qlogic hba installation
TRANSCRIPT
-
8/3/2019 Qlogic HBA Installation
1/128
EMC Corporation
Corporate Head qua rters:
Hop kinton, MA 01748-91031-508-435-1000www.EMC.com
EMC Fibre Channel and iSCSI with
QLogic Host Bus Adapters in the
Windows Environment
P/ N 300-001-164REV A13
-
8/3/2019 Qlogic HBA Installation
2/128
-
8/3/2019 Qlogic HBA Installation
3/128
-
8/3/2019 Qlogic HBA Installation
4/128
EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent4
Contents
Chapter 2 Miscellaneous Planning and Procedures
Zoning an d connection p lanning in a fabric environm ent ......... 78Installing and configuring the QLogic QLA4010 iSCSI
HBA (TOE)......................................................................................... 79
Using th e QLogic iSCSI SAN surfer application to
configu re iSCSI devices ............................................................ 79
Configuring iSNS settin gs for QLA4010................................ 81
Booting from SAN with QLogic QLA40xx and Microsoft
Initiator ............................................................................................... 87
Boot-from-SAN configu ration restrictions.................................... 90Benefits of boot ing from the storage array ............................ 90
Setting up external boot for IBM BladeServer HS40 (8839)........ 91
Configuring an HS40 BladeCenter server to boot from an
extern al array ............................................................................. 91
Blad eServer r estrict ions ............................................................ 92
Manually installing the HBA driver Advanced users.............. 93
Driver revision ........................................................................... 93
Where to find the driver ........................................................... 94Window s 2003 STORPor t updates .......................................... 94
Migrat ing Windows 2003 dr ivers from SCSI to STOR......... 95
Installation procedure for Window s 2000 and
Win dow s 2003 hosts.................................................................. 96
Upd ating the H BA driver in a Wind ows 2000 or Window s
2003 host ..................................................................................... 97
Upgrad ing to Window s 2003 from Window s 2000.............. 98
Editing th e Wind ow s time-out value ..................................... 99QLogic ad vanced utilities .............................................................. 100
Upd ating QLogic firmware/ BIOS and app lying N VRAM
set tings ...................................................................................... 100
Updatin g while runn ing Wind ow s....................................... 100
Upd ating th e flash BIOS using SANsurfer FC HBA
Manager .................................................................................... 101
QLogic SANsurfer SANblad e Manager ............................... 103
Procedure for replacing a QLogic HBA in Stratus ftServers
withou t reboot ing ........................................................................... 104
EMC CLARiiON storage ar rays ............................................ 104
EMC Symmetrix arrays w ith d evice masking enabled ...... 105
Special instru ctions for the EMC CLARiiON CX200 series...... 107
Set th e H BA FC-AL loop ID ................................................... 107
Direct-connect dual-host clustering configurations ........... 108
-
8/3/2019 Qlogic HBA Installation
5/128
5EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad ap ters in the Wind ow s Environm ent
Contents
Chapter 3 Troubleshooting
Opera ting system/ d river capabilities and limitations .............. 112LUN s .......................................................................................... 112
Volu me Sizes ............................................................................ 112
Extend ed error loggin g by QLogic d rivers.................................. 114
Understanding persistent binding ................................................ 115
Know n issues ................................................................................... 118
Problems an d solu tions .................................................................. 119
Problem 1................................................................................... 119
Problem 2................................................................................... 119Problem 3................................................................................... 119
Problem 4................................................................................... 120
Problem 5................................................................................... 120
Problem 6................................................................................... 120
Problem 7................................................................................... 121
Problem 8................................................................................... 121
Appendix A Third-Party Software
QLogic SAN surfer SAN blade Man ager ...................................... 124
SANsurfer version his tory ...................................................... 124
VERITAS Volum e Managem ent Software for Window s
operating systems .......................................................................... 126
VERITAS Volu me Manager 3.0.............................................. 126
VERITAS Volume Manager 3.1 and VERITAS DMP ......... 127
VERITAS Found ation Suite 4.1 .............................................. 127VERITAS Found ation Suite 4.2 .............................................. 127
VERITAS Found ation Suite 4.3 .............................................. 128
-
8/3/2019 Qlogic HBA Installation
6/128
EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent6
Contents
-
8/3/2019 Qlogic HBA Installation
7/128
EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad ap ters in the Wind ow s Environm ent 7
Title Page
1 Installation and Configuration Overview .................................................. 17
2 PCI slot types and voltage key locations .................................................... 20
3 HBA edge connecters ..................................................................................... 21
4 PCI Express slots ............................................................................................ 22
5 PCI Express slots aligned .............................................................................. 22
6 QLogic banner ................................................................................................ 27
7 Main Fast!UTIL options w indow ................................................................. 28
8 Configuration settings window ................................................................... 29
9 Adapter settings wind ow .............................................................................. 29
10 Configu ration settings wind ow ................................................................... 30
11 Selectable boot settings window .................................................................. 30
12 Select Fibre Channel Device w indow .......................................................... 31
13 Examp le of LUN 17 allocated to HBA ......................................................... 3214 Selectable boot settings window .................................................................. 33
15 Warning d ialog ............................................................................................... 33
16 Fast!UTIL options w ind ow ........................................................................... 34
17 QLogic BIOS banner screen .......................................................................... 34
18 Firmw are boot manager menu ..................................................................... 36
19 Device m apping table .................................................................................... 37
20 Reference to QLogic Fibre Channel driver ................................................. 38
21 QLogic d irectory ............................................................................................. 3922 Fibre Chan nel Card Efi u tility ...................................................................... 40
23 QLogic efiutil all upgrad e ............................................................................. 41
24 Utililty install .................................................................................................. 42
25 Data loaded onto HBA(s) installed in server ............................................. 43
26 QLogic HBA instances with specific firmw are version ............................ 44
27 QLogic Fibre Channel dr ivers ...................................................................... 44
28 Driver hand le num bers ................................................................................. 45
29 Fibre Channel driver configuration u tility ................................................. 4630 Edit ad apter settings ...................................................................................... 46
Figures
-
8/3/2019 Qlogic HBA Installation
8/128
EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent8
Figures
31 Connection option .......................................................................................... 47
32 Example array p ort WWN and LUN values .............................................. 48
33 Op tions set ...................................................................................................... 49
34 Exam ple blkD as array p ort .......................................................................... 49
35 Window s setup screen with F6 prom pt ...................................................... 53
36 Specifying a driver for your HBA ................................................................ 54
37 HBA selection screen ..................................................................................... 55
38 Wind ows setup screen .................................................................................. 56
39 Existing pa rtitions .......................................................................................... 57
40 SANsurfer dr iver installation type .............................................................. 61
41 SANsurfer dr iver install wizard welcome ................................................. 62
42 SAN surfer driver selection ........................................................................... 63
43 SANsu rfer installation w ith version nu mber ............................................ 64
44 SANsurfer Java agent service message ....................................................... 65
45 SANsu rfer driver installation comp leted successfully ............................. 66
46 SANsurfer d river installation comp lete ...................................................... 67
47 SAN surfer HBA install wizard .................................................................... 68
48 SANsurfer install w izard attach storage ..................................................... 6949 SANsurfer H BA installation diagnostics results ...................................... 70
50 Show SAN tree ............................................................................................... 71
51 SAN surfer icon ............................................................................................... 72
52 Connect to the h ost ........................................................................................ 73
53 SANsurfer, SANsurfer FC HBA manager .................................................. 74
54 SANsurfer iSCSI HBA Manager, connect to host ...................................... 80
55 SANsurfer iSCSI HBA manager, HBA options ......................................... 81
56 SANsurfer iSCSI HBA manager, HBA options, firmw are tab ................ 8257 Dow nload firm ware d ialog .......................................................................... 83
58 SANsu rfer iSCSI HBA manager, HBA options, BIOS tab ........................ 83
59 SANsu rfer iSCSI HBA man ager, target settings tab ................................. 84
60 SANsurfer iSCSI HBA Manager, Target sett ings, IP Address
dialog ................................................................................................................. 84
61 Auth entication configura tion, CHAP tab ................................................... 85
62 SANsu rfer iSCSI HBA Manager, Information tab .................................... 86
63 Utilities tabbed page .................................................................................... 10264 Reconfigu re the HBA jumper ..................................................................... 110
65 Original configuration before the reboot .................................................. 117
66 Host after the rebooted ................................................................................ 117
-
8/3/2019 Qlogic HBA Installation
9/128
-
8/3/2019 Qlogic HBA Installation
10/128
-
8/3/2019 Qlogic HBA Installation
11/128
EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad ap ters in the Wind ow s Environm ent 11
Preface
As part of an effort to improve and enhance the performance and capabilities
of its product line, EMC from time to time releases revisions of its hardware
and software. Therefore, some functions described in this document may not
be supported by all revisions of the software or hardware currently in use.
For the most up-to-date in formation on product features, refer to your
product release notes.
