question bank on lhb coaches - indian railways
TRANSCRIPT
Question Bank on
LHB Coaches
भारत सरकार GOVERNMENT OF INDIA
रेल मंत्रालय MINISTRY OF RAILWAYS
CAMTECH/E/EP-03/2020-21/QB-LHB/1.0
March 2021
END USER: Coaching Maintenance Staff
For Official Use Only
Maharajpura, Gwalior – 474 005
ii
Question Bank on
LHB Coaches
iii
“We at RDSO, Lucknow are committed to maintain
and update transparent standards of services to
develop safe, modern and cost effective railway
technology complying with statutory and regulatory
requirements, through excellence in research,
designs and standards by setting quality objectives,
commitment to satisfy applicable requirements and
continual improvements of the quality management
system to cater to growing needs, demand and
expectations of passenger and freight traffic on the
railways through periodic review of quality
management systems to achieve continual
improvement and customer appreciation. It is
communicated and applied within the organization
and making it available to all the relevant interested
parties.”
QUALITY POLICY
iv
FOREWARD
Indian Railways started inception & mass production of LHB coaches
from the year 2002. Now the number of LHB coaches is increasing
day by day. These coaches have been manufactured with advanced
technology as compared to ICF coaches to provide better comfort,
safety and modern facilities. The design of LHB coaches is different
from the ICF coaches and so as its maintenance practice.
Dissemination of knowledge regard to LHB coaches & Proper
training of Coach Maintenance staff & supervisors is very important.
CAMTECH has prepared this question bank to meet the training
requirement of staff and supervisors. Providing knowledge of LHB
coaches is the main objective of this handbook. This handbook
"Question Bank (Electricals) on LHB Coaches" contains objective-
type questions related to a brief introduction, technical details,
RMPU, WRA, power car related components & maintenance
schedule of LHB coaches.
I am sure that the handbook will be useful for training of maintenance
related staff and supervisors to ensure trouble-free train operation
service.
CAMTECH Gwalior Jitendra Singh
Date: 22.03.2021 Principal Executive Director
v
PREFACE
The maintenance of LHB-type coaches is quite different from that of
ICF design coaches. Therefore, it has become necessary to provide
different training materials for maintenance staff and supervisors. The
artisans and supervisors involved in maintenance & safety operations
are considered up-to-date respecting the technical knowledge of this
coaching stock.
CAMTECH has prepared a hand booklet on "Question Bank
(Electricals) on LHB Coaches" with a view to assisting the employees
through training in which more than 250 questions related to a brief
introduction, technical and features of various components, and
maintenance activities of LHB coaches have been compiled.
The purpose of this handbook is to assist the employees concerned
and does not supersede any existing instructions from Railway Board,
RDSO or IRCA etc. Most of the data and information mentioned
herein are available in LHB manual and in various books or other
printed matters. If any changes are made, these will be issued in the
form of correction slips.
Technological upgrading and learning is a continuous process. Hence
feel free to write us for any additions/modifications or in case you
have any suggestions to improve the handbook. Your contribution in
this direction will be highly appreciated.
CAMTECH, Gwalior Himanshu Maheshwari
Date: 22.03.2021 Dy. Director (Electrical)
vi
CONTENTS
FOREWARD .................................................................................................. iv
PREFACE ........................................................................................................ v
CONTENTS ................................................................................................... vi
ISSUE OF CORRECTION SLIP ........................................................................ vii
DISCLAIMER ................................................................................................viii
OUR OBJECTIVE ..........................................................................................viii
1 GENERAL QUESTIONS ......................................................................... 1
2 MAINTENANCE SCHEDULE ................................................................. 2
3 TECHNICALLY QUESTIONS .................................................................. 4
4 WRA .................................................................................................... 6
5 TECHNICAL DATA RMPU ..................................................................... 9
6 REGULATED CUM EMERGENCY BATTERY CHARGER ........................ 15
7 REGULATED BATTERY CHARGER OF REBC ........................................ 16
8 EMERGENCY BATTERY CHARGER (OF REBC) .................................... 18
9 PROTECTIONS FOR REGULATED BATTERY CHARGER ....................... 19
10 PROTECTIONS FOR EMERGENCY BATTERY CHARGER ...................... 20
11 LIGHT FITTINGS ................................................................................. 21
12 BATTERY ........................................................................................... 23
13 EOG POWER CAR .............................................................................. 27
14 RELAY FOR PROTECTION OF GENERATOR CAR ................................ 32
15 PANTRY CAR AND MINI PANTRY EQUIPMENT ................................. 35
16 LHB NON AC COACH ....................................................................... 39
17 FILL IN THE BLANKS ......................................................................... 47
ANSWERS .................................................................................................... 48
vii
ISSUE OF CORRECTION SLIP
The correction slips to be issued in future for this handbook
will be numbered as follows:
CAMTECH/ E/Ep-03/2020-21/QB-LHB/1.0/C.S. # XX date---
Where “XX” is the serial number of the concerned
correction slip (starting from 01 onwards).
CORRECTION SLIPS ISSUED
Sr. No. Date of Issue Page no. & Item no.
modified
Remarks
viii
DISCLAIMER
It is clarified that the information given in this booklet does not
supersede any existing provisions laid down by the Railway Board,
RDSO and OEM’s Manual. This document is not statuary and
instructions given are for the purpose of guidance only. If at any
point contradiction is observed, then Railway Board/RDSO guidelines
and OEM’s Maintenance and Operating Manuals may be referred.
OUR OBJECTIVE
To upgrade maintenance technologies and methodologies and
achieve improvement in productivity and performance of all
Railway assets and manpower which inter-alia would cover
reliability, availability, utilization and efficiency.
If you have any suggestion & any specific comment, please write to
us:
Contact person: Dy. Director (Electrical)
Postal Address: Centre for Advanced Maintenance
Technology, Opposite Hotel Adityaz,
Near DD Nagar, Maharajpur, Gwalior
(M.P.) Pin Code – 474 005
Phone : 0751 - 2470740
Fax : 0751 – 2470841
E-mail : [email protected]
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 1
Question Bank on LHB Coaches (Electrical) March, 2021
1 GENERAL QUESTIONS
1. What is the full form of LHB?
a. Lower heavy Bogie b. Linke Hofmann-Busch
c. low height Bogie d. None of these
2. What is the riding index of LHB coach?
a. 2.0 b. 2.5
c. 2.75 d. 3.0
3. What is the length of LHB coaches’ body?
a. 23570 mm b. 23545 mm
c. 23540 mm d. 23565 mm
4. What is the maximum width of LHB coaches’ body?
a. 3260 mm b. 3240 mm
c. 3456 mm d. 2356 mm
5. What is the higher speed potential of LHB coaches?
a. 160 up to 180 Kmph b. 180 up to 200 Kmph
c. 160 up to 200 Kmph d. 200 up to 220 Kmph
6. What is the Length of the LHB Power car body?
a. 24000 mm b. 23540 mm
c. 2400 mm d. 24430 mm
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 2
Question Bank on LHB Coaches (Electrical) March, 2021
2 MAINTENANCE SCHEDULE
7. D1 maintenance of LHB coaches done after how long time?
a. 7±1 day b. 15 days
c. Every Trip d. 30 days
8. D2 maintenance of LHB coaches done after how long time?
a. 30 days ± 1days b. 30 days ± 3days
c. 30 days ± 5days d. 30 days ± 7 days
9. D3 maintenance of LHB coaches done after how long time?
a. 90 days ± 7days b. 120 days ± 3days
c. 150 days ± 1days d. 180 days ± 15 days
10. ‘SS-I’ maintenance of LHB coaches done after how long
time?
