8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 1A Setup Fill the reservoir The removable reservoir is translucent for you to see the water levels. 1. Fill the reservoir with five liters of sterile distilled water. Do not fill past the fill line to avoid water overflow. 2. If you remove the reservoir from the controller to fill it with sterile distilled water, replace it by gently lowering the reservoir back into position. Make sure that it is secure. Power on 1. Plug the power cord into a wall outlet. 2. Tap the Stand-by button to start the product. A • Always use sterile distilled water or water that has been passed through a filter less than or equal to 0.22 microns with this product. Always fill the reservoir with room temperature sterile distilled water to reduce the risk of burn. Do not overfill the reservoir to avoid the risk of water spillage and fall. Caution ! Quick start guide for Altrix Precision Temperature Management System

Upload: others

Post on 28-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 1A

Quick start guide forAltrix™ Precision Temperature Management System

Setup

Fill the reservoir

The removable reservoir is translucent for you to see the water levels.

1. Fillthereservoirwithfivelitersofsteriledistilledwater.Donotfillpastthefilllinetoavoidwateroverflow.

2. If you remove the reservoir from thecontrollertofillitwithsteriledistilledwater,replaceitbygentlyloweringthereservoirbackintoposition.Makesurethatitissecure.

Power on1. Plugthepowercordintoawalloutlet.2. TaptheStand-bybuttontostarttheproduct.

A

• Always use sterile distilled water or water that has been passedthroughafilterlessthanorequalto0.22micronswiththisproduct.

• Alwaysfillthereservoirwithroomtemperaturesteriledistilled water to reduce the risk of burn.

• Donotoverfillthereservoirtoavoidtheriskofwaterspillageandfall.

Caution!

Quick start guide forAltrix™ Precision Temperature Management System

Page 2: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 2A

Connecting thermal transfer devices

TherearetwoconnectortypesforStryker’sthermaltransferdevices:Clik-Titeandcolderstyle.

Pre-filling the thermal transfer devices

1. Openalloftheclampsontheconnectorhoseandthermaltransfer device.

2. Makesurethatthecontrollerispowered.

3. TaptheManualmodebutton.4. TapConfirm.5. Selectawatertemperaturethatalignswithyourtargetpatienttemperature.Allowthewatertoflowfromthecontrollerintothethermal transfer device until full.

6. TapConfirm.

Connecting patient temperature probe• AlignthereddotontheReusableAdapterCable(B)tothecontroller(A) probeportAorB.

• Connecttheplug(C)tothepatienttemperatureprobe.

Selecting primary probe1. TaptheSettingsbutton.2. TapSelectProbetodisplaytheSelectPrimaryProbe(ProbeAorProbeB)screenNote:Primaryprobewilldefaultto Probe A.

3. TapConfirm.

Connecting patient temperature output cable ThisfeatureallowstheoperatortoviewthetemperatureontheAltrixsystemandonaseparatedevice.

• Insertthereusablepatienttemperatureoutputcableintothepatienttemperatureoutputport,located in between the Probe A andProbeBports.

AlwaysuseStrykeraccessories.Failuretocomplywiththese instructions may invalidate any or all warranties and may negativelyaffecttheproductsEMCperformance.Thisalso protectstheproductfromcardiacdefibrillation.

Patient temperature

ptrobe

Reusableadaptercable

Probeport(AorB)

Colder style

Clik-Tite

Caution!

Caution!Alwayspre-fillthethermaltransferdevicewithsteriledistilledwaterbeforeyouapplyittothepatient.Thisistoreducetherisk ofpressureinjuries.

Page 3: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 3A

Initiation of therapy

Selecting a therapy modeYoucanselectfromoneofthesethreemodes:

• Automatic(therapy)• Manual(therapy)• Monitor(non-therapy)

Automatic therapyInAutomaticmode,thetherapycoolsorwarmsthepatienttoaselectedpatienttargettemperature.Theproductcontinuallymeasuresthepatienttemperatureandautomaticallyadjuststhewatertemperatureuntiltheselectedpatienttargettemperatureisachieved.

Cooling

Warming

SelectAutomatictherapymodeandconfirm

PressEdit

SelectTargetTemperatureandconfirm

SelectTargetTemperatureandconfirm

SelectMax,Med,Min andconfirm

SelectMax,Med,MinorCustomandconfirm

Quick start guide forAltrix Precision Temperature Management System

Page 4: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 4A

Manual therapyInManualmode,theproductcontrolsthewatertemperatureonly.Atemperatureprobeisnotrequiredwhenoperatinginmanualmode.