Audience This guide is intend ed for custom ers who need to install anEMC-app roved QLogic host bus ad ap ter into a Window s 2000 or
Wind ows 2003 host environment or to configuring th e Wind ows h ost
for connection to an EMC storage array over Fibre Chann el.
Relateddocumentation
Related documents include:
EMC Host Connectivity Guide for Windows, P/ N 300-000-603
EMC Navisphere Manager 5.X Administrators Guide, P/ N
069001143
EMC Navisphere Manager 6.X Administrators Guide, P/ N
069001125
EMC ControlCenter Navisphere Host Agent and CLI for Windows
Version 6.X Installation Guide, P/ N 069001151
Storage-System Host Utilities for Windows 2000 and N T
Administrator's Guide, P/ N 069001141
PowerPath Installation A nd A dministration Guide for Windows, P/ N
300-000-512
-
8/3/2019 Qlogic HBA Installation
12/128
12 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Preface
Conventions used inthis guide
EMC uses the following conventions for notes, cau tions, and
warnings.
Note: A note p resents information that is important, but not hazard -related.
IMPORTANT!An important notice contains in formation essential to operation of
the sof tware.
CAUTION!A caution contains information essential to avoid data loss or
damage to the system or equipment. The caution may apply to
hardw are or sof tware.
WARNING
A w arning conta ins informat ion essential t o av oid a hazard that can
cause severe personal injury, death, or subst antial property damage
if you ignore the warning.
Typographica l conventionsEMC uses the following typ e style conventions in th is guide:
Normal Used in running (nonprocedural) text for:
Names of interface elements (such as names of windows, dialogboxes, buttons, fields, and menus)
Names of resources, attributes, pools, Boolean expressions,buttons, DQL statements, keywords, clauses, environmentvariables, filenames, functions, utilities
URLs, pathnames, filenames, directory names, computer names,links, groups, service keys, file systems, notifications
Bold: Used in running (nonprocedural) text for:
Names of commands, daemons, options, programs, processes,services, applications, utilities, kernels, notifications, system call,man pages
Used in procedures for:
Names of interface elements (such as names of windows, dialogboxes, buttons, fields, and menus)
What user specifically selects, clicks, presses, or types
-
8/3/2019 Qlogic HBA Installation
13/128
-
8/3/2019 Qlogic HBA Installation
14/128
14 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Preface
-
8/3/2019 Qlogic HBA Installation
15/128
Insta llation a nd Co nfiguration 15
1Invisible Body Tag
This chap ter describes the p rocedu res for installing an
EMC-approved QLogic host bus adapter (HBA) into a Window s 2000
or Wind ows 2003 host environmen t and configuring the Window s
host for connection to an EMC storage arr ay over Fibre Chann el.
Note: Review theEMC Support Matrix for the latest informa tion on app roved
HBAs and drivers.
How th is gu ide works ....................................................................... 16
Installing th e HBA ............................................................................. 18
Booting from the external storage ar ray ......................................... 24
Insta lling the Window s operating system ...................................... 52
Insta lling HBA driver and softw are utilities .................................. 60
Verifying connectivity to the storage ar ray .................................... 72
Installation andConfiguration
-
8/3/2019 Qlogic HBA Installation
16/128
16 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Installation and Configuration
How this guide works
In an effort to simp lify the installation and configuration of QLogic
Fibre Chann el HBAs, this guide follows a simp le flow chart, as
shown in Figure 1 on page 17, that gu ides you through the necessary
procedu res to connect your Wind ows server to EMC storage arrays.
Tips on p lanning, miscellaneous p rocedures, and troubleshooting
information are located in Chap ter 2, Miscellaneou s Planning and
Procedures, an d Chap ter 3, Troubleshooting.
This docum ent will guide you throu gh the following steps:
1. Installing the H BA on p age 18
2. Booting from the external storage array on page 24:
a. If notinstalling an IA-64 or EFI-based server:
Create a floppy d isk with the EMC-approved dr iver and
BIOS on p age 24. Install/ up grad e firmw are and boot BIOS from DOS on
page 25.
QLogic QLA23xx-based FibreChannel HBA BIOS/ boot
LUN settings on page 26.
Verifying array/ LUN visibility for boot on page 50
b. If installing an IA-64 or EFI-based server:
Installing a RAMDISK und er the EFI shell on p age 50
3. Installing the Wind ows operating system on p age 52.
4. Installing H BA driver and software utilities on page 60.
5. Verifying connectivity to the storage array on page 72.
Downloading latest QLogic drivers/ firmwa re/ BIOS filesThroughou t this docum ent, there are references to up dated files from
QLogic. All of the versions includ ed on the QLogic CD packaged
with your H BA are current as of this documen ts release. However,
there may be up dates to these files that m ay be necessary to
dow nload. For these, use the QLogic website,
http:///www.qlogic.com. From the main page on the QLogic
website, clickDownloads link on the left side of the p age. On the
resulting supp ort page, click the EMC link un der the OEM Modelssection. On the resu lting page, click the EMC Array category for your
-
8/3/2019 Qlogic HBA Installation
17/128
How this guide wo rks 17
Installation and Configuration
storage array. On th e resulting EMC Approved Software page, it is
possible to dow nload the m ost recent EMC-approved dr ivers and
BIOS files as well as d ocumen tation an d helpful software tools.
Figure 1 Installation and Configuration Overview
Create a floppy diskwith EMC-approveddriver, firmware, and
boot BIOS
Install firmware andboot BIOS from DOS
Copy the EMC-approveddriver and firmware, andthe Intel EFI RAMDISK
driver to a USB pen drive
or floppy disk to be usedin a USB floppy drive
Install firmware andEFIBoot driver from
EFI Shell
Are youinstalling an IA-64
or EFI-based
server?
Configure theQLogic Boot BIOS
Configure theEFIBoot driver
N Y
Start
Installing the HBA(s) into the server
Bootingfrom the externalstorage arrays?
YES NO
Bootingfromt
heExternal
StorageArray
Install Windows OS
Install HBA Driver and
Software Utilities
Verify Connectivity to the
Storage Array GEN-000017Q
Verify Array/LUNVisibility for Boot
-
8/3/2019 Qlogic HBA Installation
18/128
-
8/3/2019 Qlogic HBA Installation
19/128
-
8/3/2019 Qlogic HBA Installation
20/128
20 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Installation and Configuration
of the HBA. Insert ing a 3.3v HBA into a 5v slot would cau se severe
dam age to both the HBA and the server. Therefore, the slot keys
denote the typ e of voltage provided by the slot and effectivelyprevent a voltage incomp atible HBA from being inserted.
Figure 2 shows how PCI slots will app ear with their keys and w hat
type of voltage is provided for each slot type.
Figure 2 PCI slot types and voltage key loca tions
Figure 3 on page 21 show s the HBA edge connecters comp atible with
the PCI slots show n in Figure 1 on page 17. Note HBA #5 which
shows a universal HBA edge connecter. Universal HBAs are
compatible with both 3.3v and 5v PCI slots.
-
8/3/2019 Qlogic HBA Installation
21/128
-
8/3/2019 Qlogic HBA Installation
22/128
-
8/3/2019 Qlogic HBA Installation
23/128
Installing the HBA 23
Installation and Configuration
QLogic offers HBAs for each bus/ slot type ava ilable. Table 1 shows
each of the EMC-sup ported QLogic HBAs, and their respective slot
requirements. Be sure to consult both your server user guide andQLogic to insure that th e HBA you want to u se is compat ible with
your server s bus.
Remember that som e of the older H BAs are tall (also referred to as
full-height) and may not fit into a server w ith a low -profile chassis.
These factors must be considered before imp lementing you r
configuration to avoid unnecessary delays and possible equipm entswaps or returns.
Table 1 EMC-supported QLogic HBAs
HBA PCI spec BUS length Power Slot key
QLA2200F PCI 2.1 64-bit 3.3V, 5V Universal
QLA200 PCI-X 1.0a & PCI 2.2 32-bit 3.3V, 5V 3.3V
QLA210 PCI-X 1.0a & PCI 2.2 32-bit 3.3V 3.3V
QLA2310F PCI-X 1.0a & PCI 2.2 64-bit 3.3V, 5V Universal
QLA2340LF PCI-X 1.0a & PCI 2.2 64-bit 3.3V, 5V Universal
QLA2342LF PCI-X 1.0a & PCI 2.2 64-bit 3.3V, 5V Universal
QLE2360 PCI Express x4 lane 3.3V n/a
QLE2362 PCI Express x4 lane 3.3V n/a
QLA2460 PCI-X 2.0a & PCI 2.3 64-bit 3.3V 3.3V
QLA2462 PCI-X 2.0a & PCI 2.3 64-bit 3.3V 3.3V
QLE2460 PCI Express x4 lane 3.3V n/a
QLE2462 PCI Express x4 lane 3.3V n/a
QLE220 PCI Express x4 lane 3.3V n/a
-
8/3/2019 Qlogic HBA Installation
24/128
-
8/3/2019 Qlogic HBA Installation
25/128
Boo ting from the e xterna l storag e a rray 25
Installation and Configuration
Note: NVRAM is short for N on-volatile RAM. This is a special portion of
mem ory on the HBA wh ere HBA settings are stored.