a. 1 year b. 1.5 year
c. 2 years d. 3 years
11. ‘SS-II’ maintenance of LHB coaches done after how long
time?
a. 1 year b. 1.5 year
c. 2 years d. 3 years
12. ‘SS -III’ maintenance of LHB coaches done after how long
time?
a. 5 years b. 4 years
c. 3 years d. 6 years
13. On KM basis ‘SS- I’ of LHB coach is done -
a. 5 lakhs b. 6 lakhs
c. 9 lakhs d. 12 lakhs
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 3
Question Bank on LHB Coaches (Electrical) March, 2021
14. On KM basis ‘SS -II’ of LHB coach is done -
a. 5 lakhs b. 6 lakhs
c. 12 lakhs d. 24 lakhs
15. ‘POH’ maintenance of LHB coaches done after how long
time?
a. 5 lakhs b. 6 lakhs
c. 12 lakhs d. 24 lakhs
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 4
Question Bank on LHB Coaches (Electrical) March, 2021
3 TECHNICALLY QUESTIONS
16. The Fire Extinguisher used in AC LHB coaches is –
a. Foam type b. DCP Type
c. CO2 type d. None of these
17. Fire Extinguisher should be refilled -
a. Every month b. Every 3 months
c. After 1 year d. On every trip
18. What is the full form of EOG?
a. End on generation b. Mid on generation
c. Hotel load on generation d. Head on generation
19. What is the full form of HOG?
a. End on generation b. Mid on generation
c. Hotel load on generation d. Head on generation
20. What is the hotel load?
a. Light and Fan load b. Air conditioning load
c. Pantry equipment load d. All of above
21. How many volts are supplied to LHB coaches?
a. 230 volts b. 415 volt 3 phase
c. 750 volt 3 phase d. 1500 volt 3 phase
22. How many feeders are supplied Power to LHB coaches?
a. 1 b. 2
c. 3 d. 4
23. What is the Coil Voltage of the Main feeder contactor in the
LHB AC coach?
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 5
Question Bank on LHB Coaches (Electrical) March, 2021
a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC
24. What is the rating of Z-S Coupling?
a. 200 Amp. b. 300 Amp.
c. 400/500 Amp. d. None
25. What is the capacity of the step-down transformer
provided in the coaches?
a. 100 kVA b. 75 kVA
c. 60 kVA
d. 50 kVA
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 6
Question Bank on LHB Coaches (Electrical) March, 2021
4 WRA
26. What is the full form of WRA?
a. Wire relay appliances b. Water raising apparatus
c. Worker relief
arrangement
d. None of these
27. How many water tanks provided under the frame of AC
coach?
a. 4 b. 3
c. 2 d. None
28. What is the Capacity of the Water Tank provided under the
frame of the coach?
a. 500 liter b. 550 liter
c. 600 liter d. 685 liter
29. Where mounted the WRA in the Coach?
a. Bogie b. Under frame
c. A & B d. None
30. Which type of Motor is used in mono-block centrifugal
type WRA?
a. DC b. AC
c. A & B d. None
31. What is the voltage rating of the AC motor used with
WRA?
a. 110V, AC b. 230V, AC
c. 415 V, AC d. None
32. What is the capacity of the motor provided in the WRA?
a. 1 HP b. 0.5 HP
c. 2 HP d. None
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 7
Question Bank on LHB Coaches (Electrical) March, 2021
33. Which type of motor used in WRA?
a. Single phase induction
motor
b. Two phase induction
motor
c. Three phase induction
motor
d. None
34. Which type of motor used in the pump set for WRA?
a. Squirrel cage b. Slip ring
c. A (or) B d. None
35. What is the main purpose of the pump controller?
a. To control WSP b. To control WRA
pump
c. To control contactors d. None of the above
36. What is the class of insulation of winding in the pump motor?
a. H- class b. F-class
c. E-class d. none of the above
37. What is the full load current of motor of pump set of WRA?
a. 1.1 Amp b. 1.5 Amps
c. 2.5 Amps d. 3.0 Amps
38. What is the rated speed of the pump set of WRA?
a. 1520 RPM b. 2800 RPM
c. 3000 RPM d. 3200 RPM
39. What is the total head of the pump set for WRA?
a. 3 mts. b. 5 mts.
c. 8 mts. d. 10 mts.
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 8
Question Bank on LHB Coaches (Electrical) March, 2021
40. What is the discharging capacity of the pump set?
a. 0.5 LPS b. 0.7 LPS
c. 0.8 LPS d. 1.0 LPS
41. What is the suction flange size of the pump set of WRA?
a. 1” BSP b. 2’’ BSP
c. 3” BSP d. 4” BSP
42. What is the protection used in the monoblock pump set of
WRA?
a. Single phasing b. Overvoltage
c. Dry run d. All of above
43. How many pump sets provided in AC coach?
a. One b. Two
c. Three d. Four
44. Each pump in coach is alternately switched by the pump
controller for how many hours?
a. 6 hours b. 4 hours
c. 3 hours d. 2 hours
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 9
Question Bank on LHB Coaches (Electrical) March, 2021
5 TECHNICAL DATA RMPU
45. What is the voltage of contactor coils of the LHB Variant
RMPUs control panel?
a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC
46. How many AC Package Unit (RMPU) provided in the
coaches?
a. 2 b. 3
c. 4
d. 1
47. What are the Main Features of Air Conditioning System?
a. Microprocessor
controlled RMPU
b. Humidity control
c. NTC type
temperature sensor
d. All the above
48. What is the Output Cooling capacity per unit?
a. 5.0 TR b. 6.0 TR
c. 7.0 TR d. 8.0 TR
49. What is the Output Heating capacity per unit?
a. 5.0 kW b. 6.0 kW
c. 7.0 kW d. 8.0 kW
50. What is the capacity of the Compressor motors per unit?
a. 5.0 kW b. 4.9 kW
c. 7.0 kW d. 6.0 kW
51. What is the Nominal power of unit?
a. 15 kVA b. 17.5 kVA
c. 16.5 kVA d. 17 kVA
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 10
Question Bank on LHB Coaches (Electrical) March, 2021
52. What is the capacity of the Condenser Fan motor?
a. 1.5 HP b. 2 HP
c. 1 HP d. 2.5 HP
53. What is the capacity of the evaporator Fan motor radial?
a. 1.5 HP b. 2HP
c. 1 HP d. 2.5 HP
54. What is the volume of the Fresh air supply (m3/hr)?
a. 720 b. 820
c. 700 d. 800
55. What is the Maximum power input, cooling (kW)?
a. 12.25 b. 12.50
c. 13.25 d. 13.50
56. What is the Maximum power input, dehumidifying (kW)?
a. 10.0 Approximate b. 11.0 Approximate
c. 09.0 Approximate
d. 12.0 Approximate
57. Which Refrigerant is used?
a. R 11 b. R 12
c. R 22, R407 C d. R 32
58. What is the Weight (kg) of unit?
a. 600 Approximate b. 610 Approximate
c. 620 Approximate d. 630 Approximate
59. What are the Dimensions (mm) of unit?
a. 2200 x 2000 x 500 b. 2200 x 2200 x 500
c. 2000 x 2200 x 500 d. 2000 x 2000 x 500
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 11
Question Bank on LHB Coaches (Electrical) March, 2021
60. How much quantity of refrigerant is used in RMPU Make
Fedders Lloyd/LELL?