Display the patient data graph

Todisplaythepatientdatagraph,tapthegraphicon. Thepatientdatagraphstoresthefollowingvariables:

• Primarypatienttemperaturereading(A)• Intermediatetargettemperature(B)• Watertemperature(C)• Powerlevel(D)

Pause therapy

• Topausetherapy,pressandholdthePauseTherapybutton for two seconds.

• Toresumetherapy,pressandholdthePauseTherapybutton for two seconds.

Stop therapy

• PressandholdtheStand-bybuttonfortwoseconds.• Unplugtheproductfromthewalloutlet.• Opentheclampsforapproximately10minutestoallow

the water to drain back into the controller.• Closeclampstostopthewaterflowanddetachwrapsfromhoses.

A

B

C

D

Select Manual therapy mode and confirm

Select desired water temperature

Page 5: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 5A

Product functions

Icon Name Function

Stand-by Pressandholdthebuttonfortwosecondstostoptherapyorpoweroff

Therapypaused Pressandholdthebuttonfortwosecondstopauseorresumetherapy

Viewtemperature SelecttemperaturedegreeinCelsiusorFahrenheit

Lock / unlock screen Pressandholdthebuttonfortwosecondstolockorunlockthegraphicaluser interface

Audiopaused Pauseorresumetheaudibleindicatorwhenanalarmisactive.Silenceseachalarmforfiveortenminutesdependingonthealarmcondition.Thisbuttonbreathes¹toindicatethatitisinapausedstate.

Automatictherapymode Coolsorwarmsthepatienttoaselectedpatienttargettemperature

Manualtherapymode Coolsorwarmsthewatertoaselectedwatertargettemperature

Monitoronlymode Displaysthecurrentpatienttemperature(notherapy)

Thegraphicaluserinterfaceshownisforreferenceonly.Theimageshowswhereyouwillseetheiconsandbuttons illuminate when they are active. At no time will you see all of these icons at the same time.

Quick start guide forAltrix Precision Temperature Management System

Page 6: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 6A

Icon Name Function

Increase Increasesthewaterorpatienttemperatureby0.1°forcoolingorwarmingtemperature Note:Pressandholdtheincreasebuttontomovethetemperatureupfaster.

Decrease Decreasesthewaterorpatienttemperatureby0.1°forcoolingorwarmingtemperature Note:Pressandholdthedecreasebuttontomovethetemperaturedown

Back Returnstothepreviousscreenorcancelanoperation

Editsettings,Exit,orCancel Editcurrentsettings,exit,orcancel.

Confirmselection Acceptstheselectedsettings

NextorMore Changestothenextscreen,option,orsetting

Pageindicators(mayalsoappearvertical)

Indicatesthatthereismorethanonepageassociatedwiththescreentopicforthepagethatiscurrentlydisplayed

Settings Displaysthesummaryofthecurrent,visual/audible,language,orprimaryprobesettings

Graph Graphicaldisplayoftheselecteditemssuchaspatienttemperature,targettemperature,watertemperature,andpowerlevel

Help Displayscontextualhelpscreensfortherapies,navigation,buttons, and alarm screens

¹Breathe:Thebrightnessofthebuttonoriconwillgotoalowlightandthenincreasetoabrightlight.Thiscyclerepeats.

Product functions(continued)

Page 7: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 7A

Icon Function

Watertemperatureontarget,solidgreenwhenactive,doesnotbreathe

Patienttemperatureontarget

PatientprobeAport,stabilized

PatientprobeBport,stabilized

Externaldevice,patientprobeA

Externaldevice,patientprobeB

Stand-by

Icon Function

Waterflowdetected,ports1,2,or3areactive,solidgreenwhenactive,does not breathe

Coolingtherapy

Warmingtherapy

Currenttherapyduration

Total duration

Visual and audible tests

Targetpatientorwatertemperature

Product functions(continued)

Quick start guide forAltrix Precision Temperature Management System

Page 8: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 8A

Alarms

Icon Name Alarm priority Message Therapy

interrupted Check

Watertemperaturedeviation

Medium Watertemperatureis±0.8°C(1.4°F)outsideoftargettemperature

No Temporaryconditionuponstartup,additionfthermaltransferdevice,oraddition of water

No water Medium No water Yes Check for leaks Add a minimum of 2 liters of sterile distilled water

Nowaterflow Medium Noflowdetected Yes Checkforleaksandobstructionsatconnections,hoses,andthermaltransfer devices

Checkwaterflowonanyport

Medium Reducedflowdetected No TapConfirm,ifthewaterportwasremovedintentionallyCheckforleaksandobstructionsatconnections,hoses,andthermaltransferdevices

Power loss Medium Notapplicable Yes Checkpowercordconnection

Checkpatientprobe(AorB)