Note: Driver and BIOS files may not fit on the same flopp y. If you run out of
disk space, use a single flopp y d isk for the d river files, and another d isk for
the BIOS files.
Install/ upgrade firmwa re and boot BIOS from DOSTo u pd ate using a DOS boot d iskette, follow these steps:
1. Format a 3.5-inch d iskette and extract the BIOS and NVRAM files
from the archive file (.zip or self-extracting .exe) onto the
diskette. Make sure flasutil.exe and the sou rce files
ql23rom.bin/ql2322rm.bib/2322ipx.bin are in the same
directory. EMC-specific settings are contain ed in files nam ed
emcXXXX.def an d emcXXXX.dat where XXXX is the model num berof the HBA. These settings files (also referred to as NVRAM
setting files) shou ld also be in th e same directory with the flash
utility and source files. Note that som e versions of BIOS may use
different filenam es for dep end ing on the version and H BA mod el.
Be sure to check the readme includ ed with the BIOS files to make
sure you have all of the app ropriate files before proceeding to
step 2.
2. Reboot your Windows host system u sing a DOS diskette.
3. At theA:\> prom pt, insert the diskette that contains the QLogic
BIOS files (created in step 1).
4. Run FlasUtil program by typing flasutil at the comm and
prompt.
5. If the QLX23XX controller is detected, the following is displayed :
QL23XX Adapter found at I/O address: xxxx
Note: If the QL23XX controller is not detected , run flasutil again withthe /I (Ignore Subsystem ID) option.
6. Select F to w rite Flash. FlasUtil wr ites Flash to ad apter using
ql23rom.bin or ql2322rm.bin found in the same d irectory.
-
8/3/2019 Qlogic HBA Installation
26/128
-
8/3/2019 Qlogic HBA Installation
27/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
28/128
28 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Installation and Configuration
Figure 6 QLogic banner
2. Select the HBA (enumerated by its I/ O add ress) to be used for
boot.
If mu ltiple HBAs are installed, there w ill be m ultiple H BA entr ies.
The order of the H BA instances listed is the ord er they w ill be
scanned for a boot device; (note that th is does not necessarily
correspond to PCI slot numbering), and p ress Enter.
Figure 7 Main Fast!UTIL options window
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
29/128
Boo ting from the e xterna l storag e a rray 29
Installation and Configuration
3. Select Configuration Settings from the main Fast!UTIL Options
dialog, and press Enter.
Figure 8 Configuration settings window
4. Select Adapter Settings from the Configuration Settings
window and press Enter.
Figure 9 Adapter settings window
5. The Host Adapter BIOS setting is Disabled by d efault; select this
setting and press Enter to enable Host Adapter BIOS.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
30/128
30 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
g
Press Esc to return to the p revious Configuration Settings (as
shown in Figure 8 on page 29).
Figure 10 Configuration settings window
6. From the Configuration Settings dialog, select Selectable Boot
Settings and p ress Enter.
Figure 11 Selectable boot settings window
7. Selectable Boot is Disabled by default. Select this setting and
press Enter to enable Selectable Boot.
8. Scroll down to the (Primary) Boot Port Name, LUN: setting, and
press Enter.
The Fast!UTIL will now scan for attached FC devices (as show n
in Figure 12 on page 31). If physical connectivity to th e array is
setup p roperly via zoning, then the array port w ill be found a fter
this scan. Use the an d keys to navigate
the list of target IDs for the arr ay p ort being used for boot.
-
8/3/2019 Qlogic HBA Installation
31/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
32/128
32 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
For example, Figure 13 shows that LUN 17 is masked to the HBA.
The LUN is available and is presented as "Sup ported " by the
BIOS.
Figure 13 Example of LUN 17 a llocated to HBA
If no nu mbered entries app ear in the above figure, verify the
following:
For CLARiiON arrays, verify the single I/ O path points to the
SP that owns the boot LUN.
Verify array LUN m asking settings are configured so this HBA
has visibility to the ap prop riate LUN. Refer to array software
documentation for details.
10. Select a sup ported LUN to use as the boot LUN (shown as LUN
17 in Figure 13) and p ressEnter.
The Selectable Boot Settings dialog is displayed (Figure 14 on
page 33) with the upd ated array port and LUN num ber as the
boot d evice.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
33/128
Boo ting from the e xterna l storag e a rray 33
Figure 14 Selectable boot settings window
11. Press Esc to return to the previous Configuration Settings dialog.
12. Press Esc on the Configuration Settings dialog.
A dialog will appear to warn of a configuration change (as shown
in Figure 15).
Figure 15 Warning dialog
13. If the settings a re correct, select Save changes to return to the
initial Fast!UTIL Options dialog.
Otherw ise, press Esc to m ake additional changes, or select Do not
save changes and p ress Enter to return to th e initial Fast!UTIL
Options wind ow (as shown in Figure 16 on page 34).
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
34/128
34 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 16 Fast!UTIL options window
14. To exit the Fast!UTIL configura tion u tility, select Exit Fast!UTIL
and p ress Enter.
The system w ill now reboot.
During the su bsequent reboot, the QLogic BIOS banner screen sh ould
show t he array an d LUN specified as a boot-capable LUN (as show n
in Figure 17).
Figure 17 QLogic BIOS banner screen
At this po int, the OS Installation can begin u sing this LUN as the bootvolume.
-
8/3/2019 Qlogic HBA Installation
35/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
36/128
36 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 18 Firmware boot manager menu
-
8/3/2019 Qlogic HBA Installation
37/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
38/128
38 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
The file system you select depends upon what media contains
the QLogic EFI boot code/ utility. In this examp le, the QLogic
EFI boot code/ utility resides on the USB mem ory d rive.3. Point the EFI shell to the proper file system by typing fsN: (where
Nis the nu mber w hich references the p roper file system) followed
by Enter.
4. Before loading the QLogic EFI boot code/ driver to the HBA(s),
ensure tha t any old EFI boot code load ed in th e system has been
removed . Type drivers at the EFI shell promp t and press Enter.
a. Look for any driver listings that reference "QLogic Fibre
Chann el Adap ter," similar to the listing show n in b.Figure 20
Figure 20 Reference to QLogic Fibre Channel driver
b. If such a driver entry exists in the outp ut, it should be
removed before installing the curren t dr iver. Make note of thefirst two d igits on the line which references the QLogic Fibre
Chann el Driver ("60" in th e examp le shown in Figure 20); th is
is the "driver handle". Type unload .
For the examp le show n in Figure 20, unlo ad 60 wou ld be used
to remove the EFI dr iver. The system w ill prom pt to "Unload
Protocol Image (y/ n)?". Type y and p ress Enter. The existing
QLogic EFI driver w ill now be removed .
5. Type dir and p ress Enter to list the conten ts of the d irectory. If the
directory contents are not consistent with w hat you expect, and
do n ot app ear to contain the QLogic boot code/ utility, the file
system select may be incorrect.
6. Verify the prop er file system has been selected. If the QLogic boot
code/ utility resides in a subd irectory, type cd subdirectory an d
press Enter.
-
8/3/2019 Qlogic HBA Installation
39/128
-
8/3/2019 Qlogic HBA Installation
40/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
41/128
Boo ting from the e xterna l storag e a rray 41
Figure 23 QLogic efiutil all upgrade
The utility will upgrade EFI boot code drivers on all HBAs
installed in th e server and retu rn to the EFI shell when
complete (as show in Figure 23). If any errors are reported
du ring th is process, verify tha t the correct EFI boot code d river
for your H BA has been copied to you r installation m edia.
3. EFI-comp atible firmw are must now be loaded onto the HBA(s).
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
42/128
42 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
a. Typ e efiutil all rw=qlNNNNfw.bin, where NN NN refers to
the chipset version on the H BA. In the example shown in
Figure 21 on page 39, "2312" refers to the chipset present onQLA2340/ QLA2342 HBAs.
b. Press Enter.
Figure 24 Utililty install
-
8/3/2019 Qlogic HBA Installation
43/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
44/128
44 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
7. Press Enter to access the file system contain ing th e QLogic EFI
boot code.
If the EFI boot code resides in a subdirectory, type cd and p ress Enter.
8. Type efiutil to start the QLogic EFI Utility an d press Enter.
At this point, the QLogic HBA instances should be shown
with a sp ecific firmw are version, and "AUX" shou ld n ot be
listed next to the firmw are, as show n inFigure 26.
At this point, the EFI drivers, firmw are, and NVRAM settings
have load ed to th e HBA(s).
Figure 26 QLogic HBA instances with specific firmware version
9. Type q and p ress Enter to exit the QLogic EFI Utility.
10. At the EFI shell prompt, type drivers and p ressEnter. Note the
entr ies that reference "QLogic Fibre Channel Adap ter" are similar
to the listing show n in Figure 27..