a. 3.2 kg per unit b. 4.2 kg per unit
c. 5.0 kg per unit d. 5.2 kg per unit
61. How much quantity of refrigerant is used in RMPU Make
Amit?
a. 2.0 kg per unit b. 2.2 kg per unit
c. 3.2 kg per unit d. 4.2 kg per unit
62. How much quantity of refrigerant is used in RMPU Make
SIDWAL/INTEC?
a. 1.85 kg per unit b. 2.00 kg per unit
c. 3.85 kg per unit d. 2.85 kg per unit
63. Each air conditioning package unit has how many cooling
circuits?
a. 1 b. 2
c. 3 d. 4
64. Each RMPU has how many compressors?
a. 4 b. 3
c. 2 d. 1
65. Each RMPU has how many condenser fans?
a. 3 b. 1
c. 4 d. 2
66. Each RMPU has how many Heating assemblies?
a. 1 b. 2
c. 3 d. 4
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 12
Question Bank on LHB Coaches (Electrical) March, 2021
67. How many Maintenance covers are provided in the Each
RMPU?
a. 4 b. 6
c. 8 d. 10
68. How many Air inlets are provided for circulating air in each
RMPU?
a. 4 b. 3
c. 2 d. 1
69. How many Air inlets are provided for fresh air in each
RMPU?
a. 3 b. 1
c. 4 d. 2
70. How many Air outlet are provided for supply air in each
RMPU?
a. 1 b. 2
c. 3 d. 4
71. Each RMPU has how many mixed air filters?
a. 1 each b. 2 each
c. 3 each d. 4 each
72. Each RMPU has how many Fresh air filters?
a. 1 each b. 2 each
c. 3 each d. 4 each
73. How many Sealed Compressors are provided in the coach?
a. 1 b. 2
c. 3 d. 4
74. How many Condenser Motors are provided in the coach?
a. 4 b. 3
c. 2 d. 1
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 13
Question Bank on LHB Coaches (Electrical) March, 2021
75. How many Heater units are provided in the coach?
a. 1 b. 2
c. 3 d. 4
76. How many Condenser Coil are provided in the coach?
a. 1 each b. 2 each
c. 3 each d. 4 each
77. How many Cooling Coil are provided in the coach?
a. 1 each b. 2 each
c. 3 each d. 4 each
78. What is the Amperes setting of Overload relay for the
Compressor Motor?
a. 09 Amperes b. 10 Amperes
c. 11 Amperes d. 12 Amperes
79. What is the Operation Time of the Compressor Motor
Overload Relay?
a. 24 Second b. 30 Second
c. 35 Second d. 40 Second
80. What is the Amperes setting of the Condenser Motor
Overload Relay?
a. 2.0 Amperes b. 2.4 Amperes
c. 3.0 Amperes d. 3.4 Amperes
81. What is the Operation Time of the Condenser Motor
Overload Relay?
a. 24 Second b. 30 Second
c. 34 Second d. 40 Second
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 14
Question Bank on LHB Coaches (Electrical) March, 2021
82. What is the Amperes setting of the Blower Motor Overload
relay?
a. 1.0 Amperes b. 1.5 Amperes
c. 2.0 Amperes d. 2.4 Amperes
83. What is the Operation Time of the Blower Motor Overload
Relay?
a. 24 Second b. 30 Second
c. 34 Second d. 40 Second
84. What is the setting of the LP Cut Out?
a. 09 PSI b. 10 PSI
c. 11 PSI d. 12 PSI
85. What is the Operation Time of the LP Cut Out?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second
86. What is the setting of the HP Cut Out?
a. 200 PSI b. 225 PSI
c. 250 PSI d. 275 PSI
87. What is the Operation Time of the HP Cut Out?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 15
Question Bank on LHB Coaches (Electrical) March, 2021
6 REGULATED CUM EMERGENCY BATTERY CHARGER
88. What is the full form of RBC?
a. Regulated Battery
Charger
b. Rectifier battery
charger
c. Re generative battery
charger
d. None
89. What is the full form of EBC?
a. Emergency Battery
Charger
b. Electronic battery
charger
c. Efficient battery charger d. None
90. What is the full form of REBC?
a. Regulated Cum
Emergency Battery
Charger
b. Rectifier battery
charger
c. Re generative battery
charger
d. None
91. What is the Voltage rating & type of Battery used in LHB
AC coaches?
a. 1100 Ah’ VRLA b. 320 Ah’ VRLA
c. 120 Ah’ VRLA d. 70 Ah’ VRLA
92. What is the Voltage rating of each cell module in LHB AC
coaches?
a. 6 volts b. 12 volts
c. 18 volts d. 24 volts
93. What is the rating of the Regulated Battery Charger (of
RBC)?
a. 4.0 kW b. 4.5 kW
c. 5.0 kW d. 6.5 kW
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 16
Question Bank on LHB Coaches (Electrical) March, 2021
7 REGULATED BATTERY CHARGER OF REBC
94. What is the capacity/output power of the Regulated Battery
Charger (of REBC)?
a. 4.0 kW b. 4.5 kW
c. 5.0 kW d. 6.5 kW
95. What is the Input Voltage of Regulated Battery Charger (of
REBC)?
a. 110 Volt AC b. 110 Volt DC
c. 220 Volt AC d. 415 Volt AC
96. What is the output Voltage of Regulated Battery Charger (of
REBC)?
a. 110 to 135 Volts DC b. 110 to 135 Volts AC
c. 220 to 235 Volts DC d. 220 to 235 Volts AC
97. What is the output Voltage of Regulated Battery Charger (of
REBC) during normal operation of battery charging?
a. 122 volts ±10% b. 122 volts ±2%
c. 110 volts ±20% d. 120 volts ±20%
98. What is the Output current of Regulated Battery Charger (of
REBC)?
a. 15 A b. 20 A
c. 25 A d. 35 A
99. What is the voltage ripple of a Regulated Battery Charger
(of REBC)?
a. ≤ 1 % of the set voltage b. ≤ 2 % of the set voltage
c. ≤ 3 % of the set voltage d. ≤ 4 % of the set voltage
100. What is the Current ripple of RBC (OF REBC)?
a. ≤ 1 % of the set Current b. ≤ 2 % of the set Current
c. ≤ 3 % of the set Current d. ≤ 4 % of the set Current
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 17
Question Bank on LHB Coaches (Electrical) March, 2021
101. What is the Dimension of the charger unit as per RDSO
Specification?
a. 900x400x600 mm b. 950x440x650 mm
c. 920x450x650 mm d. 900x440x650 mm
102. What is the Weight of the charger unit as per RDSO
Specification?
a. <100 kg. b. <110 kg.
c. <120 kg. d. <130 kg
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 18
Question Bank on LHB Coaches (Electrical) March, 2021
8 EMERGENCY BATTERY CHARGER (OF REBC)
103. What is the capacity/output power of the Emergency Battery
Charger (of REBC)?
