80114-261 02.16 ELECTROSURGERY QUICK GUIDE VIO ® 300 S This quick guide is no substitute for briefing and user manual. This quick guide does not include any safety notes. Make yourself familiar with the safety notes in the user manuals. Necessary operating steps Check the settings of the instrument receptacles used by pressing their focus buttons one by one. Only if you are using a monopolar instrument. The long edge of the return electrode (1) must point to the operating field. Following application and during surgery. If the red return electrode symbol lights up, check the following: Is the return electrode correctly connected to the device? Does the long edge of the return electrode point to the operating field? Does the return electrode have sufficient contact to the skin? ! 1 Switch on the device 2 Select and adopt program 3 Check settings max. Watts COAG + + CUT max. Watts + + Prog/ Setup HIGH CUT FORCED COAG 2 MONOPOLAR Effect max. W atts max. W atts Effect 4 Apply and connect return electrode 5 Monitor return electrode Correct Error 6 Connect instruments ATTENTION: You may only plug monopo- lar 4 mm Ø connectors into the receptacle with the blue ring (1). Otherwise you damage the device. 1 1

Upload: others

Post on 19-Mar-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QUICK GUIDE VIO 300 S - Erbe Med · VIO® 300 S This quick guide is no substitute for briefing and user manual. This quick guide does not include any safety notes. Make yourse lf

80114-261 02.16ELECTROSURGERY

QUICK GUIDEVIO® 300 S

This quick guide is no substitute for briefing and user manual. This quick guide does not include any safety notes. Make yourself familiarwith the safety notes in the user manuals.

Necessary operating steps

Check the settings of the instrument receptacles used by pressing theirfocus buttons one by one.

Only if you are using a monopolar instrument.

The long edge of the return electrode (1) must point to the operatingfield.

Following application and during surgery.

If the red return electrode symbol lights up, check the following:

• Is the return electrode correctly connected to the device?

• Does the long edge of the return electrode point to the operatingfield?

• Does the return electrode have sufficient contact to the skin?

!

1 Switch on the device

2 Select and adopt program

3 Check settings

max. Watts

COAG

Effect

+

+CUT

Effect

max. Watts

+

+

Prog/Setup

HIGH CUT FORCEDCOAG

2MONOPOLAR

Effect

max. Watts max. Watts

Effect

4 Apply and connect return electrode

5 Monitor return electrode

Correct Error

6 Connect instruments

ATTENTION: You may only plug monopo-lar 4 mm Ø connectors into the receptacle with the blue ring (1). Otherwise you damage the device.

1

1

Page 2: QUICK GUIDE VIO 300 S - Erbe Med · VIO® 300 S This quick guide is no substitute for briefing and user manual. This quick guide does not include any safety notes. Make yourse lf

© Erbe Elektromedizin GmbH Hotline +49 7071 755 123 www.erbe-med.com

Optional operating steps

With the "More"-button, you can select further modes (if available).

AUTO START can only be allocated to the bipolar receptacle.

With the "More"-button, you can select further foot switch types and(if available) AUTO START.

7 Changing mode

8 Changing effect

9 Changing power limit

Effect

+

Effect

+

max. Watts

+

max. Watts

+

10 Selecting receptacle (e.g. BIPOLAR)

11 Allocating AUTO START or foot switch to the selected receptacle

12 For APC applications, open argon bottle