Figure 27 QLogic Fibre Channel drivers
11. Make note of the first two d igits (referred to as the "driver
handle") on the line that references the "QLogic Fibre Channel
Driver". If multiple HBAs are installed in the server, there will be
mu ltiple entries, as shown in Figure 27.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
45/128
Boo ting from the e xterna l storag e a rray 45
The order of the H BA instances listed is the ord er in w hich they
have been enu merated by th e system. This does not necessarily
correspond to PCI slot numbering. In th is example, the tw oQLogic HBAs installed in the server are using d river handles 5F
and 60, respectively.
a. Typ e drvcfg.
b. Press Enter.
Figure 28 Driver handle numbers
12. Find the d river hand le numbers that correspond to those listed
for the QLogic HBAs (as show n in Figure 28). Note th e two d igits
(proceeded by Ctrl, as show n in Figure 28) next to the d river
handles for the QLogic HBAs. These are control han dles.
13. Determine the H BA instance that w ill be used for boot, and enterthe QLogic Fibre Channel Driver Configuration Utility by
typing drvcfg -s (where
driver hand le and control handle are the values that correspond
to the H BA instance to be u sed for boot. In this example, "drvcfg
-s 5f 62" is used .)
14. Press Enter.
The Fibre Channel Driver Configuration Utilii ty menu will be
displayed (as shown in Figure 29 on page 46).
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
46/128
46 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 29 Fibre Channel driver configuration utility
15. Type 1 (Edit Adapter Settings) and press Enter.
Figure 30 Edit adapter settings
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
47/128
Boo ting from the e xterna l storag e a rray 47
By default , option 1 (Enable Hard Loop ID) is disabled.
In FC-SW environments, the default of disabled is the
proper setting.
Select 2. Auto Topo logy: Pt to Pt first.
Press Enter when your choice has been selected. The
Topology information toward th e top of the screen will
reflect you r selection.
Press to return to the p revious configuration
window.
In FC-AL/ "direct attach" environments, Hard Loop ID
should be enabled.
Type 1 and p ress Enter. The utility will prom pt to Enable
Hard Loop Id [n]?.
Type y and p ress Enter. Enable Hard Loop Id will now be
shown as [y] (enabled).
Type 0 and p ress Enter to return to the previous m enu asshown in Figure 29 on page 46.
Figure 31 Connec tion option
By d efault, option 6 (Connection option) setting ofLoop
Preferred, Otherwise Point To Point, is acceptable for m ost
configurations, and will au to-detect th e connection topology.
To manually set the connection topology, type 6 and p ressEnter. Otherwise, type 0 and p ress Enter to return to the
previous menu as shown inFigure 29 on page 46.
In FC-SW environments, Point To Point is the appropriate
setting. In FC-AL/ "direct attach" environm ents, Loop Only
should be selected.
Type the app ropriate selection and press Enter. The
selected connection topology will now be reflected.
Type 0.
Installation and Configuration
P E t t t t th i h i
-
8/3/2019 Qlogic HBA Installation
48/128
48 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Press Enter to return to the previous menu as shown in
Figure 29 on page 46.
Option 3 (Edit Database) allows the appropriate WWN of thearray p ort, and th e LUN ad dress, to be specified for boot.
Figure 32 Example array port WWN and LUN values
Type 3 and p ress Enter.
Select 0 to select the first WWN database entry.
Press Enter.
The utility prom pts for Entry 0 Port WWN .
16. Type the full WWN of the array port being used for boot and
press Enter.
The utility prom pts for Node WWN .
17. Enter the same WWN u sed above and p ress Enter.
The utility prom pts for the hexadecimal LUN ad dress to be usedfor boot;
18. Type the ap propriate hexadecimal LUN value to be u sed for boot
and p ress Enter. Figure 32 shows example array-port WWN and
LUN values.
Note:This utility does not explicitly check the values entered for validity,
care must be taken to ensure that the proper array p ort WWN and LUN
add resses have been entered.
The utility will prom pt for another WWN d atabase entry to
modify,
19. Press Enter to return to the menu as shown in Figure 29 on
page 46.
20. Save the configuration changes by typing 11 (Write) and pressEnter.
-
8/3/2019 Qlogic HBA Installation
49/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
50/128
50 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Verifying array/ LUN visibility for boot
Verification of the H BA ability to access the boot LUN, and boot BIOSsettings is recomm ended before installing the OS. Care mu st be taken
to ensure that only a single I/ O p ath to the LUN exists when
installing th e OS, a single H BA should have access to only a single
array p ort at th is point. Selecting BIOS and Boot LUN configuration
settings vary with H BA vend or.
Refer to your arr ay d ocumen tation for details on verifying H BA
connectivity.
Installing a RAMDISK under the EFI shell
Intel provides an EFI toolkit on th e Intel website
http:/ / ww w.intel.com/ technology/ efi. Included in the EFI toolkit is
the RAMDISK driver. To install the RAMDISK dr iver on your system ,
copy the RAMDISK.EFI file to you r USB flash d rive.
Insert the USB flash dr ive in you r EFI-based server s USB port and
boot the server to the EFI shell. At the shell promp t, locate your USB
flash d rive in the device mapping tab le. A line similar to the
following shou ld be listed in the mapp ing table:
Fs0: Acpi (PNPOA03,0)/Pci (1D|1)Usb(1,0)/HD(Part1,Sig0D0C0B0A)
Switch to th e USB flash d rive by typ ing in th e corresponding FS
nu mber, followed by a colon (i.e., Fs0:) and press Enter.
At the FS prom pt, type Load RAMDISK.EFI and p ress Enter. You
should see the message noting that the d river has loaded successfully.
To locate the new RAMDISK, type Exit and p ress Enter. From the
system Boot Manager m enu , select EFI Shell to go back to th e EFI
Shell. The device map shou ld now show a new FS device as well as
the previous USB device.
Note: The order of the devices may h ave shifted with the discovery of the
RAMDISK.
Fs0: VenMsg(06ED4DD0-FF78-11D3-BDC4-00A0C94053D1)Fs1: Acpi (PNP0A03,0)/Pci (1D|1)/Usb(1,0)/HD(Part1,Sig0D0C0B0A)
In the above example, the RAMDISK is now Fs0. Now you can copy
your driver files for you r HBA to the RAMDISK. Sw itch to your USBflash d rive with the dr iver files and copy the files to the RAMDISK by
Installation and Configuration
using the copy comm and. As w ith DOS, the copy command can u se
-
8/3/2019 Qlogic HBA Installation
51/128
Boo ting from the e xterna l storag e a rray 51
using the copy comm and. As w ith DOS, the copy command can u se
an asterisk to grab mu ltiple files, (i.e., Copy *.* fs0:).
Once the files are copied to th e RAMDISK, you m ay p roceed to installWindows.
Note: If the server is rebooted at an y time, this procedu re will need to be
repeated as the RAMDISK is deleted d uring a reboot.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
52/128
52 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Installing the Windows operating system
This section is a step-by-step p rocedu re for installing Wind ows
2000/ 2003 Operating System to either an internal or external boot
device.
After you have your HBA(s) installed in you r server, and configured
for external boot if necessary, the next step is to install the Windows
operating system. If you intend to boot to an external device please
refer to Booting from the external storage array on p age 24 for
setting the boot BIOS for external boot and selecting the external bootlun . If your system is EFI-based refer to Installing a RAMDISK
und er the EFI shell on p age 50. Also refer to your servers
docum entation for preparing you r server for external boot.
Note: If you intend to boot to an external disk, only present the LUN that you
intend to boot from. All add itional lun s can be add ed after the installation.
This will eliminate any confusion on selecting the correct part ition for
installation and eliminates any problems that the Operating System couldencounter on reboot du ring the installation. Also confirm th ere is only one
path to the storage array. Having m ore than one p ath can cause the operating
system to fail du ring the installation.
You n eed th e following m aterials to install Wind ows:
A Wind ows CD-ROM for the Window s version you w ish to
install
AN EMC-app roved H BA driver diskette for Window s, or an EFI
RAMDisk if it is an EFI based install
To install Windows:
1. Insert a bootable Window s CD-ROM in the drive and reboot the
system. If your system h as a bootable disk already configured
from a previous installation, the software will promp t you to
press any key to boot from CD-ROM.2. If you are installing Window s to boot from an external array disk,
you w ill need to su pp ly setup w ith the H BA driver. To do th is,
imm ediately after the Windows installation begins, press F6
wh en d irected or w hen the blue screen ap pears. Otherwise,
proceed to step 6.
Pressing F6 tells the Wind ows installer you want to load a
third-par ty driver before proceeding w ith the installation.
-
8/3/2019 Qlogic HBA Installation
53/128
-
8/3/2019 Qlogic HBA Installation
54/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
55/128
Insta lling t he Wind ow s op era ting system 55
Figure 37 HBA selection screen
5. Select the appropriate boot HBA and p ress Enter. (You may have
to scroll dow n to find the approp riate driver.)
Note: Depending on the version of Window s, you may receive an error
message that the d efault dr iver is newer than the provided one. Ignore
this message.