a. 1.0 kW b. 1.5 kW
c. 2.0 kW d. 2.5 kW
104. What is the Input Voltage of Emergency Battery Charger (of
REBC)?
a. 240 V ± 15% AC b. 415 V ± 15% AC
c. 110 V ± 15% DC d. 240 V ± 15% DC
105. What is the Output current of Emergency Battery Charger
(of REBC)?
a. 15 A b. 20 A
c. 22 A d. 30 A
106. What is the Efficiency of Emergency Battery Charger (of
REBC)?
a. ≥ 80% @ Full Load b. ≥ 85% @ Full Load
c. ≥ 90% @ Full Load d. ≥ 95% @ Full Load
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 19
Question Bank on LHB Coaches (Electrical) March, 2021
9 PROTECTIONS FOR REGULATED BATTERY CHARGER
107. What is the voltage setting for the input AC under-voltage
protection?
a. 280 ± 5V AC b. 300 ± 5V
c. 320 ± 5V d. 380 ± 5V
108. What is the voltage setting for the input AC over-voltage
protection?
a. 430 ± 5V b. 450 ± 5V
c. 480 ± 5V d. 460 ± 5V
109. What is the voltage setting for the output over-voltage
protection?
a. 120 ± 2 V DC b. 130 ± 2 V DC
c. 136 ± 2 V DC d. 140 ± 2 V DC
110. What is the Ampere setting for the Overload protection?
a. 15+20% Amp. b. 20+20% Amp.
c. 35+10% Amp. d. 35+20% Amp.
111. How many amperes three pole MCBs are installed for AC
input protection?
a. 10 Amp. b. 15 Amp.
c. 20 Amp. d. 25 Amp.
112. Which fuses are installed for output protection?
a. 20 Amp. HRC fuse b. 25 Amp. HRC fuse
c. 30 Amp. HRC fuse d. 40 Amp. HRC fuse
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 20
Question Bank on LHB Coaches (Electrical) March, 2021
10 PROTECTIONS FOR EMERGENCY BATTERY CHARGER
113. How many volts set for the Input supply overvoltage?
a. 240 +05%V b. 240 +10%V
c. 240 +15%V d. 240 +20%V
114. How many volts set for the Input supply under-voltage?
a. 240- 05%V b. 240 - 10%V
c. 240 - 15%V d. 240 - 20%V
115. How many ampere single pole MCBs are installed for AC
input protection?
a. 10 Amp. b. 15 Amp.
c. 20 Amp. d. 25 Amp.
116. What is the current limit for Output?
a. 10 Amps. b. 15 Amps.
c. 20 Amps. d. 24 Amps.
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 21
Question Bank on LHB Coaches (Electrical) March, 2021
11 LIGHT FITTINGS
117. What is the rating of the control Transformer used for the
Mobile/laptop charger circuit?
a. 1 kVA b. 2.5 kVA
c. 3 kVA d. 5 kVA
118. What is the input voltage of the control Transformer used
for the Mobile/laptop charger circuit?
a. 110 V AC b. 230 V AC
c. 415 V AC d. 750 V AC
119. What is the Lighting circuit operating Voltage?
a. 12 V DC b. 24 V DC
c. 110 V DC d. 110 V AC
120. What is the type of Toilet exhaust fans used in the LHB AC
coach?
a. Single inlet
centrifugal type
b. Double inlet
centrifugal type
c. Radial type d. None
121. What is the minimum insulation resistance of 750 Volts
wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms
122. What is the minimum insulation resistance of 415 Volts
wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 22
Question Bank on LHB Coaches (Electrical) March, 2021
123. What is the minimum insulation resistance of 110 Volts
wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms
124. What is the rating of DC main fuses in LHB Coach?
a. 16 Amps b. 25 Amps
c. 40 Amps d. 60 Amps
125. What is the setting of the feeder earth leakage relay?
a. 1 Amps b. 2 Amps
c. 3 Amps d. 5 Amps
126. What is the setting of the feeder overload load relay?
a. 200 Amps b. 250 Amps
c. 300 Amps d. 400 Amps
127. What is the rating of Transformer provided for Feeder
contactor control?
a. 100 VA b. 150 VA
c. 200 VA d. 250 VA
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 23
Question Bank on LHB Coaches (Electrical) March, 2021
12 BATTERY
128. What is the rating of the battery provided in the LHB Non-
AC coach?
a. 70 AH b. 100 AH
c. 110 AH d. 120 AH
129. How many 70 Ah VRLA battery modules are used in the
LHB coach?
a. 56 cells b. 18 mono block
c. 9 modules of 12V
each
d. 19 modules of 6V
each
130. What is the rating of Battery fuse in LHB Non-AC coaches?
a. 16 A b. 32 A
c. 35 A d. 40 A
131. What is the type of tray provided inside the battery box for
the placing of batteries?
a. FRP tray b. Steel tray
c. Plastic tray d. On battery box directly
132. What is the means of the FRP?
a. Fire Retardant
Plastic
b. Fibre Reinforced Plastic
c. Fire Reduced Plastic d. Fire Retardant Pipe
133. What is the kind of paint used to paint the battery box?
a. Ordinary Enamel b. Distemper paint
c. Anti-corrosive Fire
retardant
d. None of the above
134. Which type of material is used to make a battery container?
a. Hard rubber or PPCP b. PVC
c. Steel d. FRP
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 24
Question Bank on LHB Coaches (Electrical) March, 2021
135. What is Liberation of gases at anode and cathode of a Lead
Acid cell called?
a. Recombination b. Gassing
c. Stratification d. None of the above
136. What is method adopted to keep the cells Voltage in
uniform condition?
a. Boost charging b. Normal charging
c. Equalizing charging d. Trickle charging
137. What are the means of Boost charging and with what
capacity charging is done?
a. 1/2th of rated current
for 5 Hours
b. Higher rate for short
period @ 2.25 V/cell
c. Rated current for 1 hour d. None of the above
138. What is the charging current for boost charging?
a. 1.5 X normal charge
rate
b. 2 times the normal
current
c. 2.5 times the normal
current
d. 3 times the normal
current
139. What is the voltage per cell maintained for float charging?
a. 1.8 V/cell at constant
potential mode
b. 2.0V/cell at constant
potential mode
c. 2.2V/cell at constant
potential mode
d. 2.4V/cell at constant
potential mode
140. What is the capacity of the battery is expressed in?
a. Ampere hours b. Watts
c. Watt -Hours d. Horse Power
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 25
Question Bank on LHB Coaches (Electrical) March, 2021
141. What are the modes of charging a Lead Acid Battery?
a. Constant potential
mode
b. Constant current mode
c. Both A&B d. None of the above
142. What is the full form of VRLA?
a. Valve Regulated
Lead Acid Cell
b. Valve released lead Acid
Cell
c. Valve Regulated
Low Acid Cell
d. None of the above
143. What is the working principle of the VRLA battery?
a. Pressure release b. Hydrogen recombination
c. Oxygen
recombination
d. None of the above
144. What else is a VRLA battery called?
a. Maintenance-free
batteries
b. Sealed maintenance-free
(SMF) Cell
c. Sealed Cell d. None of the above
145. To increase the voltage of the battery, cells are connected in
a. Series b. Parallel
c. Series/Parallel d. None of the above
146. What is the main purpose for providing the battery bank?
a. Alternator
Voltage is
fluctuating
b. Supply to the coach in
case of feeder supply
failure.
c. Battery Voltage is
constant
d. None of the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 26
Question Bank on LHB Coaches (Electrical) March, 2021
147. What is the applied with cell connecter to prevent
sulphation?
a. Paint b. Kerosene
c. Grease d. Petroleum jelly
148. What is the method of charging recommended for VRLA
batteries?
a. Constant current b. Constant voltage
c. Constant Voltage
Constant Current
d. None of the above
149. What is the open-circuit voltage of the battery bank used for
AC Coaches with VRLA battery?
a. 100 V b. 105 V
c. 115V d. 130 V
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 27
Question Bank on LHB Coaches (Electrical) March, 2021
13 EOG POWER CAR
150. What is the Speed potential of a power car coach?
a. 140 kmph. b. 160 kmph.
c. 180 kmph. d. 200 kmph.
