269 / 570

l/s / CFM 165 / 350 192 / 406 231 / 490 245 / 520

dBA 46 / 38 / 35 50 / 43 / 41 53 / 51 / 49 56 / 51 / 44

mm/in

mm/in

mm/in

kg/lb 26 / 57 27 / 60 27 / 60 28 / 62

LIQUID mm/in 9.52 / 3/8

GAS mm/in

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.

LOW

NOMINAL COOLING CAPACITY

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

HIGH

MEDIUM

NOMINAL HEATING CAPACITY

POWER SOURCE

218 / 8.58

PIPE CONNECTION

TYPE

SIZE

UNIT WEIGHT

1080 / 42.52

630 / 24.80

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

220 - 240 / 1 / 50

FLARE VALVE

INDOOR UNIT

NOMINAL TOTAL INPUT POWER

12.7 / 1/2

6.35 / 1/4

UNIT DIMENSION

15.9 / 5/8

R5CMD-D/C

R5CMD 40D R5CMD 50D R5CMD 62C

Btu/h 38200 47800 56000

W 11200 14000 16400

Btu/h 42700 54600 63100

W 12500 16000 18500

W 153 171 327

V/Ph/Hz

l/s / CFM 477 / 1010 491 / 1040 732 / 1550

l/s / CFM 420 / 890 448 / 950 623 / 1320

l/s / CFM 368 / 780 387 / 820 472 / 1000

dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46

mm/in 285 / 11.2

mm/in 1903 / 74.9

mm/in 680 / 26.8

kg/lb 85 / 187.4

LIQUID mm/in

GAS mm/in 19.1 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.

670 / 26.30

220 - 240 / 1 / 50

PIPE CONNECTION

TYPE

SIZE

70 / 154.3

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

AIR FLOW

HIGH

MEDIUM

LOW

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

249 / 9.80

INDOOR UNIT

FLARE VALVE

9.52 / 3/8

15.9 / 5/8

1714 / 67.40

POWER SOURCE

INDOOR MODEL

Page 28: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

A B C D E F G

Specification for AMDS

AMDS080BR AMDS100BR

Btu/h 83,594 95,536

W 24,500 28,000

Btu/h 88,712 102,360

W 26,000 30,000

W 7,500 8,500

W 7,200 8,300

AMDS080B AMDS100B

Btu/h 83,594 95,536

W 24,500 28,000

W 7,500 8,500

V/Ph/Hz 380/3/50 380/3/50

R22 R22

HI-FAN l/s / cfm 3194/6768 3194/6768

LOW-FAN l/s / cfm 1528/3237 1528/3237

dB(A) 62 64

HEIGHT mm/in 1840/72.4 1840/72.4

WIDTH mm/in 990/39.0 990/39.0

DEPTH mm/in 840/33.0 840/33.0

kg/lb 275/606 385/628

Flare/Brazed Flare/Brazed

LIQUID mm/in 12.7/0.5 12.7/0.5

GAS mm/in 28.6/1.125 28.6/1.125

AMDS180BR AMDS200BR

Btu/h 162,070 170,600

W 47,500 50,000

Btu/h 170,600 180,836

W 50,000 53,000

W 14,100 15,200

W 13,200 14,700

AMDS180B AMDS200B

Btu/h 162,070 170,600

W 47,500 50,000

W 14,100 15,200

POWER SOURCE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

OUTDOOR UNIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

S7

Btu/h 9600 12300 19100 22200 27300

W 2800 3600 5600 6500 8000

Btu/h 10900 13600 21500 25200 30700

W 3200 4000 6300 7400 9000

W 65 96 135 152 300

V/Ph/Hz

l/s / CFM - - - - 401 / 850

l/s / CFM 142 / 300 241 / 510 330 / 700 345 / 730 382 / 810

l/s / CFM 123 / 260 208 / 440 321 / 680 340 / 720 363 / 770

l/s / CFM 104 / 220 170 / 360 293 / 620 274 / 580 335 / 710

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 49 / 39 / 29(0.2 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.3 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.4 / 0.3 / 0.3 / 0.2)

49 / 39 / 20 64 / 58 / 34 55 / 39 / 29 98 / 78 / 68 / 59

dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 44 / 41 / 38 / 34

mm/in 285 / 11.22

mm/in 765 / 30.12 905 / 35.63 1065 / 41.93 1200 / 47.24 1007 / 39.65

mm/in 600 / 23.62

kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 38 / 84

LIQUID mm/in 9.5 / 3/8

GAS mm/in 9.5 / 3/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.