Medium Abnormalchangeinpatienttemperature

Yes Checkprobecondition,location,andconnections

Probeoradaptermalfunction(AorB)

Medium Notemperaturesignaldetected Yes Checkprobeoradaptercablecondition,location,andconnections

Adaptercabledisconnected(AorB)

Medium Adaptercablenotdetected Yes Reinserttheadaptercable.Ifdamaged,replacetheadaptercable

Patienttemperaturedeviation

Medium Patienttemperatureis±0.5°C(0.9°F)outsideoftargettemperature

No Checkpatientcondition,placementofthermaltransferdevices,andallconnections

Normothermia deviation

Low Patienttemperatureisoutsideof36.0°C(96.8°F)to38.0°C(100.4°F)

No Checkpatientcondition,placementofthermaltransferdevices,andallconnections

Therapypause Medium Therapyiscurrentlypaused Yes Toresume,pressandholdtheplay/pausefor2seconds

Batterylow Low Batteryislow No Maintenanceisrecommended.Ifbatteryisnotreplaced,theproductmaynotfunctiononthenextstartup.

Patienttemperatureoutput(AorB)

Low Patienttemperatureoutputisinaccurateontheexternaldevice,oroutsidesupportedrange

No Checkoutputadaptercableconnection.TapConfirmtoreactivatetheoutputport.

Removefromuse(RFU)

Medium Thesystemhaspoweredoffduetoa malfunction

Yes Removetheproductfromuseimmediately.Notifytheappropriatepersonnel.

Ifanyofthealarmconditionspersist,callmaintenance.Ifthepageindicatorsappearonthealarmscreen,therearemultipleactivealarms.Onlythehighestalarmisdisplayed.

Page 9: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 9A

Quick start guide forAltrix Precision Temperature Management System

DisinfectingDisinfect the internal water circuit and hoses every 14 daysUsetheBruCleanTbCdisinfectanttabletsbyBrulin(EPAregistrationnumber71847-2-106)beforefirstuse,atleastevery14days,andbeforestorage.BruCleanTbChasbeenvalidatedforinternalwatercircuitdisinfection.Makesurethatyoufollowthedisinfectantmanufacturer’sguidelinestoavoidtheriskofinjury.Failuretofollowthedisinfectant’sinstructions may void your warranty.

Caution!• Alwaysusesteriledistilledwaterorwaterthathasbeenpassedthroughafilterlessthanorequalto0.22micronswiththisproduct.

• Do not disinfect the internal water system with a thermal transfer device attached as this may cause a leak.

• Donotusebleachoranyothercleaningordisinfectantagentsfor internalcircuits.Thiscouldresultindamagetotheproduct.Onlyuseapproveddisinfectanttablets.

• Alwaysdraintheproductbeforedisinfectingtheinternalwatercircuit.Failuretodraintheproductmayreducetheeffectivenessofthedisinfectionprocess.

Tools required:• 2gallons(11.4L)ofsteriledistilledwaterorwaterthathasbeenpassedthroughafilterlessthanorequalto0.22microns

• Personalprotectionequipment(PPE)asrecommendedbythedisinfectantmanufacturer’sinstructions

• Soft,lintfreecloth(2ormore)• 2BruCleanTbC13.1gtablets(ActiveingredientNaDCCsolutionppm=1874mg/L)Note:BruCleanTbCisablendof48%sodiumdichloroisocyanturateandAdipicAcidwitha5%sodiumdodecylbenzenesulphonatesurfactant.

• Servicetooladapterhose(8001-999-017)forColderstyleconnectorhoses• Floor drain

SeeProductillustrationonpage10ofthemanualforclarificationofproductcomponentnamesandlocations.

Draining the internal water circuit and hoses for disinfection1. Unplugthepowercordfromthewalloutlet.2. Placethecontrolleroverafloordrain.Note:Forbestresults,thefloordrainshouldbewithinreachofawalloutlettopoweronthecontroller.

3. Todrainthecontroller,pulluponthecontrollerdrainplug(A)toopenthedrain(Figure24).Leavethedrainopen. Figure 24

Note: Disinfection oftheAltrixinternal water system was validatedusing M. mucogenicum.

Page 10: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 10A

Draining the internal water circuit and hoses for disinfection (cont.)

Figure 25 Figure 27 Figure 28Figure 26

4. Connectahosetoeachport(Figure25).5. Closetheconnectorendsofallthreehoses:a. IfyouhaveColderstyleconnectorhoses,attachtheservicetooladapterhose(8001-999-017)(Figure26).Completethisforallthreehoses.

b. IfyouhaveClik-Titehoses,makesurethattheconnectorendsareconnectedandclosed(A),andclampsareopen(B).Completethisforallthreehoses(Figure27).