151. What is the capacity of roof mounted AC unit in a power
car?
a. 1x6 Ton b. 2x6 Ton
c. 1x7 Ton d. 2x7 Ton
152. How many Power Transformers provided in the power car?
a. 1 b. 2
c. 3 d. 4
153. What is the capacity of Transformers provided in the power
car?
a. 60 kVA, Star- Delta b. 60 kVA, Star -Star
c. 60 kVA, Delta -
Delta
d. 60 kVA, Delta- Star
154. What is the input Voltage of Transformers?
a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None
155. What is the output Voltage of Transformers?
a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 28
Question Bank on LHB Coaches (Electrical) March, 2021
156. How many DG set provided in the power car?
a. 1 b. 2
c. 3 d. 4
157. What is the capacity of the DG Set Engine?
a. 450 BHP b. 470 BHP
c. 496 BHP d. 500 BHP
158. What is the capacity of the DG Set Alternator?
a. 300 kVA at NTP b. 400 kVA at NTP
c. 500 kVA at NTP d. 600 kVA at NTP
159. What is the output Voltage of the Alternator?
a. 190 Volts, Single
Phase, 2 wires
b. 230 Volts, Single
Phase, 2 wires
c. 415 Volts, 3 Phase, 4
wires
d. 750 Volts, 3 Phase, 4
wires
160. What is the Rating of the Air-Circuit breaker used for
Alternator output?
a. 410 amps b. 520 amps
c. 610 amps d. 800 amps
161. What is the Rating of feeder contactor used in LHB Power
car?
a. 400 amps b. 520 amps
c. 630 amps d. 800 amps
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 29
Question Bank on LHB Coaches (Electrical) March, 2021
162. In LHB Power Car NWP contactor means?
a. Non-Working Power
Car contactor
b. New working power
contactor
c. Network power
contactor
d. None
163. What is AVR means in LHB Power Car?
a. Automatic variable
regulator
b. Automatic voltage
regulator
c. Anti vibration
regulator
d. None
164. How many Diesel tanks provided in the LHB Power Car?
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.
165. What is the total capacity of the Diesel tank provided in the
LHB Power Car?
a. 1500 liters b. 2000 liters
c. 2500 liters d. 3000 liters
166. What is the capacity of each Diesel tank in the LHB Power
Car?
a. 1500 liters b. 2000 liters
c. 2500 liters d. 3000 liters
167. How much Water storage tank provided?
a. 1 x 685 litres b. 2 x 685 litres
c. 1 x 650 litres d. 1 x 665 litres
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 30
Question Bank on LHB Coaches (Electrical) March, 2021
168. What is the capacity of the DG Set Radiator fan?
a. 30 HP b. 40 HP
c. 50 HP d. 60 HP
169. What is the input Voltage for the DG Set Radiator fan
motor?
a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None
170. What should be used in radiators for cooling of the D G set?
a. Ordinary Water b. Distilled Water
c. Coolants d. None
171. How many Ventilation fans provided in the power car?
a. 1 b. 2
c. 3 d. 4
172. How many Ventilation Motors provided in the power car?
a. 1 No. b. 2 Nos.
c. 3 Nos. d. 4 Nos.
173. What is the capacity of the Ventilation fans motor?
a. 6.0 HP b. 6.5 HP
c. 7.0 HP d. 7.5 HP
174. What is the capacity of the Starter battery?
a. 120 Ah b. 290 Ah
c. 320 Ah d. 1100 Ah
175. What is the input voltage of the Starter battery Charger?
a. 110 V, DC b. 230 V, AC
c. 415 V, AC d. None
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 31
Question Bank on LHB Coaches (Electrical) March, 2021
176. Which type of temperature controller is installed?
a. Fine control in 3
steps
b. Fine control in 4
steps
c. Fine control in 5
steps
d. Fine control in 6
steps
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 32
Question Bank on LHB Coaches (Electrical) March, 2021
14 RELAY FOR PROTECTION OF GENERATOR CAR
177. What is the setting of the over-speed relay switch?
a. 1400 ± 4.5 % RPM b. 1600 ± 4.5 % RPM
c. 1800 ± 4.5 % RPM d. 2000 ± 4.5 % RPM
178. What are the permissible limits of LOP (Low Oil Pressure)
for Cummins engine?
a. 2.166.33 kg/sqcm. b. 3.16, 6.33 kg/sqcm.
c. 3.16,6.50 kg/sqcm. d. 4.16, 6.33 kg/sqcm.
179. How many Amperes are set for the alternator earth leakage
relay?
a. 2.0 Amperes b. 2.5 Amperes
c. 3.0 Amperes d. 3.5 Amperes
180. What is the Operation Time of the Alternator Earth Leakage
Relay?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second
181. How many Amperes are set for the Feeder earth leakage
relay?
a. 2.0 Amperes b. 2.5 Amperes
c. 3.0 Amperes d. 3.5 Amperes
182. What is the Operation Time of the Feeder Earth Leakage
Relay?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second
183. How many Volts are set for the Under-Voltage relay?
a. 300 Volts b. 350 Volts
c. 375 Volts d. 400 Volts
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 33
Question Bank on LHB Coaches (Electrical) March, 2021
184. What is the Operation Time of the Under-Voltage Relay?
a. 6.0 Second b. 7.0 Second
c. 8.0 Second d. 9.0 Second
185. How many Amperes are set for the Feeder Overload Relay?
a. 200 Amperes b. 300 Amperes
c. 350 Amperes d. 400 Amperes
186. What is the Operation Time of the Feeder Overload Relay?
a. 20 Second b. 25 Second
c. 30 Second d. 35 Second
187. How many Amperes are set for the Air Circuit Breaker?
a. 300 Amperes b. 360 Amperes
c. 350 Amperes d. 400 Amperes
188. What is the Operation Time of the Air Circuit Breaker?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second
189. How many RPM is set for the Over Speed Relay?
a. 1600 RPM b. 1700 RPM
c. 1800 RPM d. 1900 RPM
190. What is the Operation Time of the Over Speed Relay?
a. < 1Second b. > 1Second
c. < 2 Second d. > 2 Second
191. How much is set for the High-Water Temperature INTAC
Engine?
a. 100 ºC b. 107 ºC
c. 110 ºC d. 115 ºC
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 34
Question Bank on LHB Coaches (Electrical) March, 2021
192. How much is set for the High-Water Temperature
CUMMINS Engine?