220 - 240 / 1 / 50

PIPE CONNECTION

TYPE

SIZE15.9 / 5/8

WEIGHT

UNIT DIMENSION

LOW

SOUND PRESSURE LEVEL (SH/H/M/L)

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

HIGH

MEDIUM

NOMINAL TOTAL INPUT POWER

POWER SOURCE

AIR FLOW

SUPER HIGH

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

FLARE VALVE

411 / 16.18

6.4 / 1/4

12.7 / 1/2

261 / 10.28

Btu/h 30700 34100 38200 47800 56000

W 9000 10000 11200 14000 16400

Btu/h 34100 38200 42700 54600 63100

W 10000

460

11200 12500

510

16000 18500

W 503 515 659

V/Ph/Hz

l/s / CFM 604 / 1280 675 / 1430 812 / 1720

l/s / CFM 547 / 1160 623 / 1320 732 / 1550

l/s / CFM 496 / 1050 580 / 1230 632 / 1340

l/s / CFM 434 / 920 533 / 1130 552 / 1170

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 118 / 96 / 78 / 61 (0.5 / 0.4 / 0.3 / 0.2) (0.5 / 0.4 / 0.3 / 0.2) (0.6 / 0.5 / 0.4 / 0.3) (0.6 / 0.5 / 0.4 / 0.3)

147 / 126 / 109 / 92 147 / 120 / 90 / 69

dBA 52 / 49 / 48 / 45

566 / 1200

486 / 1030

406 / 860

349 / 740

120 / 86 / 64 / 45(0.5 / 0.3 / 0.3 / 0.2)

52 / 49 / 48 / 45 54 / 53 / 52 / 51

628 / 1330

571 / 1210

491 / 1040

425 / 900

120 / 98 / 74 / 54

51 / 49 / 45 / 41 54 / 52 / 50 / 46

mm/in 378 / 14.88 305 / 12.0 378 / 1488 378 / 14.9 378 / 14.9

mm/in 929 / 36.57 1302 / 51.3 1045 / 14.14 1299 / 51.1 1499 / 59.0

mm/in 514 / 21.3 638 / 25.1 541 / 21.3 541 / 21.3 541 / 21.3

kg/lb 39 / 86 41 / 90 42 / 92.6 54 / 119 62 / 137

LIQUID mm/in

GAS mm/in 19.05 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.

220 - 240 / 1 / 50

AIR FLOW

LOW

POWER SOURCE

HIGH

PIPE CONNECTION

TYPE

SIZE

DEPTH

WEIGHT

UNIT DIMENSION

9.5 / 3/8

15.9 / 5/8

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

MEDIUM

SUPER HIGH

NOMINAL TOTAL INPUT POWER

HEIGHT

SOUND PRESSURE LEVEL (SH/H/M/L)

WIDTH

INDOOR MODEL

FLARE VALVE

IND

OO

R U

NIT

IND

OO

R U

NIT

A5CCD-C

A5CCD 10C A5CCD 15C A5CCD 20C A5CCD 25C A5CCD 28C

A5CCD-C

A5CCD 30C A5CCD 38C A5CCD 40C A5CCD 50C A5CCD 60C

Page 29: R-410A Multi Digital Scroll System - Acson International SELLING KIT/CATALOG/AP... · Comsumption = 0% A5MDS System Traditional Inverter System A5MDS100BR IPLV Testing 2 2.5 3 3.5

AP-A5MDS-08A

Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.

For the most up-to-date product information, please go to www.acson-international.com.

www.acson-international.com©2008 Acson International