Setup continues to load files, and a Window s Setup screen
appears.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
56/128
56 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 38 Windows setup screen
6. Press Enter to begin th e setup p rocedure.
Note: If you are installing Windows on a new ly created LUN, you m ay
receive a message that you r boot d isk is new or erased. Press C to
continue.
A Wind ows Licensing Agreement ap pears.
7. Read the license agreement. (Press Pg Dn as necessary to scroll
throu gh th e text.) To accept the agreem ent, press F8.Setup insp ects your comp uter's hard ware configuration. The
setup screen d isplays disk par tition information (if your system
already contains p artitions), or lets you create a new partition.
(Refer to Figure 39 on page 57.)
-
8/3/2019 Qlogic HBA Installation
57/128
Installation and Configuration
8. If you are installing an operating system for the first time,
highlight Unpartitioned Space on the H BA Then:
-
8/3/2019 Qlogic HBA Installation
58/128
58 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
highlight Unpartitioned Space on the H BA. Then:
Press Enter to use the entire d isk as one partition
or
Press C to create a custom p artition, and th en specify the
part ition size
If the new disk is displayed as Unformatted or Damaged you
mu st delete the partition before continuing. To do th is, press D ,
and follow th e onscreen d elete instru ctions. After you delete the
part ition, the disk will then appear as Unpartitioned Space.
If you are reinstalling Window s, the setup software prom pts you
to overwrite or up grade:
To overwrite, press Esc and follow instructions.
To upgrade, p ress Enter.
To create a new hard-disk partition, you mu st first delete the
existing par tition, and then create a n ew one. To do so, selectthe par tition you wan t to delete, press D , and then follow the
onscreen instru ctions to comp lete the deletion of the par tition.
Once the system deletes the partition, you can press C to
create a new on e.)
9. The setup software prompts you to specify the file system format
for the p artition . Select NTFS fil e sys tem format (wh ich is
suitable for most sites) and p ress Enter, unless you have other
specific requirements.
Note: For background information on the choice of the N TFS file system,
refer to Microsoft Know ledge Base Art icle 184006.
Setup formats the partition, copies the Wind ows system files to
the partition, and starts rebooting the server.
10. When promp ted, remove the diskette and CD-ROM.
11. If your system promp ts you to press any key to boot from
CD-ROM, do n ot p ress a key. Instead, allow the system to boot
from the array (if external) or the local disk (if internal). After
booting, the system continues installation, displays the Window s
banner, and begins autod etection of mass-storage d evices and
adapters.
Installation and Configuration
12. Follow the onscreen instructions to comp lete the installation.
When the Completing the Windows Setup Wizard screen
-
8/3/2019 Qlogic HBA Installation
59/128
Insta lling t he Wind ow s op era ting system 59
p g p
appears, clickFinish.
13. Install the latest EMC-app roved Wind ows Service Pack and/ or
OS patches or up dates. Follow the p rocedu res in the Microsoft
documentation that accomp anies the u pd ates.
-
8/3/2019 Qlogic HBA Installation
60/128
Installation and Configuration
2. Go to http:/ / www.qlogic.com.
3 Select Downloads on the left side of the page
-
8/3/2019 Qlogic HBA Installation
61/128
Installing HBA driver and software utilities 61
3. Select Downloads on the left side of the page.
4. Select EMC und er OEM models.
5. Select the link containing your EMC storage.
6. Select the HBA you installed in your system and d ownload the
SANsurfer Install Wizard for Window s.
Driver installation/ upgrade1. Install the SANsurfer Install Wizard for Windows Kit CD-ROM to
start the SANsurfer HBA Install Wizard . If you dow nloaded the
kit to your ha rd dr ive locate and double-click the file. The
following w izard w ill appear.
Figure 40 SANsurfer driver installation type
-
8/3/2019 Qlogic HBA Installation
62/128
-
8/3/2019 Qlogic HBA Installation
63/128
Installation and Configuration
4. Click Next to continu e. A message similar to the following w ill
appear:
-
8/3/2019 Qlogic HBA Installation
64/128
64 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 43 SANsurfer installation with version number
5. The version of driver to be installed will be listed. Follow the
instructions and clickNext.
-
8/3/2019 Qlogic HBA Installation
65/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
66/128
66 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 45 SANsurfer driver installation completed successfully
7. A Driver installed successfully message will appear w hen the
driver is installed . ClickNext to continu e.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
67/128
Installing HBA driver and software utilities 67
Figure 46 SANsurfer driver installation complete
The HBA Configuration Update screen w ill app ear after the driver
installation is complete. From here, you m ay perform d iagnostic
procedu res or other p ost-installation tasks. If you are finished with
your HBA up date, clickQuit.
Post-installation procedures
Diagnostics 1. From the HBA Configuration Update screen, clickPerformDiagnostics (refer to Figure 46).The SAN surferHBA Install
Wizard wind ow w ill appear, as shown in Figure 47 on page 68.
-
8/3/2019 Qlogic HBA Installation
68/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
69/128
Installing HBA driver and software utilities 69
Figure 48 SANsurfer install wizard attach storage
3. Ensure that the H BAs you selected for diagnostics are connected
to storage or to a loopback terminator. ClickNext to run the test.
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
70/128
70 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 49 SANsurfer HBA installation diagnostics results
4. The next wind ow will display the diagnostics results. More
information on this tool is available at the QLogic website
www.qlogic.com. Select Next to return to the main m enu.
Installation and Configuration
Show SAN
Figure 50 show s the SAN t ree.
-
8/3/2019 Qlogic HBA Installation
71/128
Installing HBA driver and software utilities 71
Figure 50 Show SAN tree
The Show SAN featu re is useful for verifying connectivity to the
storage array.
Installation and Configuration
Verifying connectivity to the storage array
On a Wind ows 2000/ Wind ows Server 2003 system do one of the
-
8/3/2019 Qlogic HBA Installation
72/128
72 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
On a Wind ows 2000/ Wind ows Server 2003 system, do one of thefollowing to star t the SANsur fer application, which includ es the
SANsurfer FC HBA Manager GUI. When comp lete, the SANsur fer
app lication GUI d isplays. (Refer to the SAN surfer FC HBA Manager
main w indow, as shown in Figure 53 on page 74).
1. Double-click the SANsurfer icon, as shown in Figure 51, on your
desktop (if the icon w as created du ring installation).
Figure 51 SANsurfer icon
2. Click Connect on the SAN surfer FC HBA Manager mainwind ow toolbar.
3. On the SAN surfer FC HBA Manager main window Host menu,
clickConnect.
4. Right-click the HBA tree. From the shortcut menu, clickConnect.
5. Press HOME.
The Connect to Host dialog box displays, as shown in Figure 52on page 73.
-
8/3/2019 Qlogic HBA Installation
73/128
Installation and Configuration
-
8/3/2019 Qlogic HBA Installation
74/128
74 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 53 SANsurfer, SANsurfer FC HBA manager
Installation and Configuration
Installing additional Navisphere Host Agent software
The Navisphere Host Agent should be used to au tomatically registerh t ti ith th P P th d ATF i diff t
-
8/3/2019 Qlogic HBA Installation
75/128
Insta lling a d d itiona l Nav isp here Host Ag ent softw a re 75
p g y ghost connections with the ar ray. PowerPath and ATF require different
registration types and th e Navisph ere Host Agent is the preferred
method over man ual registrations.
You shou ld install the Navisph ere Host Agent software to ensu re the
HBA connections are all registered correctly. For instructions on how
to perform th is operation refer to the EMC ControlCenter N avisphere
Host Agent software d ocumentation for your array type.
After the h ost agent has started and registered the n ew H BA p aths,
you shou ld refresh the host connections in the storage group to
ensure all available paths are assigned . To do th is, you h ave tw o
options, depend ing on w hether you w ant to d isrupt the connectivity
of the host, as described n ext.
Option 1: Without disrupting host connectivity (more complexprocedure using Navisphere CLI):
Note: You m ust have Navisphere CLI installed. Refer to prod uct notes for
complete usage instructions.
1. Using a command prompt, browse to the Navisphere CLI
directory (typically C:\ Program Files\ EMC\ Navisphere CLI>.
2. En ter command navicli -h storagegroup
-connecthost -host -gname
wh ere is the IP add ress of either array SP; is
the hostname of the host connection to up date and
is the name of the storage group of the host
connection to up date.
3. When prompted, verify the and
are correct as follows:
Connect host to storage group (y/n)?"
Enter y to proceed.
4. Perform a device rescan on your host, and verify the additional
device paths are present.
Installation and Configuration
Option 2: With brief disruption of host connectivity (simpler proce dure
using Navisphere GUI):
1. Shut down the host .
2 Remove the host from the storage group
-
8/3/2019 Qlogic HBA Installation
76/128
76 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
2. Remove the host from the storage group.
3. Apply the change.
4. Add the host back into the storage group.
5. Restart the host .
6. Check the array connectivity status to ensure all connections you
require are active.