6. Tofullydrainthehoses,raiseallthehoses(Figure28)abovetheconnectionportsonthecontroller.Note:Forbestperformance,hangthehosestokeepthemraised.Donotlowerthehosesuntilyouhavecompletedthedisinfectionandrinsingprocess.

7. Allow the controller and hoses to drain for a minimum of two minutes.8. Pushdownonthedrainplugtoclosethedrain.

1. UsepersonalprotectionequipmentasrecommendedbytheBruCleanTbCdisinfectantmanufacturer’sinstructionsforuse.

2. Put2BruCleanTbCtabletsintothereservoir.3. Usingappropriatemeasuringequipment,filltheemptyreservoirwith1gallon(3.8L)ofsterile-distilledwater.Note: Alwaysallowthedisinfectanttabletstocompletelydissolvebeforestartingthe20minutedisinfectioncycle.

4. Place the reservoir into the controller.5. Disconnectthebottomhosefromthebottomrightport(Figure29).6. Connect the bottom hose end to the hydraulic connector in the lid of thereservoir(Figure30).

7. Plugthepowercordintoawalloutlet.

Figure 29 Figure 30

Disinfecting the internal water circuit and hoses

Page 11: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 11A

Quick start guide forAltrix Precision Temperature Management System

8. Press andholdtheStand-bybutton.

9. Tap theManualmodeicon.

10. TapConfirm.11. Setthewatertargettemperatureto25.0°C(77.0°F).

12. TapConfirm.

13. Runthecontrollerfor20minutes.14. After20minutes,turnthecontrolleroffbypressingandholdingthe

Stand-bybuttonfortwoseconds.15. Unplugthepowercordfromthewalloutlet.16. Placethecontrolleroverafloordrain.17. Removethereservoir.Pullforwardatanangle,andliftoutthe

reservoir.18. Removethebottomhoseendfromthehydraulicconnectoradapterin

thereservoirlidbypushingdownonthecollar.19. Emptywaterfromthereservoir,disposeofthewater

perhospitalprotocol.

20. Pulluponthecontrollerdrainplug(Figure31)toopenthedrain.

21. Makesurethatall3hosesremainraisedabovetheconnectionportsfordraining.

22. Allow the controller and hoses to drain for a minimum of two minutes.23. Pushdownonthecontrollerdrainplugtoclosethedrain.24. Whenthecontrollerandhosesaredrained,continuetoRinsingthe

internal water circuit and hoses.

Disinfecting the internal water circuit and hoses (cont.)

Figure 31

Page 12: Quick start guide for Altrix Precision Temperature ...€¦ · 162 Rev B. Refer to the Altri P recision Temerature anaement ystem erations anual for additional information. card 1A

8001-069-002 Rev B.2 Refer to the Altrix Precision Temperature Management System Operations Manual for additional information. card 12A

1. Usingappropriatemeasuringequipment,filltheemptyreservoirwith1gallons(3.8L)ofsterile-distilledwater.

2. Place the reservoir into the controller.3. Connect the bottom hose end to the hydraulic connector in the lid of

thereservoir(Figure32).4. Plugthepowercordintoawalloutlet.

5. PressandholdtheStand-bybutton.

6. TaptheManualmodeicon.

7. TapConfirm.8. Selectthewatertargettemperatureof25.0°C(77.0°F).

9. TapConfirm.

10. Allowthecontrollertorunfor5minutes.Note:Thetimerwillrunonthemaindisplay,followthecurrenttherapydurationtimer.

11. After5minutes,turnthecontrolleroffbypressingandholdingthe

Stand-bybuttonfortwoseconds.12. Unplugthepowercordfromthewalloutlet.13. Placethecontrolleroverafloordrain.14. Removethereservoir.Pullforwardatanangle,andliftoutthereservoir.

15. Removethebottomhoseendfromthehydraulicconnectoradapterinthereservoirlidbypushingdownonthecollar.

16. Emptywaterfromthereservoir,disposeofthewaterperhospitalprotocol.

17. Pulluponthecontrollerdrainplugtoopenthedrain.18. Makesurethatall3hosesremainraisedabovetheconnectionports

fordraining.19. Allowthecontrollerandhosestodrainforaminimumoftwominutes.20. Pushdownonthecontrollerdrainplugtoclosethedrain.21. Wipetheinsideandoutsideofthereservoirandreservoirlid,withadry,

soft,lintfreecloth.22. Place the reservoir into the controller.23. Disconnectandstoretheservicetooladapterhosesfromallthreeofthe

hoses.(Ifapplicable,whenusedwithcolderstylehoses.)24. Storethepowercord,cables,andhoses.

Rinsing the internal water circuit and hoses