a. 90 ºC b. 95 ºC
c. 97 ºC d. 100 ºC
193. Which type of Fire extinguishers is used in the power car?
a. Soda Acid type b. Water Foam based type.
c. Dry Powder Type d. C.T.C & CO2 type
194. Which capacity fuses are used for the protection of the
incoming side of 750 volts in LHB?
a. 3 x 60 A HRC
fuses
b. 3 x 63 A HRC fuses
c. 3 x 65 A HRC
fuses
d. Incoming feeder directly
on the contactors
195. Which capacity fuses are used for the protection of the
incoming side of 415 volts?
a. 3 x 60 A HRC
fuses
b. 3 x 70 A HRC fuses
c. 3 x 80 A HRC
fuses
d. 3 x 100 A HRC
fuses
196. What is the Coach length of the LHB power car?
a. 23.3 meters b. 23.5 meters
c. 23.8 meters d. 24.0 meters
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 35
Question Bank on LHB Coaches (Electrical) March, 2021
15 PANTRY CAR AND MINI PANTRY EQUIPMENT
197. What are the Dimensions of Hot case provided in mini pantry
of coaches?
a. 900 x 1050 x 600 mm b. 900 x 1050 x 605 mm
c. 910 x 1092 x 600 mm d. 950 x 1092 x 600 mm
198. What is the operating volt of hot case provided in mini pantry
of coaches?
a. 110 Volt b. 230 Volt
c. 415 Volt d. 110 Volt DC
199. What is the capacity of the Heating element of hot case
provided in the mini pantry of coaches?
a. 3 x 500 Watt or 2 x 500 watt b. 750 Watt
c. 1800 Watt d. 2000 Watt
200. What is the Operating temperature of hot case provided in the
mini pantry of coaches?
a. 60 ºC b. 70 ºC
c. 80 ºC d. 90 ºC
201. What is the range of the Thermostat of Hot case provided in
the mini pantry of coaches?
a. 30 – 80° C b. 40 – 80° C
c. 50 – 80° C d. 60 – 80° C
202. What are the Dimensions of Refrigerating Unit provided in
mini pantry of coaches?
a. 1100 x 595 x 1195 mm b. 1157 x 550 x 1195 mm
c. 1157 x 595 x 1195 mm d. 1157 x 595 x 1150 mm
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 36
Question Bank on LHB Coaches (Electrical) March, 2021
203. What is the power of the Refrigerating Unit provided in the
mini pantry of coaches?
a. 500 Watt b. 600 Watt
c. 700 Watt d. 800 Watt
204. What is the Refrigeration capacity of the Refrigerating Unit
provided in the mini pantry of coaches?
a. 550 kCal/Hr. b. 560 kCal/Hr.
c. 570 kCal/Hr. d. 580 kCal/Hr.
205. Which Refrigerant is used in the Refrigerating Unit provided
in the mini pantry of coaches?
a. R11 b. R12
c. R22 d. R32
206. What is the Thermostat range of the Deep freezer provided in
the mini pantry of coaches?
a. -18 to -25°C b. -20 to -25°C
c. -20 to -30°C d. -22 to -25°C
207. What is the Thermostat range of the Bottle cooler provided in
the mini pantry of coaches?
a. 2 to + 10°C b. 3 to + 5°C
c. 0 to + 05°C d. 3 to + 15°C
208. What is the capacity of the Bottle cooler provided in the mini
pantry of coaches?
a. 70 Bottle of 1.0 liter b. 80 Bottle of 1.0 liter
c. 90 Bottle of 1.0 liter d. 100 Bottle of 1.0 liter
209. What is the Thermostat range of the Cooling compartment of
the Refrigerating Unit provided in the mini pantry of
coaches?
a. 0 to + 03°C b. 0 to + 05°C
c. 0 to + 10°C d. 0 to + 15°C
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 37
Question Bank on LHB Coaches (Electrical) March, 2021
210. What are the Dimensions of the Bottle Cooler provided in the
mini pantry of coaches?
a. 900x600x900 b. 910x620x900 mm
c. 910x600x940 mm d. 910x600x900 mm
211. What is the Power consumption of the Bottle Cooler provided
in the mini pantry of coaches?
a. 200 watt b. 400 watt
c. 450 watt d. 500 watt
212. What is the Capacity of the Soup Warmer for Food insert
provided in the mini pantry of coaches?
a. 10 litres b. 12 litres
c. 13 litters d. 14 litres
213. What is the Capacity of the Soup Warmer for heating medium
provided in the mini pantry of coaches?
a. 0.4 litres of water b. 0.5 litres of water
c. 0.6 litres of water d. 0.7 litres of water
214. What is the maximum power of the Soup Warmer provided in
the mini pantry of coaches?
a. 450 watts b. 475 watts
c. 500 watts d. 550 watts
215. What is the nominal current of the Soup Warmer provided in
the mini pantry of coaches?
a. 1.5 Amp. b. 2.0 Amp.
c. 2.2 Amp. d. 2.5 Amp.
216. What is the Weight of the Soup Warmer provided in the mini
pantry of coaches?
a. 4.0 kg b. 4.5 kg
c. 5.0 kg d. 5.5 kg
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 38
Question Bank on LHB Coaches (Electrical) March, 2021
217. What is the Thermostat Lower temperature range of the Soup
Warmer provided in the mini pantry of coaches?
a. 60-62° C b. 62-65° C
c. 70-72° C d. 72-75° C
218. What is the Thermostat High-temperature range of the Soup
Warmer provided in the mini pantry of coaches?
a. 80-82° C b. 82-85° C
c. 85-87° C d. 90-92° C
219. The cooking table is divided into how many parts.
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.
220. How many Insect killers provided in the pantry car?
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.
221. How many Oven Toaster Griller provided in the pantry car?
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.
222. What is the Capacity of hot water boiler provided in Mini-
pantry of LHB AC coach?
a. 12 litres b. 15 litres
c. 20 litres d. 25 litres
223. What is the rating of hot water boiler provided in LHB AC
coach?
a. 2 KW b. 3 KW
c. 5 KW d. None
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 39
Question Bank on LHB Coaches (Electrical) March, 2021
16 LHB NON AC COACH
224. How much input Voltage of feeder contactor coil is in the
LHB Non-AC coaches?
a. 110 V AC b. 110 V DC
c. 415 V AC d. None of the above
225. What is the rating of feeder contactor coil circuit
Transformer in LHB Non-AC coaches?
a. 100 VA b. 110 VA
c. 150 VA d. None of the above
226. What is the rating of the main power transformer in LHB
Non-AC chair car coaches?
a. 09 KVA b. 10 KVA
c. 12 KVA d. 15 KVA
227. The no. of panels available in LHB Non-AC coach are
a. 2 b. 3
c. 4 d. None of the above
228. What is the rating of the main power transformer in LHB
Non-AC coaches?
a. 09 KVA b. 10 KVA
c. 12 KVA d. None of the above
229. How many fuses available in a Power transformer?
a. 3 Nos. b. 5 Nos.
c. 7 Nos. d. 9 Nos.
