quality care. clinically proven. · quality care. clinically proven. supercable® polymer...

2
Quality Care. Clinically Proven. SuperCable ® Polymer Iso-Elastic™ Cerclage Eliminate Cable-Generated Metal Debris Callaghan (1997) Contribution of cable debris to accelerated poly wear. Clin Orthop. Urban (2004) Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthoplasty. J Arthroplasty. Proven Performance Della Valle (2010) Early experience with a novel nonmetallic cable... Clin Orthop. Edwards (2011) Polymer cerclage cables in revision shoulder... Orthopedics. Berend, Lombardi (2014) Polymer cable/grip-plate for stable fixation... Surg Tech Intl. Superior Fatigue Strength Hack (2005) Novel iso-elastic cerclage cable for treatment of fractures. ORS. Eliminate a Sharps Hazard Stoker (2009) Sharps Safety for Orthopedic Surgeons. Managing Infection Control. Essential for Tourniquet-free TKA Meneghini (2018) Tourniquetless TKA...Decreases Pain & Opioid Consumption in Women. J Arthroplasty. Jones (2011) Total knee arthroplasty without the use of a tourniquet. Seminars in Arthroplasty. Increase Cement Penetration Meneghini (2019) The Effect of Tourniquet Use and Sterile CO 2 Bone Preparation on Cement Penetration in Primary TKA. J Arthroplasty. Goldstein (2007) Improvement of cement mantle thickness with pressurized CO 2 . ISTA. Increase Bone-Cement Interface Strength Stanley (2010) Bone-cement interface strength using two preparation techniques. Hand Surg. Reduce Opportunity for Micro-Emboli Lassiter (2010) Intraoperative embolic events with use of pulsatile saline versus CO 2 lavage. ORS. Reliable: 100% Survivorship at 11 Years Sisto (2006) Custom patellofemoral arthroplasty... JBJS. Sisto (2011) Custom patellofemoral arthroplasty: 11 Year Follow-Up. ORS. Grelsamer (2012) Patient-specific patellofemoral arthroplasty. Recent Advances in Hip and Knee Arthroplasty. Faster Surgery Sisto (2007) Custom patellofemoral arthroplasty: surgical technique. JBJS. KineMatch ® Patient-Matched Patello-Femoral Replacement CarboJet ® CO2 Bone Preparation KineMatch® PFR U.S. Patent Nos. 6,905,514; 6,712,856; 7,517,365; 7,935,150; 8,419,741; 8,771,281; 8,936,601; 8,936,602; 8,961,529; 9,393,032. EU Pat. No. 1,265,559. SuperCable® U.S. Patent Nos. 6,589,246; 7,207,090; 8,469,967; 9,107,720. JAP Pat. No. 4,829,236; 5,938,095. EU Pat. Nos. 1,781,961; 1,389,940; 2,432,401; 3,013,268, 3,181,068 .TUR Pat. Nos. TR201309922T4; TR201405440T4. CarboJet® U.S. Patent Nos. 8,100,851; 8,721,595. JAP Pat. No. 5,735,524. Additional US & International Patents Pending. ©2020 Kinamed® Inc. B00184K Quality Care. Clinically Proven. 1. CT Scan As Easy As... 2. Virtual Model of Patient Anatomy 3. Implant Custom-Made for Patient Anatomy Tibia After Resection After Pulsatile Saline Lavage After CarboJet For a hands-on demo, visit us at the 2020 AAOS Annual Meeting - Booth 2343 Simpler Technique For more information or to schedule an evaluation: 800-827-5775 | 805-384-2748 | www.kinamed.com

Upload: others

Post on 28-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quality Care. Clinically Proven. · Quality Care. Clinically Proven. SuperCable® Polymer Iso-Elastic™ Cerclage Eliminate Cable-Generated Metal Debris Callaghan (1997) Contribution

Quality Care. Clinically Proven.

SuperCable® Polymer Iso-Elastic™ Cerclage

Eliminate Cable-Generated Metal DebrisCallaghan (1997) Contribution of cable debris to accelerated poly wear. Clin Orthop. Urban (2004) Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthoplasty. J Arthroplasty.

Proven PerformanceDella Valle (2010) Early experience with a novel nonmetallic cable... Clin Orthop. Edwards (2011) Polymer cerclage cables in revision shoulder... Orthopedics. Berend, Lombardi (2014) Polymer cable/grip-plate for stable fixation... Surg Tech Intl.