-
8/3/2019 Qlogic HBA Installation
77/128
Misce llaneous Planning and Proce dures
Zoning and connection planning in a fabric environment
In a fabric environm ent, the user shou ld p lan for the switch topology,target-to-hosts map ping, and the zone. Here is an overview of the
-
8/3/2019 Qlogic HBA Installation
78/128
78 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
target to hosts map ping, and the zone. Here is an overview of the
recomm ended procedure:
1. Draw the connectivity among the hosts, switch, and storage array
to verify the correct fabric configuration.
2. Configure the zone capability in the switch. If connecting to
EMC Connectrix, refer to th e Connectrix v7.01 Enterprise Storage
Network System Planning Guide for information on th e zoneconfiguration.
Misce llaneous Planning a nd Procedures
Installing and configuring the QLogic QLA4010 iSCSI HBA (TOE)
The QLA4010/ 4010C is an iSCSI HBA that p rovides PCI connectivityto SCSI using th e iSCSI pro tocol. iSCSI enables IP-based SAN s, wh ich
-
8/3/2019 Qlogic HBA Installation
79/128
Insta lling a nd c on figu ring the QLog ic QLA4010 iSCSI HBA (TOE) 79
g p ,
are similar to Fibre Chann el SAN s. The QLA4010/ 4010C HBAs
imp lement TCP/ IP protocol on the H BA and relieves the host of any
I/ O protocol processing. This type of adap ter also is called a TCP/ IP
Offload Engine (TOE) ad ap ter. Off-load ing frees the system to
perform other tasks and optimizes system performance.
Installation of the QLA4010 iSCSI HBA is similar to installation of
other QLogic HBAs. Refer to the sections for Installing the H BA on
page 18 an d Manu ally installing the H BA driver Advan ced users
on page 93 for configurations tha t are booting from the EMC storage
array.
Using the QLogic iSCSI SANsurfer application to configure iSCSI device s
QLogic provid es a minim al version of their SAN surfer software usedto configure sett ings for the QLA4010 iSCSI HBA. For configu rations
not using Microsofts iSCSI Initiator, the SAN surfer iSCSI HBA Man-
ager shou ld be u sed to configure you r iSCSI HBAs.
Install the SAN surfer iSCSI HBA Man ager on your server using the
self-extracting executable insta llation package (available in the EMC
QLA4010 CD-ROM kit or from th e QLogic website
http:/ / ww w.qlogic.com). During installation, you m ay choose
whether to install both the GUI and agent or just the GUI. If you are
installing on the system with the QLA4010 HBA(s) installed , insta ll
both the GUI and agent.
After SANsurfer is installed, it can be started from the Start menu , or
from the d esktop icon if you choose to create one.
-
8/3/2019 Qlogic HBA Installation
80/128
Misce llaneous Planning a nd Procedures
From th e HBA Options, you can set the iSCSI HBA param eters
includ ing IP add ress, subnet m ask, and gateway. If an iSNS
server is being used for your iSCSI configuration follow the
procedu re for setting u p iSNS later in Configuring iSNS settingsfor QLA4010, next.
-
8/3/2019 Qlogic HBA Installation
81/128
Insta lling a nd c on figu ring the QLog ic QLA4010 iSCSI HBA (TOE) 81
Q ,
Figure 55 SANsurfer iSCSI HBA manager, HBA options
Configuring iSNS settings for QLA4010For iSNS sup port, the Q LA4010 mu st be run ning th e correct d river.
Refer to theEMC Support M atrix for latest version.
Targets mu st register w ith th e iSNS server. To register, enable the
iSNS server and en ter the IP add ress using the SAN surfer iSCSI
HBA Manager, HBA Options, N etwork, Enable iS NS dialog box.
ClickSave HBA und er the Network tab on the SAN surfer iSCSI
HBA Manager, HBA Options tab.
Misce llaneous Planning and Proce dures
The target should be d etected by SANsurfer and shown on the
SANsurfer iSCSI HBA Manager, Target Settings tab. ClickSave
Settings to bind the targets.
If the targets are not d etected, follow these steps:
1 Ping successfully to the iSNS server using the Diagnostics tab
-
8/3/2019 Qlogic HBA Installation
82/128
82 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
1. Ping successfully to the iSNS server using the Diagnostics tab
from the SAN surfer iSCSI HBA Manager dialog.
2. Go to iSNS server and iSNS server icon in the control panel or
desktop.
3. Open Discovery Domain and confirm that both the QLA4010
and target p orts are registered with th e dom ain.To u pd ate firmw are on your iSCSI HBA:
1. Click th e Firmware tab on the HBA Options dialog, as show n in
Figure 56.
Figure 56 SANsurfer iSCSI HBA manage r, HBA options, firmwa re tab
2. Click Select Firmw are to Dow nload .
Misce llaneous Planning a nd Procedures
3. In the dialog that appears, as shown in Figure 57, type in the path
to the firmware file that you want to load to the HBA, and click
Save.
-
8/3/2019 Qlogic HBA Installation
83/128
Insta lling a nd c on figu ring the QLog ic QLA4010 iSCSI HBA (TOE) 83
Figure 57 Download firmwa re dialog
The firmw are w ill be loaded to the specified H BA. After it load s,
SAN surfer will reset the H BA so the new firmware will take effect.
Boot BIOS for th e iSCSI HBA can be load ed in a similar fash ion.
From th e SAN surfer iSCSI HBA Manager, HBA Option dialog,
click the BIOS tab, as show n in Figure 58.
Figure 58 SANsurfer iSCSI HBA manager, HBA options, BIOS tab
Misce llaneous Planning and Proce dures
To configu re your iSCSI targets, click the Target Settings tab from
th e SAN surfer iSCSI HBA Manager dialog, as show n in
Figure 59.
-
8/3/2019 Qlogic HBA Installation
84/128
84 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Figure 59 SANsurfer iSCSI HBA manager, target settings tab
To ad d your target, click the green + on the right side of the Target
Settings tab to get the IP Address dialog, as show n in Figure 60.
Enter the IP add ress of your t arget por t, and clickOK.
Figure 60 SANsurfer iSCSI HBA Manage r, Target settings, IP Address dialog
Misce llaneous Planning a nd Procedures
You can add as many targets as needed. If you need to enter
CHAP security for any target, clickConfig Authentication at
the bottom of the dialog, as shown in Figure 59 on page 84, to
get the Authentication Configuration d ialog, shown inFigure 61.
-
8/3/2019 Qlogic HBA Installation
85/128
Insta lling a nd c on figu ring the QLog ic QLA4010 iSCSI HBA (TOE) 85
Figure 61 Authentication configuration, CHAP tab
On the Authentication Conf iguration, CHAP tab, you can:
Set a default name and secret for all targets; or
Click the individual target and enter an unique name and
secret settings for that target.
Note: Initiator CHAP settings do not get masked and could be
compromised if an unauthorized user accesses the SANsurfer
workstation.
Misce llaneous Planning and Proce dures
After CHAP settings are made, clickOK at the bottom of the
Authentication Configuration dialog, as shown in Figure 61 on
page 85.
To sav e all ta rget settings, clickSave at the bottom of the
SANsurfer iSCSI HBA Manager, Target Settings tab, as shown
-
8/3/2019 Qlogic HBA Installation
86/128
86 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
in Figure 59 on page 84. You will be prom pted for the SANsurfer
security password . The default password is config, but it can be
changed.
After the settings are saved , SANsurfer resets the H BA, and if
target information w as d iscovered p roperly, you w ill see active
connections listed on th e SAN surfer iSCSI HBA Manager, TargetInformation tab. You can also view active targets un der the H BA
in the left pan e as shown in Figure 62.
Figure 62 SANsurfer iSCSI HBA Manager, Information tab
SANsurfer has other featu res that are u seful in m anaging your iSCSI
storage configuration. Please refer to the Q Logic SANsurfer docu-
men tation for more information abou t these add itional features.
Misce llaneous Planning a nd Procedures
Booting from SAN with QLogic QLA40xx and Microsoft Initiator
The following procedu re for booting from SAN with a QLogic iSCSIHBA with Microsoft Initiator Service is illust rated using a CLARiiON
CX series storage arr ay. Booting with a QLogic iSCSI HBA with
-
8/3/2019 Qlogic HBA Installation
87/128
Boo ting from SAN w ith QLog ic Q LA40xx and Mic rosoft Initia to r 87
g y g g
Microsoft Initiator Service can also be done on a Symmetrix storage
array. For m ore information, refer to Symm etrix LUN Masking
documentation.
The importan t concept is understan ding the HBAs iqn name, its
relationship to persistant binding in a SAN env ironmen t, and how
the Microsoft Initiator Service chan ges the iqn n ame.
IMPORTANT!Failing to change the iqn name before installing the Windows
operating system w ill cause the hos t to blue screen for an
inaccessible boot device when the Microsof t Initiator Service
changes the iqn name after being installed.
Note: Booting from SAN w ith QLA40xx and Microsoft Initiator follows the
same setu p configur ation as boot from SAN with the QLogic QLA40xx iSCSI
HBA.
IMPORTANT!At this point, only connect the HBA that will be used to boot.
