quality assurance review center / …rpc.mdanderson.org/rpc/credentialing/3d crt dosimetry...

7
5 QUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER 3D CRT DOSIMETRY SUMMARY INSTITUTION NAME PHYSICIST/DOSIMETRIST RADIATION ONCOLOGIST PHONE PHONE (if different) EMAIL EMAIL DOSE PRESCRIPTION Dose per Fraction to Prescription Isodose Maximum Dose per Fraction in the Planning Target Volume Treatment Machine Intended Number of Fractions Minimum Dose per Fraction in the Planning Target Volume Intended Dose to Prescription Point Minimum Dose per Fraction in the Clinical Target Volume Treatment Planning System (manufacturer/model/ version) TREATMENT TECHNIQUE FIELD I FIELD II FIELD III FIELD IV For this benchmark case: FIELD NAME (ANT, POST, RT LAT, etc.) CT slice thickness: ENERGY, MODALITY (e.g. 6X, 6e) Margin of aperture from target volume: cm SSD Grid size used on axial slices for dose calc: mm GANTRY / COLLIMATOR / COUCH ANGLE / / / / / / / / DVH Site Volume (cc) COLLIMATOR SETTING (W x L or if using independent jaws X 1 , X 2 , Y 1 , Y 2 ) PTV Target Volume EQUIVALENT SQUARE AT SAD / SSD NT1 R Optic Nerve TMR, TAR, % DEPTH DOSE, etc. (type/value) NT2 R Globe DEPTH OF PRESCRIPTION POINT NT3 Pituitary ATTENUATORS: Blocks or Multi-leaf collimators (MLC) (tray factor if applicable) Wedge (angle/factor) Physical Internal Enhanced Dynamic Virtual Compensator (factor, material, thickness) / Bolus (depth) DOSE PER FRACTION MONITOR UNITS PER FRACTION

Upload: hoangdung

Post on 09-Jun-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

5

QUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER 3D CRT DOSIMETRY SUMMARY

INSTITUTION NAME

PHYSICIST/DOSIMETRIST RADIATION ONCOLOGIST

PHONE PHONE (if different)

EMAIL EMAIL

DOSE PRESCRIPTION

Dose per Fraction to Prescription Isodose Maximum Dose per Fraction in the Planning Target Volume

Treatment Machine

Intended Number of Fractions Minimum Dose per Fraction in the Planning Target Volume

Intended Dose to Prescription Point Minimum Dose per Fraction in the Clinical Target Volume

Treatment Planning System

(manufacturer/model/ version)

TREATMENT TECHNIQUE

FIELD I FIELD II FIELD III FIELD IV For this benchmark case:

FIELD NAME (ANT, POST, RT LAT, etc.) CT slice thickness:

ENERGY, MODALITY (e.g. 6X, 6e) Margin of aperture from target volume: cm

SSD Grid size used on axial slices for dose calc: mm

GANTRY / COLLIMATOR / COUCH ANGLE / / / / / / / / DVH Site Volume (cc)

COLLIMATOR SETTING (W x L or if using independent jaws X1, X2, Y1, Y2)

PTV Target Volume

EQUIVALENT SQUARE AT SAD / SSD NT1 R Optic Nerve

TMR, TAR, % DEPTH DOSE, etc. (type/value) NT2 R Globe

DEPTH OF PRESCRIPTION POINT NT3 Pituitary

ATTENUATORS: Blocks or Multi-leaf collimators (MLC) (tray factor if applicable)

Wedge (angle/factor) Physical Internal Enhanced Dynamic Virtual

Compensator (factor, material, thickness) /

Bolus (depth)

DOSE PER FRACTION MONITOR UNITS PER FRACTION

Page 2: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

6

CTV = Red Optic Nerves = Blue & Green Pituitary = Pink Brainstem = Green

Figure I: All axial CT images on which the CTV or any normal tissues (other than skin) are delineated.

Page 3: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

7

Figure II: Reconstructed coronal slice through isocenter showing lateral and vertex beams, CTV (red outline) and normal tissues.

Figure III: A. Reconstructed sagittal slice through isocenter with isodose contours superimposed. Show at least the 6420, 6000, 5800, 5500, 5000, and 3000 cGy contours. B. BEV of right lateral portal showing collimators, beam aperture, PTV, right globe, right optic nerve, pituitary and brain stem.

A B

Page 4: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

8

Figure IV A Reconstructed sagittal slice through isocenter with isodose contours superimposed. Show at least the 6420, 6000,

5800, 5500, 5000, and 3000 cGy contours B. BEV of vertex portal showing collimators, beam aperture, PTV, and all normal tissues except skin.

Figure V: Axial CT slice at isocenter with CTV and isodose contours superimposed. Show at least the 6420, 6000, 5800, 5500, 5000, and 3000 cGy contours.

A B

Page 5: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

9

Figure VI: Axial CT slice at the level of the right optic nerve with the pituitary, globes, optic nerves and brain stem delineated and isodose contours superimposed. Show at least the 6420, 6000, 5800, 5500, 5000, and 3000 cGy contours.

Figure VII: Right lateral DRR with PTV and beam aperture superimposed. (Include a linear scale.)

Page 6: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

10

Figure VIII: AP DRR (include a linear scale.)

Figure IX: Dose-volume histogram for the planning target volume. Note that this DVH does not satisfy the dose prescription defined in Section 5.

Page 7: QUALITY ASSURANCE REVIEW CENTER / …rpc.mdanderson.org/rpc/credentialing/3D CRT Dosimetry Summary.pdfQUALITY ASSURANCE REVIEW CENTER / RADIOLOGICAL PHYSICS CENTER ... SSD Grid size

11

Figure X: Dose-volume histogram for the right optic nerve, right globe, pituitary, and brain stem.