230. What is the input voltage of the power transformer?
a. 230 V b. 415 V
c. 750 V d. None of the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 40
Question Bank on LHB Coaches (Electrical) March, 2021
231. What is the output voltage of the power transformer?
a. 190/110 V b. 415 V
c. Both A & B d. None of the above
232. Power transformer is connected in
a. star-delta b. delta-delta
c. star-star d. delta- star
233. What is the class of insulation of winding in the
transformer?
a. H- class b. F-class
c. E-class d. none of the above
234. The transformer fitted in the under slung with How much
anti-vibration?
a. 2 b. 4
c. 6 d. none of the above
235. How much secondary winding available in the power
transformer?
a. 1 b. 2
c. 3 d. 4
236. What is the rating of fuse provided for the main HT 750
Volts of Transformer input circuit in LHB Non-AC coach?
a. 16 Amp b. 25 Amp
c. 30 Amp d. 40 Amp
237. What is the purpose of RCBO provided in LHB non-ac
coaches?
a. Protection against
electric shock
b. Protection for
equipment
c. both a & b d. None of the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 41
Question Bank on LHB Coaches (Electrical) March, 2021
238. What is the operating Voltage of Lights & fans in the LHB
Non-AC coach?
a. 415 V AC b. 230 V AC
c. 110 V AC d. 110 V DC
239. What are the meaning of an HV?
a. High voltage b. Heavy voltage
c. Both A & B d. None of the above
240. Where HV panel is mounted in the coach?
a. Near the LV Panel b. Roof
c. Under frame d. None of the above
241. What are the meaning of an LV?
a. Lower voltage b. Low voltage
c. Both A & B d. None of the above
242. Where LV panel is mounted in the coach?
a. Near the HV Panel b. Onboard
c. Under frame d. None of the above
243. What is the size of the fuse provided for the main circuit of
lights and fans?
a. 06 Amps b. 10 Amps
c. 16 Amps d. 20 Amps
244. Which type of light used for night lights in LHB Non-AC
coach?
a. IC lamps b. CFL
c. FL d. LED
245. How much total connected load in 3 Tier Sleeper LHB Non-
AC coaches?
a. 1104 W b. 1906 W
c. 2206 W d. 3000 W
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 42
Question Bank on LHB Coaches (Electrical) March, 2021
246. How much total connected load in GS (LS) LHB Non-AC
coaches?
a. 1906 W b. 2124 W
c. 2206 W d. 3000 W
247. How much total connected load in Chair Car LHB Non-AC
coaches?
a. 1906 W b. 2124 W
c. 2193 W d. 3000 W
248. How many fans available in LHB Non-AC coaches?
a. 27 b. 30
c. 33 d. 36
249. What is the rating of BLDC, carriage fans used in LHB
Non-AC coaches?
a. 27 W b. 30 W
c. 38 W d. 40 W
250. What is the size of the fan used in LHB Non-AC coaches?
a. 100 mm sweep b. 200 mm sweep
c. 300 mm sweep d. 400 mm sweep
251. What is the suitable range of working voltage of the BLDC
fan?
a. 80 -110 V DC b. 80 -120 V DC
c. 90 -140 V DC d. 90 -140 V AC
252. How many mm wide color bands are there on the
circumference of the fan body in a BLDC fan?
a. 10 mm b. 20 mm
c. 30 mm d. 40 mm
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 43
Question Bank on LHB Coaches (Electrical) March, 2021
253. Which color of the two bands is in BLDC fan?
a. Green & Yellow b. Green & Red
c. Red & Yellow d. Blue & Yellow
254. How many Emergency lights (AEL) are provided in LHB
Non-AC coach?
a. 2 b. 4
c. 6 d. 8
255. What is the charging Voltage of the Accident Emergency
light?
a. 415 V AC b. 230 V AC
c. 110 VAC d. 110 VDC
256. What is the type of cables used in LHB Non-AC coaches?
a. Elastomeric cable b. PILC
c. XLPE d. PVC
257. Which color is adopted for the wiring of light positive cable
in LHB Non-AC coaches?
a. RED b. YELLOW
c. BLUE d. BLACK
258. Which color is adopted for the wiring of fan negative cable
in LHB Non-AC coaches?
a. RED b. YELLOW
c. BLUE d. BLACK
259. Which color is adopted for the wiring of fan positive cable
in LHB Non-AC coaches?
a. RED b. BLUE
c. BLACK d. YELLOW
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 44
Question Bank on LHB Coaches (Electrical) March, 2021
260. Which color is adopted for the wiring of all negative except
fan negative cable in LHB Non-AC coaches?
a. RED b. YELLOW
c. BLUE d. BLACK
261. Which is the main feeder contactor for feeder 1?
a. K 01 b. K 02
c. Both A & B d. None of the above
262. Which is the main feeder contactor for feeder 2?
a. K 01 b. K 02
c. Both A & B d. None of the above
263. What is the purpose of the push-button provided in the LV
panel?
a. To check Rotary
switch
b. To check Mobile charger
c. To check Emergency
light
d. None of the above
264. How many types of voltages are used in an under-slung HV
panel?
a. 750 V b. 415 V
c. 190/110 V d. All the above
265. How many types of voltages are used in an onboard LV
panel?
a. 190 V AC b. 110 V AC
c. 110 V DC d. All the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 45
Question Bank on LHB Coaches (Electrical) March, 2021
266. What is the size of cable used for R, Y, B phases in the
feeder junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm
267. What is the size of cable used for Neutral in a feeder
junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm
268. What is the size of cable used for Earth in the feeder
junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm
269. What is the size of the cable used for the control cable?
a. 1.5 sq. mm b. 2.5 sq. mm
c. 10 sq. mm d. 25 sq. Mm
270. What is the size of cable used from Feeder to HV panel?
a. 10 sq. mm b. 16 sq. mm
c. 25 sq. mm d. 35 sq. Mm
271. What is the size of cable used from HV panel to Power
Transformer?
a. 10 sq. mm b. 25 sq. mm
c. 35 sq. mm d. 70 sq. Mm
272. What is the Disconnecting and earthing device?
a. OFF load switch b. ON load switch
c. Both A & B d. None of the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 46
Question Bank on LHB Coaches (Electrical) March, 2021
273. Which equipment is used to prevent return current flow
through-axle bearing?
a. D & ED b. Transformer
c. Wheel set earthing
equipment
d. None of the above
274. What is the rating of the glass fuse used in the mobile
charging socket?
a. 200 mA b. 500 mA
c. 600 mA d. None of the above
275. What is the operating voltage of Pantry equipment in an
LHB Non-AC chair car?
a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC
276. What is the meaning of WSP?
a. Pump b. Pantry
c. AC Plant d. Anti Skid Device
277. What is the meaning of AVM?
a. Anti vibration
mounting
b. Auto vibration
mounting
c. Automatic voltages
monitor
d. None of the above
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 47
Question Bank on LHB Coaches (Electrical) March, 2021
17 FILL IN THE BLANKS
What are the codes of various LHB coaches in Indian Railways?
Fill in the blanks.
a. Code of First AC EOG LHB Coaches is the...........................
b. Code of AC 2 Tier SG LHB Coaches is the............................
c. Code of AC 2 Tier EOG LHB Coaches is the.........................
d. Code of AC 3 Tier SG LHB Coaches is the............................
e. Code of AC 3 Tier EOG LHB Coaches is the.........................
f. Code of Executive AC chair car of is the …….......................
g. Code of AC chair car EOG LHB Coaches is the....................
h. Code of AC Pantry Car EOG LHB Coaches is the................
i. Code of Generator Car LHB Coaches is the..........................