Remaining HBA(s) can be connected after the Window s operating
system is installed. Failing to do so could result in a blue screen
during the installation process. Best practice recommends having
only the LUN you will be booting from presented to the host. This
will ease the process of se lecting the correct boot LUN during the
HBA configuration and during the O/S installation. Remaining
LUN S can be added after the ins tallation.
1. The first step is to know what you are going to name your server
and how that tran slates into an iqn nam e. Microsoft Initiator uses
the followin g naming conven tion: iqn.1991-05.com.microsoft
:servername.domainn ame. Therefore, if the server nam e is to be
test, and the domain nam e is workgroup, then the name the
Initiator w ill use to renam e the H BA w ill be
iqn.1991-05.com.microsoft:test.workgroup.
Misce llaneous Planning and Proce dures
2. On the host, go into the QLogic BIOS and change the iqn nam e to
iqn.1991-05.com.microsoft:servernam e. (If netw orking is
configured d uring installation, set the iqn name to
iqn.1991-05.com.microsoft :servername.domainname).
This can be accomplished by the following procedu re:
-
8/3/2019 Qlogic HBA Installation
88/128
88 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
a. On POST when the QLogic HBA displays, press < Ctrl Q>
for Fast!Util.
b. Go to Configuration Settings > Host Adapter Settings.
c. Toggle down to Initiator iSCSI Name.
d . Press Enter on the name and type in thenew name.
e. Press ESC twice to get to Save Settings.
f. Save the settings. This will force a login to the storage device.
3. Register the new iqn name and add it to your storage group on
the CLARiiON storage array.
Note: Only register one p ath. Ensure that the p ath is from the SP that thelun belongs to. Failing to do so could result in a blue screen du ring the
installation process. You can also refer to CLARiiON docum entation for a
more d etailed p rocedure for setting u p Storage Groups and Registering
host names.
4. On the host in the QLogic Fast!Util, go to the iSCSI Boot
Settings.
5. In Primary Boot Device press < Enter>.
This will bring you to the d evice list page.
6. Select the DGC device that displays the RAID level.
Ensure that the iSCSI Boot field on that p age is set to Enabled .
7. Save all settings and reboot the host and load the Operating
System. Refer to Installing the Window s operating system onpage 52.
8. After the operating system is loaded and before the initiator
service is loaded , register the remaining p aths on the CX storage
array.
9. Install the Initiator Service.
Misce llaneous Planning a nd Procedures
10. During the Microsoft Initiator installation, deselect th e Software
Initiator. ON LY ins tall the Initiator Service. This will attemp t to
change the iqn na me to fit the Microsoft nam ing convention.
Since this was d one in step 2, it w ill not blue screen th e host for aninaccessible boot d evice.
-
8/3/2019 Qlogic HBA Installation
89/128
Boo ting from SAN w ith QLog ic Q LA40xx and Mic rosoft Initia to r 89
-
8/3/2019 Qlogic HBA Installation
90/128
Misce llaneous Planning a nd Procedures
Setting up external boot for IBM BladeServer HS40 (8839)
This section contains th e folloiwng information:
Configuring an HS40 BladeCenter server to boot from an
external array on page 91
-
8/3/2019 Qlogic HBA Installation
91/128
Set ting up exte rna l bo o t fo r IBM Bla deServe r HS40 (8839) 91
BladeServer restrictions on page 92
Configuring an HS40 BladeCenter server to boot from an external array
IBM H S40 (8839) Bladeserver s encounter a dua l-port HBA conflictwhen a ttemp ting to configure boot BIOS to boot from an external
array. To configu re an H S40 BladeCen ter server to boot successfully
follow th e steps below.
1. Create a single zone containing the HBA port from wh ich you
want to boot. This preven ts any conflicts with the other fibre
port.
2. Configure the QLogic BIOS to boot from the EMC array asdescribed earlier in QLogic QLA23xx-based FibreChann el HBA
BIOS/ boot LUN settings on page 26. Dur ing server POST, be
sure tha t the QLogic banner d isplays the selected boot LUN
correctly before continuing.
3. Reboot the host and pressF1 to enter the server BIOS
Configuration/Setup Utility.
4. Select Devices and I/O Portsand p ress Enter.
5. Select IDE Configuration Menu and p ress Enter
6. Select the Onboard PCI IDE Controller and p ress Enter. Under
the options m enu , set this IDE Controller to disabled. This will
disable the internal IDE disk drives.
7. Press ESC twice to return to the IDE Configuration Menu an d
then select Start Options and p ress Enter.
8. Select Startup Sequence Options and p ress Enter.
9. Select Third Startup D evice and press Enter.
10. Select HAx PortID xxxxxx xxxxx and p ressEnter. This boot d evice
will be replaced as the Third Startup Device in the Startup
Sequence Options.
Misce llaneous Planning and Proce dures
11. Press ESC un til you are prom pted to save your changes. Then exit
th e BIOS Conf iguration/Setup Utility.
BladeServer restrictions
Table 2 describes QLogic software support for the BladeServer.
-
8/3/2019 Qlogic HBA Installation
92/128
92 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
Q g pp
Table 2 BladeServer/QLogic software support matrix
BladeServermanufacturer
SANsurfer Install Wizardfor Windows
SANsurfer FC HBA Managerfor Windows
Dell No Yes
HP No Yes
IBM No Yes
Misce llaneous Planning a nd Procedures
Manually installing the HBA driver Advanced users
To use EMC storage array disks with a Windows host, you need an
EMC-qualified Fibre Channel HBA driver. The HBA kit includes an
EMC-app roved d river, wh ich mu st be installed and configured p rior
to pa rtitioning th e storage array d isks. You a lso shou ld check the
-
8/3/2019 Qlogic HBA Installation
93/128
Ma nua lly insta lling the HBA d river Ad va nc ed users 93
to pa t t o g t e sto age a ay d s s. ou a so s ou d c ec t e
QLogic website for the latest EMC-approved version. Refer to
Dow nload ing latest QLogic dr ivers/ firmware/ BIOS files on
page 16.
These procedures are n ecessary if not using the SANsur fer H BA
Install Wizard . Refer to Installing HBA d river and software u tilitieson page 60.
Driver revision
History Driver sup port is as follows:
Version 8.1.5.20 QLA22xx, QLA23xx (no CX200 series
direct-connect dual host cluster), Windows 2000
Version 8.1.5.21 QLA23xx, Window s 2000
Version 8.2.1.20 QLA23xx, Window s 2000
Version 8.2.2.20 QLA23xx STORPort, Window s 2003 only
Version 8.2.2.25 QLA23xx, Windows 2000 and Windows 2003
STORPor t 8.2.3.26 and SCSIPort 8.2.3.21 QL23xx, Wind ow s 2003(SCSI and STOR) and Windows 2000 (SCSI only)
STORPor t Version 8.2.3.27 QLA23xx, Wind ow s 2003 only
STORPor t 9.0.0.17 and SCSIPort 9.0.0.12 QL23xx, Wind ow s 2003
(SCSI and STOR) and Windows 2000 (SCSI only)
STORPort 9.0.1.18 Stratus computers only and SCSIPort 9.0.0.12
QL23xx, Windows 2003 (SCSI and STOR) and Windows 2000
(SCSI only)
STORPor t 9.0.1.17 and SCSIPort 9.0.1.12 QL23xx, Wind ow s 2003
(SCSI and STOR) and Windows 2000 (SCSI only)
STORPor t 9.0.1.15 and SCSIPort 9.0.1.10 Dell 2342M/ 2362M
embedded adapters, Windows 2003 (SCSI and STOR) and
Windows 2000 (SCSI only)
Misce llaneous Planning and Proce dures
STORPort 9.0.2.17 and SCSIPort 9.0.2.12 QLA23XX, snf WLzr
23XX, Window s 2003 (SCSI and STOR) and Wind ow s 2000 (SCSI
only)
STORPort 9.1.0.15 and SCSIPor t 9.1.0.10 QLA23XX, QLE 23XX,QLA24XX, QLE24XX, Windows 2003 (SCSI and STOR) and
Windows 2000 (SCSI only)
-
8/3/2019 Qlogic HBA Installation
94/128
94 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
STORPort 9.1.2.15 and SCSIPor t 9.1.2.10 QLA23XX, QLE 23XX,
QLA24XX, QLE24XX, Windows 2003 (SCSI and STOR) and
Windows 2000 (SCSI only)
STORPort 9.1.2.16 and SCSIPor t 9.1.2.11 - QLA23XX, QLE 23XX,
QLA24XX, QLE24XX, Windows 2003 (SCSI and STOR) andWindows 2000 (SCSI only)
STORPort 9.1.4.15 and SCSIPor t 9.1.4.10 - QLA23XX, QLE 23XX,
QLA24XX, QLE24XX, and embedded OEM H BAs. Windows 2003
suppor ts STORPort driver only and Wind ows 2000 sup ports
SCSIPort d river only.