Superior Fatigue StrengthHack (2005) Novel iso-elastic cerclage cable for treatment of fractures. ORS.

Eliminate a Sharps HazardStoker (2009) Sharps Safety for Orthopedic Surgeons. Managing Infection Control.

Essential for Tourniquet-free TKAMeneghini (2018) Tourniquetless TKA...Decreases Pain & Opioid Consumption in Women. J Arthroplasty. Jones (2011) Total knee arthroplasty without the use of a tourniquet. Seminars in Arthroplasty.Increase Cement PenetrationMeneghini (2019) The Effect of Tourniquet Use and Sterile CO2 Bone Preparation on Cement Penetration in Primary TKA. J Arthroplasty.Goldstein (2007) Improvement of cement mantle thickness with pressurized CO2. ISTA.Increase Bone-Cement Interface StrengthStanley (2010) Bone-cement interface strength using two preparation techniques. Hand Surg.

Reduce Opportunity for Micro-EmboliLassiter (2010) Intraoperative embolic events with use of pulsatile saline versus CO2 lavage. ORS.

Reliable: 100% Survivorship at 11 YearsSisto (2006) Custom patellofemoral arthroplasty... JBJS.Sisto (2011) Custom patellofemoral arthroplasty: 11 Year Follow-Up. ORS.

Grelsamer (2012) Patient-specific patellofemoral arthroplasty. Recent Advances in Hip and Knee Arthroplasty.

Faster SurgerySisto (2007) Custom patellofemoral arthroplasty: surgical technique. JBJS.

KineMatch® Patient-Matched Patello-Femoral Replacement

CarboJet ® CO2 Bone Preparation

KineMatch® PFR U.S. Patent Nos. 6,905,514; 6,712,856; 7,517,365; 7,935,150; 8,419,741; 8,771,281; 8,936,601; 8,936,602; 8,961,529; 9,393,032. EU Pat. No. 1,265,559. SuperCable® U.S. Patent Nos. 6,589,246; 7,207,090; 8,469,967; 9,107,720. JAP Pat. No. 4,829,236; 5,938,095. EU Pat. Nos. 1,781,961; 1,389,940; 2,432,401; 3,013,268, 3,181,068 .TUR Pat. Nos. TR201309922T4; TR201405440T4. CarboJet® U.S. Patent Nos. 8,100,851; 8,721,595. JAP Pat. No. 5,735,524. Additional US & International Patents Pending. ©2020 Kinamed® Inc. B00184K

Quality Care. Clinically Proven.

1. CT Scan

As Easy As...

2. Virtual Model of Patient Anatomy

3. Implant Custom-Made for Patient Anatomy

Tibia AfterResection

After Pulsatile Saline Lavage

After CarboJet

For a hands-on demo, visit us at the 2020 AAOS Annual Meeting - Booth 2343

Simpler Technique

For more information or to schedule an evaluation: 800-827-5775 | 805-384-2748 | www.kinamed.com

Page 2: Quality Care. Clinically Proven. · Quality Care. Clinically Proven. SuperCable® Polymer Iso-Elastic™ Cerclage Eliminate Cable-Generated Metal Debris Callaghan (1997) Contribution

Orange County Convention Center

CarboJet® – See how this unique device functions to quickly and easily clear lipids/fatty marrow elements from the bone prior to cementation to improve cement interdigitation and bond strength.*See surgical video of R. Michael Meneghini, MD performing tourniquet-free TKA utilizing CarboJet.

SuperCable® – Experience application and tensioning of this unique “Iso-Elastic” cable and see how the system allows for easy re-tensioning after initial tensioning and locking.

For a hands-on demonstration of these clinically proven products, visit us at the 2020 AAOS Annual Meeting - Booth 2343 - March 25-27 in Orlando.

Quality Care. Clinically Proven.

KineMatch® PFR – Finally, a reliable and simple solution to intractable isolated patello-femoral disease. Let us show you how this unique CT-based, patient-matched device works.*See surgical video of Adolph V. Lombardi, Jr, MD performing a surgical case with KineMatch.

Zimmer

Biomet

Depuy Synthes

Kinamed 2343

1943