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 48
Question Bank on LHB Coaches (Electrical) March, 2021
ANSWERS
1. GENERAL QUESTIONS
1. - (b) 2. - (c) 3. - (c) 4. - (b) 5. - (c)
06. - (d)
2. MAINTENANCE SCHEDULE
07. - (c) 08. - (b) 09. - (d) 10. - (b) 11. - (d)
12. - (d) 13. - (b) 14. - (c) 15. - (d)
3. TECHNICALLY QUESTIONS
16. - (b) 17. - (c) 18. - (a) 19. - (d) 20. - (d)
21. - (c) 22. - (b) 23. - (a) 24. - (c) 25. - (c)
4. WRA
26. - (b) 27. - (b) 28. - (d) 29. - (b) 30. - (b)
31. - (c) 32. - (b) 33. - (c) 34. - (a) 35. - (b)
36. - (b) 37. - (a) 38. - (b) 39. - (c) 40. - (b)
41. - (a) 42. - (d) 43. - (b) 44. - (b)
5. TECHNICAL DATA RMPU
45. - (a) 46. - (a) 47. - (d) 48. - (c) 49. - (b)
50. - (b) 51. - (c) 52. - (c) 53. - (a) 54. - (b)
55. - (c) 56. - (b) 57. - (c) 58. - (d) 59. - (a)
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 49
Question Bank on LHB Coaches (Electrical) March, 2021
60. - (b) 61. - (c) 62. - (d) 63. - (b) 64. - (c)
65. - (d) 66. - (a) 67. - (b) 68. - (c) 69. - (d)
70. - (a) 71. - (d) 72. - (d) 73. - (d) 74. - (a)
75. - (b) 76. - (d) 77. - (d) 78. - (b) 79. - (d)
80. - (b) 81. - (c) 82. - (b) 83. - (a) 84. - (b)
85. - (a) 86. - (b) 87. - (a)
6. REGULATED CUM EMERGENCY BATTERY
CHARGER
88. - (a) 89. - (a) 90. - (a) 91. - (d) 92. - (b)
93. - (d)
7. REGULATED BATTERY CHARGER OF REBC
94. - (b) 95. - (d) 96. - (a) 97. - (b) 98. - (d)
99. - (b) 100. - (c) 101. - (d) 102. - (c)
8. EMERGENCY BATTERY CHARGER (OF REBC)
103. - (d) 104. - (a) 105. - (c) 106. - (c)
9. PROTECTIONS FOR REGULATED BATTERY
CHARGER
107. - (b) 108. - (c) 109. - (c) 110. - (d) 111. - (c)
112. - (d)
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 50
Question Bank on LHB Coaches (Electrical) March, 2021
10. PROTECTIONS FOR EMERGENCY BATTERY
CHARGER
113. - (c) 114. - (c) 115. - (c) 116. - (d)
11. LIGHT FITTING
117. - (b) 118. - (b) 119. - (c) 120. - (b) 121. - (d)
122. - (c) 123. - (b) 124. - (b) 125. - (c) 126. - (c)
127. - (a)
12. BATTERY
128. - (a) 129. - (c) 130. - (d) 131. - (a) 132. - (b)
133. - (c) 134. - (a) 135. - (b) 136. - (c) 137. - (b)
138. - (a) 139. - (d) 140. - (a) 141. - (c) 142. - (a)
143. - (c) 144. - (b) 145. - (a) 146. - (b) 147. - (d)
148. - (c) 149. - (c)
13. EOG POWER CAR
150. - (b) 151. - (c) 152. - (c) 153. - (b) 154. - (a)
155. - (b) 156. - (b) 157. - (c) 158. - (c) 159. - (d)
160. - (d) 161. - (c) 162. - (a) 163. - (b) 164. - (b)
165. - (d) 166. - (a) 167. - (c) 168. - (b) 169. - (b)
170. - (c) 171. - (b) 172. - (b) 173. - (d) 174. - (b)
175. - (b) 176. - (c)
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 51
Question Bank on LHB Coaches (Electrical) March, 2021
14. RELAY FOR PROTECTION OF GENERATOR CAR
177. - (c) 178. - (b) 179. - (b) 180. - (a) 181. - (c)
182. - (a) 183. - (c) 184. - (c) 185. - (b) 186. - (c)
187. - (b) 188. - (a) 189. - (c) 190. - (a) 191. - (b)
192. - (c) 193. - (c) 194. - (b) 195. - (d) 196. - (b)
15. PANTRY CAR AND MINI PANTRY EQUIPMENT
197. - (c) 198. - (b) 199. - (a) 200. - (c) 201. - (a)
202. - (c) 203. - (d) 204. - (b) 205. - (c) 206. - (a)
207. - (b) 208. - (c) 209. - (c) 210. - (d) 211. - (a)
212. - (b) 213. - (c) 214. - (b) 215. - (c) 216. - (b)
217. - (c) 218. - (d) 219. - (c) 220. - (b) 221. - (a)
222. - (b) 223. - (a)
16. LHB NON AC COACH
224. - (c) 225. - (a) 226. - (d) 227. - (a) 228. - (a)
229. - (d) 230. - (c) 231. - (c) 232. - (c) 233. - (a)
234. - (b) 235. - (b) 236. - (b) 237. - (a) 238. - (d)
239. - (a) 240. - (c) 241. - (b) 242. - (b) 243. - (c)
244. - (d) 245. - (c) 246. - (b) 247. - (c) 248. - (b)
249. - (c) 250. - (d) 251. - (c) 252. - (b) 253. - (a)
254. - (b) 255. - (d) 256. - (a) 257. - (b) 258. - (d)
259. - (a) 260. - (c) 261. - (a) 262. - (b) 263. - (c)
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 52
Question Bank on LHB Coaches (Electrical) March, 2021
264. - (d) 265. - (d) 266. - (d) 267. - (b) 268. - (a)
269. - (b) 270. - (c) 271. - (b) 272. - (a) 273. - (c)
274. - (b) 275. - (c) 276. - (d) 277. - (a)
17. FILL IN THE BLANKS: CODES OF VARIOUS LHB
COACHES
a. LWFAC b. LWGACCW c. LWACCW
d. LWGACCN e. LWACCN f. LWFCZAC
g. LWSCZAC h. LWCBAC i. LWLRRM
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 53
Question Bank on LHB Coaches (Electrical) March, 2021
NOTE
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 54
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH is continuing its efforts in the documentation and up-gradation
of information on maintenance practices of electrical assets. Over the years a
large number of publications on electrical assets have been prepared in the
form of handbooks, pockets books, pamphlets & video films etc. These
publications have been uploaded on the internet as well as rail net.
For downloading these publications please do following:
1. On internet visit :www.rdso.indianrailways.gov.in
Go to Directorates CAMTECH Publications for download
Electrical Engineering
2. On Railnet visit RDSO website at 10.100.2.19
Go to Directorates CAMTECH Publications for download
Electrical Engineering
For any further information regarding publications please contact:
Dy. Director (Elect.) BSNL: 0751- 2470740 (O)
Rly. : 03747203
SSE/Electrical : 9425341810
E-mail : [email protected]
Fax : 0751- 2470841
Write at : Dy. Director (Electrical)
Indian Railways
Centre for Advanced Maintenance
technology, In front of Hotel Adityaz,
Airport Road, Maharajpur,
Gwalior, Pin code – 474 005