Where to find the driver
You can find the Fibre Chann el HBA driver:
On th e QLogic CD-ROM that accomp anied th e HBA. Copy th e
dr iver from the OS-specific directory: \ Wind ows2000 or
\ Wind ows2003
On the QLogic website. Refer to Download ing latest QLogic
drivers/ firmw are/ BIOS files on page 16
To ease installation of the d river, unzip the d river file onto a blank
diskette.
Windows 2003 STORPort upda tes
Currently th e shipp ing version of Window s 2003 requires post-RTM
hot fixes to resolve some known issues. For all Wind ows 2003STORPort installations, you should obtain the current Microsoft QFE
hotfix listed in theEMC Support M atrix with the H BA driver
revisions.
Install this patch before installing the HBA driver. Window s 2003
Service Pack 1 (x86 and IA64) and Window s 2003 x64 contain the
latest STORPort hot fix and does not require a p ost-RTM QFE.
Misce llaneous Planning a nd Procedures
IMPORTANT!EMC recommends that users planning to upgrade to Service Pack 1
for Windows 2003 should upgrade the ir HBA drivers to the latestsupported version prior to installing the service pack.
-
8/3/2019 Qlogic HBA Installation
95/128
Ma nua lly insta lling the HBA d river Ad va nc ed users 95
Migrating Windows 2003 drivers from SCSI to STOR
As of April 2006, STORPort has been fully ad opted by th ird-party
software and tap e vendor s and EMC is proceeding towards sole
STORPort sup port u nd er Wind ows 2003. Add ing to the technicalbenefits of STORPort, phasing-out SCSI miniport on Wind ow s 2003
will provid e better coordination of driver version support from
OEMs. STORPort will be the comm on d river platform for all server
and storage vendors to p rovide the customer w ith compatible
solutions.
In the April 2006EMC Support M atrix (ESM), EMC will make SCSI
driver releases for Windows 2003 x86 from QLogic frozen as the last
sup ported Window s 2003 SCSI versions. Once this end -of-life (EOL)
is in effect, new installs will still be permitted with the SCSI drivers
for three mon ths, but EMC encourages customers to u se STORPort
instead. Three months after the EOSL (after th e Jun eESM) EMC will
make th ese Window s 2003 SCSI versions EOL. Upon EOSL, start ing
with the JulyESM, the Windows 2003 SCSI versions w ill no longer be
listed and w ill not be sup ported for new installations. Existing
customers w ho h ave Window s 2003 SCSI already installed w ill besup ported , and any fix or MS HCL sup port w ill likely require an
up grad e to STORPort. Windows 2000 will continu e to use SCSI
drivers as the only option.
What to expect when moving from SCSI miniport/ Full Port drivers to
STORPort drivers
In STORPort drivers, functions or settings that u sers may have set
may no longer be available or may be accessed differently than in the
past. These are now controlled by the OS. EMC has always p rovided
stand ard settings wh ich w ere accessible via dr iver configuration
utilities. For STORPort drivers, EMC will require that the default
settings for STORPort drivers be used u nless otherwise instructed.
Configuration utilities for STORPort that ru n u nd er Wind ows
(SAN Sur fer as well as the Qlogic Ease of Use installation k it), will
allow access to settings for the driver that m ay be changed via the
ut ility if necessary.
Misce llaneous Planning and Proce dures
Installa tion procedure for Windows 2000 and Windows 2003 hosts
To install the d river into a Windows 2000 or Window s 2003 host,
follow these steps:
1. Boot the host with Wind ows 2000 or Window s 2003.
2 From the Windows taskbar select Start > Run then type
-
8/3/2019 Qlogic HBA Installation
96/128
96 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
2. From the Windows taskbar, select Start > Run, then type
Compmgmt.msc and p ress Enter.
3. In the left pane of the Computer Management window, click the
Device Manager icon.
4. If Wind ows Plug-n-Play does not detect your QLA23xx HBAmod el, it will be listed as Unknown or as a Fibre Channel
Controller und er the Other Devices icon in the right pane.
Window s 2000 configurations with Service Pack 1 or higher and
Windows 2003 configurations may be able to detect QLA23xx
HBAs. If this occurs, the H BA w ill already be listed un der SCSI
Devices. Instead of proceeding with these installation steps,
follow the instructions under Upd ating the HBA driver in aWind ows 2000 or Window s 2003 host on p age 97. Double-click
the first instan ce of SCSI Controller und er Other Devices.
5. In the next window, clickReInstall Driver, then Next.
6. Select Display a list of the know n drivers for this device so that
I can choose a specific driver, then clickNext.
7. Select SCSI and RAID Controllers, then clickNext.
8. Click Have Disk.
9. Enter the path to the diskette containing the driver (for examp le,
A:\), then clickOK.
10. Select the ap prop riate QLogic HBA from the list of dr ivers that
appears; then clickNext.
11. In the next wind ow, clickNext.
12. ClickYes to continue the installation.
13. ClickFinish to complete the d river installation.
14. The system requ ests that you reboot the system. Select No an d
clickClose.
15. The system again requ ests that you reboot the system. Select No
again.
Misce llaneous Planning a nd Procedures
16. If there are other QLogic HBAs installed, repeat steps 5 through
16 un til all adap ters have been installed.
17. Reboot the host.
Upda ting the HBA driver in a Windows 2000 or Windows 2003 host
-
8/3/2019 Qlogic HBA Installation
97/128
Ma nua lly insta lling the HBA d river Ad va nc ed users 97
On Wind ows 2000 and Wind ows 2003 systems w here the QLogic
HBA has been d etected au tomatically or a driver is already installed,
it may be necessary to up da te the curren t dr iver to the latest
EMC-qualified driver, as described in this section.
The following procedure assumes that you have copied the latest
dr iver from the QLogic CD-ROM or dow nloaded it from the QLogic
website and pu t it onto a d iskette. Refer to the release notes provided
with the d river for information that m ight be unique to new driver
revisions.
To install the d river into a Window s 2000 or Window s 2003 host:
1. Boot the host (if necessary) with Window s 2000 or Window s 2003.
2. From the Windows taskbar, clickStart > Run, then type
Compmgmt.msc and p ress Enter.
3. In the left pane of the Computer Management window, click the
Device Manager icon.
4. Double-click the SCSI & RAID Controllers icon.
5. Under SCSI & RAID Controllers, double-click the adapter you
wish to upgrad e.
6. In the next window, click the Driver tab; then clickUpdate
Driver.
7. Follow the up date wizard u ntil you are given the choice to
Display a list of the unknow n drivers for this device so that you
can choose a specific driver. Click the but ton n ext to this choice;
then clickNext
.8. In the Select a Driver window, clickHave D isk.
9. Enter th e path to the diskette containing th e driver (A:\, for
example), or u se the brow se fun ction to locate the dr iver; then
clickOK.
10. Select the d river that is discovered an d clickNext.
11. In the next wind ow, clickNext.
Misce llaneous Planning and Proce dures
12. If promp ted, clickYes to continue the installation.
13. ClickFinish to complete the installation.
14. If the system requests that you reboot the system and you haveother adapters to up da te, select No; then clickClose.
15. If the system again requests that you reboot the system and you
have other ad ap ters to up date select No; then click Close
-
8/3/2019 Qlogic HBA Installation
98/128
98 EMC Fibre Cha nne l and iSCSI with QLog ic Host Bus Ad a p ters in the Wind ow s Environm ent
have other ad ap ters to up date, select No; then clickClose.
16. If you have other ad apters to up date, select the next adap ter
under SCSI & RAID Controllers and repeat steps 6 through 15.
When all adapters have h ad their drivers upd ated, select Yes to
the reboot promp t.
For more information on conn ecting to a SAN an d installing
dr ivers/ firmware on HP Proliant BL p-Class server blades, see the
"how to" gu ide, Connecting ProLiant BL p-Class server blades to a third
party SA N, available at the w ebsite as follows:
http://h200005.www2.hp.com/bc/docs/support/SupportManual/c00220357/c00220357.pdf
Upgrading to Windows 2003 from Windows 2000
Note th e following if upgrad ing to Window s 2003:
Upgrad ing from Window s 2000 - The Wind ows 2000 drivers m ay
be p reserved w hile up grad ing to Wind ows 2003. These SCSIPort
drivers (including the na tive Window s 2003 SCSIPort dr ivers) are
not supp orted by EMC for Window s 2003. You should obtain thecorrect Wind ows 2003 drivers. Refer to Downloading latest
QLogic drivers/ firmware/ BIOS files on page 16, and reinstall
the drivers after the up grad e is comp lete.
Cur rently, to u pgrade from Window s 2000 to Wind ows 2003, you
mu st first uninstall PowerPath . After upgrad ing the host, you can
reinstall an app roved Wind ows 2003 version. Please refer to the
EMC PowerPath d ocumen tation for fur ther d etails. You m ay
wish to disconnect your storage du ring the Windows u pgrad e,and reconnect it after the ap proved Wind ows 2003 dr ivers are
installed.
Misce llaneous Planning a nd Procedures
Editing the Windows time-out value
While QLogic drivers will set